PD Series PAGING MICROPHONES

24 Ch Desktop Paging Microphone PD1240


254 Ch Desktop Paging Microphone PD1280

PD1240 and PD1280 are the two of the more popular paging microphones
that incorporate soft touch buttons and improved sound quality. All essential
PD1240 PD1280 features such as priority level assignment, multipoint paging, illuminated
gooseneck microphone and volume controls are included.

PD1240 is a 24 buttons zone control with 4 fixed groups and ALL CALL,
suitable for small setup.

For larger installations of up to 254 zones, PD1280 will fit into the require-
ment which comes with large LCD panel and programmable 9 priority
levels.

Features
Sensor touch keypad with impressive outlooks
LED indicators for PD1240 and large LCD display for PD1280
Suitable for multipoint paging with priority level setup
Built in chime with selectable tone for PD1280
Adjustable volume controls for chime and microphone
Name setting at PD1280 Application Schematic
Compatible with Matrix Controller , TD Series of Zone Decoder
and IP Clients iPX5155
PD1280
Mic Nbr 2
Technical Specifications
PD1280 PD1280
PD1240 PD1280
TD6400 Mic Nbr 1 EX2800 Mic Nbr 3
Operating voltage 24V DC via EX2800 with local power adaptor 12V DC
Power consumption 1.2 W 1.3 W via adaptor
EX2800 EX2800
Zone selection 24 zone keys, Numerical keypad with
12V DC Cat 5e 12V DC
Group, All Call Group, All Call via adaptor via adaptor
Switching selection Sensor touch keypad Cat 5e Cat 5e
Microphone Gooseneck condenser capsule ; unidirectional TD6240 Zone Decoder
Output impedance 600 Ohm
Output level 1.2V balanced line output (+4dBU) MX2222
Output controls Chime, mic volume Pre-amplifier Mixer ZS5121 Zone Selector

Data connections RS485; 19.2 kbps


Power Amplifier
Cabling to decoder 2 pair screen; 22 AWG / Cat 5e
Recommended operating distance 500m max (18 AWG cable)
Compatible interfacing device MxP2288, TD6240, TD6080, TD6400
Chime 4 tone up and 4 tone down
Speakers
Indicators Zone, power, audio, data, gooseneck ring LED
Displays NIL LCD display; white back
illumination
Frequency response 100 - 12 kHz @ 1KHz +/- 3 dB
S / N ratio >65 dB @ 1 KHz

Gooseneck mic length 370 mm


Dimension (W x H x D) 230 x 192 x 65 mm ( Excluding Mic)
Weight 0.75 kg 0.85 kg
Packing information
Qty per carton : 1 unit
LxWxH : 525 x 270 x 85 mm
Weight : PD 1240 - 1.90kg ( incl adaptor )
: PD 1280 - 2.00kg ( incl adaptor )

scan for www.ampereselectronics.com


updates
Page 19
PAGING MICROPHONES
Emergency Paging Panel EP1200

EP1200 ; Emergency Paging Microphone is one of the


most important equipment in PA installation, essential to
make highest priority broadcast during emergency
situation. It allows direct paging to all zones and bypass
any active BGM or normal paging in progress.

EP1200 has built in siren tone generator which can be


activated at front panel as well as remotely when connect-
ed to FAP or external distress switch. Communication port
is available for external interface such as connecting to
iPX5155 of Amperes IP PA System.

Features Rear view of EP1200


EP 1200

Built in siren tone generator (constant signal)


EM ER GEN C Y PAG IN G PAN EL

Visual FIRE indicator


BALANCE LINE LEVEL

VOLUME MESSAGE INPUT PRE-AMP INPUT MAIN OUTPUT


MESSAGE SIREN RELAY POWER +
PIN CONFIGURATIONS :
DC 24V TRIG TRIG CONT RS485 AUDIO + DATA
1 - Data A
NO MIC SIREN 1 8 2 - Data B

External voice message activation


+ A B 3 - NC
4 - Ground
5 - +24V
6 - Pre out -
3 - Ground
4 - Pre out +
Another Quality Product From
amperes electronics

Dual mode siren tone activation


MADE IN MALAYSIA

Dry contact when paging mic is activated Audio and data link port
Priority paging via front panel microphone, bypassing all other audio sources Pre-amp in, EVAC message and audio out
Output level controls for siren and message / paging microphone Mic and siren volume adjust
Message, Siren trigger
Relay contact
RS485 data port

Technical Specifications Application Schematic


Power requirement 24V DC Application in conventional system
Power consumption 3.5W
Pre-amplifier Mixer
MICROPHONE Trigger Switch
Mic sensitivity -72 dB Omni directional
Impedance 600 Ohm line out
contact
Frequency response 300 ~ 8 KHz
line
EVAC Message Player
SIREN EP1200
Siren frequency Continuous at 8 KHz
Siren duration Continuous when activated
Siren activation Front test switch / remote contact Power Amp
all call
Input channel Pre-amplifier output, message recorder activation
Output level Balanced line out +4dBU max
Priority sequence Paging mic - siren - message - pre amp in Zone Selector 100V
Indicators Front FIRE with backlight illumination
Dimension (W x H x D) 482 x 88 x 180 mm
Weight 2.80 kg
24V
O/R

Volume Controls

Speakers
Packing information
Carton size : 555 (L) x 295 (W) x 165 (H) mm
Gross weight : 3.75 kg
1 unit per carton

scan for www.ampereselectronics.com


updates
Page 23
Fire Alarm Interface INPUT SOURCES & CONTROLS

improved Fire Alarm Interface FI6000 MK II


Fire Alarm Interface Extender FI6001

FI6000 MK II is an improvised phase evacuation controller, which is an essential Features


intermediary device between Fire Alarm Panel and PA System. It enables zone
controls and playback of various EVAC messages in pre-programmed sequences of LAN connectivity for ease of setup and controls
activities. The orderly and automated activities upon receiving signals from Fire Available in 24 channels and can be extended with FI6001
Alarm Panel (FAP) are part of compliance to EN54 or BS5839 Part 8 standards.
Integrated with Amperes products via RS485 and dry contacts
FI6000 has been improved and LAN interface has been added for the ease of Bi colour LEDs for easy identification of status
programming via web interface instead of application software. Attractive and user Most suitable Fire Alarm Interface for Phase Evacuation activities
friendly UI has been developed for better user experience during configurations.
User friendly GUI
FI6001 is an extension unit to the main FI6000 controller if the number of channels
are more than 24. It can be able to be extended of up to 16 units, which is equivalent
to 384 receiving ports. Rear View:

DC 24V CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9 CH10 CH11 CH12 CH13 CH14 CH15 CH16 CH17 CH18 CH19 CH20 CH21 CH22 CH23 CH24

+ SLAVE CH1 CH2 CH3 CH4 ETHERNET


RS485 LINK

Creating schedules has been made simpler with user iendly GUI A B A B
RESET

500mA another quality product from


RELAY OUTPUT FIRE ALARM INTERFACE INPUT FOR CHANNEL 1 TO 24
amperes electronics

RS485 &
extension Ethernet port External trigger
link Output relay contacts ( from FAP )

Application Schematic
Ch 25 to 48
FI6001

Ch 1 to 24 Extension link
PC
Schematic Diagram
Connect through LAN FI6000 MK II
Input voltage 24 V DC ; 1 A
Power consumption ( all triggered ) 21 W ; 0.9 A
24 ports RS485 data / RS485 data / dry contact
Input channels
dry contacts for
Max expandable unit 16 ; max 384 channels MR1301 MK II
other applications
Trigger method Dry contact, NO EVAC Player
audio
Output channels ( dry contacts ) 4 data / dry contact
Output contact rating 3A
EP1200
Output contact modes ON, OFF Emer. Paging
Contact connectors Mini Phoenix
Indicators Channel bi colour LED
Data / Contact
Dry contact LED Override
Pre-amplifier mixer
Communications RS485 ; 19.2 kbps
LAN 10/100 Base T TD6240
Zone Decoder
User interface Web browser : Google, Firefox
Dimensions 482 x 44 x 180 mm trigger switching
& 100V line audio
Weight 1.9 kg
ZS Series
Zone Selectors
Packing information
Carton size : 555 (L) x 295 (W) x 95 (H) mm Paging Mic To Speakers
Gross weight : 2.55 kg & VC Override
1 unit per carton

scan for www.ampereselectronics.com


updates
Page 27
INPUT SOURCES & CONTROLS
MR1301 EVAC Message Player / Voice Recorder
MK II
improved

MR1301 - EVAC Voice Message player has been further upgraded, notably Features
the way the unit shall be setup. LAN port has been added to enable configu-
ration to be performed smoothly using web interface with user friendly GUI. Up to 32 GB of memory space for large file storage and recording
Tasks such as uploading of files, combining or grouping messages, and key
Web technology with user friendly GUI for setup, upload files and configurations
assignments shall all be done via web browser or the front button keys.
Message playback via front button / rear remote triggering
As one of the most important equipment in EVAC, MR1301 MK II shall High quality MP3 audio playback of up to 320 kbps with 64 kbps IMA ADPCM
perform beyond the user’s expectation by providing precise message
voice recording
delivery and clarity, to enable timely and systematic evacuation procedures
in time of distress. Apart from the above application, it can also be used as Flexible message configuration in every memory bank, ie. multiple files in single
general message player such as prayer playback, voice recording and other button with delay setting in between
usages as required.
Flexible message playback sequencing
Event logging with time stamp for every message played, triggered and powered.
Built in 5 band equalizer
File / setting back up and restore
Simple firmware updates

Application Schematic
External voltage free contacts for
message trigger ( up to 16 contacts )

Alternative Bypass :
Audio and Trigger
direct to EP1200 MR1301 MK II
Technical Specifications
Note :
With direct
Operating voltage 24V DC ; 1A connection to
EP1200, message MX2222
Power consumption 2.4 W ( 0.1 A )
shall bypass
Standby consumption 1.7 W ( 0.07 A ) audio signal from
Data connection RS485 : Mini Phoenix connector, 19.2 kbps MX2222 with
higher priority
LAN : RJ45, 10/100 Base T
EP1200
Inputs Line in ; Unbalanced via RCA jack
Mic in ( recording ) : 1/4” balanced phone jack
Message trigger 16 memory banks : Front and rear Amp input
Playback format MP3, WAV
Voice recording MP3, 1 hour per message
Playback delay Yes Amplifier

Priority message cut Yes 100V Output


24V DC Override
User interface Google Chrome, Edge trigger to All Call
Remote view / control Yes ZS5121
Indicators LED, 2x18 Char LCD
Memory 16 GB non detachable SD card ( option for 32 ) 2 x 100V Audio
Dimensions ( W x H X D ) 482 x 44 x 180 mm 2 x 24V Override
Volume Controllers
Weight 2.0 kg

Packing information Speakers

Carton size : 555 (L) x 295 (W) x 95 (H) mm


Gross weight : 2.55 kg
1 unit per carton

www.ampereselectronics.com scan for


updates
Page 28
PRE-AMPLIFIER MIXER
MX2222
12 Inputs Pre-amplifier Mixer
MX2222 is a compact mixer suitable for commercial PA
applications with all features required to comply with EVAC
system such as priority muting.

It is also suitable for other general applications such as


audio mixing in meeting rooms, lecture theaters, house of
worships, etc.
Features 12 inputs of mic, BGM sources, ext.chime and mixer link for channel expansion
Auto muting with adjustable ducking level for Ch. 1,2, chime and line in
Priority muting with disable option for normal mixing mode
Switchable phantom power for mic channel 1 to 4
Dual output ; mixed line and BGM output for uninterrupted paging setup
Packing information
Independently adjustable BGM balance line output level
Carton size : 555 (L) x 295 (W) x 95 (H) mm
Gross weight : 2.9 kg Built in daisy chain source selector with last selection memory
1 unit per carton Bass and treble tone control
AC and DC power source for uninterrupted operation during power failure

MX2322
13 Inputs Dual Bus Pre-Amplifier Mixer new
MX2322 is a further refined pre-amplifier mixer with dual
bus outputs, suitable for both EVAC commercial PA
installations as well as for other general usage in meeting
rooms, function halls etc.

Connections has been made simpler with Phoenix connec-


tors, which is a preferred choice for fixed installations.

Features 8 mic / line, 2 RCA, 2 external lines and 1 paging mic high priority inputs
Switchable phantom power for Ch.1 to Ch.8
Gain controls for mic and line inputs
Assignable input to output A or B or both
Packing information Priority muting switch to override BGM sources
Carton size : 555 (L) x 295 (W) x 165 (H) mm Dual output A and B with separate record output channels
Gross weight : 4.0 kg
1 unit per carton
Low, Mid and High main tone controls for both outputs
AC and DC power source for uninterrupted operation during power failure

Technical Specifications
MX2222 MX2322

Operating voltage 220 ~ 240 V ac : 50 / 60 Hz / 24V DC


Current ( max ) 10 mA ( 240V ac ) / 100 mA ( 24V DC ) 40 mA ( 240V ac ) / 260 mA ( 24V DC )
Power consumption ( max ) 2.4W ( 240V ac / 24V DC ) 9.6W ( 240V ac ) / 6.3W ( 24V DC )
Inputs 6 x Mic + phantom power at Ch 1 to 4 8 x Mic / Line with gain controls + phantom power
2 x Line input with priority, 4 x RCA 2 x Line input with priority, 2 x RCA, 1 paging mic
Input impedance RCA : 47 k Ohm, Mic : 600 Ohm, Link : 10 k Ohm Line : 10 kOhm ; Mic : 15 k Ohm
Phantom power 12 V DC at Ch 1 to 4 ( Switchable ) 18V DC at Ch 1 to 8 ( Switchable )
Operating level ( Sensitivity ) -30 dBU ( mic ), +4 dBU ( line )
Input level ( max ) +10 dBU
Gain controls +20 dBU balanced / unbalanced
Crosstalk > 60 dB > 70 dB
Outputs 1 x line balanced, 1 x records unnbalanced 2 ( A & B ) line balanced, 2 x records unnbalanced
Output impedance ( Ohm ) 600 Ohm balanced 300 Ohm balanced
Tone controls 2 : Low / Mid ( 300 Hz ), Hi ( 10 kHz ) 3 : Low ( 100 Hz ), Mid ( 1 kHz ), Hi ( 10 kHz )
Frequency response 175 ~ 15 kHz 20 ~ 20 kHz
S/N ratio / THD + N > 60 dB / < 0.1% > 75 dB / < 0.1%
Connectors XLR-F ( mic in / line out ), 1/4” TRS ( line & mix in ) Mini Phoenix ( mic / line inputs and outputs )
1/4” TRS Unbal ( rec & BGM ), RCA RCA, RJ45 for Amperes PM1030 mic
Dimensions (WxHxD) 482 x 44 x 185 mm 482 x 88 x 185 mm
Weight 2.2 kg 3.3 kg

www.ampereselectronics.com scan for


updates
Page 30
POWER AMPLIFIERS PA2000 Series
PA2120 120W 100V
PA2240 240W 100V
PA2360 360W 100V
PA2480 480W 100V
PA2600 600W 100V

PA2000 Series of power amplifiers has been a workhorse of Features


powering the PA setups for decades. They are available in various
power ratings to choose from to suit the loading requirement. Available in various ratings ; from 120W to 600W 70 or 100V line
4 Ohm speaker connection available with 25V ~ 48V output
With our continuous product improvement effort, we had improved Thermal protection by muting input signal (typically 75 deg at heat sink)
the performance and reliability in line with ever changing needs of
the industry. Momentary short circuit protection
In rush current limiter
Temperature dependent dual speed cooling fan
Balanced input signal with gain control and selectable grounding option
AC and DC operation for uninterrupted operation during power failure

4 Ohm / 70 and 100V line output


24V DC battery input

PA 2600
Packing information
DC INPUT 30A SPEAKER OUTPUT

POW ER AMPLIFIE R
600W 100V Another Quality Product From WARNING !
AMPERES ELECTRONICS TO REDUCE THE RISK OF FIRE OR

Carton size : 550 (L) x 465 (W) x 180 (H) mm


ELECTRIC SHOCK DO NOT EXPOSE THIS
MADE IN MALAYSIA EQUIPMENT TO RAIN OR MOISTURE.

Gross weight :
BALANCED INPUT
1V / 10K
INPUT LINK

AC 220 - 240V 4A

PA2120 : 13.10 kg CAUTION


RISK OF ELECTRICAL SHOCK
DO NOT OPEN
GROUND
50/60 Hz

PA2240 : 13.85 kg
PA2360 : 17.40 kg
PA2480 : 19.65 kg Signal input & link
PA2600 : 21.30 kg Gain Control
1 unit per carton
Ground lift
switch

Technical Specifications
PA2120 PA2240 PA2360 PA2480 PA2600

Ratings ( rms ) 100V output 120 W 240 W 360 W 480 W 600 W


Operating voltage 220 ~ 240 V AC or 24 V DC back up supply
Power consumption ( 240V ac ) 255 VA ( 1.0 A ) 497 VA ( 1.9 A ) 731 VA ( 2.8 A ) 996 VA ( 3.8 A ) 1069 VA (4.1 A )
Current consumption ( 24V DC ) 6.1 A 10.6 A 16.3 A 22.3 A 23.1 A
Standby current ( 24V DC ) 0.2 A 0.3 A 0.4 A
Input signal ( sensitivity ) 1V ( +4 dBU ) / 10 k Ohm via Phoenix connectors
Input gain controls -40 to +4 dBU
Outputs 70 / 100V line and 4 Ohm
4 Ohm output voltage 22 V 31 V 38 V 43.8 V 48 V
Output impedance ( max load ) 83 Ohm 42 Ohm 27 Ohm 20 Ohm 16.6 Ohm
Frequency response 70 - 15 kHz @ 1 kHz +/- 3dB
S/N ratio > 70 dB @ 1 kHz, 1V
THD + N < 0.18 %
Protections Thermal, short circuit, overload, fuse, in-rush current
Cut off temperature 75 deg C
Cooling system Auto temperature controlled cooling fan
Indications LED : Power, Signals
Dimensions ( WxHxD ) mm 482 x 88 x 335
Net weight ( kg ) 11.40 12.35 16.20 17.95 19.60

www.ampereselectronics.com scan for


updates
Page 36
MONITORING AND CHANGEOVER
AX3800 8 Duty / 1 Standby Auto Amplifier Changeover Panel

improved

AX3800 has been improved further, offering greater flexibility and simplicity Features
for amplifier fault changeover setup. Cascading is now made easier to
enable 1 standby to cater for 16 duty power packs. Cater for 8 duty and 1 standby
Expandable for 1 standby to cater for more than 8 duty amps.
With precise circuit design, amplifier fault detection period is greatly reduced Built in Pilot Tone generator, transmit at intervals and senses at sequence to
to initiate timely changeover to standby unit. The internal pilot tone genera- protect amplifiers
tion at 20KHz is set at optimum interval to avoid unnecessary loading to
amplifiers. Overloading protection by allowing only a single take over
Prioritised changeover which higher numbered amplifier shall be preferred for take
Changeover shall occur at both input and output of amplifiers, making it over if more than two units are down
suitable for application in a matrix system. Priority and single changeover
ensures overloading of standby amplifier is avoided, thus providing a reliable Short fault detection time from 7 to 15 seconds
and uninterrupted system at most times. Changeover at input and output section simultaneously ; suitable for matrix system
installations
Input link switch ; making connection of sources easier
Audio in / out with Cascade port for
channel link switch channel expansion Channel isolation switch for unused or un-monitored channel

BALANCE AUDIO SIGNAL


another quality product from
amperes electronics
Individual channel status indicators ; normal, fault and changeover
CASCADE
AMP1 AMP2 AMP3 AMP4 AMP5 AMP6 AMP7 AMP8 STDBY INPUT OUTPUT

O PEN LINK O PEN LINK O PEN LINK O PEN LINK O PEN LINK O PEN LINK O PEN LINK

DC 24V AMP1 AMP2 AMP3 AMP4 AMP5 AMP6 AMP7 AMP8 STDBY
IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN
+ ADD
AMP. BYPASS R
1 8 FAULT
NO RS 485 AMP.CHANGEOVER
CONTACT A B am per es
Model : AX3800 MKII
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
ON ON
DC input 24V Max. 500mA
AMPERES ELECTRONICS MADE IN MALAYSIA

Amp in / out Ch detection Unit address setting


Application Schematic
terminals bypass Fault Contact Standby Duty Duty
RS485 data port Amplifier Amplifier Amplifier

Technical Specifications 100V


Operating voltage 24V DC ; 1A Input Sources
Power consumption 2.5 W ( 0.11 A )
Standby consumption 2.3 W ( 0.95 A )
audio +
Input signal 8 Ch balanced line signal PT audio
Input impedance 10 k Ohm
Audio output gain Unity
Pilot tone interval 8 seconds / channel 1
100V 8
Pilot tone frequency 20 k Hz ( +/- 5% ) 100V Emergency
Detection line 70 / 100 V line Paging
24V DC
Detection level 5 V rms min
AX3800 overriding
Failure detection time 20 seconds ( max )
Cascade AX3800 if more than 8 duty amps
Failure recovery time 20 seconds ( max ) are installed
Zone load rating 500W 100V line max ( 1000W on request )
8 1
Status indication LED Normal ; Fault ; Changeover Speaker Zone
Changeover alert Buzzer with switch Selector
24V DC
Changeover section Input and output simultaneously overriding
Dimensions ( W x H X D ) 482 x 88 x 180 mm Volume
Weight 3.55 kg Controller

Packing information
Carton size : 555 (L) x 295 (W) x 165 (H) mm Speakers
Gross weight : 4.50 kg
1 unit per carton

www.ampereselectronics.com scan for


updates
Page 40
MONITORING AND CHANGEOVER
8 Ch Speaker Line Surveillance LS4808
16 Ch Speaker Line Surveillance LS4816

LS4808 offers 8 channels of speaker line monitoring while LS4816 has 16


Features
channels. LS Series is a great tool of monitoring the speaker line integrity such 8/16 channel speaker line monitoring with basic and advance level setup
as ground leakage, short and open circuit via impedance measurement method. Impedance measurement method allowing cabling branching and no end of
End of Line resistors are not required and circuit branching is allowed, thus line resistors or coupling capacitors.
allowing a more flexibility in cabling works.
Short burst test signal, minimizing interruption to PA operation
LS is powered by powerful processor and its unique measurement algorithm Detection interval setting from 1 min to 48 hours with ad hoc testing trigger
enables it to perform tasks at high speed with optimum accuracy. Setup is simple Faulty circuit isolation option
but for the more advanced requirement, LS also allows deviation limits, useful for Fault alert indicators and user friendly setup menu
more sensitive installations, such as power plants, military, etc.
Built in impedance meter, range from 10 Ohm to 10 K Ohm
It can be installed to run at intervals with user setting or link to a timer for specific Aux 24V DC output for volume controller overriding during testing mode
time operation, to avoid disturbances to occupants of the building.

Technical Specifications
Rear View LS4808:
LS4808 LS4816
TD6400 DC 24V EXT TRIG
AMP 1 ZON 1 AMP 2 ZON 2 AMP 3 ZON 3 AMP 4 ZON 4 AMP 5 ZON5 AMP 6 ZON 6 AMP 7 ZON 7 AMP 8 ZON 8
FAULT RS485 LINK
AMP.1 ZONE 1
+ TRIGG NO NO A B AMP.8
ZONE 8

Operating voltage 24V DC via PS9400 FAULT O/P CONTACT

RS485
DRY CONT MAX 3A
Quality Product From
EXT TRIGGER
AMPERES ELECTRONICS

Power consumption
AMPLIFIER INPUTS - ZONE OUTPUTS FOR ZONE 1 TO ZONE 8

3.8W 4.9W
LS4806

Capacity 8 16
Rear View LS4816:
Impedance detection range 10 to 10 K Ohm
AMPLIFIER INPUTS - ZONE OUTPUTS FOR ZONE 1 TO ZONE 8

Power measurement range


AMP.1 ZONE 1

10 to 1000W 100V line LS 4816


LINE S URV EILLA NCE
AMP 1 ZON 1 AMP 2 ZON 2 AMP 3 ZON 3 AMP 4 ZON 4 AMP 5 ZON 5 AMP 6 ZON 6 AMP 7 ZON 7 AMP 8 ZON 8
AMP.16

FAULT O/P CONTACT


ZONE 16

Measurement accuracy +/- 3% within range


RS485

EXT TRIGGER
DRY CONT

LS4816
MAX 3A

Pilot tone injection frequency 1 kHz DC 24V


+
EXT
TRIGG
TRIG
NO
AMP 9 ZON 9 AMP 10 ZON 10 AMP 11 ZON 11 AMP 12 ZON 12 AMP 13 ZON 13 AMP 14 ZON 14 AMP 15 ZON 15 AMP 16 ZON 16
FAULT
NO
RS485 LINK
A B

Pilot tone signal output level 5V sine Quality Product From


AMPERES ELECTRONICS
AMPLIFIER INPUTS - ZONE OUTPUTS FOR ZONE 9 TO ZONE 16

Monitor triggering Auto / remote trigger


Transmittal detection period 0.5 seconds per channel (max)
Detection interval User preset from 1 min to 48 hrs
Vol Control Override RS485 data link
Sensitivity setting User preset at each channel
Indicators - LED Normal, Fault, Buzzer, Auto run External trigger by timer / manual Fault dry contact
Display LCD 2 x 16 characters w back light
Audible output signal Continuous buzzer with Off option
Dry contact setting 3A
DC output in detection mode 24V DC for individual channel
Please refer to schematic diagram available in manual for configurations
Data interface RS485 : 19.2 kbps
Dimensions (W x H x D) 482 x 44 x 180 mm 482 x 88 x 180 mm
Weight 2.15kg 3.25kg

Packing information
Carton size : LS4808 : 555 (L) x 295 (W) x 95 (H) mm
LS4816 : 555 (L) x 295 (W) x 165 (H) mm
Gross weight : LS4808 : 2.75 kg
LS4816 : 4.00 kg
1 unit per carton

scan for www.ampereselectronics.com


updates
Page 41
AMP MONITOR PANEL / SOURCE SELECTOR
AM4120 12 Ch Amplifier Monitor Panel

AM4120 shall be used to monitor amplifier outputs of 70 / 100V line at the Features
rack which is equipped with level meter, amplifier output LED and speaker
for audio monitoring. It can also be used as a tool to calibrate sound output 12 inputs for 70 / 100V line amplifier outputs
level of each amplifier from the rack. Dual mode monitoring with continuous signal indicator
Audio monitoring with volume control

Technical Specifications AMP 1 AMP 2 AMP 3 AMP 4 AMP 5 AMP 6 AMP 7 AMP 8 AMP 9 AMP 10 AMP 11 AMP 12 AMP IN 1
DC 24V AMPLIFIER MONITOR PANEL WIRING DIAGRAM
+ AM 4120
AMP IN - FROM AMPLIFIER OUTPUT AMP IN 12
Ano th er Qua lity Produc t From
PLEASE OBSERVE LINE POLARITY
AMPERES ELECTRO NIC S

Operating voltage 24V DC via PS9400 PSU AMP 1 TO ZONE SELECTOR / SPK

Power consumption 50 mW
CAUTION : PLEASE OBSERVE POLARITY AMP 12

Amplifier inputs 12 : 70 / 100V line


Rear View: Inputs from power amplifiers
Monitoring mode Audio : 1W speaker with 5 presets
Visual : segment LED level meter
LED for all channels
Dimensions (W x H x D) 482 x 44 x 180 mm
Weight 2.15 kg
Packing information
Carton size : 555 (L) x 295 (W) x 95 (H) mm
Gross weight : 2.80 kg
1 unit per carton

SS6401 Audio Source Selector

SS6401 has 4 BGM source inputs via RCA jack with mono output suitable Features
for PA system. Input channels of different BGM output sources with different
line level has been equalized to the same level at output to avoid the trouble 4 input BGM sources
of adjusting the mixer gain whenever a source is changed. Input level balancing for constant output

Technical Specifications
Operating voltage 24V DC via PS9400 PSU
Power consumption 3.6 W ; 0.15 A
Input connections RCA mono DC 24V CAS S TUN ER INPUT SENSITIVITY / IMPEDANCE
TUNER : 200mV / 47K
CD : 500mV / 47K

Input level / impedance CD : 2V / 47 k Ohm


DC SUPPLY RATING : OUT PUT
24V DC, 150 mA CASS : 200mV / 47K
( U N BALAN C E ) AUX CD
1 V M AX AUX : 200mV / 47K

+ -

Tuner : 600 mV / 10 k Ohm


Cass : 500 mV / 10 k Ohm Rear View: Inputs for audio sources
Aux : 1.25 V / 20 k Ohm RCA output
Output connection RCA mono ; 1V 600 Ohm
Gain / attenuation CD : -6 dB, Tuner : 4 dB
Cass : 6 dB, Aux : - 2 dB
Selection Daisy chain
Dimensions (W x H x D) 482 x 44 x 180 mm
Packing information
Weight 1.8 kg
Carton size : 555 (L) x 295 (W) x 95 (H) mm
Gross weight : 2.50 kg
1 unit per carton

www.ampereselectronics.com scan for


updates
Page 42
SPEAKER ZONE SELECTOR
ZS5062 6 Ch Speaker Zone Selector
ZS5122 12 Ch Speaker Zone Selector improved

ZS5062 and ZS5122 have been improved in its individual zone rating Features
with 1000W 100V line to meet the demand to increase zone loading in
Available in 6 and 12 zones ; expandable to 192 zones
today’s installations.
1000W 100V per zone rating
They differs from other zone selector, ie. they have fail safe feature Fail safe zone trigger during power or unit failure
which would ensure zone is always connected for paging if the unit itself
Remote zone triggering via analogue and RS485 data
failed. RS485 port is available for remote triggering and monitoring via
PMX software. Zone monitoring via PMX II software
Local paging override bypassing BGM
ZS5062 or ZS5122 can be stacked to form larger zone setup in big Flexible amplifier to zone configuration
installations.

DC 24V
+ -
RELAY RELAY Z RS485
TRIG CONT PR A B
UNIT ADD REMOTE SELECT

1-Z1
ZONE 1 TO 6
AMP 1 ZON1 AMP 2 ZON2 AMP 3 ZON3 AMP 4 ZON4 AMP 5 ZON5 AMP 6 ZON6

1-Z7
REMOTE SELECT
ZONE 7 TO 12
AMP 7 ZON7 AMP 8 ZON8 AMP 9 ZON9 AMP10 ZON10 AMP11 ZON11 AMP12 ZON12
rear view of ZS5122
1 2 4 8
2-Z2 2-Z8
3-Z3
4-Z4
5-Z5
6-Z6
3-Z9
4-Z10
5-Z11
6-Z12
Please refer to TD6240 brochure for schematic
7-24V 7-24V
Quality Product From ON
8-COM 8-COM
AMPERES ELECTRONICS AMPLIFIER INPUTS - ZONE OUTPUTS FOR ZONE 1 TO 6 AMPLIFIER INPUTS - ZONE OUTPUTS FOR ZONE 7 TO 12

Amp - Zone outputs


Remote trigger
Address setting
RS485 data port
E/M relay for All Call
Technical Specifications
ZS5062 ZS5122
Operating voltage 24V DC via PS9400
Power consumption ( idle ) 3.29 W 6.25 W
Power consumption ( All Call ) 0.72 W 0.96 W
Current consumption ( idle ) 0.14 A 0.26 A
Current consumption ( All Call ) 0.03 A 0.04 A
Max load / channel 1000W 100V line
Number of zones 6 12
Amplifier inputs 6 12
Zone selection Front panel switch & remote ( zone & all call )
Max cascade 16 units
Remote triggering - Ve triggered ( common ground )
Indicators Individual zone switch, all call and priority
Data communications RS485 : 19.2 kbps baud rate
Switching mode Individual , All Call
Local zone bypassed when remote trigger is activated
Operating temperature - 10 ~ 60 deg C
Dimensions (W x H x D) mm 482 x 44 x 180 ( 1 hu )
Weight ( kg ) 1.95 2.10
Packing information
Carton size : 555 (L) x 295 (W) x 95 (H) mm
Gross weight : ZS5062 : 2.55 kg
ZS5122 : 2.70 kg
1 unit per carton

www.ampereselectronics.com scan for


updates
Page 44
PAGING MIC ZONE DECODER
TD6240 24 Ch Zone Decoder

TD6240 is an intermediary equipment between Amperes PD series of Features


paging microphones and Amperes ZS series of speaker zone selectors.
It has 3 PD input circuits, enabling multi point paging setup from different Expandable and addressable to cater for more than 24 zones
areas. Decoded zones are connected to zone selectors through RJ45 Priority setting for multi point paging setup
jacks for zone switchings.
Selectable balanced audio output level (mic or line)
For system exceeding 24 zones, TD6240 can be stacked up to enable Compatible with most zone selectors with remote triggering port
254 zone switchings in total. Connects directly to ZS5601 / 5121 / 5062 / 5122 via remote triggering ports
using RJ45 connector

Rear View: DC 24V


+
LINE IN DATA
FROM PD2400 / 2800 VIA EX2800
LINE IN DATA LINE IN DATA
MAINS OUTPUT
LINE / MIC DATA DATA LINK UNIT ADD
TRIGG PORT 1 TRIGG PORT 2 TRIGG PORT 3 TRIGG PORT 4

G + - A B G + - A B G + - A B G + - A B A B 1 2 4 8 16 - - - - -
TD 6240
24 CH D ATA DE COD ER
MIC LINE

1 2 3 4 5 6 7 8 9 10
ON
MAINS OUTPUT
SELECT
NEGATIVE OUTPUT TO REMOTE TRIGGER ( ZONE SELECTOR )

Audio and data output Zone selector trigger


Output level select
From PD paging microphones

Application Schematic Technical Specifications

Operating voltage 24V DC


PD2400 / 2800
Paging Mic 2 Consumption 2.4W (100 mA)
PD1240 / 1280 Switching channels 24
Paging Mic 1
Cascade / max zones 8 (max 192 zones)
PD1900
Paging Mic 3 Input circuit 3
Cat 5e Output connection RJ45 to ZS zone selector
(Direct for (Triggering)
< 15m )
EX2800 w EX2800 w AUDIO
24V DC 24V DC
Input impedance (Ohm) Line : 10 K
2pr screen Output impedance 600 Ohm balanced
Freq response 70 ~ 15 KHz
TD6240
Cat5/ multicore Audio input Line balanced ( +4 dBU )
audio output cable for zone triggering Max audio output Line balanced ( +4 dBU )
(mic / line level)
Preamplifier Mixer ZS Series Zone Selector
DATA
Data protocol RS485
Baud rate 19.2 kbps
Dimension (W x H x D) 482 x 44 x 180 mm
Weight 1.90 kg
100V

Power Amplifier Speakers

Packing information
Carton size : 555 (L) x 295 (W) x 95 (H) mm
Gross weight : 2.45 kg
1 unit per carton

www.ampereselectronics.com scan for


updates
Page 46
POWER DISTRIBUTIONS
8 Ch Sequential Power Switcher SQ9815
SQ9815 is suitable for applications in PA, sound and AV systems, in
which it manages the powering sequence of every equipment in an
orderly manner. Random power switching of components within a
system may cause damage to the equipment and thus SQ9815 is a tool
of powering protection.

It also has built in surge protectors to kill harmful incoming power


Features spikes.

8 channel with 6A per channel; total load of 15A with surge protection
Technical Specifications
Cascade 2 units to form 16 channel setup
ON / OFF sequential switching Operating voltage 220 - 240V AC
Remote switching port via external noiseless contact Power consumption 50 mW (without load)
Output voltage 230 / 240V AC
AC output through IEC connectors with channel isolation via DIP switch
Max load / channel 6A
Ch. 8 with delay Off option for 2 min ; suitable for video projector connection Max total load 15A
Lock mode to avoid accidental switching Output connection IEC female socket
Max cascade 2 uts : total 16 channels
Surge protection L-N, L-E, N-E.
Clamping voltage 870V AC
Rear view Address setting Turn on sequence Step 1 to 8 incremental
REM
TRIG
CASC
LINK
RS485
A B
1~4 : ADD 1-2-4-8
5 :-
7 : OFF-MAS / ON-SLA
Turn off sequence Step 8 to 1 decremental
8 : ON / OFF BYPASS

1 2 3 4 5 6 7
ON
8 Step timing 2 seconds
Delay off option Channel 8 via DIP switch
AC 220-240V CHANNEL OUTPUTS Quality Product From
50/60Hz MAX : AC 240V 5A / CH AMPERES ELECTRONICS

Delay off timer 2 minutes


AC output connectors Remote trigger & cascade
Switch lock Via front switch
RS485 data port
Indicators AC mains, Ch. on, Lock
Dimensions (W x H x D) 482 x 44 x 180 mm
Weight 2.80 kg excl. accessories
Packing information
Carton size : 555 (L) x 295 (W) x 95 (H) mm
Gross weight : 3.55 kg
1 unit per carton

PS9400 is a rack mounted 24V DC regulated power supply designed for PA installations. It has built in changeover 24V DC Power Supply PS9400
relay which shall be connected to back up 24V DC battery bank to allow continuous and uninterrupted power
supply to the whole installation whenever the mains failed.

Features Technical Specifications


Operating voltage 220 - 240V AC
24V DC 4A output highly regulated PSU Output voltage 24V +/- 1 %
Output Fuse protection Rating 4A nominal ; max 5.5 A
Built in various protections No load consumption 50 mW
Back up battery overriding relay Efficiency 83 %
Indicators AC mains, battery input, DC output
Protection Built in surge protection
Short circuit
- 24V
+ BATT - BATT + 24 V
WARNING !
Overload (105% ~ 150% )
PRESS TO RESET
BREAKER
CAUTION
TO RE DUCE T HE RISK O F FIRE O R E LECTRIC
SHO CK DO NOT EX PO SE T HIS EQ UIPMENT RIS K O F ELE CTRICAL SHO CK
MAINS : 170-264V TO RA IN OR MO IST URE. DO NO T OPE N
AC 50 / 60HZ

Over voltage (115% ~ 135% )


Another Qu ality Pro duct F rom
IN OUT DC 5A AMPERES ELECTRONICS

Output DC protection Fuse


24V DC output Terminals Batt input and load ; barrier connectors
Back up input Dimensions (W x H x D) 482 x 44 x 180 mm
Weight 2.35 kg
Packing information
Carton size : 555 (L) x 295 (W) x 95 (H) mm
Gross weight : 3.00 kg
1 unit per carton

scan for www.ampereselectronics.com


updates
Page 47
POWER DISTRIBUTIONS
BC9740 24V DC Automatic Battery Charger

BC9740 is the next generation of innovative Battery Charger, which has been engineered to meet the
requirement of installers and users alike. It is compact in 1 HU height, built with the latest technology for
efficient charging, controls and monitoring purpose. Driven by powerful ARM processor, it works to protect
against connection error, prolonging battery life with its battery monitoring feature and communicates to
provide human interaction. RS485 data port is available for external monitoring via PMX II Software and can
be readily linked up to LAN through iPX5500 Com Box.

Features
Constant DC voltage charging for 24V battery bank
RS485 data port
4A initial charging current with reducing rate over charging time Rear View:
Built in surge protection + - + -
RS485
+A -B
REMINDER WARNING
AC 220 - 240V

Output short circuit protection


PLEASE READ THE ABOVE INSTRUCTIONS
50/60Hz RISK OF ELECTRICAL SHOCK
BEFORE OPERATING THIS UNIT TO DO NOT OPEN
PREVENT RISK OF FIRE AND DAMAGE THIS UNIT MUST BE EARTHED
FUSE : 5A BACK UP BATT IN another quality product from
DC OUT
BATTERY INPUTS REVERSED amperes electronics
POLARITY WARNING

Thermal protection against overheating


Auto low battery disconnection with LCD indication 24V DC from batteries
Battery reversed polarity protection Back up output terminal

Rear mains switch to avoid unnecessarily switching off the unit


RS485 communication for remote monitoring via PMX LAN software

Technical Specifications Application Schematics


Operating voltage 220 - 240V AC
Charging voltage 27.8V DC
Charging current 4A; (max 5A) BC9740
Idle power consumption 1.3W
Protections Low battery auto disconnection, reverse polarity, short
circuit
Indications AC mains, short circuit and low battery
Displays Charging current Amperes PS9400
Charging voltage 24V DC 24V power supply
Battery Bank
Battery voltage
Output current bypass for
heavy load
Battery reverse polarity
Communication RS485 out; link to Amperes PMX LAN via Optional : To Equipment with
Required when 24V Operating
iPX5500 comm. box for remote monitoring
providing back up Voltage
E/M back up Amp rating 25A max to heavy loads
( Use external contactor / relay if required )
Terminals Battery input , EM load Contactor ( 24V DC Coil ) To heavy load equipment. ie.
Power Amplifiers
Dimensions (W x H x D) 482 x 44 x 180 mm
Weight 4.50 kg

Packing information
Carton size : 555 (L) x 295 (W) x 95 (H) mm
Gross weight : 5.20 kg
1 unit per carton

www.ampereselectronics.com scan for


updates
Page 48
Dual Cone Ceiling Speakers SPEAKERS

CS210 / 510 / 610 are general purpose speakers suitable for paging and BGM applications which not only deliver the
2” 6W 100V CS210
required audio quality but also fits into every installation with its contemporary outlooks. It is designed with slim edges 5” 6W 100V CS510
for cozy appearance and the clamping mechanism that provides ease of installation works.
6” 6W 100V CS610
Three variants are available with re-engineered sound output to serve the needs for both BGM and EVAC. CS210 is
a miniature version most suitable for small enclosed area such as hotel room foyer and narrow corridors, while CS510
6” 10W 100V CS610B
and 610 fits most other installations according to the needs of different coverage areas.

CS610 CS510 CS210

Features Slim edge design with low side profile Packing information
CS210 : 570(L) x 230(W) x 290(H) mm
High quality ABS enclosure : 11.30 kg
: 20 uts per carton
Spring clip for ease of installations
Option for installation without enclosure CS510 : 690(L) x 350(W) x 400(H) mm
: 19.60 kg
Fire retardant ( FR ) grade materials available as an option : 24 uts per carton

CS610 : 660(L) x 440(W) x 430(H) mm


: 19.50 kg
: 18 uts per carton

Technical Specifications
CS210 CS510 CS610 CS610B
SPEAKER
Power rating 6W 100V line 10W 100V line
Diameter 2” (51 mm) 5” (125 mm) 6” (150 mm)
Cone type Single cone Dual cone
Impedance (Ohm) 8
Freq response @ 1kHz +/-3 dB 160 - 15 kHz 150 - 19 kHz 120 - 19 kHz
SPL @ 1W / m (+/- 3dB) 1 kHz) 90 dB 92 dB
Dispersion angle ( 1 kHz +/- 3 dB ) 120 160 165 165

TRANSFORMER
Tapping (100V line) 1.5 / 3 / 6W 1 / 3 / 6 / 10W
Primary impedance (Ohm) 6.7k / 3.3k / 1.67k 10K / 3.3k / 1.67k / 1k
Secondary impedance (Ohm) 8

PHYSICAL
Grille / enclosure Metal powder epoxy coated / ABS enclosure
Cutting hole dim 85 mm 145 mm 185 mm
Overall size (dia x height) 110 x 110 mm 165 x 110 mm 205 x 110 mm
Weight 500 g 780 g 840 g 850 g
Colour White

scan for www.ampereselectronics.com


updates
Page 53
SPEAKERS Surface Mount Speakers
BS508 5” 10W 100V Vandal Proof
BS506 5” 6W 100V
BS410 4” 10W 100V
DV410 4” 6W 100V

BS508 5” 10W 100V


It is powered by 5” dual cone driver with nominal power of 10W 100V line, available
power taps are 1,3,6 and 10W. It is slimmer for better looks and has installation
DV410 4” 6W 100V method which prevents vandalism.
DV410 is a favorite for its classic outlooks, suitable for small area installations such as
staircases, offices and can be mounted vertical or horizontally. It is driven by 4” driver of Suitable for various wall installations with optimum delivery for both BGM and
6W 100V with power taps of 1,3 and 6W. EVAC systems

Packing information Packing information


Carton : 460 (L) x 420 (W) x 410 (H) mm Carton : 460 (L) x 460 (W) x 320 (H) mm
Gross weight : 16.70 kg Gross weight : 22.25 kg
20 units per carton 24 units per carton

BS506 5” 6W 100V BS410 - 4” 10W 100V


BS506 is driven by 5” dual cone driver with power taps of 1,3,6W 100V. The enclosure is Available in white and is suitable for installations in small areas, staircases, etc. It
fully ABS thus eliminating the risk of rust for high humidity environment. Suitable for is driven by 4” dual cone driver with power taps of 1,3,6 and 10W 100V, providing
installations at walkways, staircases etc. clarity of voice announcements as required in EVAC systems.

Packing information Packing information


Carton : 550 (L) x 400 (W) x 180 (H) mm Carton : 460 (L) x 420 (W) x 410 (H) mm
Gross weight : 10 kg Gross weight : 16.70 kg
12 units per carton 20 units per carton

Technical Specifications
BS508 BS506 BS410 DV410
SPEAKER
Power rating 10W 100V 6W 100V 10W 100V 6W 100V
Diameter 5” 4”
Cone type Dual cone
Impedance (Ohm) 8
Freq response @1kHz +/- 3dB 120 ~ 18 kHz 100 ~ 15 kHz 100 ~ 16 kHz 100 ~ 18 kHz
SPL @ 1W / m (+/- 3dB) 1 kHz 94 dB 93 dB 92 dB 90 dB

TRANSFORMER
Tapping (100V line) 1 / 3 / 6 / 10W 1 / 3 / 6W 1 / 3 / 6 / 10W 1 / 3 / 6W
Primary impedance (Ohm) 10 k / 3.3 k / 1.6 k /1 k 10k / 3.3k / 1.6 k 10k / 3.3 k / 1.6 k / 1k 10k / 3.3k / 1.6 k
Secondary impedance (Ohm) 8

PHYSICAL
Grille / enclosure Metal / ABS ABS Plastic Metal / ABS
Overall size (W x H x D) 220 x 130 x 70 mm 172 x 195 x 105 mm 185 x 215 x 90 mm 195 x 215 x 105 mm
Weight 720 g 780 g 760 g 740 g
Colour White

www.ampereselectronics.com scan for


updates
Page 56
ACCESSORIES / COMPLEMENTARY PRODUCTS

Back Enclosures Rack Panels Patch Panels

Back enclosures with 50 mm depth for volume Amperes harmonious mounting ears blank and vent XLR patch panel for rack and wall mount.
controllers and patch panels. Available in ABS and panels with black powder epoxy coating.
metal for concealed or surface mounting
EC7012 : 70 X 120 mm conceal (steel) BP1000 : 1 hu blank panel MR5000 : 5 Way rack mount female XLR

ES7012 : 70 x 120 mm surface mounting (steel) BP2000 : 2 hu blank panel MR1000 : 10 Way rack mount female XLR

EA9090 : 86 x 86 mm conceal mounting (ABS) VP1000 : 1 hu ventilation panel MP1000 : Single inlet female XLR panel

ES9090 : 86 x 86 mm surface (steel) VP2000 : 2 hu ventilation panel MP2000 : Double inlet female XLR panel

SLA Batteries Fiber Optic Converter


SLA battery bank for back up supply. Recommended battery
charger is Amperes BC9740.

VT 1226 26 Ah
VT 1240 40 Ah
VT 1265 65 Ah
VT 12100 100 Ah

Power Supply Surge Arrestor

Regulated power adaptor and switching PSU for Suitable for surge protection of external speaker installations. Single mode / multimode Ethernet - Fiber convert-
powering loose equipments Protects horn speakers against harmful surge. er of IP paging applications. Available in 2 core and
single core transceiver

PS1205 : 12V 0.5A AC / DC adaptor HP 175VL : 175V peak surge arrestor HTB110 : Multimode with SC/ST connectors

PS2405 : 24V 0.5A AC / DC adaptor HTB110S : Single mode with SC connectors

PS9000 : 24V 4.5A DC switching power module HTB114S : Single mode with 4 way switch

HTBGS-03 : Single mode 10 / 100 / 1000 Base T