Untitled
Untitled
Untitled
1
Bill of Quantities
SUPPLEMENTARY PREAMBLES
Provisional:
Nature of ground:
1 Allow for clearing the area of the site to be built upon of all
grass, weeds, shrubs, trees with trunks not exceeding
200mm girth, debris, etc., including grubbing up all roots, m² 801.00
scuffling up as required and cart away all vegetation and
debris.
3 Trenches. m³ 101.00
12 Keep excavations free of all water other than subterranean Item 1.00
water.
SUPPLEMENTARY PREAMBLES
Cost of tests:
Formwork:
UNREINFORCED CONCRETE
15MPa/19mm Concrete:
25 MPa/19mm Concrete:
30MPa/19mm concrete
5 Surface beds on waterproofing m³ 36.00
Annexure A
4
Bill of Quantities
30 MPa/19mm Concrete:
TEST BLOCKS
Test blocks:
CONCRETE SUNDRIES
11 Edges, risers, ends and reveals not exceeding 300mm high. m 77.00
Saw-cut joints:
REINFORCEMENT (PROVISIONAL)
Fabric reinforcement
Sizes in descriptions:
Where sizes in descriptions are given in brick units, 'one
brick' shall represent the length and 'half brick' the width of a
brick.
Hollow walls etc:
Descriptions of hollow walls shall be deemed to include
leaving every fifth perpend of the bottom course of the
external skin open as a weep hole.
BRICKWORK IN FOUNDATIONS
Brickwork of NFX bricks (14 MPa nominal compressive
strength) in Class I mortar:
1 One brick walls. m² 32.00
3 280mm Hollow walls of two half brick skins including wire m² 108.00
ties.
BRICKWORK IN SUPERSTRUCTURE
Brickwork of NFX bricks (14 MPa nominal compressive
strength) in class II mortar
4 Half brick walls m² 262.00
6 280mm Hollow walls of two half brick skins including wire m² 395.00
ties.
BRICKWORK SUNDRIES
Brickwork sundries:
7 Splayed mortar fillet one course high in 50mm cavity. m 167.00
Brickwork reinforcement:
SUPPLEMENTARY PREAMBLES
Waterproofing:
ROOF INSULATION
40mm High density Isoboard insulation:
SUPPLEMENTARY PREAMBLES
Joinery:
Fixing:
Sawn softwood
ROOF SUNDRIES
Sundries:
FLOORS ETC
Cork flooring:
Wrought hardwood:
DOORS
8 40mm Door 813 x 2 032mm high (type J dwg no. W-6109). No 33.00
SUPPLEMENTARY PREAMBLES
Fixing
Ceilings
INSULATION
NAILED-UP CEILINGS
FLOOR COVERINGS
SUPPLEMENTARY PREAMBLES
1 On floors m² 146.00
Annexure A
14
Bill of Quantities
SUPPLEMENTARY PREAMBLES
Finishes to ironmongery
LOCKS
DORMAKABA' or equvalent:
1 65mm Five pin Euro profile knob cylinder key to differ (code
DKC056501KD). No 19.00
4 Narrow stile heavy duty roller dead lock (code D07935 SS). No 5.00
UNION' or equivalent:
HANDLES
Union' or equivalent:
Annexure A
15
Bill of Quantities
DOOR CLOSERS
DORMAKABA' or equivalent:
SUNDRIES
DORMAKABA' or equivalent:
23 Rebate conversion kit for Euro profile locks (code D038R NP) No 1.00
BATHROOM ACCESSORIES
DORMAKABA' or equivalent:
24 Hat and Coat Hook with rubber buffer (code DHC-SS-031B). No 4.00
BUDGETARY ALLOWANCES
Sundries:
Bolts:
SUPPLEMENTARY PREAMBLES
All aluminium door and window frame sizes and sections are
to be approved by the architect prior to commmencent of
sub-contract work. Epoxy powder coated framed will be to
the colour specified by the architect from the manufacturer's
standard colour chart.
BUDGETARY ALLOWANCES
SCREEDS
INTERNAL PLASTER
4 On walls. m² 844.00
EXTERNAL PLASTER
7 On walls. m² 387.00
SUPPLEMENTARY PREAMBLES
Fixing
WALL TILING
1 On walls m² 23.00
SUPPLEMENTARY PREAMBLES
Sealing of edges
Copper pipes
Fixing of pipes
RAINWATER DISPOSAL
Aluminium downpipes.
SOIL DRAINAGE
Gulleys:
Inspection chambers:
11 Excavate for and build manhole with one brick sides in extra
hard stock bricks in (1:3) cement mortar on 150mm concrete
Class 20 bottom projecting 150mm all round, rendered
internally in (1:3) cement plaster with brickwork cobbled to
suite cast iron manhole cover and frame (elsewhere
measured) the bottom benched up in fine concrete Class 20 No 2.00
finished smooth in (1:11) cement plaster (channels elsewhere
measured), including all necessary formwork, reinforcing etc.
Size internally 450 x 600mm and not exceeding 1 m deep
from invert, including all necessary formwork, reinforcing, etc
Sundries:
SANITARY FITTINGS
17 530 x 410mm 'Metis' white wall hung basin with tap hole
complete to manufacturer's specifications. No 4.00
TRAPS ETC
E Space trap:
20 Double bowl sink trap including extension piece fitted under No 1.00
sink.
Stylux' or equal and approved:
Tivoli' or equivalent:
SANITARY PLUMBING
Testing
WATER SUPPLIES
BUDGETARY ALLOWANCES
SUPPLEMENTARY PREAMBLES
1 On walls. m² 853.00
3 On walls. m² 457.00
One coat primer and two coats polyurethane paint for interior
use:
5 On floors. m² 84.00
One coat plaster primer and two coats 'Plascon Polvin Super
Acrylic' paint, or equivalent, for exterior use:
ON METAL SURFACES
ON WOOD SURFACES
9 On doors. m² 71.00
11 On flooring. m² 41.00
Annexure A
30
Bill of Quantities
EXTERNAL WORKS
1 Trenches. m³ 18.00
15MPa/19mm Concrete:
Reinforcement:
12 On walls. m² 29.00
Apply one coat Plascon plaster primer and two coats Plascon
Wall & All or equivalent paint for exterior use on:
13 On walls. m² 29.00
BUDGETARY ALLOWANCES
PROVISIONAL SUMS
Electrical Installation:
Joinery Installation:
PROVISIONAL AMOUNT
Builders Work:
SUPPLEMENTARY PREAMBLES
Provisional:
Nature of ground:
1 Allow for clearing the area of the site to be built upon of all
grass, weeds, shrubs, trees with trunks not exceeding
200mm girth, debris, etc., including grubbing up all roots, m² 143.00
scuffling up as required and cart away all vegetation and
debris.
3 Trenches. m³ 23.00
CARTING AWAY.
SUPPLEMENTARY PREAMBLES
Cost of tests:
Formwork:
UNREINFORCED CONCRETE
15MPa/19mm Concrete:
30MPa/19mm concrete
4 Surface beds on waterproofing m³ 6.00
TEST BLOCKS
Test blocks:
CONCRETE SUNDRIES
REINFORCEMENT (PROVISIONAL)
Fabric reinforcement
Sizes in descriptions:
BRICKWORK IN FOUNDATIONS
1 280mm Hollow walls of two half brick skins including wire m² 33.00
ties.
BRICKWORK IN SUPERSTRUCTURE
2 280mm Hollow walls of two half brick skins including wire m² 113.00
ties.
BRICKWORK SUNDRIES
Brickwork sundries:
Brickwork reinforcement:
BRICK PAVING
Annexure A
38
Bill of Quantities
SUPPLEMENTARY PREAMBLES
Waterproofing:
ROOF INSULATION
6 Laid taut over purlins and fixed concurrent with roof covering;
overlapped longitudinally by 100mm; on and including m² 64.00
galvanised straining wires.
Annexure A
40
Bill of Quantities
SUPPLEMENTARY PREAMBLES
Joinery:
Fixing:
Wrought hardwood:
ROOFS ETC
Sawn softwood
ROOF SUNDRIES
Sundries:
Annexure A
41
Bill of Quantities
SUPPLEMENTARY PREAMBLES
Fixing
Ceilings
NAILED-UP CEILINGS
Sundries:
Bolts:
SUPPLEMENTARY PREAMBLES
GARAGE DOORS
INTERNAL PLASTER
1 On walls. m² 85.00
EXTERNAL PLASTER
3 On walls. m² 125.00
RAINWATER DISPOSAL
Aluminium downpipes.
1 On walls. m² 85.00
2 On walls. m² 127.00
One coat plaster primer and two coats 'Plascon Polvin Super
Acrylic' paint, or equivalent, for exterior use:
ON WOOD SURFACES
5 On backs of frames, linings, etc not exceeding 300mm wide m 32.00 24.36
Annexure A
47
Bill of Quantities
ELECTRICAL PORTION
MAIN BUILDING - SMALL POWER & LIGHTING
REQUIREMENTS
29 Cutting and pulling back of existing fibre optic cable and re- m 32
routing thereof through new cable sleeves (measured
elsewhere)
CARRIED FORWARD
b/f
Annexure A
49
Bill of Quantities
CIVIL WORKS
Excavate in soft rock for trenches, backfill and compact,
including removal of surplus/unsuitable materials to spoil off
site for trenches 0.6m wide and for depth:
1 Up to 0.6m deep m 218
2 Extra over item B.4.1.1 for excavation in soft rock cu.m 15.696
3 Extra over item B.4.1.1 for excavation in hard rock material cu.m 3.924
4 Extra over item B.4.1.1 for excavation through paved m 5
roadway and reinstating afterwards
5 Extra over item B.4.1.1 for imported backfill materials cu.m 26.16
Supply, install and bed 50mm PAC KABLE FLEX cable sleeve in
trench complete with danger tape(trenching measured elsewhere)
6 Straight Lengths m 60
7 Long Radius Bends No 10
8 Supply and install Non metallic draw wires in all cable sleeves m 60
CARRIED FORWARD
b/f
Annexure A
51
Bill of Quantities
CARRIED FORWARD
b/f
Annexure A
54
Bill of Quantities
PROVISIONAL SUM
Provision for additional work as may be required PC Sum 30000 30000
CARRIED FORWARD
b/f
Annexure A
55
Bill of Quantities
8 25mm² x 3 core m 65
9 16mm² x 4 core m 1 Rate Only
CARRIED FORWARD
Annexure A
56
Bill of Quantities
5 Supply, install and bed 50mm PAC KABLE FLEX cable sleeve in
trench complete with danger tape(trenching measured elsewhere)
6 Straight Lengths m 5
7 Long Radius Bends No 2
8 Supply and install Non metallic draw wires in all cable sleeves m 5
CARRIED FORWARD
b/f
Annexure A
58
Bill of Quantities
GARAGE ACCESSORIES
Supply and installation of the following, inclusive of mounting
hardware.
PROVISIONAL SUM
1 Provision for additional work as may be required PC Sum 5000 5000
CARRIED FORWARD
b/f
Annexure A
60
Bill of Quantities
EGA Duct
1 100mm x 40mm m 1 Rate Only
2 100mm x 40mm End Cap No 1 Rate Only
3 100mm x 40mm Elbow No 1 Rate Only
4 16mm x 16mm m 1 Rate Only
5 16mm x 16mm End Cap No 1 Rate Only
6 16mm x 16mm Elbow No 1 Rate Only
7 16mm x 16mm Coupling No 1 Rate Only
8 16mm x 16mm Tee No 1 Rate Only
9 40mm x 40mm m 1 Rate Only
10 40mm x 40mm End Cap No 1 Rate Only
11 40mm x 40mm Elbow No 1 Rate Only
PVC Wire
12 1.5mm² x 1 core m 1 Rate Only
13 2.5mm² x 1 core m 1 Rate Only
14 4mm² x 1 core m 1 Rate Only
15 6mm² x 1 core m 1 Rate Only
Cable
16 1.0mm² x Twin and Earth m 1 Rate Only
17 1.5mm² x Twin and Earth m 1 Rate Only
18 2.5mm² x Twin and Earth m 1 Rate Only
19 1.5mm² x 2 core + Earth Surfix m 1 Rate Only
20 2.5mm² x 2 core + Earth Surfix m 1 Rate Only
21 1.5mm² x 3 core SWA cable m 30 Rate Only
22 2.5mm² x 3 core SWA cable m 30 Rate Only
PVC Boxes
39 20mm 4 way shallow No 1 Rate Only
40 25mm 4 way shallow No 1 Rate Only
Galvanised Boxes
41 20mm 4 way shallow No 1 Rate Only
42 25mm 4 way shallow No 1 Rate Only
Plug Tops
47 16 amp Normal No 1 Rate Only
48 16 amp Dedicated No 1 Rate Only
PROVISIONAL SUM
49 Provision for additional network equipment as may be PC Sum 15000 15000
required
Description Cost
SECTION NO. 1 : OFFICES
BILL NO.1 : EARTHWORKS
BILL NO.2 : CONCRETE, FORMWORK AND REINFORCEMENT
BILL NO.3 : MASONRY
BILL NO.4 : WATERPROOFING
BILL NO.5 : ROOF COVERINGS
BILL NO.6 : CARPENTRY AND JOINERY
BILL NO.7 : CEILINGS PARTITIONS AND ACCESS FLOORING
BILL NO.8 : FLOOR COVERINGS
BILL NO.9 : IRONMONGERY
BILL NO.10 : METALWORK
BILL NO.11 : PLASTERING
BILL NO.12 : TILING
BILL NO.13 : PLUMBING AND DRAINAGE
BILL NO.14 : PAINTWORK
BILL NO.15 : EXTERNAL WORKS
BILL NO.16 : PROVISIONAL SUMS
ELECTRICAL PORTION
MAIN BUILDING - SMALL POWER & LIGHTING REQUIREMENTS
DISTRIBUTION BOARDS & EQUIPMENT
CABLES AND TERMINATIONS
EARTHING & BONDING
CIVIL WORKS
SWITCHES & SWITCHED SOCKET OUTLETS
POWER SKIRTING & ACCESSORIES
LIGHTING & ACCESSORIES.
AUDIO, VISUAL & SECURITY ACCESSORIES
PROVISIONAL SUM 30000