Troubleshooting IPS Upgrade in RW6 System
Troubleshooting IPS Upgrade in RW6 System
Troubleshooting IPS Upgrade in RW6 System
Configuration guidelines
1. Node folder for all ips nodes in the system
It is highly recommended that there is a folder for each IPS node under
/hd0a/<system>/HOME/ipsdata on DSQC1000.
The folder may be empty if there is no configuration needed for this node, but it should exist
in this three. New folder can be created using Filezilla.
Expected result:
/hd0a/<system>/HOME/ipsdata
/hd0a/<system>/INTERNAL/firmware
Expected result:
rootfs on / type rootfs (rw)
/dev/root on / type jffs2 (rw,relatime)
devtmpfs on /dev type devtmpfs (rw,relatime,size=94156k,nr_inodes=23539,mode=755)
proc on /proc type proc (rw,relatime)
devpts on /dev/pts type devpts (rw,relatime,gid=5,mode=620)
tmpfs on /dev/shm type tmpfs (rw,relatime,mode=777)
tmpfs on /tmp type tmpfs (rw,relatime)
sysfs on /sys type sysfs (rw,relatime)
/dev/mtdblock1 on /mnt/user type jffs2 (rw,noatime)
192.168.126.1:/hd0a/RW6.04.0123/HOME/ipsdata on /mnt/user/home/ipsuser/ipsdata type
nfs
(rw,relatime,vers=3,rsize=1024,wsize=1024,namlen=40,soft,nolock,nordirplus,proto=udp,t
imeo=11,retrans=3,sec=sys,mountaddr=192.168.126.1,mountvers=3,mountproto=udp,lookupcac
he=none,local_lock=all,addr=192.168.126.1)
192.168.126.1:/hd0a/RW6.04.0123/INTERNAL/firmware on
/mnt/user/home/abbadmin/install_repo type nfs
(rw,relatime,vers=3,rsize=1024,wsize=1024,namlen=40,soft,nolock,nordirplus,proto=udp,t
imeo=11,retrans=3,sec=sys,mountaddr=192.168.126.1,mountvers=3,mountproto=udp,lookupcac
he=none,local_lock=all,addr=192.168.126.1)
Expected result:
ABB Update List:
OleOS OleOS.sp.ecpu.install #appinfo Ole OS Service Pack 1 Oct 04 2016 10:43:40 IST
ips ips.ecpu.install #appinfo IPS v4.60.3 09/29/2016 08:56:30
Expected result:
shared folders :
sharename [install_repo] -> localpath [/home/abbadmin/install_repo]
sharename [ipsdata] -> localpath [/mnt/user/home/ipsuser/ipsdata]
5. Check that the other nodes has mounted to these shared folders.
Use command on PIB console (example shows this command for node 5, repeat for other
nodes in system):
node 5 fo m
Expected result:
mounted file-object-shares :
localpath [/home/abbadmin/install_repo] -> dnet[1]:macid[1], sharename [install_repo]
- (fs:NFS)
localpath [/home/ipsuser/ipsdata] -> dnet[1]:macid[1], sharename [ipsdata] - (fs:NFS)
Expected result:
ABB Update List:
OleOS OleOS.sp.ccpu.install #appinfo Ole OS Service Pack 1 Sep 20 2016 15:58:36 IST
ips ips.ccpu.install #appinfo IPS v4.60.3 09/29/2016 08:53:11