Mobile Power
1800 RPM Diesel
Made in USA
Generator available
with or without trailer
Options
■ Block heater ■ Electric brakes
■ Battery charger ■ 2" or 2-5/16" ball hitch coupler
■ Shore power inlet for easy connection to block ■ Automatic transfer switches
heater or battery charger ■ Generator without trailer
Generator Specifications – Preliminary Receptacle Specifications
Standby Output 150oC Rise kVA/kW 120 Volt 20 Amp Duplex GFCI . . . . . . . . . . . . . . . . . . . 4
Single phase @ 240V . . . . . . . . . . . . . . . . . . . 100/100 120/240 Volt 50 Amp Twistlock (CS6369) . . . . . . . . . . . 4
3 phase @ 208V . . . . . . . . . . . . . . . . . . . . . . . 169/135 Two wire remote start capability . . . . . . . . . . . . . . . . Yes
3 phase @ 240V . . . . . . . . . . . . . . . . . . . . . . . 169/135
3 phase @ 480V . . . . . . . . . . . . . . . . . . . . . . . 188/150 Fuel System Specifications
Prime Output 105oC Rise kVA/kW
Single phase @ 240V . . . . . . . . . . . . . . . . . . . . . 90/90 Fuel Consumption Standby Rating GPH
3 phase @ 208V . . . . . . . . . . . . . . . . . . . . . . . 138/110 1/2 load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.6
3 phase @ 240V . . . . . . . . . . . . . . . . . . . . . . . 156/125 Full load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.5
3 phase @ 480V . . . . . . . . . . . . . . . . . . . . . . . 156/125 Approximate Run Time Hours
Amperage (Standby Rating) Amps 1/2 load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Single phase amperage @ 240/120V . . . . . 416/2X416 Full load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
3 phase amperage @ 208V . . . . . . . . . . . . . . . . . . 468 Fuel Capacity
3 phase amperage @ 240V . . . . . . . . . . . . . . . . . . 406 Gallons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210
3 phase amperage @ 480V . . . . . . . . . . . . . . . . . . 225 Fuel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Diesel
Voltage-3 phase adjustable 208/220/240/416/440/460/480
Voltage-Single phase adjustable 120/127/139/240/254/277
3 phase Power Factor . . . . . . . . . . . . . . . . . . . . . . . 0.8 Weights and Dimensions
Voltage Regulation . . . . . . . . . . . . . . . . . . . . . . . . 1/2%
Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Hertz Weight without fuel . . . . . . . . . . . . . . . . . . . . . . . . 6385
Total Harmonic Distortion . . . . . . . . . . . . . . . . . . < 5% Weight without fuel and without trailer . . . . . . . . 5390
Insulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Class H Dimensions with trailer (L x W x H) . . 178” x 75” x 98”
Dimensions without trailer (L x W x H) 130” x 48” x 81”
Engine Specifications
Sound Level
Manufacturer . . . . . . . . . . . . . . . . . . . . . . . . . John Deere
Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6068HF285 Sound level dB(A) . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Cylinders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 7 meters, full load
Induction system . . . . . . . . . . . . . . . . . . . . Turbocharged
Displacement, L (cu. in.) . . . . . . . . . . . . . . . . . . . 6.8L (415)
EPA Emissions Level . . . . . . . . . . . . . . . . . . . . . . . . . Tier 3 Other Features
HP @ rated speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211
RPM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1800 Start/Stop/Auto Switch, Alarm Horn, Voltage Adjust
Bore and stroke . . . . . . . . . . . . . . . . . . . . . . . . 4.2” x 5.0” Pot, Battery Disconnect Switch, Trailer Side Markers
Lubrication capacity (with filter) . . . . . . . . . . . . . . . . 34 Qts and Running Lights.
Battery recommendation (min. cold cranking amps) . . . . 925
- Battery, battery rack and cable supplied
- Spin-on oil filter
- Thermostat controlled liquid cooling system
- 12V engine alternator
- 12V starter motor
Ratings: - Standby Ratings: Standby ratings are applicable for supplying emergency power for the duration of a utility power outage.
No overload capability for standby rating. Standby ratings in accordance with ISO 3046, BS55114, DIN 6271. Prime Power Rating:
Prime power is the maximum power available for continuous duty. A 10% overload capacity is available for 1 hour out of 12 hours of
operation. Manufacturer reserves the right to implement specifications or design changes without notice. WARNING: Do not connect
generator to any building’s electrical system unless a disconnect switch has been installed.