Float Valve: (Sizes 1/2"-6" / 15 - 150 MM)
Float Valve: (Sizes 1/2"-6" / 15 - 150 MM)
Float Valve: (Sizes 1/2"-6" / 15 - 150 MM)
Float Valve
• Accurate and Repeatable Level Control
• On-Off or Non-Modulating Action
• Fully Adjustable High and Low Level Settings
• Simple Design, Proven Reliable
• Easy Installation and Maintenance
The Cla-Val Model 124-01 Float Valve is a non-modulating valve that accurately
controls the liquid level in tanks. This valve is designed to open fully when the
liquid level reaches a pre-set low point and close drip-tight when the level
reaches a preset high point.
This is a hydraulically operated, diaphragm valve with the pilot control and float
mechanism mounted on the cover of the main valve. The float positions the pilot
control to close the valve when the float contacts the upper stop. The high and
low liquid levels are adjusted by positioning the stop collars on the float rod. The
difference between high and low levels can be adjusted to as little as 1" (25 mm),
or to as much as 18" (450 mm).
Level settings can be as much as eleven and one half feet below the valve. The
Schematic Diagram float mechanism may be located remotely from the main valve. See the technical
data sheet on Model CF1-C1 Float Control for additional information.
Item Description
1 100-01 Hytrol Main Valve
2 CF1-C1 Float Control
Optional Features
Item Description
A X46A Flow Clean Strainer
B CK2 Isolation Valve
C CV Flow Control (Closing)
F Independent Operating Pressure
P X141 Pressure Gauge
S CV Speed Control (Opening)
V X101 Valve Position Indicator
Y X43 "Y" Strainer
Materials
Component Standard Material Combinations Z
Body & Cover Ductile Iron Cast Steel Bronze
Available Sizes (inches) 1
⁄2" - 6" 1
⁄2" - 6" 1
⁄2" - 6"
B (Diameter) B (Diameter)
J J
100-01 100-01
Threaded & Grooved
Flanged K K
X
H H CC
C (MAX)
(MAX)
G E F EE
GG FF GGGG
GGG
Inlet D Inlet DDDD
A DD
DDD Z Y AAAA
AA
AAA
Pattern G G G, A G, A G, A G, A G, A G, A G, A G, A
Main Valve
100-01 T, F, T, F, T, F, T, F, F, F,
End Detail T T T T
Gr* Gr Gr* Gr Gr Gr*
Suggested Maximum 19 33 55 93 125 210 300 460 800 1800 See the 124-02/624-02 Technical Data Sheet
Flow for larger sizes.
Maximum
(gpm) Intermittent 24 42 68 120 160 260 370 580 990 2250
Suggested Maximum 1.2 2.1 3.5 6 8 13 19 29 50 113
Flow
Maximum
(Liters/Sec) Intermittent 1.5 2.6 4.3 7.6 10 16 23 37 62 142
100-01 Series is the full internal port Hytrol. *Globe Grooved Only
1701 Placentia Ave • Costa Mesa CA 92627 • Phone: 949-722-4800 • Fax: 949-548-5441 • E-mail: info@cla-val.com • www.cla-val.com
CLA-VAL © Copyright Cla-Val • Printed in USA • Specifications subject to change without notice. E-124-01 (R-04/2022)