User'S Manual: Split Type Wall Mounted Air Conditioner
User'S Manual: Split Type Wall Mounted Air Conditioner
User'S Manual: Split Type Wall Mounted Air Conditioner
USER’S MANUAL
Read the manual carefully before operation and keep it for reference.
This manual is only for reference, please comply with actual appliance
you selected. manufacturer hold the authority to redesign or modify its
products without notice.
SAFETY PRECAUTIONS
WARNING: Following these basic precautions will reduce the
CONTENTS
1. SAFETY INSTRUCTIONS
Symbol Description…………………………………………………..……….………..….2
Installation Instruction…………………………………………………..…….……….…. 2
Operating Instruction………………………………………………………….……….…..3
Safety Instruction… …………………………………………………………..……….… 6
2. PRODUCT INTRODUCTION
Protect Functions………………………………………………….. …….….………….…7
3. DESCRIPTION OF COMPONENTS
View of Unit………………………………………………………………………...…………8
Display screen………………………………………………………………….……..……...9
Indicator light………………………………………………………………….……..……. 9
Remote Controller…………….……………………………..……………….….………..10
Remote Controller Display…………………………………………………….………….11
4. OPERATING METHOD
AUTO, HEAT, COOL,sweep and DRY operation………………………………………….12
Clock Setting and On Timer…………………………………………………………………13
Off Timer and Program Control…………………………………..………………….…...…14
Emergency Run…….…………..…………………………………………………..…...….15
How to Adjust Air Flow……………………………………………………………………….15
Sleep Operation………………………………………………..……………………………15
5. SERVICE AND MAINTENANCE
Clean the front panel and remote controller………………………….……………….16
Clean Air Filter…………………..……………………………………………….…….……16
No use for long time…………………..…………………………………….…………....17
Recommendations for Energy Saving…………..……...……………………………..…18
6. TROUBLESHOOTING
Air Conditioner is in Error…………………………………………………………….…….19
Remote Controller is in Error…………………………………..…………………….….…20
7. NORMAL PHENOMENONS……………………………………….…………………..21
-1-
USER’S MANUAL
SAFETY INSTRUCTIONS
〖Symbol Description〗
〖Installation Instruction〗
Warning
Caution
Power specifications
Make sure that the capacity of socket or
Proper connection
wires and piping
Improper connection may decrease the
of
Installation environments
Do not install air conditioner at the place
Please
Operating instruction
operate air conditioner in
where there is flammable or corrosive air. accordance to this manual.
-2-
USER’S MANUAL
〖Operating Instruction〗
WARNINGS
Following the safety messages is very important. These messages can save
you from being injured or killed. Warning symbols alert you to be careful and
means danger. Always follow instructions to be safe and reduce chances of
injury or death. Warning and danger signs will precede safety messages.
Electrical safety
Grounding: This room air conditioner must be grounded.
Grounding reduces the risk of electric shock by providing an escape wire for the
electric current.
If the power cord has a grounding plug with a grounding wire, plug it into an outlet that
is properly installed and grounded.
If the power cord has not a grounding plug with a grounding wire ,the grounding wire
must connect the breaker that is properly installed and grounded.
Warning: Improper use of the grounding plug or breaker can result in a risk of electric shock. Call
a qualified electrician if you don’t understand the grounding instructions or if you are
not sure if the air conditioner is properly grounded. If the wall outlet or breaker is not
grounded, please contact an electrician to have it replaced with a properly grounded
outlet or breaker.
Do not, under any circumstances, cut or remove the third (ground) prong from
the power cord.
Adapter plug: We strongly advise against using an adapter plug or breaker.
Operating conditions
1. Temperature:T1 instance: -7℃~43℃(16℃~43℃ in cooling-only type)
T3 instance: -7℃~52℃(16℃~52℃ in cooling-only type)
If the unit runs beyond the temperature for a long time, it may cause cooling capacity to decrease
or protector to work.
2. Relative humidity: <80%
If the unit runs beyond the humidity range, condensate may be formed near blade and outlet of
air conditioner. It’ s normal.
3. In heating operation, strange smell may come from the unit. It is Normal phenomenon.
4. The performance parameters refer to name plate.
5. The waterproof level of indoor unit is IPX0. Do not use it in the laundry or bathroom.
6. The outdoor unit can’ t be installed in a closed area.
-3-
USER’S MANUAL
7. The fuse for indoor unit main board: T3.15AL 250V~(9K-22K);
The fuse for indoor unit main board: T 5AL 250V~(18K-24K);
The fuse for outdoor unit main board: T15AL 250V~or T20AL 250V~(9K-12K);
The fuse for outdoor unit main board: T30AL 250V~(18K-24K);
Tips
Install the unit on the north side, as normally that is the shaded side. This will
enhance the operation of your unit.
Use correct electric voltage and proper ampere for the unit to run effectively.
Only let a certified electrician do any modifications to your electrical outlet or
breaker.
Use a dedicated line for the operation of your air conditioner to avoid the possibility
of an electrical surge.
If the supply cord is damaged, it must be replaced by the manufacturer or its
service agent or a similarly qualified person in order to avoid a hazard.
The dimensions of the space necessary for correct installation of the appliance
including the minimum permissible distances to adjacent structures.
The appliance shall be installed in accordance with national wiring regulations.
Disconnect the power supply before cleaning and maintenance.
If the appliance is not connected by plug,an all-pole disconnection device which
has at least 3mm separation distance in all pole and a residual current
device(RCD)with the rating of above 10mA shall be incorporated in the fixed wiring
according to the national rule.
If the appliance is connected by plug,it must be positioned so that the plug is
accessible.
-4-
USER’S MANUAL
〖Operating Instruction〗
Only single-phase a.c. power can be used. Use the specified power cord; do not
change it.
please refer to nameplate for details.
Do not put fingers or sticks into the inlet or Do not put anything on the outdoor unit.
outlet of air conditioner; the running fan may
cause injuries.
Do not switch on or off the unit by plugging or Keep indoor ventilated, especially when
pulling off the plug, or by switching on or off there is operating gas equipment.
the breaker .
Do not substitute fuse with lead wire or other Pull off power plug or switch off breaker if
materials. the air conditioner is not used for a long
time.
-5-
USER’S MANUAL
〖Safety Instruction〗
The appliance is not intend for use by young children or infirm
persons without supervision.
Young children should be supervised to ensure that they do not play
with the appliance.
Warning: If the supply cord is damaged, it must be replaced by the manufacturer
or its service agent or a similarly qualified person in order to avoid a
hazard.
Don not connect the earth line to gas pipe, Do not pull off the power plug or switch off
water pipe. Improper grounding may cause the breaker when it is in operation.
electric shock.
Switch off the unit; cut off the power source Do not install air conditioner at the place
and contact service agent if there is abnormal where flammable gas may leak.
phenomenon (e.g. burning smell comes out).
Do not place plants or animals directly in the Please contact service agents for service.
path of the air conditioner’ s airflow. Doing so Improper service may cause accident.
could harm them.
Switch off the unit, cut off the power source For removal and installation of air
and make sure the fan stops before cleaning conditioner, please refer to professionals
the unit. or contact service agents.
-6-
USER’S MANUAL
PRODUCT INTRODUCTION
〖Protect Functions〗
Protect functions can prolong the air conditioner’ s service life and provide more comfortable airflow.
Delay-starting protection for the compressor
The compressor will restart working at least 3 minutes after being turned off to keep the pressure balance
of the cooling system.
Remarks:
Defrosting (not available for cooling-only type air conditioner)
The outdoor heat exchanger may frost if the outdoor temperature is low and humidity is high. In this case,
auto-defrosting has operated for sometimes. pause indicator will be on, indoor and outdoor fan stop.
Heating overload protection (not available for cooling-only type air conditioner)
When the temperature of indoor pipe is too high, air conditioner enters heating overload protection.
Blowing residual heat function (not available for cooling-only type air conditioner)
Indoor fan will keep running at low fan speed for some seconds when air conditioner is stopped in heating
mode.
Cooling airflow proof (not available for cooling-only type air conditioner)
In the first several minutes of heating operation, PAUSE indicator lights; indoor fan doesn’t run and louver
blades can not be controlled. About some minutes later, air conditioner will blow heat airflow, PAUSE
indicator is off.
Freeze-prevention
To prevent indoor heat exchanger freezing in cooling and dehumidification operation, compressor or
outdoor fan may stop running; indoor fan speed will be adjusted to a higher gear automatically.
Dry for enzyme-prevention (optional)
Indoor fan motor will go on running for 3 minutes at low fan speed when turned off in cooling mode in order to
keep dry condition inside the unit.
Reset power or Auto restart( alternative)
Reset power: When there is a power suspension, air conditioner will automatically switch off. When the
power is back, the unit will automatically reset power. For energy saving if there is no person in the room,
air conditioner will stay in PAUSE status. User needs to turn on Air conditioner by remote controller.
Auto restart: The unit memories the operation mode, air flow setting, temperature setting etc., so that
should there be a power failure when the unit is in operation, it will automatically return the same
operating conditions when the power is restored.
Cooling overload working (optional)
-7-
USER’S MANUAL
DESCRIPTION OF COMPONENTS
〖View of Unit〗
Air inlet
Indoor unit
Air outlet
Power cord
Outdoor unit
Air inlet(back)
Air outlet
Drain pipe
Remarks:
The air conditioner is consisting of indoor unit, outdoor
unit and remote controller. The design and shape are
different for different models. The above figures are only
schematic, and they may be slightly different from the
actual appliances you selected.
-8-
USER’S MANUAL
〖Display screen〗
“RUN” indicator:This signal light is on when the unit is is in “RUNNING” status. When
in Defrosting or Cooling airflow proof ,the indicator is flashing
“Temperature” indicator :This display can show the set temperature. when
the indicator display F4,F1orF2, means the air conditioner runs abnormally
Remarks:
1. Flashing of any indicator means the air conditioner runs abnormally, please contact the
distributor in time.
2. Function a: The air conditioner will only display “RUN” indicator to save electricity if it do
not receive any signal from remote controller in 30 seconds. If it receives signal from
remote controller for the second time, the display will still show the corresponding
indicators.
Function b: The indicators on the display screen can be still controlled by “Display” button
on remote controller.
NOTE: Function a or function b is optional, and it is designed already before the
product is dispatched from factory.
-9-
USER’S MANUAL
〖Remote Controller〗
Display Screen
For setting display
DISPLAY Button
To start or stop
DISPLAY when air
conditioner is in RUNNIG. SWING Button
For changing vertical
Sleep Button blades position and
swing or not.
For setting sleep function.
Remarks:
1. Temperature can be set between 16℃~32℃.
2. The function and display of Heat is not available for cooling-only air conditioner.
3. When there is something wrong with the remote controller, please press ‘RESET’ button and then operate again.
4.HEAT、AUTO function and display are not available for cooling-only type air conditioner.
5.If user want tomake the room air cool or warm quickly ,user can press “turbo” button in cooling or heating mode,air
conditioner will run in power function.If press “turbo” button again, air conditioner will exit power function.
6.The above illustration of remote controller is only for reference, it may be slightly different from the actual product
you selected.
-10-
USER’S MANUAL
OPERATING METHOD
〖AUTO, HEAT, COOL,SWEEP and DRY operation〗
Switch On
Press On/Off button to start air
conditioner. 1
Setting Operation Mode
AUTO HEAT SWEEP
COOL DRY 2
Temp Adjustment Buttons
Press “▼” “▲” buttons to set temp
as needed 3
Airflow selection
Press “SWING” button to select
airflow direction. 4
Setting Fan Speed
Four speeds can be selected
Auto High 5
Medium Low
Switch Off
Press On/Off button to stop air
conditioner. 6
Remarks:
1.When “AUTO” mode is set, air conditioner will adapt to HEAT, COOL mode according to the
D-value between indoor temperature and set temperature.
2.When “AUTO” mode is set, Sleep function is not available.
3.When “DRY” mode is set, in accordance with the D-value between indoor temperature and set
temperature. Air conditioner will start or stop the cooling operation and fan speed automatically to
decrease room humidity. Fan speed can’ t be controlled sometimes.
4.When SWEEP mode is set, temperature can’ t be adjusted. Step 2 of Operating procedures is not
effective. Only high, medium and low fan speed can be set; no Auto fan speed.
-12-
USER’S MANUAL
〖Clock Setting〗
〖On Timer〗
Note:
1. When on timer function is set, air conditioner will be turned off immediately. It will be turned on at the
set time, symbol “ON ” will be deleted. If the set time is as same to the current time, air conditioner will
be turned on at this time of next day.
2. Press “On/Off” to cancel “On Timer” function, air conditioner will be turned on immediately.
-13-
USER’S MANUAL
〖Off Timer〗
Note:
1. When off timer function is set, air conditioner will be turned on immediately. It will be turned off at the
set time, symbol “ OFF ” will be deleted. If the set time is as same to the current time, the air
conditioner will be turned off at this time of next day.
2. Press “On/Off” to cancel “Off Timer” function, air conditioner will be turned off immediately.
-14-
USER’S MANUAL
〖Emergency Run〗
When the remote controller is missing or the batteries are run out, you can use the Emergency Button.
Operation Method:
Under the “OFF” condition, open the front board and press Emergency Button with the tip end of a ball-pen or the
like and the Air conditioner will operate in “AUTO” mode. Press Emergency Button again to switch off the unit.
Warning:
Fan inside;
Keep hands away!
Louver blades
-15-
USER’S MANUAL
-16-
USER’S MANUAL
3. Maintain air filter net. 4. Take out batteries from remote controller.
-17-
USER’S MANUAL
-18-
USER’S MANUAL
TROUBLE SHOOTING
〖Air Conditioner is in Error〗
Normal phenomena
-19-
USER’S MANUAL
Failure inspection
-20-
USER’S MANUAL
NORMAL PHENOMENONS
When it is heating or cooling, plastic If the indoor humidity is too high, water
substance may give out a sound because of drops may form on the front grill of indoor
the temperature change. unit. This is a normal phenomenon.
There may be gentle “rustle” sound when the Walls, carpet, furniture or clothes indoors
unit starts or stops. It is the normal sound of may disseminate peculiar smell.
flowing refrigerant.
In order to protect the unit, when the In the first several minutes of heating
compressor stops, there will be a 3-minute operation, wind may not come out from the
delay before restarting indoor unit.
Water may flow out from the outdoor unit In heating operation, steam may come out
during heating operation. when it is defrosting.
-21-
INSTALLATION MANUAL
〖Installation Guide〗
This air conditioner meets the safety and operation standards promulgated by the Nation.
You need to invite professional air conditioner service and maintenance personnel to install or
remove the air conditioner. Problems may occur and you may suffer losses if non- professionals
install the air conditioner.
User shall provide the power that meets installation and operation requirements. please refer to
nameplate for details about the voltage for this product. Voltage beyond this scope will affect the
normal operation of the air conditioner.
Separate power point with delay fuse protector or automatic breaker should be used for the air
conditioner.
The air conditioner must be correctly and reliably grounded, or it may cause electric shock or fire.
Do not switch on the power of the air conditioner before well connecting and carefully checking the
tubing and wires.
The appliance shall not be installed in laundry or bathroom.
In case necessary, please consult your supply authority for system information.
The plug shall be accessible after installed the appliance.
This instruction is subject to change without notice.
〖Installation of Accessories〗
Examine carefully the attached packing list and check whether the accessories are complete.
Users may need to buy at their own expenses the articles not included in the packing list and may be
needed in installing.
good ventilation.
Good discharge for water.
At least 1m away from wireless equipment (such
as TV, radio etc.).
Fig.1
Mounted on the wall that can bear the weight of
the air conditioner and won't produce noise while
unit working.
The distance between the indoor unit and the floor should be greater than 2.3m.
The plug shall be accessible after installing the appliance.
Ensure the distance as required in Fig.1.
The back of the indoor unit should be close to the wall(Fig.1)
The all figures are only schematic, and they may be slightly different from the actual appliances you
selected.
At least 10cm
At least At least
Air inlet
Air outlet
15cm 40cm
Outdoor unit
Blackage
At least 2m
Fig.2
〖Tubing Selection〗
Ensure that the level (height) difference of indoor and outdoor units and the length of tubing meet the
requirement In the Table 1.
If the tubing is longer than 7m, but shorter than 15m, refrigerant should be supplemented according
to Table 1.
Indoor unit
Height Outdoor unit
difference
Indoor unit
Outdoor unit
Fig.3
Table 1
Tubing Size Standard tubing Max tubing Height Additional
Narrow (mm) Wide (mm) Length (m) Length (m) Difference (m) refrigerants(g/.m)
PVC tube
Wall cap
Small angle
Fig.5
Notes: Left chart is available for the position of drain hose, refer to Fig.7.
Right chart is available for the position of drain hose, refer to Fig.9.
Fig.4
〖Indoor Unit Installation〗
The tube may be connected in several directions as below shown Figures.
1. Connecting right back tube (similar to right lower tube) (Optional,
Refer to Fig.7) Pipeline
Pull out the tubing from bottom of the chassis; and connect the
drainpipe. Strap the joint of tubing reliably.
Lead the connecting wire to the indoor unit (Do not connect to
the power).
Strap together the tubes, discharge pipe and connecting wire
with adhesive tape. The discharge pipe is put at the below.
Drain pipe
Remove the board which is on the chassis. Units connecting wires
Check if the connections are reliable. Fig.6
Mount the indoor unit on the two hooks at the upper part of installation board.
2. Connecting left back tube (similar to left lower tube). (Optional, Refer to Fig9)
Move the discharge tube to the left side, and discharge cap to the right side.
Fix the tubes in the slot of the indoor unit with the fix clamp.
The following mounting steps are the same as those in “1. Connecting right back tube.”
Drain hose
Wall
Installation
board
Leftward
Rightward
Fixed clamp
Leftback
Rightback
Downward Fig.7
Fig.8
Drain hose
Installation support
Fig.10
〖Tubing Connection〗
Detach the valve cover of outdoor unit.
Align flaring nut to the thread center, and screw the nut tightly by hand.
Screw tightly the flaring nut with torque spanner until the torque spanner produces "click” sound.
It is recommended to use torque spanner to connect the tubing. If other flexible or fixed spanner is
used, it may damage the horn mouth due to improper force.
The bending angle of the tube should not be too small or the tube may break up, so the service
personnel should use tube bender to bend the tube.
Never let water, dust or sand gets into the pipe. Table 2
Torque
Tubing size (mm)
(N. m)
Thread Flaring nut Pipeline
ф6.35 (1/4”) 15~20
ф9.52(3/8”) 35~40
Wrench
ф12.7(1/2”) 50~55
Torque Wrench
ф15.88(5/8”) 68~82
Fig.11
〖Connection of Wires〗
Electric cover
1. Indoor unit
Open upward the inlet grid to the greatest extends.
Remove the electric cover from the unit.
Loose the screw at connection lid. (Fig.12)
Dismantle the wire pressure plate.
Connect the power connecting wires and signal control
wire separately to the corresponding terminals. (In Fig.14, Fig.12
please choose the same wiring diagram just with the wiring diagram of unit .)
Loose off the screw on the earth plate; press earth wire tightly.
Press tightly the connecting wires of the unit with lead wire pressure plate.
Close the connection lid screw it tightly and close the inlet grid.
2. Outdoor unit
Unscrew and dismantle the electronic device lid(Fig.13).
Dismantle the pressure plate of wire fastener.
Connect the connecting wires of the unit separately to the
corresponding terminals. (Fig.14)
Press tightly the connecting wires of the unit with top pressure
plate.
Remount the electronic device lid to the original position.
If user wants to prolong or replace the power wire, please do it
according to Screw
the table(Table3).
Fig.13
Table 3
Power connecting Signal control Power cord
wires wire
Max. Length 10m 10m 5m
7K/9K/12K/16K ≥2.5 mm 2
≥1.5 mm 2
≥1.5mm2
Cross sectional
18K/21K/24K/28K area ≥2.5 mm2 ≥1.5 mm2 ≥2.5 mm2
7K/9K/12K/16K
9
K
/
1
2
K
/
1
8
K
/
2
4
K
D
C
I
n
v
e
r
t
e
r
18K
Brown
1 1
2
Gray 2
N N
Yellow/Green Yellow/Green 3
Yellow/Green 3
4 Black 4
Blue Blue
5
Brown Brown
21K/24K/28K
Brown
Brown
1 L L 1
Blue
2 N Blue N 2
Yellow/Green Yellow/Green
3 3
4 L1 Black L1 4
Fig.14
Notes:
Earthing screw must use special screw(stainless machining screws or copper screws M4)
Ensure that all wires are securely connected, will not loose or separate.
Ensure that wire connections are carried out according to the wiring diagram of the air conditioner.
The above figures are only schematic, and they may be slightly different from the actual appliances
you select.
〖Tube Strapping〗
Strapping with PVC Protective tape must be careful, do not damage the pipeline and drain pipe.
Strapping should start from the lower part of the outdoor unit to the indoor unit.
Fix the PVC tape with adhesive tape to prevent loosing.
Drainpipe should slightly slide down outwards to ensure drainage well.
When the indoor unit is lower than the outdoor unit, bend the tube to proper extent to prevent water
draining into house.
Fix the tube bundle with tube clamps on the wall.
Allow enough space between discharge pipe and the ground. Do not put the discharge pipe in water
or ditch.
Seal the external wall holes with sealing gum or putty.
Wall
Clamp
PVC protective tape
Fig.15
〖Exhaust〗
1. Exhausting type
Make sure that all the tubes of indoor and outdoor unit are connecting well.
Take off valve bonnet and service port valve bonnet from two-port valve (small pipe cut-off valve) and
three-port valve (large pipe cut-off valve).
Turn counter-clockwise 1/4 turn the spool of two-pot valve, close after 10 seconds.
To check whether there are leakage at all connections.
If there is no leakage, turn again two-port valve counter-clockwise 1/4 turn, at the same time hold out
against the exhaust from valve inside of service port of three-port valve for 10 seconds.
Open two-port and three-port valves for running.
Screw tightly the valve bonnet.
Check with soap water or leak detector whether there are leakage at all indoor and outdoors’
connections.
Put the valve bonnet and valve cover back to the position.
Narrow tube
Wide tube
Open
2. Pumping type
Make sure that all the tubes of indoor and outdoor unit are connecting well.
Take off valve bonnet from two-way and three-way valves by spanner; connect vacuum pump and
compound valve to the service valve bonnet.
Open the low-pressure switch of compound valve, and run vacuum pump until units’ internal
pressure at 10 mmHg.
After pump vacuum, close the low-pressure switch of compound valve, and then close vacuum
。
pump. Turn anti-clockwise 90 Spool of narrow pipe service valve by hexagon spanner, tightly with
clockwise turning after stopping for 10 seconds.
Check with soap water or leak detector whether there is leakage at all connections of indoor and
outdoor unit.
Open wide and narrow pipe service valves by hexagon spanner for running.
Take off the connection pipeline of wide pipe service valve.
Screw tightly the entire valve bonnet by torque spanner.
Check with soap water or leak detector whether there are leakage at all indoor and outdoors’
connections.
Put the valve bonnet and lid back to position.
Fig.17
〖Drainage〗
1. No need drainage treatment
In regions where become cold in the winter, don't install the drain elbow joint to prevent drain water
from freezing and causing the fan to be damaged. This drainage treatment is not necessary for
cooling-only type air conditioner.
2. When need drainage treatment
Please use drain elbow joint (in accessory bag). Outdoor unit should be placed on blocks.
Chassis (outdoor)
Elbow joint
Drain pipe
(buy it by user)
Fig.18
Installation for the cover of valve(Optional):
For the whole unit that individual cover of valve is available (refer to packing list), the
installing method is as follow:
After connecting the connection pipes between indoor and outdoor units followed by the
installing method mentioned above, take out the cover of valve from the accessory bag,
and fix it on the side of outdoor unit with three corresponding screws ( inside the accessory
bag ).
JUZ3.867.10453