BE46-122-03 J52 Switches

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

ITY &

ED QUAL LESS
R T
ASSU ICE COS
V
S E R
9001 Series J52
ISO
® Refrigerant
Level Switches

Magnetrol Model J52 refrigerant level switches are float


actuated units designed for use on liquids with 0.60 specific Model J52 Refrigerant Level Switch
gravity and above. They utilize the Magnetrol magnetic prin-
ciple to assure dependable performance.

FEATURES
* Temperatures from: -45°C to +40°C (-50°F to +100°F).
* Maximum working pressure to 20.5 bar (300 PSIG).
* Housing is completely sealed against entrance of mois-
ture, preventing internal frost formation.
* Conduit seal with 610 mm (24") lead wires prevents
entrance of moisture laden air into the switch housing.
* Float chamber is a welded assembly fabricated from two
low carbon steel sections.
* High and low level switch actuation is easily field
adjustable between 13 mm (0.50") and 38 mm (1.50"),
factory set for 38 mm (1.50").
* Vibration resistant switch mechanism has been specifi-
cally developed to provide reliable and troublefree opera-
tion.
* Housing cover seal of Viton A o-ring is used between
housing cover and base to provide an air tight seal.
* Housing base can be rotated 360°.
* Dry contact switch mechanisms available for -30°C
(-20°F) or for excessive vibration conditions.
* Baffle plate provided with the switch mechanism to pre-
vent electrical wiring interference.
* Choice of enclosure:
NEMA 4x, black steel cover
NEMA 4, transparant Lexan® cover
NEMA 4x/7/9, explosion proof.
* Used with most commercial refrigerants including
Ammonia, Freon, Methyl, Chloride and Sulphur Dioxide.

AGENCY APPROVALS
Agency Model No. Approval
J52-41X1-00X
CENELEC EEx d II C T6
J52-41X2-00X➀
J52-41X1-00X
CSA Non-hazardous NEMA 4X
J52-41X2-00X
J52-41XX-00X Non-hazardous NEMA 4X
FM Class I, Div. 1, Groups C & D
J52-41XX-00X
Class II, Div. 1, Groups E, F & G

Chamber assembly must be fitted with a CENELEC
housing Lexan® is a registered trademark of General Electric

Worldwide level and flow solutions


PRINCIPLE OF OPERATION
2 Pivot
A permanent magnet ➀ is attached to a pivoted switch actu-
ator ➁. As the float ➂ rises following the liquid level, it rais- 5 Return
spring
es the attraction sleeve ➃ into the field of the magnet, which
in turn snaps against the non-magnetic enclosing tube ➄ 4 1
actuating the switch. The enclosing tube provides the static 3
pressure boundary between the switch mechanism and the
process.

Rising level Falling level


SELECTION DATA
Model Number
Housing Switch With 3/4" NPT With 3/4" Socket
Connection Weld Connection DIMENSIONS IN mm (inches)
NEMA 4x with Mercury J52-4101-001 J52-4111-001
Blk. Stl. Cover Dry Contact J52-4101-002 J52-4111-002 Rotation clearance
NEMA 4x: 108 (4.25)
NEMA 4 with Mercury J52-4107-003 – NEMA 4x/7/9:152 (6.00)
transparent
Lexan cover
® Dry Contact J52-4107-004 –

NEMA 4X/7/9 Mercury J52-4102-001 J52-4112-001


Explosion
Proof Dry Contact J52-4102-002 J52-4112-002
381
1/2" NPT cable entry (15.00)
may be rotated
through 360°

610 (24) lead wires


furnished

254
(10.00)
3/4" NPT or
3/4" Socket Weld

Actuating Liquid Specific Gravity RISING LEVEL R


Levels 0.60 0.80 1.00 1.20 1.30 1.40 1.50 1.60 1.70 L
17 28 34 39 41 42 44 44 46
R FALLING LEVEL
(0.68) (1.12) (1.37) (1.55) (1.62) (1.68) (1.74) (1.77) (1.83) 146
(5.75)
52 59 64 67 68 69 71 71 72
L (2.05) (2.33) (2.52) (2.65) (2.71) (2.74) (2.80) (2.83) (2.86)

71
3/4" NPT or (2.81)
3/4" Socket Weld

108
(4.25)

QUALITY ASSURANCE - ISO 9001

THE QUALITY ASSURANCE SYSTEM IN PLACE AT MAGNETROL GUARANTEES THE HIGHEST LEVEL OF QUALITY DURING THE
DESIGN, THE CONSTRUCTION AND THE SERVICE OF CONTROLS.
OUR QUALITY ASSURANCE SYSTEM IS APPROVED AND CERTIFIED TO ISO 9001 AND OUR TOTAL COMPANY IS COMMITTED TO
PROVIDING FULL CUSTOMER SATISFACTION BOTH IN QUALITY PRODUCTS AND QUALITY SERVICE.

PRODUCT WARRANTY

ALL MAGNETROL MECHANICAL LEVEL CONTROLS ARE WARRANTED FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR
5 FULL YEARS FROM THE DATE OF ORIGINAL FACTORY SHIPMENT.
IF RETURNED WITHIN THE WARRANTY PERIOD; AND, UPON FACTORY INSPECTION OF THE CONTROL, THE CAUSE OF THE CLAIM IS DETERMINED TO BE COV-
ERED UNDER THE WARRANTY; THEN, MAGNETROL INTERNATIONAL WILL REPAIR OR REPLACE THE CONTROL AT NO COST TO THE PURCHASER (OR OWNER)
OTHER THAN TRANSPORTATION.
MAGNETROL SHALL NOT BE LIABLE FOR MISAPPLICATION, LABOR CLAIMS, DIRECT OR CONSEQUENTIAL DAMAGE OR EXPENSE ARISING FROM THE INSTALLA-
TION OR USE OF THE EQUIPMENT. THERE ARE NO OTHER WARRANTIES EXPRESSED OR IMPLIED, EXCEPT, SPECIAL WRITTEN WARRANTIES COVERING SOME
MAGNETROL PRODUCTS.

BULLETIN N°: BE 46-122.3


EFFECTIVE: MAY 1998
UNDER RESERVE OF MODIFICATIONS SUPERSEDES: May 1991

BELGIUM Heikensstraat 6, 9240 Zele OUR NEAREST REPRESENTATIVE


Tel. (052) 45.11.11 Fax (052) 45.09.93
DEUTSCHLAND Schloßstraße 76, D-51429 Bergisch Gladbach-Bensberg
Tel. (02204) 9536-0 Fax (02204) 9536-53
FRANCE 11, Rue A. Einstein, Espace Descartes, 77420 Champs-sur-Marne
adresse postale: 77436 Marne-la-Vallée Cédex 2
Tel. (0) 164.68.58.28 Fax. (0) 164.68.58.27
ITALIA Via Arese 12, I-20159 Milano
Tel. (02) 607.22.98 (R.A.) Fax. (02) 668.66.52
UNITED Unit 1 Regent Business Centre
KINGDOM Jubilee Road Burgess Hill West Sussex RH 15 9TL
Tel. (01444) 871313 Fax (01444) 871317
INDIA B4/115 Safdurjung Enclave, New Delhi 110 029
Tel. 91 (11) 6186211 Fax 91 (11) 6186418

You might also like