Connexion au MSAN

- Interface de ligne de commande CLI

* Mode de configuration port série

* Mode de configuration Telnet


• Outband
• Inband
Mode de configuration Port Série
•Démarrer L’ hyper terminal
SCU
Serial port
CON
RS-232 serial ETH
port cable
PC ESC

MA5600T

Hyper
Start All Programs Accessories Communication Terminal
Hypertrm.exe
Bit per Second :9600
Data Bit:8
Parity: None
Stop Bit:1
Flow Control: None
Mode de Configuration Telnet
SCU
Ethernet cable
Outband LAN CON
PC ETH
ESC

MA5600T

SCU GICF

Inband IP 0/19/0
0/9/0 0/19/0
0/9/1
PC 0/9/2 0/20/0
0/9/3 0/20/1

MA5600T
Login au Système

• Le système a un compte d’utilisateur par défaut

– Username: root
– Password: admin
Modes de ligne de commande

BTV mode
MA5600T(BTV)#

BTV quit

User mode enable Privilege mode config Global config mode


MA5600T> MA5600T# MA5600T(config)#
quit disable quit

interface... quit

return
Port/Interface mode
MA5600T(config-if-...)#
Command Line Parameter Meaning
Character Meaning

<K> Keyword

<U> ULONG. Information following it is the range of the value to be


entered

<L> LONG. Information following it is the range of the value to be entered.

<S> Character string. Information following it is the length of the


character string to be entered.

<I> IP address

<M> MASK, such as the mask of an IP address.

<PA> MAC address

<H> Hexadecimal number. The system supports the input of "0x".

<D> <yyyy-mm-dd> Date

<T> <hh:mm:ss> Time

<Cr> Enter. It means the end of the command.


MA5600T(config)#interface
{ adsl<K>|atm<K>|csp<K>|edt<K>|emu<K>|epon<K>|epon
nni<K>|eth<K>|giu<K>|gpon<K>|gponnni<K>|loopback<
K>|meth<K>|mgcp<K>|null<K>|opf<K>|opg<K>|scu<K>|
shl<K>|topstm1<K>|top<K>|tunnel<K>|vdsl<K>|vlanif<K
>|vrgw<K> }:

Intelligent matching

* MA5600T>ena [space]
* MA5600T>enable
* Display History Commands

MA5600T(config)#display history-command

--------------------------------------------------
No. Command
--------------------------------------------------
10 terminal
9 smart
8 interactive
7 interface
6 config
5 en
4 interface
3 quit
2 interface
1 interactive
Command Syntax and Format
Format Description

Boldface The keywords of a command are in boldface.

[] Items in square brackets [ ] are optional.

{ x | y | ... } Alternative items are grouped in braces and separated by


vertical bars. One is selected.

[ x | y | ... ] Alternative items that are optional are grouped in square


brackets and separated by vertical bars. One or none is selected.

{ x | y | ... } Alternative items are grouped in braces and separated by


* vertical bars. A minimum of one or a maximum of all can be
selected.

[ x | y | ... ] Optional alternative items are grouped in square brackets and


* separated by vertical bars. Multiple or none is selected.
CLI Error Prompts

Error Message Cause

Unknown command The entered command or keyword is not


found, the parameter type is incorrect or the
parameter value exceeds the threshold.

Incomplete command The entered command is incomplete.

Too many parameters You have entered too many parameters.

Ambiguous command The entered command is ambiguous.


User Account Management

User Profile and User


User A
All these users can login to
User Profile 1 User B the MA5600T from 8:00AM
to 5:00PM, and the user
User C account validity is three
months.

User G
All these users can login to
User Profile 2 the MA5600T from 10:00AM
User H to 3:00 PM, and the user
account validity is one month.
User K
User Authorities

Authority level Function

Common user Only query the basic settings of the MA5600T

Operator Configure the MA5600T and some services


Manage all the functions and services of the MA5600T,
Administrator
and can manage all the lower level users
The highest authority, manage all the functions and
Super User
services and for managing all the lower level users
Query all the user profiles

MA5600T(config)#display terminal user-profile

{all | online | name username}:all

------------------------------------------------
User profile name : root
Validity period of the user name :0
Validity period of the password :0
Permitted start time of logon by a user : 00:00
Permitted end time of logon by a user : 00:00
--------------------------------------------------
Add a new user

MA5600T(config)#terminal user name


User profile name(<=15 chars)[root]:
User Name(<=15 chars): huawei
User Password(<=15 chars):
Confirm Password(<=15 chars):
User's Level:
1. Common User 2. Operator 3. Administrator:3

Permitted Reenter Number(0--4):4

This user has been added

Repeat this operation? (y/n)[n]:


Modify the user password

MA5600T(config)#terminal user password

User name (<=15 chars):huawei

New password(<=15 chars):

Confirm Password(<=15 chars):

Information takes effect Repeat this operation?


(y/n)[n]: n
Delete the user

MA5600T(config)#undo terminal

{debugging<K>| hold<K>| monitor<K> user<K>|}:user

{name<K>}:name

Are you sure to delete the user?(y/n)[n]:


Hardware Operation

* Board Management
Query all the boards in the frame
MA5600T(config)#display board 0
----------------------------------------------------
SlotID BoardName Status SubType0 SubType1 Online/Offline
------------------------------------------------------
0
1 H801OPFA Normal
2 H801OPFA Normal
3
4 H801OPFA Failed Online
5
... ...
8
9 H801SCUN Standby_normal
10 H801SCUN Active_normal
Add a board
MA5600T(config)#board add

{ frameid/slotid<S><1,15> }:0/4
{ ADI<K>|ADK<K>|ADL<K>|ADP<K>|ADQ<K>|ASP<K>|H
801AIUG<K>|H801ASRB<K>|H801BIUA<K>|H801CITA<K
>|H801CITD<K>|H801CSPA<K>|H801EDTB<K>|H801EPB
A<K>|H801ETHA<K>|H801ETHB<K>|H801GICF<K>|H801
GICG<K>|H801GICK<K>|H801GPBC<K>|H801OPFA<K>|
H801PRTA<K>|H801PRTE<K>|H801PRTG<K>|H801SPUA
<K>|H801SPUB<K>|H801TOPA<K>|H801VRGA<K>|H801
X1CA<K>|H801X2CA<K>|…..}: H801OPFA
Confirm a board
MA5600T(config)#board confirm
{frameid[/slotid]<S><1,15>}: 0/4
Reset board
MA5600T(config)#board reset
{ frameid/slotid<S><1,15> }:0/3
Command: board reset 0/3 Are you sure to
reset board? (y/n)[n]:y
0 frame 3 slot reset board message sent
successfully...

Board Prohibit
MA5600T(config)#board prohibit
{ frameid/slotid<S><1,15> }:0/3
Command: board prohibit 0/3
Prohibiting board will interrupt all services on this
board, are you sure to prohibit board? (y/n)[n]:y
Board Status

Main Active-Normal
Control
Standby-Normal
Board
1 The board can be automatically
Auto_find found after inserted into the slot but
not registered in the system
Config (transition
2 Confirm the board, the status
Service status) becomes normal, the config status is
a transitional status
Board
Normal

3 Faults happen, the status becomes


Failed failed
Alarm Management
Alarm Management in MA5600T

NMS
MA5600T
Output switch
SRAM
1000 fault
alarms and
fault clear
messages
Description of Common Alarm Attributes

1 - Alarm ID

huawei(config)#display alarm list all


------------------------------------------------
ALARM_ID
0x02310000
0x02310001
0x02310002
0x02320000
0x02320001
0x02320002
2 - Alarm serial number

huawei(config)#display alarm history alarmclass fault 1 1 list


------------------------------------------------------------------------------------
AlarmSN Date&Time Alarm Name/Para
------------------------------------------------------------------------------------
79 2009-03-29 12:19:05 The upstream port fails
FrameID: 0, SlotID: 20, PortID: 1
------------------------------------------------------------------------------------
3 - Alarm level
• Critical alarm: Global alarms
– Impair the normal equipment operation and should be repaired
immediately.
– Power supply circuit faults and loss of clock reference.
• Major alarm: Local board or line alarms
– Lead to abnormal service operation if not handled in time.
– Fibre broken or physical line fault.
• Minor alarm: Generic state fault alarms and event alarms.
– Describe whether the boards or lines operate normally.
– Bit errors on a physical line.
• Warning alarm: State changes and events
– No influence on the system performance and user services designed to
inform the operator of a change in state.
– Prompt information on recovery of equipment to normal state.
4 - Alarm class 5 - Alarm type

• Communication
• Service
. Fault alarm
• Process
. Recovery alarm • Equipment
• Environment
Alarm Management Contents

• Querying an alarm record

• Querying the alarm configuration

• Querying the basic alarm information

• Setting the alarm level

• Setting alarm output to CLI terminal


• To query the alarm record according to the alarm ID:

huawei(config)#display alarm history alarmid 0x02310000 1 1 list


---------------------------------------------------------------------------------------
AlarmSN Date&Time Alarm Name/Para
---------------------------------------------------------------------------------------
60 2009-03-29 07:43:03 The communication between the
service board and the control
board fails FrameID: 0, SlotID: 20,
Board name:H801X2CA
---------------------------------------------------------------------------------------
* To query alarms of a certain class:

huawei(config)#display alarm history alarmclass fault 1 1 detail


ALARM 7658 FAULT WARNING 0x2e313024 EQUIPMENT 2011-02-23 16:03:23
ALARM NAME : The loss of carrier signals occurs on the LAN port of the ONT
PARAMETERS : FrameID: 0, SlotID: 1, PortID: 0, ONT ID: 3, Ethernet PortID: 4
DESCRIPTION : The loss of carrier signals occurs on the LAN port of the ONT
and the related service is interrupted
CAUSE : A loss of signal occurs on the Ethernet port
ADVICE : Ensure that the network cable is inserted into the
corresponding Ethernet port of the ONT and the network cable
does not loosen
--- END
* Setting Alarm Level
• EXAMPLE: To set the alarm level with the alarm ID of 0x02310000 as minor,
do as follows:

huawei(config)#display alarm configuration 0x02310000

---------------------------------------------------------------------------
ALARMID: 0x02310000, NAME: The communication between
the service board and the control board fails
CLASS: FAULT, TYPE: EQUIPMENT Each kind of alarm has default
LEVEL: MAJOR, DEFAULT LEVEL: MAJOR alarm level and current alarm
PARA NUMBER: 5 level.
CLI_OUTPUT FLAG: YES
CONVERSION FLAG: This alarm hasn't been converted
DESCRIPTION: The communication between the service board and the control
board is interrupted. In this case, all the services in the service board fail

huawei(config)#alarm alarmlevel 0x02310000 minor


* Setting Alarm Output to CLI Terminal

• To output the alarm with ID of 0x02310000 to the CLI terminal:

 huawei(config)#alarm output alarmid 0x02310000

• To output all alarms with the level of major to the CLI terminal:

 huawei(config)#alarm output alarmlevel major

• To output alarms with the type of equipment to the CLI terminal:

 huawei(config)#alarm output alarmtype equipment

• To output an alarm in detail to the CLI terminal:

 huawei(config)#alarm output detail on