Bill of Quantities

Item Description Uom Qty Rate Amount


SECTION NO. 1 : OFFICES

BILL NO.1 : EARTHWORKS

SUPPLEMENTARY PREAMBLES

Provisional:

All work measured under this trade is provisional and subject


to re-measurement on site.

Nature of ground:

The nature of the ground is assumed to be loose sandy


material, therefore earth, but possibly interspersed with soft
or hard rock.
Carting away of excavated material:

Descriptions of carting away of excavated material shall be


deemed to include loading excavated material onto trucks
directly from the excavations or, alternatively, from stock piles
situated on the building site.

SITE CLEARANCE, ETC.

Site clearance, etc.:

1 Allow for clearing the area of the site to be built upon of all
grass, weeds, shrubs, trees with trunks not exceeding
200mm girth, debris, etc., including grubbing up all roots, m² 801.00
scuffling up as required and cart away all vegetation and
debris.

REMOVAL OF TREES ETC

Cutting down and removing, grubbing up roots and filling in


holes
2 Tree exceeding 200mm and not exceeding 500mm girth No 3.00
EXCAVATION OTHER THAN BULK

Excavation in earth not exceeding 2m deep:

3 Trenches. m³ 101.00

4 Thickening under surface beds etc m³ 7.00

Extra over excavations other than bulk in earth for excavation


in:
5 Soft rock. m³ 10.00

6 Hard rock. m³ 5.00

Risk of collapse of excavations other than bulk:

7 Sides of trench and hole excavations not exceeding 1,5m m² 289.00


deep.
Annexure A
2
Bill of Quantities

Item Description Uom Qty Rate Amount


CARTING AWAY.

Extra over all excavations for loading, carting and dumping


surplus excavated material (no allowance made for increase
in bulk):

8 To make up levels where directed on site. m³ 55.00

EARTH FILLING, ETC.

Filling with material from the excavations compacted to 98%


Mod. AASHTO density:

9 Backfilling to trenches, holes, etc. m³ 46.00

Filling with approved material supplied and carted onto site


by the Contractor, compacted to a density of at least 95%
Mod. AASHTO maximum density:

10 Under floors, pavings, etc. m³ 36.00

Filling with course river sand compacted to 98% Mod.


AASHTO density:

11 Under floors, pavings, etc m³ 18.00

KEEPING EXCAVATIONS FREE OF WATER

Keeping excavations free of water:

12 Keep excavations free of all water other than subterranean Item 1.00
water.

BILL NO.1 : EARTHWORKS - TOTAL


Annexure A
3
Bill of Quantities

Item Description Uom Qty Rate Amount


BILL NO.2 : CONCRETE, FORMWORK AND
REINFORCEMENT

SUPPLEMENTARY PREAMBLES

Cost of tests:

The costs of making, storing and testing of concrete test


cubes as required under clause 7 'Tests' of SABS 1200 G
shall include the cost of providing cube moulds necessary for
the purpose, for testing costs and for submitting reports on
the tests to the Architect. The testing shall be undertaken by
an independent firm or institution nominated by the
Contractor to the approval of the Architect. (Test cubes are
measured separately).

Formwork:

Descriptions of formwork shall be deemed to include use and


waste only (except where described as left in or permanent),
for fitting together in the required forms, wedging, plumbing
and fixing to true angles and surfaces as necessary to
ensure easy release during stripping and for reconditioning
as necessary before re-use.

The vertical strutting shall be carried down to such


construction as is sufficiently strong to afford the required
support without damage and shall remain in position until the
newly constructed work is able to support itself.

Formwork to sides of bases, pile caps, ground beams, etc.,


will only be measured where it is prescribed by the Engineer
for design reasons. Formwork necessitated by irregularity or
collapse of excavated faces will not be measured and the
cost thereof shall be deemed to be included in the allowance
for taking the risk of collapse of the sides of the excavations,
provision for which is made in Earthworks.

UNREINFORCED CONCRETE

15MPa/19mm Concrete:

1 Filling to cavity of hollow walls (provisional). m³ 6.00

2 Surface blinding under footings and bases. m³ 6.00

REINFORCED CONCRETE CAST AGAINST EXCAVATED


SURFACES

25 MPa/19mm Concrete:

3 Strip footings (provisional). m³ 25.00

4 Surface beds and thickenings on waterproofing


(waterproofing elsewhere). m³ 7.00

30MPa/19mm concrete
5 Surface beds on waterproofing m³ 36.00
Annexure A
4
Bill of Quantities

Item Description Uom Qty Rate Amount


REINFORCED CONCRETE

30 MPa/19mm Concrete:

6 Slabs including beams and inverted beams. m³ 10.00

7 Eyebrow slab. m³ 1.00

TEST BLOCKS

Test blocks:

8 Making and testing set of three 150 x 150 x 150mm concrete


strength test cubes (Provisional). Sets 12.00

CONCRETE SUNDRIES

Polished concrete with exposed aggregate seamless floor


finish:
9 Surface beds, slabs, etc m² 102.00

ROUGH FORMWORK (DEGREE OF ACCURACY II)

Rough Formwork to Sides:

10 Inverted beams m² 15.00

11 Edges, risers, ends and reveals not exceeding 300mm high. m 77.00

Rough Formwork to Soffits:

12 Slabs propped up exceeding 1,5m and not exceeding 3,5m m² 44.00


high
13 Cantilever slabs propped up exceeding 1,5m and not
exceeding 3,5m high m² 10.00

MOVEMENT JOINTS ETC

One layer of malthoid slip joints between horizontal concrete


and preformed cavity closure:

14 Not exceeding 300mm wide. m 34.00

Expansion joints with Jointex filler sheet, or equivalent,


between vertical brick surfaces:

15 10mm Joints not exceeding 300mm high to edge of surface m 26.00


bed.

1,6mm Galvanised sheet steel slip joints between horizontal


concrete and brick surfaces including cement mortar bed:

16 Not exceeding 300mm wide. m 34.00


Annexure A
5
Bill of Quantities

Item Description Uom Qty Rate Amount

Saw-cut joints:

17 6 x 40mm Saw-cut joints in top of concrete. m 1 358

REINFORCEMENT (PROVISIONAL)

Mild steel reinforcement to structural concrete work:

18 Bars of varying length and diameter. Tonnes 0.81

High tensile steel reinforcement to structural concrete work:

19 Bars of varying length and diameter. Tonnes 1.22

Fabric reinforcement

20 Type 193 fabric reinforcement in concrete surface beds etc m² 361.00

BILL NO.2 : CONCRETE, FORMWORK AND


REINFORCEMENT - TOTAL
Annexure A
6
Bill of Quantities

Item Description Uom Qty Rate Amount

BILL NO.3 : MASONRY


BRICKWORK

Sizes in descriptions:
Where sizes in descriptions are given in brick units, 'one
brick' shall represent the length and 'half brick' the width of a
brick.
Hollow walls etc:
Descriptions of hollow walls shall be deemed to include
leaving every fifth perpend of the bottom course of the
external skin open as a weep hole.

BRICKWORK IN FOUNDATIONS
Brickwork of NFX bricks (14 MPa nominal compressive
strength) in Class I mortar:
1 One brick walls. m² 32.00

2 One and a half brick walls m² 5.00

3 280mm Hollow walls of two half brick skins including wire m² 108.00
ties.
BRICKWORK IN SUPERSTRUCTURE
Brickwork of NFX bricks (14 MPa nominal compressive
strength) in class II mortar
4 Half brick walls m² 262.00

5 One brick walls m² 28.00

6 280mm Hollow walls of two half brick skins including wire m² 395.00
ties.
BRICKWORK SUNDRIES
Brickwork sundries:
7 Splayed mortar fillet one course high in 50mm cavity. m 167.00

8 Closing 50mm cavity of hollow wall horizontally with one


course of brickwork. m 139.00

9 Closing 50mm cavity of hollow wall vertically with brickwork


half brick wide. m 126.00

Brickwork reinforcement:

10 75mm Wide reinforcement built in horizontally. m 5 878

11 150mm Wide reinforcement built in horizontally. m 559.00

Prestressed fabricated lintels:

12 110 x 75mm Lintels in lengths not exceeding 3m. m 67.00

13 110 x75mm Lintels in lengths exceeding 3m and not


m 11.00
exceeding 4,5m

14 150 x 75mm Lintels in lengths not exceeding 3m. m 35.00

15 150 x75mm Lintels in lengths exceeding 3m and not


m 11.00
exceeding 4,5m

BILL NO.3 : MASONRY - TOTAL


Annexure A
7
Bill of Quantities

Item Description Uom Qty Rate Amount

BILL NO.4 : WATERPROOFING

SUPPLEMENTARY PREAMBLES

Waterproofing:

Waterproofing of roofs, basements, etc., shall be laid under a


ten year guarantee. Waterproofing to roofs shall be laid to
even falls to outlets etc with necessary ridges, hips and
valleys. Descriptions of sheet or membrane waterproofing
shall be deemed to include additional labour to turn-ups and
turn-downs.

DAMPPROOFING OF WALLS AND FLOORS

One layer of Brikgrip 375 type B laminated damp proof


course:
1 In walls. m² 100.00

2 Wrapped around ends of rafters built into walls (Provisional). m² 29.00

One layer of USB Green 250 type C laminated sheeting


sealed, or equivalent, at laps with pressure sensitive tape:

3 Under surface beds. m² 361.00

Sika Cemflex, or equivalent, waterproofing application


incorporating Cemflex fabric:

4 On shower floors including dressing up against walls, etc. m² 3.00

5 On shower walls. m² 23.00

WATERPROOFING TO ROOFS, BASEMENTS, ETC

One layer Derbigum SP4 waterproofing membrane, or


equivalent, with 75mm side laps and 100mm end laps,
sealed to primed surface to falls and crossfalls by 'torch-
fusion' finished laid under ten year guarantee by approved
installer to receive paint and stone protection (elsewhere).

6 On flat roofs m² 44.00

7 On tops and sides of inverted beams m² 30.00

8 Sealing edges to brickwork or concrete m 32.00

9 Flashing strip 150mm girth at turn-ups. m 32.00

10 Additional membrane at not exceeding 150mm diameter No 4.00


outlet.

PROTECTIVE STONE DRESSING


Clean crushed stone dressing free of pyrite or other
contaminants, of 20 - 25mm stone evenly spread with larger
stones around outlets
Annexure A
8
Bill of Quantities

Item Description Uom Qty Rate Amount

11 50mm Thick on waterproofing to flat roofs m² 44.00

PROTECTIVE ROOFING PAINT

Two coats bituminous aluminium paint

12 On waterproofing to roofs m² 44.00

JOINT SEALANTS, ETC.

Alcolin dual-component polisulphide sealing compound, or


equivalent, including backing cord, bond breaker, primer, etc:
13 6 x 40mm In saw-cut joints in floors (Provisional). m 1 358

14 10 x 15mm In expansion joints in floors including raking out


expansion joint filler as necessary. m 26.00
Annexure A
9
Bill of Quantities

Item Description Uom Qty Rate Amount

BILL NO.4 : WATERPROOFING - TOTAL

BILL NO.5 : ROOF COVERINGS

CORRUGATED METAL SHEETING AND ACCESSORIES

0.47mm/0.53mm Zincalume profile in Clean COLORBOND™


steel, metallic coating AZ150 minimum (150g/m2 ) coating
mass, Grade G550, super polyester paint system (colour
grey), 25um on topside and 10um on reverse side, or
equivalent.

1 Roof covering with pitch not exceeding 25 degrees. m² 276.00

2 Headwall Flash 308mm girth 1 times bent including serrated


closers and poly-closers. m 65.00

3 Sidewall Flash 308mm girth 1 times bent. m 25.00

4 Counter Flash 185mm girth 2 times bent. m 90.00

5 Valley gutter 616mm girth 4 times bent. m 38.00

6 Narrow and broad flute closers to suit curragated profile. m 12.00

ROOF INSULATION
40mm High density Isoboard insulation:

7 Insulation laid over purlins at nominal 2 400mm centres and


fixed concurrently with roof sheeting. m² 276.00
Annexure A
10
Bill of Quantities

Item Description Uom Qty Rate Amount

BILL NO.5 : ROOF COVERINGS - TOTAL

BILL NO.6 : CARPENTRY AND JOINERY

SUPPLEMENTARY PREAMBLES

Joinery:

Descriptions of frames shall be deemed to include frames,


transoms, mullions, rails, etc.

Descriptions of hardwood joinery shall be deemed to include


pelleting of bolt holes.

Fixing:

Items described as nailed shall be deemed to be fixed with


hardened steel nails or shot pins to brickwork or concrete.

PLATE NAILED TIMBER ROOF TRUSS CONSTRUCTION


ETC
SUPPLEMENTARY PREAMBLES

Trusses are at maximum 930mm centres

Roof coverings are on purlins.

Ceilings are 9mm Gypsum skimmed on 38 x 38mm


brandering
References given in descriptions refer to the respective types
of trusses detailed on the architect's/engineer's drawings
numbered C-0004 accompanying these bills of quantities for
tender purposes

Dimensions in descriptions of trusses are nominal and actual


measurements are to be obtained from the architect/engineer
and/or taken on site before design or fabrication commences

Sawn softwood

1 Roof construction to mono pitched roof with two valleys,


16,97 x 5,67m overall on plan x 1,5m high, including trusses,
jack rafters, permanent bracing, wall plates and 50 x 70mm Item 1.00
purlins at 915mm centres for roof covering.

2 Roof construction to mono pitched roof with two valleys,


20,19 x 9,62m overall on plan x 1,5m high, including trusses,
jack rafters, permanent bracing, wall plates and 50 x 70mm Item 1.00
purlins at 915mm centres for roof covering.
Annexure A
11
Bill of Quantities

Item Description Uom Qty Rate Amount

ROOF SUNDRIES

Sundries:

3 U-shaped galvanised mild steel bracket UH50/80 fixed to No 73.00


timber rafters.
4 30 x 1,2mm Galvanised hoop iron roof tie 600mm long with No 73.00
one end fixed to wood and other end built into brickwork.
EAVES, VERGES, ETC

Everite Nutec' medium density sheets:

5 12 x 225mm Plain fascia boards including 'Chromaprep' H-


profile jointing strips and corner jointers, or equivalent. m 13.00

FLOORS ETC

Cork flooring:

6 905 x 295 x 10.5mm WRT Amorim cork floor tiles 'Original


Rhapsody', or equivalent, with cork underlay, cut and sealed
complete fixed to floor as per manufacturers recommended m² 41.00
installation.

SKIRTINGS, CORNICES, ETC.

Wrought hardwood:

7 22 x 140mm Skirtings plugged (code WSK3), or equivalent. m 332.00

DOORS

Semi-solid flush doors with 32mm lining and flat architrave


trim surround:

8 40mm Door 813 x 2 032mm high (type J dwg no. W-6109). No 33.00

Semi-solid flush doors with 32mm lining and flat architrave


trim surround glazed with 6.38mm safety glass fixed to
brickwork/concrete:

9 40mm Glazed door 1 335 x 2 500mm high with 1 810 x 1


400mm high side window (Type F dwg no. W-6105). No 1.00

FRAMED DOORS ETC

Wrought meranti doors:

10 69 x 90mm Rebated frames, plugged m 13.00


Annexure A
12
Bill of Quantities

Item Description Uom Qty Rate Amount

BILL NO.6 : CARPENTRY AND JOINERY - TOTAL

BILL NO.7 : CEILINGS PARTITIONS AND ACCESS


FLOORING

SUPPLEMENTARY PREAMBLES

Fixing

Items described as 'nailed' shall be deemed to be fixed with


hardened steel nails or pins, or to be shot-pinned, to
brickwork or concrete

Items described as 'plugged' shall be deemed to include


screwing to fibre, plastic or metal plugs at not exceeding
500mm centres, and where described as 'bolted', the bolts
have been given elsewhere

Ceilings

Unless otherwise described ceilings shall be deemed to be


horizontal

INSULATION

Isotherm or similar approved insulation:

1 135mm Insulation closely fitted and laid on top of ceiling


between roof timbers etc. m² 276.00

NAILED-UP CEILINGS

9,5mm Gypsum plasterboard with taped joints and the whole


finished with gypsum plaster trowelled to a smooth polished
surface to the thickness recommended by the manufacturer

2 Ceilings including 38 x 38mm sawn softwood brandering at


450mm centres. m² 272.00

3 Vertical portion of bulkheads 150mm high, suspended not


exceeding 1m below ceiling. m 52.00

Prepainted metal cornices to ceilings:

4 25mm Shadowline cornices, plugged m 332.00


Annexure A
13
Bill of Quantities

Item Description Uom Qty Rate Amount

BILL NO.7 : CEILINGS PARTITIONS AND ACCESS


FLOORING - TOTAL
BILL NO.8 : FLOOR COVERINGS

FLOOR COVERINGS

SUPPLEMENTARY PREAMBLES

Floor coverings, wall linings, etc shall, where applicable,


include all preparatory work to screeded or plastered
surfaces etc, priming coats and adhesives as recommended
by the manufacturers of the flooring, linings, etc

500 x 500 x 7mm 'Belgotex Metro' heavy commercial [colour


to architect] 'Stainproof Miracle Fibre (Polypropylene) &
Stainproof Eco Fibre Blend™' structured needlepunch
'ResinBac®', or equivalent, resin backed carpet tiles:

1 On floors m² 146.00
Annexure A
14
Bill of Quantities

Item Description Uom Qty Rate Amount

BILL NO.8 : FLOOR COVERINGS - TOTAL

BILL NO.9 : IRONMONGERY

SUPPLEMENTARY PREAMBLES

Finishes to ironmongery

Where applicable finishes to ironmongery are indicated by


suffixes in accordance with the following list: BS Satin bronze
lacquered CH Chromium plated SC Satin chromium plated
SE Silver enamelled GE Grey enamelled AN Anodised
natural AS Anodised silver AB Anodised bronze AG
Anodised gold ABL Anodised black PB Polished brass PL
Polished and lacquered PT Epoxy coated SD Sanded

LOCKS

DORMAKABA' or equvalent:

1 65mm Five pin Euro profile knob cylinder key to differ (code
DKC056501KD). No 19.00

2 Cylinder sash lock (code D036S SS). No 14.00

3 Bathroom sash lock, case dimentions (mm) 102h x 78d,


forend dimentions (mm) 155h x 22w, backset 57mm centres No 3.00
(code D035S SS).

4 Narrow stile heavy duty roller dead lock (code D07935 SS). No 5.00

5 Narrow stile cylinder escutcheon (code DCE-105 SS). No 5.00

6 Lever handle on rose with cylinder Escutcheon (code TH125


Cyl SS) No 17.00

7 Flush bolt (code FBMF) No 2.00

8 160mm Manual flush bolt (code DFB-SS-027). No 1.00

9 300mm Manual flush bolt (code DFB-SS-028). No 1.00

10 Dust proof strike (code DPS-SS-032) No 3.00

UNION' or equivalent:

11 Helping hand indicator bolt for paraplegic WC (code 37651). No 1.00

HANDLES

Union' or equivalent:
Annexure A
15
Bill of Quantities

Item Description Uom Qty Rate Amount

12 400 x 30mm Offset Tubular pull handle including BTB fixing


sets (code DPH206 BTB). Pairs 7.00

13 325 x 25mm Straight Tubular pull handle flange fixing (code


DPH301B). Pairs 2.00

PUSH PLATES AND KICK PLATES

DORMAKABA' or equivalent Push plates, kick plates etc:

14 Stainless steel trolley plate 900mm x width of door 1.2mm


thickness, drilled and countersunk for screw fixing. No 1.00

DOOR CLOSERS

DORMAKABA' or equivalent door closers:

15 Regular arm (R&P EN 2-4) delayed action door closer (code


TS73V DC) No 1.00

LETTERS, NAMEPLATES, ETC.

DORMAKABA' or equivalent:

16 150 x 150mm Tea cup sign (code DSS-135 TC) No 1.00

17 150 x 150mm Male sign (code DSS-130 M). No 1.00

18 150 x 150mm Female sign (code DSS-131 F). No 1.00

19 150 x 150mm Male/Female sign (code DSS-132 M/F) No 1.00

20 150 x 150mm Disabled persons sign (code DSS-133 P). No 1.00

21 150 x 150mm Shower sign (code DSS-139 S). No 1.00

SUNDRIES

DORMAKABA' or equivalent:

22 Floor mounted door stop (code DDS-NP-018) No 18.00

23 Rebate conversion kit for Euro profile locks (code D038R NP) No 1.00

BATHROOM ACCESSORIES

DORMAKABA' or equivalent:

24 Hat and Coat Hook with rubber buffer (code DHC-SS-031B). No 4.00

Bathroom accessories installed complete as per


manufactures instructions:
Annexure A
16
Bill of Quantities

Item Description Uom Qty Rate Amount

25 750mm Classique double towel rail. No 1.00

26 Heritage slatted soap holder. No 1.00

27 Classique toilet paper holder. No 3.00

BUDGETARY ALLOWANCES

The following net sums are for work to be executed by the


principal contractor and or specialists and will be measured
on completion and priced in terms of the contract as directed
by the project manager and deducted in whole or part if not
required

28 Provide the amount of R 25 000.00 (Twenty Five Thousand


Rand Only) for new signage to be spent in whole or part or Item 1.00
omitted from the contract
Annexure A
17
Bill of Quantities

Item Description Uom Qty Rate Amount

BILL NO.9 : IRONMONGERY - TOTAL

BILL NO.10 : METALWORK

SUNDRY GALVANIZED STEELWORK

Sundries:

1 30 x 6mm Flat section thresholds with 5mm diameter bent


lugs each 75mm girth welded on at 300mm centres, including m 13.00
embedding in concrete.

Bolts:

2 12mm Diameter bolts. No 292.00

GALVANISED PRESSED STEEL DOOR FRAMES

1,2mm Rebated frames suitable for half brick walls

3 Frame for door 813 x 2 032mm high No 16.00

ALUMINIUM WINDOWS, DOORS, SHUTTERS, ETC.

SUPPLEMENTARY PREAMBLES

Aluminium doors, windows, etc

Descriptions include for all aluminium work, fixing in position,


fixings, glazing and sealing both sides complete.

Doors and windows shall comply with AAAMSA design


criteria. Glazing shall comply with SAGGA regulations. Glass
shall be laminated performance glass as shown on the
Glass
windowthickness shall complyappended
schedules/drawings with SAGGA regulations
to these bills of
irrespective of thicknesses shown on the
quantities (as described in the headings to window
schedules/drawings.
descriptions). Doors and windows shall be supplied
with protective tape and plastic and shall be removed only
once surrounding trades have been completed. For purpose
made windows and doors, refer to drawings annexed to
these bills of quantities.

The following certificates shall be provided prior to


commencement of site work:

1. A copy of the relevant AAAMSA Performance Test


Certificate from the manufacturer/contractor supplying the
architectural aluminium product.

2. A Certificate of Conformance confirming that anodising or


powder coating has been processed in accordance with
SANS 999 and SANS 1796 respectively.
Annexure A
18
Bill of Quantities

Item Description Uom Qty Rate Amount


3. A powder guarantee of not less than 15 years issued by
the powder manufacturer. The specific conditions contained
in this guarantee shall form part of the powder coating
process.
4. A Certificate of Conformance confirming that glazing has
been installed in accordance with SANS 0137, ensuring that
safety glazing materials have been installed in the mandatory
areas and that each individual pane of safety glazing
materials has been permanently marked.

5. A warranty from the manufacturer of the laminated safety


glass and/or hermetically sealed glazing units guaranteeing
the products against delamination and colour degredation for
a period of not less than five years.

All aluminium door and window frame sizes and sections are
to be approved by the architect prior to commmencent of
sub-contract work. Epoxy powder coated framed will be to
the colour specified by the architect from the manufacturer's
standard colour chart.

Unless otherwise stated on the annexed drawings, all


aluminium frames are to be a minimum of 34mm thick and
components are to have the following minimum widths:

Casements minimum 30.5mm

Sliders minimum 70mm

Doors minimum 76mm

Refer to attached Window and Shopfront schedules for


drawings of all aluminium work.

Powder coated aluminium windows glazed with 6,38mm


safety glass complete with subframes, ironmongery, sealing,
etc and fixing to brickwork or concrete:

4 600 x 800mm High top hung pivot window (Window Type D


dwg no. W-6203). No 3.00

5 600 x 900mm High side hung pivot window (Window Type I


dwg no. W-6208). No 2.00

6 Window 650 x 1 700mm high overall consisting of two sliding


sections (Window Type C dwg no. W-6202). No 2.00

7 Window 1 300 x 1 700mm high overall consisting of four


sliding sections with 1 815 x 1 300mm high shutters (Window No 9.00
Type A dwg no. W-6200).

8 Window 1 490 x 2 600mm high overall consisting of two


opening fanlights, and two fixed bottom windows (Window No 2.00
Type E dwg no. W-6204).
Annexure A
19
Bill of Quantities

Item Description Uom Qty Rate Amount

9 Window 1 955 x 2 600mm high overall consisting of two


opening fanlights, and two fixed bottom windows (Window No 2.00
Type F dwg no. W-6205).

Powder coated aluminium windows glazed with solar E-glass


or double glazing complete with subframes, ironmongery,
sealing, etc and fixing to brickwork or concrete:

10 Window 650 x 1 700mm high overall consisting of two sliding


sections with 1 815 x 650mm high shutters (Window Type B No 1.00
dwg no. W-6201).

11 Window 960 x 2 600mm high overall consisting of one


opening fanlight, and one fixed bottom window (Window No 1.00
Type G dwg no. W-6206).

12 Window 1 300 x 1 700mm high overall consisting of four


sliding sections with 1 815 x 1 300mm high shutters (Window No 5.00
Type A dwg no. W-6200).

13 Window 1 540 x 2 600mm high overall consisting of two


opening fanlights, and two fixed bottom windows (Window No 1.00
Type H dwg no. W-6207).

Aluminium doors glazed with 6.38mm safety glass fixed to


brickwork/concrete:

14 Glazed door 900 x 2 600mm high with opening fanlight (type


H dwg no. W-6105). No 1.00

15 Glazed double door 1 500 x 2 100mm high (type I dwg no.


W-6108). No 1.00

16 Glazed double door 3 260 x 2 400mm high overall consisting


of two fixed side windows. (Type D dwg no. W-6103). No 1.00

Aluminium doors glazed with Solar E-glass or double glazing


fixed to brickwork/concrete:

17 Glazed door 900 x 2 600mm high with opening fanlight (type


A dwg no. W-6100). No 1.00

18 Glazed swing door 900 x 2 600mm high with opening fanlight


(type G dwg no. W-6105). No 1.00

19 Sliding door 3 200 x 2 600mm high overall consisting of four


fanlights of equal size and four fixed sections of equal size. No 1.00
(Type B dwg no. W-6101).

20 Glazed double door 4 230 x 2 400mm high overall consisting


of four fixed side windows. (Type C dwg no. W-6102). No 1.00
Annexure A
20
Bill of Quantities

Item Description Uom Qty Rate Amount


Powder coated aluminium sliding shutters installed complete
as per manufactureres specification with subframes, sliding
mechanism, ironmongery, etc. fixed to brickwork or concrete:

21 Sliding shutter for 650 x 1 700mm high overall window


(Window type B dwg no. W-6201). No 1.00

22 Sliding shutter for 1 300 x 1 700mm high overall window


(Window type A dwg no. W-6200). No 14.00

BUDGETARY ALLOWANCES

The following net sums are for work to be executed by the


principal contractor and or specialists and will be measured
on completion and priced in terms of the contract as directed
by the project manager and deducted in whole or part if not
required

23 Provide the amount of R 20 000.00 (Twenty Thousand Rand


Only) for new shower door to be spent in whole or part or Item 1.00
omitted from the contract
Annexure A
21
Bill of Quantities

Item Description Uom Qty Rate Amount

BILL NO.10 : METALWORK - TOTAL

BILL NO.11 : PLASTERING

SCREEDS

Screeds of wood floated on concrete:

1 30mm Thick on floors and landings . m² 187.00

2 Average ±70mm thick on roof slab to falls and currents. m² 44.00

3 50 x 50mm Splayed fillet for turn-up of roofing. m 32.00

INTERNAL PLASTER

Compo plaster with gypsum skim on brickwork:

4 On walls. m² 844.00

5 On narrow widths. m² 34.00

Compo plaster with gypsum skim on concrete:

6 On concrete ceilings and beams. m² 18.00

EXTERNAL PLASTER

Compo plaster on brickwork:

7 On walls. m² 387.00

8 On narrow widths. m² 25.00

Compo plaster on concrete:

9 On eyebrow slab. m² 20.00

10 On concrete beams. m² 26.00


Annexure A
22
Bill of Quantities

Item Description Uom Qty Rate Amount

BILL NO.11 : PLASTERING - TOTAL

BILL NO.12 : TILING

SUPPLEMENTARY PREAMBLES

Fixing

Unless described as 'fixed with adhesive to plaster (plaster


elsewhere)' descriptions of tiling on brick or concrete walls,
columns, etc shall be deemed to include 1:4 cement plaster
backing and descriptions of tiling on concrete floors etc shall
be deemed to include 1:3 plaster bedding

Tiling described as 'fixed with adhesive on power floated


concrete' shall be deemed to include for approved tiling key-
coat
Ceramic, porcelain, marble and granite tiles are to be fixed
and grouted with suitable adhesives and grouts as
recommended by the manufacturer of the tiles

WALL TILING

300 x 300mm Ceramic tiles fixed with adhesive to plaster


(plaster elsewhere) and flush pointed with tinted grout

1 On walls m² 23.00

2 On walls in isolated panels, splashbacks, etc m² 10.00


Annexure A
23
Bill of Quantities

Item Description Uom Qty Rate Amount

BILL NO.12 : TILING - TOTAL

BILL NO.13 : PLUMBING AND DRAINAGE

SUPPLEMENTARY PREAMBLES

Sealing of edges

Outer edges of sinks, basins, baths, urinals, etc are to be


sealed against adjacent surfaces with approved silicone

uPVC pipes and fittings

Sewer and drainage pipes and fittings shall be jointed and


sealed with butyl rubber rings Soil, waste and vent pipes and
fittings shall be solvent weld jointed or sealed with butyl
rubber rings

uPVC pressure pipes and fittings

Pipes of 50mm diameter and smaller shall be plain ended


with solvent welded uPVC loose sockets and fittings Pipes of
63mm diameter and greater shall have sockets and spigots
with push-in type integral rubber ring joints. Bends shall be
uPVC and all other fittings shall be cast iron, all with similar
push-in type joints

High density polyethylene (HDPe) pipes and fittings

Pipes shall be type IV and of the class specified with Plasson


or Alprene compression fittings

Copper pipes

Pipes shall be hard drawn and half-hard pipes of the class


described. Class 0 (thin walled hard drawn) pipes shall not
be bent. Class 1 (thin walled half-hard), Class 2 (half-hard)
and Class 3 (heavy walled half-hard) pipes shall only be bent
with benders with inner and outer formers. Fittings to copper
waste, vent and anti-syphon pipes, capillary solder fittings
and compression fittings shall be Cobra Watertech type, or
equivalent. Capillary solder fittings shall comply with ISO
2016

Copper pipes are to be installed in accordance with the latest


revision of the Code of Practice for Copper Plumbing
soldering
Reducing techniques.
fittings Flux, solder, etc to be strictly in
accordance with the manufacturer's requirements with
special attention to copper flux composition
Annexure A
24
Bill of Quantities

Item Description Uom Qty Rate Amount


Where fittings have reducing ends or branches they are
described as 'reducing' and only the largest end or branch
size is given. Should the contractor wish to use other fittings
and bushes or reducers he may do so on the understanding
that no claim in this regard will be entertained

Fixing of pipes

Unless specifically otherwise stated, descriptions of pipes


shall be deemed to include fixing to walls, etc, casting in,
building in or suspending not exceeding 1m below
suspension level

RAINWATER DISPOSAL

Watertite' or similar approved purpose-made aluminium


gutters:
1 Gutter 150 x 140mm wide fixed to fascia (facia elswhere) at
500mm centres. m 13.00

2 Extra for stopped end. No 4.00

3 Extra for outlet for 110mm diameter pipe. No 4.00

Aluminium downpipes.

4 110mm Round downpipe fixed to wall at 1000mm centres. m 6.00

5 Extra for standard 110mm shoe. No 4.00

SOIL DRAINAGE

Class 34 SABS 967:

6 110mm Pipes laid in and including trenches not exceeding


1m deep. m 146.00

Extra over uPVC pipes for fittings:

7 110mm Cleaning eye. No 4.00

8 110mm Access bend. No 3.00

9 110mm Access junction. No 2.00

Gulleys:

10 110mm Gulley not exceeding 500mm deep including bedding


in concrete, half brick wall surround and benching internally. No 2.00
Annexure A
25
Bill of Quantities

Item Description Uom Qty Rate Amount

Inspection chambers:

11 Excavate for and build manhole with one brick sides in extra
hard stock bricks in (1:3) cement mortar on 150mm concrete
Class 20 bottom projecting 150mm all round, rendered
internally in (1:3) cement plaster with brickwork cobbled to
suite cast iron manhole cover and frame (elsewhere
measured) the bottom benched up in fine concrete Class 20 No 2.00
finished smooth in (1:11) cement plaster (channels elsewhere
measured), including all necessary formwork, reinforcing etc.
Size internally 450 x 600mm and not exceeding 1 m deep
from invert, including all necessary formwork, reinforcing, etc

Gratings, covers, etc:

12 450 x 600mm x 68kg Type 9D cast iron single seal manhole


cover and frame. No 2.00

Sundries:

13 Excavate, break into and connect up to existing manhole,


including excavation, backfilling, ramming, etc. No 1.00

SANITARY FITTINGS

Smeg' or equivalent sinks:

14 1 160 x 500 x 195mm RHD Aurora double sink with two


basket strainer waste. No 1.00

Duravit' sanitaryware vitreous china WC suites or equivalent


and approved to manufacturer's specifications:

15 D-Code Independent floor mounted pan comprising D-Code


toilet seat & standard cover with 120mm 'Sigma' concealed
cistern including fitments and Capri polished chrome dual No 3.00
flush plate complete all to manufacturers specification.

Betta' sanitaryware vitreous china WC suites or equivalent


and approved to manufacturer's specifications:

16 Iqwa white close couple toilet suite complete to


No 1.00
manufacturer's specifications.

Verdi Sanitaryware' wash hand basins or equivalent:


Annexure A
26
Bill of Quantities

Item Description Uom Qty Rate Amount

17 530 x 410mm 'Metis' white wall hung basin with tap hole
complete to manufacturer's specifications. No 4.00

WASTE UNIONS ETC

Waste unions, etc:

18 Pop up basin waste for basin installations with overflows. No 4.00

Lola' or equal and approved:

19 Waste trap with 110x110mm square shower grating. No 1.00

TRAPS ETC

E Space trap:

20 Double bowl sink trap including extension piece fitted under No 1.00
sink.
Stylux' or equal and approved:

21 32 x 40mm Bottle trap. No 8.00

TAPS, VALVES, ETC

Tivoli' or equivalent:

22 Roma elite wall type sink mixer. No 1.00

23 Gadoni bath or shower mixer including concealed part No 1.00


complete.
Hansgrohe' or equivalent:

24 Decor 70 Single Lever Basin Mixer No 4.00

25 Crometta 85 green showerhead No 1.00

26 55mm Relexa 100 trio shower arm. No 1.00

SANITARY PLUMBING

uPVC soil and vent pipes

27 40mm Pipes chased into brickwork (Provisional) m 19.00

28 50mm Pipes chased into brickwork (Provisional) m 38.00

29 110mm Pipes chased into brickwork (Provisional). m 24.00

Extra over uPVC soil and vent pipes for fittings

30 50mm Bend (Provisional) No 24.00

31 110mm Bend (Provisional) No 12.00


Annexure A
27
Bill of Quantities

Item Description Uom Qty Rate Amount

32 50mm Junction (Provisional) No 13.00

33 110mm Junction. (Provisional) No 8.00

34 110mm Straight pan connector. (Provisional) No 4.00

35 110 x 50mm Reducing junction. (Provisional) No 5.00

Testing

36 Testing waste pipe system (Provisional) Item 1.00

WATER SUPPLIES

Class 2 copper pipes:

37 15mm Pipes chased into brick walls (Provisional) m 76.00

38 22mm Pipes chased into brick walls (Provisional) m 38.00

Extra over class 2 copper and polypropylene pipes for brass


compression fittings:

39 15mm Fittings (Provisional) No 96.00

40 22mm Fittings (Provisional) No 48.00

41 Allowance for connecting new water supply to existing


(Provisional) Item 1.00

BUDGETARY ALLOWANCES

The following net sums are for work to be executed by the


principal contractor and or specialists and will be measured
on completion and priced in terms of the contract as directed
by the project manager and deducted in whole or part if not
required

42 Provide the amount of R 20 000.00 (Twenty Thousand Rand


Only) for new rainwater tanks installed complete to be spent Item 1.00
in whole or part or omitted from the contract
Annexure A
28
Bill of Quantities

Item Description Uom Qty Rate Amount

BILL NO.13 : PLUMBING AND DRAINAGE - TOTAL

BILL NO.14 : PAINTWORK

SUPPLEMENTARY PREAMBLES

Extra over paintwork to all areas, for paintwork in colours


which have a value of 7 or less based on the Munsell system
m². Extra over paintwork to gates, grilles, burglar screens,
balustrades, etc, for paintwork in colours which have a value
of 7 or less based on the Munsell system (both sides
measured over the full flat area) m². Extra over paintwork to
rails, bars, pipes, etc not exceeding 300mm girth, for
paintwork in colours which have a value of 7 or less based on
the Munsell system m. Extra over paintwork to skirtings,
rails, etc not exceeding 300mm girth for paintwork in colours
which have a value of 7 or less based on the Munsell system
m. Note It has however become evident that application
problems exist with the said Munsell system and until such
time as the Standard System of Measuring Building Work is
adjusted to overcome these problems users should
determine from the relevant manufacturer which of their
colour groupings differ appreciably in price and adjust
descriptions accordingly.

PAINTWORK ETC TO NEW WORK

ON INTERNAL FLOATED PLASTER SURFACES

Prepare surfaces and remove all loose or flaking material,


ensure surface is dry and dust free and apply one coat
Plascon plaster primer, or equivalent, and two coats Plascon
Cashmere, or equivalent, for interior use on:

1 On walls. m² 853.00

2 On ceilings and beams. m² 18.00

ON EXTERNAL FLOATED PLASTER SURFACES

Prepare surfaces and remove all loose or flaking material,


ensure surface is dry and dust free and apply one coat
Plascon plaster primer, or equivalent, and two coats Plascon
Cashmere, or equivalent, for interior use on:

3 On walls. m² 457.00

ON INTERNAL GYPSUM PLASTER SURFACES


Annexure A
29
Bill of Quantities

Item Description Uom Qty Rate Amount


Prepare surfaces and remove all loose or flaking material,
ensure surface is dry and dust free and apply one coat
plaster primer and two coats Plascon Super Acrylic Polvin
Matt or equivalent and approved paint for interior use on:

4 On ceilings and cornices. m² 231.00

ON ROUGH CONCRETE SURFACES

One coat primer and two coats polyurethane paint for interior
use:
5 On floors. m² 84.00

ON FIBRE-CEMENT BOARD SURFACES

One coat plaster primer and two coats 'Plascon Polvin Super
Acrylic' paint, or equivalent, for exterior use:

6 On fascias, barge boards, etc. m² 6.00

ON METAL SURFACES

Prepare surfaces and remove all loose or flaking material,


ensure surface is dry and dust free and apply one coat
universal undercoat and two coats enamel or equal and
approved paint for interior use on:

7 On door frames. m² 23.00

ON WOOD SURFACES

Two coats oil wood primer

8 On backs of frames, linings, etc not exceeding 300mm wide m 338.00

Prepare surfaces and remove all loose or flaking material,


ensure surface is dry and dust free and apply one coat
universal undercoat and two coats enamel or equal and
approved paint for interior use on:

9 On doors. m² 71.00

10 On door frames. m² 1.00

Prepare surfaces and remove all loose or flaking material,


ensure surface is dry and dust free and apply UV-cured
acrylic varnish with ceramic beads or equal and approved
paint for interior use on:

11 On flooring. m² 41.00
Annexure A
30
Bill of Quantities

Item Description Uom Qty Rate Amount

BILL NO.14 : PAINTWORK - TOTAL

BILL NO.15 : EXTERNAL WORKS

EXTERNAL WORKS

Excavate in earth not exceeding 2m deep:

1 Trenches. m³ 18.00

Risk of collapse of excavations other than bulk:

2 Sides of trench and hole excavations not exceeding 1,5m m² 58.00


deep.
Extra over all excavation for loading, carting and dumping
surplus excavated material (no allowance made for increase
in bulk):
3 To make up levels where directed on site. m³ 10.00

Filling with material from the excavations compacted to a


density of at least 98% Mod. AASHTO maximum density:

4 Backfilling to trenches, holes, etc. m³ 9.00

Keep excavations free of water:

5 Keeping excavations free of all water other than


subterranean water. Item 1.00

15MPa/19mm Concrete:

6 Surface blinding under footings and bases. m³ 1.00

25MPa/19mm Reinforced concrete:

7 Strip footings (provisional). m³ 5.00

Reinforcement:

8 Bars of varying length and diameter. Tonnes 0.18

Brickwork of NFX bricks (14 MPa nominal compressive


strength) in Class I mortar:

9 One brick walls. m³ 26.00


Annexure A
31
Bill of Quantities

Item Description Uom Qty Rate Amount


10 280mm Hollow walls of two half brick skins including wire m³ 3.00
ties.
Brickwork reinforcement:

11 75mm Wide reinforcement built in horizontally. m 381.00

External compo plaster on brickwork:

12 On walls. m² 29.00

Apply one coat Plascon plaster primer and two coats Plascon
Wall & All or equivalent paint for exterior use on:
13 On walls. m² 29.00
BUDGETARY ALLOWANCES

The following net sums are for work to be executed by the


principal contractor and or specialists and will be measured
on completion and priced in terms of the contract as directed
by the project manager and deducted in whole or part if not
required

14 Provide the amount of R 50 000.00 (Fifty Thousand Rand


Only) for new ramps, stoep, balustrade and decking to be Item 1.00
spent in whole or part or omitted from the contract

15 Provide the amount of R 30 000.00 (Thirty Thousand Rand


Only) for new pergola & awnings to be spent in whole or part Item 1.00
or omitted from the contract
Annexure A
32
Bill of Quantities

Item Description Uom Qty Rate Amount

BILL NO.15 : EXTERNAL WORKS

BILL NO.16 : PROVISIONAL SUMS

PROVISIONAL SUMS

Electrical Installation:

1 Provide the sum of R665 000.00 ( Six Hundred and Sixty


Five Thousand Rands) for Electrical Installation complete. Item

2 Profit on above item. Item

3 Attendance on ditto. Item

Joinery Installation:

4 Provide the amount of R160 000.00 ( One Hundred and


Sixty Thousand Rands) for Joinery Installation complete. Item

5 Profit on above item. Item 1.00

6 Attendance on ditto. Item 1.00

PROVISIONAL AMOUNT

Builders Work:

7 Provide the amount of R5 000.00 (Five Thousand Rands) for


builders work in connection with electrical and plumbing Item
installations.
Annexure A
33
Bill of Quantities

Item Description Uom Qty Rate Amount

BILL NO.16 : PROVISIONAL SUMS - TOTAL

SECTION NO. 2 : GARAGE

BILL NO.1 : EARTHWORKS

SUPPLEMENTARY PREAMBLES

Provisional:

All work measured under this trade is provisional and subject


to re-measurement on site.

Nature of ground:

The nature of the ground is assumed to be loose sandy


material, therefore earth, but possibly interspersed with soft
or hard rock.

Carting away of excavated material:

Descriptions of carting away of excavated material shall be


deemed to include loading excavated material onto trucks
directly from the excavations or, alternatively, from stock piles
situated on the building site.

SITE CLEARANCE, ETC.

Site clearance, etc.:

1 Allow for clearing the area of the site to be built upon of all
grass, weeds, shrubs, trees with trunks not exceeding
200mm girth, debris, etc., including grubbing up all roots, m² 143.00
scuffling up as required and cart away all vegetation and
debris.

REMOVAL OF TREES ETC

Cutting down and removing, grubbing up roots and filling in


holes
2 Tree exceeding 200mm and not exceeding 500mm girth No 3.00

EXCAVATION OTHER THAN BULK

Excavation in earth not exceeding 2m deep:


Annexure A
34
Bill of Quantities

Item Description Uom Qty Rate Amount

3 Trenches. m³ 23.00

Extra over excavations other than bulk in earth for excavation


in:

4 Soft rock. m³ 2.00

5 Hard rock. m³ 1.00

Risk of collapse of excavations other than bulk:

6 Sides of trench and hole excavations not exceeding 1,5m


deep. m² 66.00

CARTING AWAY.

Extra over all excavations for loading, carting and dumping


surplus excavated material (no allowance made for increase
in bulk):

7 To make up levels where directed on site. m³ 13.00

EARTH FILLING, ETC.

Filling with material from the excavations compacted to 98%


Mod. AASHTO density:
8 Backfilling to trenches, holes, etc. m³ 10.00

Filling with approved material supplied and carted onto site


by the Contractor, compacted to a density of at least 95%
Mod. AASHTO maximum density:

9 Under floors, pavings, etc. m³ 6.00

Filling with course river sand compacted to 98% Mod.


AASHTO density:

10 Under floors, pavings, etc m³ 3.00

KEEPING EXCAVATIONS FREE OF WATER

Keeping excavations free of water:


11 Keep excavations free of all water other than subterranean Item 1.00
water.
Annexure A
35
Bill of Quantities

Item Description Uom Qty Rate Amount

BILL NO.1 : EARTHWORKS

BILL NO.2 : CONCRETE, FORMWORK AND


REINFORCEMENT

SUPPLEMENTARY PREAMBLES

Cost of tests:

The costs of making, storing and testing of concrete test


cubes as required under clause 7 'Tests' of SABS 1200 G
shall include the cost of providing cube moulds necessary for
the purpose, for testing costs and for submitting reports on
the tests to the Architect. The testing shall be undertaken by
an independent firm or institution nominated by the
Contractor to the approval of the Architect. (Test cubes are
measured separately).

Formwork:

Descriptions of formwork shall be deemed to include use and


waste only (except where described as left in or permanent),
for fitting together in the required forms, wedging, plumbing
and fixing to true angles and surfaces as necessary to
ensure easy release during stripping and for reconditioning
as necessary before re-use.

The vertical strutting shall be carried down to such


construction as is sufficiently strong to afford the required
support without damage and shall remain in position until the
newly constructed work is able to support itself.

Formwork to sides of bases, pile caps, ground beams, etc.,


will only be measured where it is prescribed by the Engineer
for design reasons. Formwork necessitated by irregularity or
collapse of excavated faces will not be measured and the
cost thereof shall be deemed to be included in the allowance
for taking the risk of collapse of the sides of the excavations,
provision for which is made in Earthworks.

UNREINFORCED CONCRETE

15MPa/19mm Concrete:

1 Filling to cavity of hollow walls (provisional). m³ 2.00

2 Surface blinding under footings and bases. m³ 1.00


Annexure A
36
Bill of Quantities

Item Description Uom Qty Rate Amount


REINFORCED CONCRETE CAST AGAINST EXCAVATED
SURFACES
25 MPa/19mm Concrete:

3 Strip footings (provisional). m³ 6.00

30MPa/19mm concrete
4 Surface beds on waterproofing m³ 6.00

TEST BLOCKS

Test blocks:

CONCRETE SUNDRIES

Finishing top surfaces of concrete smooth with a power float

6 Surface beds, slabs, etc m² 62.00

REINFORCEMENT (PROVISIONAL)

Mild steel reinforcement to structural concrete work:

7 Bars of varying length and diameter. Tonnes 0.09

High tensile steel reinforcement to structural concrete work:

8 Bars of varying length and diameter. Tonnes 0.14

Fabric reinforcement

9 Type 193 fabric reinforcement in concrete surface beds etc m² 62.00


Annexure A
37
Bill of Quantities

Item Description Uom Qty Rate Amount

BILL NO.2 : CONCRETE, FORMWORK AND


REINFORCEMENT
BILL NO.3 : MASONRY
BRICKWORK

Sizes in descriptions:

Where sizes in descriptions are given in brick units, 'one


brick' shall represent the length and 'half brick' the width of a
brick.
Hollow walls etc:
Descriptions of hollow walls shall be deemed to include
leaving every fifth perpend of the bottom course of the
external skin open as a weep hole.

BRICKWORK IN FOUNDATIONS

Brickwork of NFX bricks (14 MPa nominal compressive


strength) in Class I mortar:

1 280mm Hollow walls of two half brick skins including wire m² 33.00
ties.
BRICKWORK IN SUPERSTRUCTURE

Brickwork of NFX bricks (14 MPa nominal compressive


strength) in class II mortar

2 280mm Hollow walls of two half brick skins including wire m² 113.00
ties.
BRICKWORK SUNDRIES

Brickwork sundries:

3 Splayed mortar fillet one course high in 50mm cavity. m 39.00

4 Closing 50mm cavity of hollow wall horizontally with one


course of brickwork. m 34.00

5 Closing 50mm cavity of hollow wall vertically with brickwork


half brick wide. m 14.00

Brickwork reinforcement:

6 75mm Wide reinforcement built in horizontally. m 1 448

Prestressed fabricated lintels:


7 110 x 75mm Lintels in lengths not exceeding 3m. m 8.00

8 150 x 75mm Lintels in lengths not exceeding 3m. m 8.00

BRICK PAVING
Annexure A
38
Bill of Quantities

Item Description Uom Qty Rate Amount


Paving of 200 x 200 x 70mm thick "C.E.L" paving blocks with
fine exposed aggregate finish in charcoal colour with butt
joints on sand bed (sand bed elsewhere measured) with dry
filler sand swept into joints:
9 Paving to falls in stretcher or running bond. m² 10.00

10 Extra over for 400mm Channel to edge of paving comprising


m 12.00
one course tilted up with one flat course, bedded on
concrete.

BILL NO.3 : MASONRY - TOTAL

BILL NO.4 : WATERPROOFING

SUPPLEMENTARY PREAMBLES

Waterproofing:

Waterproofing of roofs, basements, etc., shall be laid under a


ten year guarantee. Waterproofing to roofs shall be laid to
even falls to outlets etc with necessary ridges, hips and
valleys. Descriptions of sheet or membrane waterproofing
shall be deemed to include additional labour to turn-ups and
turn-downs.

DAMPPROOFING OF WALLS AND FLOORS

One layer of Brikgrip 375 type B laminated damp proof


course:
1 In walls. m² 16.00

2 Wrapped around ends of rafters built into walls (Provisional). m² 4.00

One layer of USB Green 250 type C laminated sheeting


sealed at laps with pressure sensitive tape:

3 Under surface beds. m² 62.00

JOINT SEALANTS, ETC.

Alcolin dual-component polisulphide sealing compound


including backing cord, bond breaker, primer, etc:
4 6 x 40mm In saw-cut joints in floors (Provisional). m 54.00

5 10 x 15mm In expansion joints in floors including raking out


expansion joint filler as necessary. m 32.00
Annexure A
39
Bill of Quantities

Item Description Uom Qty Rate Amount

BILL NO.4 : WATERPROOFING

BILL NO.5 : ROOF COVERINGS

CORRUGATED METAL SHEETING AND ACCESSORIES

0.47mm/0.53mm Zincalume profile in Clean COLORBOND™


steel, metallic coating AZ150 minimum (150g/m2 ) coating
mass, Grade G550, super polyester paint system (colour
grey), 25um on topside and 10um on reverse side, or
equivalent.

1 Roof covering with pitch not exceeding 25 degrees. m² 64.00

2 Headwall Flash 308mm girth 1 times bent including serrated


closers and poly-closers. m 9.00

3 Sidewall Flash 308mm girth 1 times bent. m 14.00

4 Counter Flash 185mm girth 2 times bent. m 23.00

5 Narrow and broad flute closers to suit curragated profile. m 9.00

ROOF INSULATION

4mm Alucushion® double - sided aluminium foil insulation, or


equivalent, in strict accordance with the manufacturers
specifications:

6 Laid taut over purlins and fixed concurrent with roof covering;
overlapped longitudinally by 100mm; on and including m² 64.00
galvanised straining wires.
Annexure A
40
Bill of Quantities

Item Description Uom Qty Rate Amount

BILL NO.5 : ROOF COVERINGS

BILL NO.6 : CARPENTRY AND JOINERY

SUPPLEMENTARY PREAMBLES

Joinery:

Descriptions of frames shall be deemed to include frames,


transoms, mullions, rails, etc.

Descriptions of hardwood joinery shall be deemed to include


pelleting of bolt holes.

Fixing:

Items described as nailed shall be deemed to be fixed with


hardened steel nails or shot pins to brickwork or concrete.

EAVES, VERGES, ETC

Everite Nutec' medium density sheets, or equivalent:

1 12 x 225mm Plain fascia boards including 'Chromaprep' H-


profile jointing strips and corner jointers, or equivalent. m 9.00

SKIRTINGS, CORNICES, ETC.

Wrought hardwood:

2 22 x 140mm Skirtings plugged (code WSK3). m 32.00

ROOFS ETC

Sawn softwood

3 50 x 150mm SA pine rafters in lengths exceeding 6,6m m 72.00


4 50 x 76mm SA pine purlins. m 85.00

ROOF SUNDRIES

Sundries:
Annexure A
41
Bill of Quantities

Item Description Uom Qty Rate Amount


5 U-shaped galvanised mild steel bracket UH50/80 fixed to
timber rafters. No 11.00

6 30 x 1,2mm Galvanised hoop iron roof tie 600mm long with


one end fixed to wood and other end built into brickwork. No 11.00

BILL NO.6 : CARPENTRY AND JOINERY

BILL NO.7 : CEILINGS PARTITIONS AND ACCESS


FLOORING

SUPPLEMENTARY PREAMBLES

Fixing

Items described as 'nailed' shall be deemed to be fixed with


hardened steel nails or pins, or to be shot-pinned, to
brickwork or concrete

Items described as 'plugged' shall be deemed to include


screwing to fibre, plastic or metal plugs at not exceeding
500mm centres, and where described as 'bolted', the bolts
have been given elsewhere

Ceilings

Unless otherwise described ceilings shall be deemed to be


horizontal

NAILED-UP CEILINGS

9,5mm Gypsum plasterboard with taped joints and the whole


finished with gypsum plaster trowelled to a smooth polished
surface to the thickness recommended by the manufacturer

1 Ceilings including 38 x 38mm sawn softwood brandering at


460mm centres. m² 62.00

Prepainted metal cornices to ceilings:

2 25mm Shadowline cornices, plugged m 32.00


Annexure A
42
Bill of Quantities

Item Description Uom Qty Rate Amount

BILL NO.7 : CEILINGS PARTITIONS AND ACCESS


FLOORING

BILL NO.8 : METALWORK

SUNDRY GALVANIZED STEELWORK

Sundries:

1 30 x 6mm Flat section thresholds with 5mm diameter bent


lugs each 75mm girth welded on at 300mm centres, including m 5.00
embedding in concrete.

Bolts:

2 12mm Diameter bolts. No 44.00

ALUMINIUM WINDOWS, DOORS, ETC.

SUPPLEMENTARY PREAMBLES

Aluminium doors, windows, etc


Descriptions include for all aluminium work, fixing in position,
fixings, glazing and sealing both sides complete.

Doors and windows shall comply with AAAMSA design


criteria. Glazing shall comply with SAGGA regulations. Glass
shall be laminated performance glass as shown on the
window schedules/drawings appended to these bills of
quantities (as described in the headings to window
descriptions).
Glass thickness shall comply with SAGGA regulations
irrespective of thicknesses shown on the
schedules/drawings. Doors and windows shall be supplied
with protective tape and plastic and shall be removed only
once surrounding trades have been completed. For purpose
made windows and doors, refer to drawings annexed to
these bills of quantities.

The following certificates shall be provided prior to


commencement of site work:

1 A copy of the relevant AAAMSA Performance Test


Certificate from the manufacturer/contractor supplying the
architectural aluminium product.
Annexure A
43
Bill of Quantities

Item Description Uom Qty Rate Amount

2 A Certificate of Conformance confirming that anodising or


powder coating has been processed in accordance with
SANS 999 and SANS 1796 respectively.

3 A powder guarantee of not less than 15 years issued by the


powder manufacturer. The specific conditions contained in
this guarantee shall form part of the powder coating process.

4 A Certificate of Conformance confirming that glazing has


been installed in accordance with SANS 0137, ensuring that
safety glazing materials have been installed in the mandatory
areas and that each individual pane of safety glazing
materials has been permanently marked.

5 A warranty from the manufacturer of the laminated safety


glass and/or hermetically sealed glazing units guaranteeing
the products against delamination and colour degredation for
a period of not less than five years.

Tenderers are referred to attached Door and window


schedules for full specifications and details of following work.
Prices are to include for all aluminium, powder coating,
fabrication, ironmongery, fixing in position, glazing and
sealing.
All aluminium door and window frame sizes and sections are
to be approved by the architect prior to commmencent of
sub-contract work. Epoxy powder coated framed will be to
the colour specified by the architect from the manufacturer's
standard colour chart.

Unless otherwise stated on the annexed drawings, all


aluminium frames are to be a minimum of 34mm thick and
components are to have the following minimum widths:

Casements minimum 30.5mm

Sliders minimum 70mm

Doors minimum 76mm

Refer to attached Window and Shopfront schedules for


drawings of all aluminium work.

Powder coated aluminium windows glazed with 6,38mm


safety glass complete with subframes, ironmongery, sealing,
etc and fixing to brickwork or concrete:
3 Window 600 x 900mm high overall with fixed and opening
section (Window Type I dwg no. W-6208). No 2.00

GARAGE DOORS

Overhead garage doors fixed to brickwork or concrete


Annexure A
44
Bill of Quantities

Item Description Uom Qty Rate Amount


4 Overhead corrugated iron garage door for 2 600 x 2 500mm
high opening, including slider mechanism, ironmongery, etc.
installed complete as per manufactureres specification (type No 2.00
K dwg no. W-6110).

BILL NO.8 : METALWORK - TOTAL

BILL NO.9 : PLASTERING

INTERNAL PLASTER

Compo plaster with gypsum skim on brickwork:

1 On walls. m² 85.00

2 On narrow widths. m² 3.00

EXTERNAL PLASTER

Compo plaster on brickwork:

3 On walls. m² 125.00

4 On narrow widths. m² 3.00


Annexure A
45
Bill of Quantities

Item Description Uom Qty Rate Amount

BILL NO.9 : PLASTERING - TOTAL

BILL NO.10 : PLUMBING AND DRAINAGE

RAINWATER DISPOSAL

Watertite' or similar approved purpose-made aluminium


gutters:
1 Gutter 150 x 140mm wide fixed to fascia (facia elswhere) at
500mm centres. m 9.00

2 Extra for stopped end. No 2.00

3 Extra for outlet for 110mm diameter pipe. No 2.00

Aluminium downpipes.

4 110mm Round downpipe fixed to wall at 1000mm centres. m 5.00

5 Extra for standard 110mm shoe. No 2.00


Annexure A
46
Bill of Quantities

Item Description Uom Qty Rate Amount

BILL NO.10 : PLUMBING AND DRAINAGE - TOTAL

BILL NO.11 : PAINTWORK

ON INTERNAL FLOATED PLASTER SURFACES


Prepare surfaces and remove all loose or flaking material,
ensure surface is dry and dust free and apply one coat
Plascon plaster primer, or equivalent, and two coats Plascon
Cashmere, or equivalent, for interior use on:

1 On walls. m² 85.00

ON EXTERNAL FLOATED PLASTER SURFACES


Prepare surfaces and remove all loose or flaking material,
ensure surface is dry and dust free and apply one coat
Plascon plaster primer, or equivalent, and two coats Plascon
Cashmere, or equivalent, for interior use on:

2 On walls. m² 127.00

ON INTERNAL GYPSUM PLASTER SURFACES

Prepare surfaces and remove all loose or flaking material,


ensure surface is dry and dust free and apply one coat
plaster primer and two coats Plascon Super Acrylic Polvin
Matt or equivalent and approved paint for interior use on:

3 On ceilings and cornices. m² 62.00 38.57

ON FIBRE-CEMENT BOARD SURFACES

One coat plaster primer and two coats 'Plascon Polvin Super
Acrylic' paint, or equivalent, for exterior use:

4 On fascias, barge boards, etc. m² 4.00

ON WOOD SURFACES

Two coats oil wood primer

5 On backs of frames, linings, etc not exceeding 300mm wide m 32.00 24.36
Annexure A
47
Bill of Quantities

Item Description Uom Qty Rate Amount

BILL NO.12 : PAINTWORK - TOTAL

ELECTRICAL PORTION
MAIN BUILDING - SMALL POWER & LIGHTING
REQUIREMENTS

DISTRIBUTION BOARDS & EQUIPMENT


Manufacture, supply, install, test and commission, new
distribution boards to specification
1 Main Distribution Board - MDB01 Sum 1
2 Main Distribution Board - MDB02 Sum 1

Supply, install, and interconnect with appropriately rated


busbar, the following Din rail mounted equipment, to
specification, within distribution board

3 25A - 3 pole, 6kA CB No 1 Rate Only


4 25A - 2 pole, 6kA CB No 1 Rate Only
5 10A - 2 pole, 6kA CB No 1 Rate Only
6 20A - 1 pole, 6kA CB No 1 Rate Only
7 16A - 1 pole, 6kA CB No 1 Rate Only
8 10A - 1 pole, 6kA CB No 1 Rate Only
9 5A - 1 pole, 6kA CB No 1 Rate Only
10 63A D.P 6 kA 30mA Earth Leakage Circuit Breaker No 1 Rate Only
Supply, install, and interconnect equipment, to specification,
within existing electrical distribution panel
11 100A - 3 pole, 10kA CB No 1

CABLES AND TERMINATIONS


Deliver, offload and install within trenches, sleeves, cable
rack or ducts the following:
TYPE P1 BLACK PVC/SWA/PVC/Cu 600/1000V Multicore
cables.
1 70mm² x 4 core m 1 Rate Only
2 50mm² x 4 core m 1 Rate Only
3 35mm² x 4 core m 145
4 16mm² x 4 core m 15
5 6mm² x 4 core m 1 Rate Only
6 2.5mm² x 4 core m 1 Rate Only
Annexure A
48
Bill of Quantities

Item Description Uom Qty Rate Amount


7 2.5mm² x 3 core m 1 Rate Only
8 1.5mm² x 4 core m 1 Rate Only
9 1.5mm² x 3 core m 1 Rate Only

Gland, terminate and label the following TYPE P 1 cables


within a NON HAZARDOUS AREA (i.e. CW gland)
10 70mm² x 4 core No 1 Rate Only
11 50mm² x 4 core No 1 Rate Only
12 35mm² x 4 core No 2
13 16mm² x 4 core No 2
14 6mm² x 4 core No 1 Rate Only
15 2.5mm² x 4 core No 1 Rate Only
16 2.5mm² x 3 core No 1 Rate Only
17 1.5mm² x 4 core No 1 Rate Only
18 1.5mm² x 3 core No 1 Rate Only

Supply and jointing of cables with the appropriate size


jointing kit in the event where cables are to short.
Cable measured elsewhere
19 Scotchcast Splicing Kit - Size 2 No 1 Rate Only
20 Scotchcast Splicing Kit - Size 3 No 1 Rate Only
21 Scotchcast Splicing Kit - Size 4 No 6 Rate Only
22 Scotchcast Splicing Kit - Size 5 No 1 Rate Only
23 Scotchcast Splicing Kit - Size 6 No 1 Rate Only

Making safe, disconnection, pulling back, re-routing


underground cable for jointing of the following TYPE P1
PVC/SWA/PVC cables from the existing "KIOSK" crossing
new building
Note: Cable and trenching measured elsewhere

24 70mm² x 4 core m 1 Rate Only


25 50mm² x 4 core m 1 Rate Only
26 35mm² x 4 core m 80 Rate Only
27 25mm² x 4 core m 1 Rate Only

Deliver, offload and install within sleeves, cable rack or ducts


Multimode fibre optic cable
28 12-core m 35

29 Cutting and pulling back of existing fibre optic cable and re- m 32
routing thereof through new cable sleeves (measured
elsewhere)

Splicing of multimode fibre optic cable, inclusive of testing


30 12-core No 2

CARRIED FORWARD
b/f
Annexure A
49
Bill of Quantities

Item Description Uom Qty Rate Amount


EARTHING & BONDING

Supply, deliver, offload and install the following Copper earth


conductors
1 25 mm²-Insulated m 25
2 16 mm²-Insulated m 120
3 10 mm²-Insulated m 20
4 6 mm²-Insulated m 15
5 4 mm²-Insulated m 1 Rate Only
6 2.5 mm²-Insulated m 100

Termination of earth conductors with a ring lug and stainless


steel set screw, nut and washers.
7 25 mm²-Insulated No 4
8 16 mm²-Insulated No 6
9 10 mm²-Insulated No 4
10 6 mm²-Insulated No 4
11 4 mm²-Insulated No 1 Rate Only
12 2.5 mm²-Insulated No 20

13 Supply and install Potential Equalising Earth Bars, 300mm x No 2


30mm x 6mm, c/w insulated mounting bolts and a series of
10mm dia holes with set screws, nuts and washers. Mounted
in ceiling of building

14 Supply and install 16mm diam., Cu, 1500mm long earth No 8


electrodes (c/w provision for additional coupling) and the
clamp for the termination of the earth conductor
PROVISIONAL

15 Final Bonding integrity Tests Sum 1

CIVIL WORKS
Excavate in soft rock for trenches, backfill and compact,
including removal of surplus/unsuitable materials to spoil off
site for trenches 0.6m wide and for depth:
1 Up to 0.6m deep m 218
2 Extra over item B.4.1.1 for excavation in soft rock cu.m 15.696
3 Extra over item B.4.1.1 for excavation in hard rock material cu.m 3.924
4 Extra over item B.4.1.1 for excavation through paved m 5
roadway and reinstating afterwards

5 Extra over item B.4.1.1 for imported backfill materials cu.m 26.16

Supply, install and bed 50mm PAC KABLE FLEX cable sleeve in
trench complete with danger tape(trenching measured elsewhere)
6 Straight Lengths m 60
7 Long Radius Bends No 10

8 Supply and install Non metallic draw wires in all cable sleeves m 60

9 Supply and install concrete, conical cable route markers c/w No 12


inscribed stainless steel route marker plate
Annexure A
50
Bill of Quantities

Item Description Uom Qty Rate Amount


10 Draw pit/Manhole: Supply material and construct the following cable No 5
sleeve manholes, comprising:
100mm concrete base c/w damp course
110mm brick walls 700x700x700mm internal dims
Damp course on exterior of walls
Plaster internally
Fit and plaster manhole frame and cover - 450x600
Type 9D cast iron single seal cover and frame

11 Making of hole 150mm x 150mm through 270mm brick wall No 2


for the installation of 2off 110mm cable sleeve complete with
brick work, cement plastering and paint as required. Inclusive
of Henley compound sealant after cable installation

12 110mm core drill hole through reinforced concrete wall or No 8


floor for the installation of 110mm cable sleeve complete with
brick work, cement plastering and paint as required. Inclusive
of Henley compound sealant after cable installation

CARRIED FORWARD
b/f
Annexure A
51
Bill of Quantities

Item Description Uom Qty Rate Amount


SWITCHES & SWITCHED SOCKET OUTLETS
Supply and Installation to specification, with the cost including
the fitting of the unit, wiring to the appropriate Distribution
Board, final connections, tagging and testing.

Surface mounted - Inclusive of surface mounted conduit or


ducting wire ways
Type: Crabtree Classic or equal and approved
1 1 Lever 1 Way Switch Point 1 Rate Only
2 2 Lever 1 Way Switch Point 1 Rate Only
3 1 Lever 2 Way Switch Point 1 Rate Only
4 HWC Isolator Point 1 Rate Only
5 30 amp Double Pole HWC Isolator Point 1
6 16 amp Single Switched Socket Outlet Point 1 Rate Only
7 16 amp Single Switched Socket Outlet with shaved earth pin Point 1 Rate Only
8 16 amp Double Switched Socket Outlet Point 1 Rate Only
9 16 amp Double Switched Socket Outlet with shaved earth pin Point 1 Rate Only
10 16 amp Single Switched Socket Outlet within Weatherproof Point 1 Rate Only
enclosure
11 Type: GW 66 420 Surface Mount: 32A 3Ph+N+E Switched No 2
Socket Outlet
12 Type: GW 60 020 Straight Plug: 32A 3Ph+N+E No 2

Watertight Switches & Socket Outlets - Supply and


Installation to specification, with the cost including the fitting
of the unit, wiring, final connections and testing.
13 1 Lever 1 way in York box No 1 Rate Only
14 16 amp Single Switched Socket Outlet within Weatherproof No 3
enclosure
15 30 amp Double Pole Isolator within Weatherproof enclosure No 1

16 Flush mounted - Including wall boxes and wire ways


Type: Crabtree Diamond Series or equal and approved
17 2x4 Blanking plate No 10
18 4x4 Blanking plate No 10
19 1 Lever 1 Way Switch Point 12
20 1 Lever 2 Way Switch Point 6
21 2 Lever 1 Way + 1 Way Switch Point 3
22 2 Lever 1 Way + 2 Way Switch Point 1 Rate Only

23 3 Lever 1 Way + 1 Way + 1 Way Switch Point 1 Rate Only

24 3 Lever 1 Way + 1 Way + 2 Way Switch Point 1 Rate Only

25 4 Lever 1 Way + 1 Way + 1 Way + 1 Way Switch Point 1 Rate Only

26 2 Lever 1 Bell press + 1 Bell press Point 1


27 16 amp Single Switched Socket Outlet Point 1 Rate Only
28 16 amp Single New SA (164-2) Switched Socket Outlet Point 7
29 16 amp Double Switched Socket Outlet Point 12
30 30 amp Double Pole Stove Isolator Point 1
31 30 amp Double Pole HWC Isolator Point 1
Annexure A
52
Bill of Quantities

Item Description Uom Qty Rate Amount


32 Units 2
Floor box with lid complete with the following equipment
4 x socket outlets
4 x network points
2 x HDMI points
2 x Audio points
33 Data Points / LAN point only, no cabling Point 5
CARRIED FORWARD
b/f
Annexure A
53
Bill of Quantities

Item Description Uom Qty Rate Amount


POWER SKIRTING & ACCESSORIES
Supply and Install Power skirting. TYPE: Cabstrut
Execuduct MkII, White, 2-Compartment,165 x 55, installed
with silicon used to fill gaps between wall and skirting and
wire ways to distribution board, network and telephone panel
1 Straight lengths, complete with cover m 115
2 Joining Cover Clip No 35
3 End Caps No 58
4 Corner - Internal or External No 7
5 Flat Elbow No 1 Rate Only
6 Flat Tee No 1 Rate Only

Supply and Installation to specification, the following Power


Skirting accessories complete with cradle, cover, etc. including
the fitting of the unit, wiring, final connections, tagging and
testing.
Type: Crabtree Diamond Series
7 16A 3-pin normal switched socket outlet No 70
8 16A 3-pin dedicated switched socket outlet No 1 Rate Only
9 16A 2p+E socket outlet (new South African type) No 70
10 Data Points / LAN point only, no cabling No 60
11 Telephone connection point only no cabling No 1 Rate Only

LIGHTING & ACCESSORIES.


Supply and Installation to specification, including the fitting of
the unit, wiring, final connections, tagging and testing.
1 Internal ceiling recessed mounted LED Down lighter Point 66
Type L1: Venture Disk 24W SPL063
2 Internal ceiling recessed mounted LED Down lighter Point 10
Dimmable
Type L1.1: Venture Disk 24W SPL063 Dimmable
3 Internal ceiling surface mounted LED Tube fitting Point 5
Type L2: Venture Easy Fix Batten 36W VE112DB
4 Internal ceiling surface mounted LED Panel fitting Point 2
Type L3: Venture Vluma LED Panel 1200x300 40W
PNL009B surface mount
5 Internal ceiling surface mounted LED Panel fitting dimmable Point 3
Type L3.1: Venture Vluma LED Panel 1200x300 40W
PNL009B Dimmable surface mount
6 External wall mounted LED Bulkhead Fitting Point 10
Type L4 : Beka Series 42 LED Bulkhead 11W opaque
Note: Inclusive of mounting hangers from garage roof
structure

7 External wall mounted LED Footlight Fitting Point 5


Type L5 : Lascon TORINO 1 2W LED
8 Internal surface mounted emergency EXIT light Point 5
Type L6 : Beka LISU LED EXIT
9 Photo Electric Switch - mount outside in suitable position Point 2

CARRIED FORWARD
b/f
Annexure A
54
Bill of Quantities

Item Description Uom Qty Rate Amount


AUDIO, VISUAL & SECURITY ACCESSORIES
Supply and installation to specification, for the following
services flush mount wall boxes and wire ways to central
distribution point as required.
Note: Equipment and wiring to be done by others.

1 Security Sensor point Point 19


2 Security Keypad point Point 2
3 Security Panic point Point 1
4 Security Distribution point Point 1
5 HDMI outlet point Point 1
6 Audio point Point 1

PROVISIONAL SUM
Provision for additional work as may be required PC Sum 30000 30000

CARRIED FORWARD
b/f
Annexure A
55
Bill of Quantities

Item Description Uom Qty Rate Amount


GARAGE - SMALL POWER & LIGHTING REQUIREMENTS

DISTRIBUTION BOARDS & EQUIPMENT


Manufacture, supply, install, test and commission, new
distribution boards to specification
1 Garage Distribution Board - GARAGE-DB Sum 1
Supply, install, and interconnect with appropriately rated
busbar, the following Din rail mounted equipment, to
specification, within a distribution board
2 25A - 2 pole, 6kA CB No 1 Rate Only
3 20A - 1 pole, 6kA CB No 1 Rate Only
4 16A - 1 pole, 6kA CB No 1 Rate Only
5 10A - 1 pole, 6kA CB No 1 Rate Only
6 5A - 1 pole, 6kA CB No 1 Rate Only
Supply, install, and interconnect equipment, to specification,
within an existing electrical distribution board
7 30A - 2 pole, 6kA CB No 1
CABLES AND TERMINATIONS
Deliver, offload and install within trenches, sleeves, cable
rack or ducts the following:
TYPE P1 BLACK PVC/SWA/PVC/Cu 600/1000V Multicore
cables.

8 25mm² x 3 core m 65
9 16mm² x 4 core m 1 Rate Only

Gland, terminate and label the following TYPE P 1 cables


within a NON HAZARDOUS AREA (i.e. CW gland)
10 25mm² x 3 core No 2
11 16mm² x 4 core No 1 Rate Only

EARTHING & BONDING


Supply, deliver, offload and install the following Copper earth
conductors
12 16 mm²-Insulated m 10
13 10 mm²-Insulated m 10
14 2.5 mm²-Insulated m 30
15 Termination of earth conductors with a ring lug and stainless
steel set screw, nut and washers.
16 16 mm²-Insulated No 2
17 10 mm²-Insulated No 2
18 2.5 mm²-Insulated No 6

19 Supply and install Potential Equalising Earth Bars, 300mm x No 2


30mm x 6mm, c/w insulated mounting bolts and a series of
10mm dia holes with set screws, nuts and washers. Mounted
in ceiling of building

20 Supply and install 16mm diam., Cu, 1500mm long earth No 2


electrodes (c/w provision for additional coupling) and the
clamp for the termination of the earth conductor
PROVISIONAL

21 Final Bonding integrity Tests Sum 1

CARRIED FORWARD
Annexure A
56
Bill of Quantities

Item Description Uom Qty Rate Amount


b/f
Annexure A
57
Bill of Quantities

Item Description Uom Qty Rate Amount


B.13 CIVIL WORKS
B.13.1 Excavate in soft rock for trenches, backfill and compact,
including removal of surplus/unsuitable materials to spoil off
site for trenches 0.6m wide and for depth:
1 Up to 0.6m deep m 55
2 Extra over item B.13.1.1 for excavation in soft rock cu.m 3.96
3 Extra over item B.13.1.1 for excavation in hard rock material cu.m 0.99
PROVISIONAL
4 Extra over item B.13.1.1 for imported backfill materials cu.m 6.6

5 Supply, install and bed 50mm PAC KABLE FLEX cable sleeve in
trench complete with danger tape(trenching measured elsewhere)
6 Straight Lengths m 5
7 Long Radius Bends No 2

8 Supply and install Non metallic draw wires in all cable sleeves m 5

9 Supply and install concrete, conical cable route markers c/w No 5


inscribed stainless steel route marker plate

CARRIED FORWARD
b/f
Annexure A
58
Bill of Quantities

Item Description Uom Qty Rate Amount


B.14 SWITCHES & SWITCHED SOCKET OUTLETS
Supply and Installation to specification, with the cost including
the fitting of the unit, wiring to the appropriate Distribution
Board, final connections, tagging and testing.

B.14.1 Surface mounted - Inclusive of surface mounted conduit or


ducting wire ways
Type: Crabtree Classic or equal and approved
1 16 amp Single Switched Socket Outlet Point 1 Rate Only

2 Flush mounted - Including wall boxes and wire ways


Type: Crabtree Diamond Series or equal and approved
3 1 Lever 1 Way Switch Point 1
4 16 amp Single Switched Socket Outlet Point 8
5 16 amp Single New SA (164-2) Switched Socket Outlet Point 4
6 16 amp Double Switched Socket Outlet Point 1 Rate Only
7 16 amp Single Switched Socket Outlet within Weatherproof Point 1
enclosure

CARRIED FORWARD 30000


b/f 30000
Annexure A
59
Bill of Quantities

Item Description Uom Qty Rate Amount


B.15 LIGHTING & ACCESSORIES.
Supply and Installation to specification, including the fitting of
the unit, wiring, final connections, tagging and testing.
1 Internal ceiling surface mounted LED Tube fitting Point 4
Type L2: Venture Easy Fix Battaen 36W VE112DB
2 External wall mounted LED Bulkhead Fitting Point 1
Type L4 : Beka Series 42 LED Bulkhead 11W opaque
Note: Inclusive of mounting hangers from garage roof
structure

3 Photo Electric Switch - mount outside in suitable position Point 1

GARAGE ACCESSORIES
Supply and installation of the following, inclusive of mounting
hardware.

4 Sectional garage door opener (door height 2500mm) No 2


5 Additional 2-button remotes, inclusive of programming to No 6
door openers

PROVISIONAL SUM
1 Provision for additional work as may be required PC Sum 5000 5000
CARRIED FORWARD
b/f
Annexure A
60
Bill of Quantities

Item Description Uom Qty Rate Amount


GENERAL ELECTRICAL ACCESSORIES.
The following rates will be used for any variances to the scope
or the Contract. The rates must make adequate provision for
the Supply and Installation to specification, including the
material required for the fitting THEREOF.

EGA Duct
1 100mm x 40mm m 1 Rate Only
2 100mm x 40mm End Cap No 1 Rate Only
3 100mm x 40mm Elbow No 1 Rate Only
4 16mm x 16mm m 1 Rate Only
5 16mm x 16mm End Cap No 1 Rate Only
6 16mm x 16mm Elbow No 1 Rate Only
7 16mm x 16mm Coupling No 1 Rate Only
8 16mm x 16mm Tee No 1 Rate Only
9 40mm x 40mm m 1 Rate Only
10 40mm x 40mm End Cap No 1 Rate Only
11 40mm x 40mm Elbow No 1 Rate Only

PVC Wire
12 1.5mm² x 1 core m 1 Rate Only
13 2.5mm² x 1 core m 1 Rate Only
14 4mm² x 1 core m 1 Rate Only
15 6mm² x 1 core m 1 Rate Only

Cable
16 1.0mm² x Twin and Earth m 1 Rate Only
17 1.5mm² x Twin and Earth m 1 Rate Only
18 2.5mm² x Twin and Earth m 1 Rate Only
19 1.5mm² x 2 core + Earth Surfix m 1 Rate Only
20 2.5mm² x 2 core + Earth Surfix m 1 Rate Only
21 1.5mm² x 3 core SWA cable m 30 Rate Only
22 2.5mm² x 3 core SWA cable m 30 Rate Only

Gland, terminate and label the following cables


23 1.0mm² x Twin and Earth No 1 Rate Only
24 1.5mm² x Twin and Earth No 1 Rate Only
25 2.5mm² x Twin and Earth No 1 Rate Only
26 1.5mm² x 2 core + Earth Surfix No 1 Rate Only
27 2.5mm² x 2 core + Earth Surfix No 1 Rate Only
28 1.5mm² x 3 core SWA cable No 10 Rate Only
29 2.5mm² x 3 core SWA cable No 10 Rate Only

CARRIED FORWARD 35000


b/f 35000
Annexure A
61
Bill of Quantities

Item Description Uom Qty Rate Amount


PVC Conduit mounted on surface
30 20mm m 1 Rate Only
31 25mm m 1 Rate Only
32 32mm m 1 Rate Only

Galvanised Bosal Conduit mounted on surface


33 20mm m 1 Rate Only
34 25mm m 1 Rate Only
35 32mm m 1 Rate Only

PVC Conduit terminations


36 20mm No 1 Rate Only
37 25mm No 1 Rate Only
38 32mm No 1 Rate Only

PVC Boxes
39 20mm 4 way shallow No 1 Rate Only
40 25mm 4 way shallow No 1 Rate Only

Galvanised Boxes
41 20mm 4 way shallow No 1 Rate Only
42 25mm 4 way shallow No 1 Rate Only

Recessed Wall Boxes


43 100 X 50 Galv wall box No 1 Rate Only
44 100 X 100 Galv wall box No 1 Rate Only
45 100 X 50 Galv wonder box No 1 Rate Only
46 100 X 100 Galv wonder box No 1 Rate Only

Plug Tops
47 16 amp Normal No 1 Rate Only
48 16 amp Dedicated No 1 Rate Only

PROVISIONAL SUM
49 Provision for additional network equipment as may be PC Sum 15000 15000
required
Description Cost
SECTION NO. 1 : OFFICES
BILL NO.1 : EARTHWORKS
BILL NO.2 : CONCRETE, FORMWORK AND REINFORCEMENT
BILL NO.3 : MASONRY
BILL NO.4 : WATERPROOFING
BILL NO.5 : ROOF COVERINGS
BILL NO.6 : CARPENTRY AND JOINERY
BILL NO.7 : CEILINGS PARTITIONS AND ACCESS FLOORING
BILL NO.8 : FLOOR COVERINGS
BILL NO.9 : IRONMONGERY
BILL NO.10 : METALWORK
BILL NO.11 : PLASTERING
BILL NO.12 : TILING
BILL NO.13 : PLUMBING AND DRAINAGE
BILL NO.14 : PAINTWORK
BILL NO.15 : EXTERNAL WORKS
BILL NO.16 : PROVISIONAL SUMS

SECTION NO. 2 : GARAGE


BILL NO.1 : EARTHWORKS
BILL NO.2 : CONCRETE, FORMWORK AND REINFORCEMENT
BILL NO.3 : MASONRY
BILL NO.4 : WATERPROOFING
BILL NO.5 : ROOF COVERINGS
BILL NO.6 : CARPENTRY AND JOINERY
BILL NO.7 : CEILINGS PARTITIONS AND ACCESS FLOORING
BILL NO.9 : METALWORK
BILL NO.10 : PLASTERING
BILL NO.11 : PLUMBING AND DRAINAGE
BILL NO.12 : PAINTWORK

ELECTRICAL PORTION
MAIN BUILDING - SMALL POWER & LIGHTING REQUIREMENTS
DISTRIBUTION BOARDS & EQUIPMENT
CABLES AND TERMINATIONS
EARTHING & BONDING
CIVIL WORKS
SWITCHES & SWITCHED SOCKET OUTLETS
POWER SKIRTING & ACCESSORIES
LIGHTING & ACCESSORIES.
AUDIO, VISUAL & SECURITY ACCESSORIES
PROVISIONAL SUM 30000

GARAGE - SMALL POWER & LIGHTING REQUIREMENTS


DISTRIBUTION BOARDS & EQUIPMENT
CABLES AND TERMINATIONS
EARTHING & BONDING
CIVIL WORKS
SWITCHES & SWITCHED SOCKET OUTLETS
LIGHTING & ACCESSORIES
GARAGE ACCESSORIES
PROVISIONAL SUM 5000

GENERAL ELECTRICAL ACCESSORIES


PROVISIONAL SUM 15000