Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

PX01X XXX XXX Axxx en

Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

OPERATOR’S MANUAL

PX01X-XXX-XXX-AXXX
INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED: 3-7-13
(REV. B)

1/4" DIAPHRAGM PUMP


1:1 RATIO (NON-METALLIC)
READ THIS MANUAL CAREFULLY BEFORE INSTALLING,
OPERATING OR SERVICING THIS EQUIPMENT.
It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.

PUMP DATA
Models. . . . . . . see Model Description Chart on page 2 for
“-XXX” options
Pump Type. . . Non-Metallic Air Operated Double Diaphragm
Material. . . . . . see Model Description Chart
Weight. . . . . . . Polypropylene. . . . . . . . 2.86 lbs (1.30 kgs)
PVDF. . . . . . . . . . . . . . . . . 3.88 lbs (1.76 kgs)
Acetal. . . . . . . . . . . . . . . . 3.52 lbs (1.60 kgs)
Maximum Air Inlet Pressure. . . . . . . . 125 psig (8.6 bar)
Minimum Air Inlet Pressure. . . . . . . . . 10 psig (0.69 bar)
Maximum Outlet Pressure. . . . . . . . . . 125 psig (8.6 bar)
Maximum Flow Rate. . . . . . . . . . . . . . . . 5.3 gpm (20 lpm)
Maximum Material Inlet Pressure. . . . 10 psig (0.69 bar)
Displacement / Cycle @ 125 p.s.i.g. . 0.019 gal / 0.072 ltrs
Maximum Particle Size . . . . . . . . . . . . . 1/16” dia.(1.6 mm)
Maximum Temperature Limits (diaphragm / ball / seat Model PD01X
material)
Acetal . . . . . . . . . . . . . . . . . . . . 10° to 180° F (-12° to 82° C)
E.P.R. / EPDM. . . . . . . . . . . . . . -60° to 280° F (-51° to 138° C)
Kynar® PVDF. . . . . . . . . . . . . . 10° to 200° F (-12° to 93° C)
Hytrel® . . . . . . . . . . . . . . . . . . . -20° to 150° F (-29° to 66° C)
Neoprene . . . . . . . . . . . . . . . . 0° to 200° F (-18° to 93° C)
Nitrile® . . . . . . . . . . . . . . . . . . . 10° to 180° F (-12° to 82° C)
Polypropylene. . . . . . . . . . . . 35° to 175° F (2° to 79° C)
Viton®. . . . . . . . . . . . . . . . . . . . -40° to 350° F (-40° to 177° C)
Santoprene®. . . . . . . . . . . . . . -40° to 225° F (-40° to 107° C)
PTFE. . . . . . . . . . . . . . . . . . . . . . 40° to 225° F (4° to 107° C)
Dimensional Data. . . . . . . . . . . . . . . . . . . see page 10
Noise Level @ 70 p.s.i., 60 c.p.m.. . . . . . 62.3 db(A)

 The pump sound pressure levels published here have been updated to
an Equivalent Continuous Sound Level (LAeq) to meet the intent of ANSI
S1.13-2005, CAGI-PNEUROP S5.1.

Mounting Adapter Plate Optional Accessory Kit (24123879) available.


Please contact your nearest ARO / Ingersoll Rand customer service or
distributor for details.

Model PE01X

Figure 1

INGERSOLL RAND COMPANY LTD


209 NORTH MAIN STREET – BRYAN, OHIO 43506
 (800) 495-0276  FAX (800) 892-6276 © 2013 CCN 80448053
www.ingersollrandproducts.com
MODEL DESCRIPTION CHART
Model Code Explanation
Example: PX01 X - X X X - X X X - A X X X
Model Series
PD01- Standard Pump
PE01- Electronic Interface
Center Body Material
E- Groundable Polypropylene
F- Polypropylene with Leak Failure Detection
P - Polypropylene
Connection
H- Hybrid 1/4” NPT / BSP
Fluid Caps / Manifold Material
D- Groundable Acetal
K- Kynar PVDF
P- Polypropylene
Hardware Material
S- Stainless Steel
Seat / Spacer Material
D- Acetal
K- Kynar PVDF
P- Polypropylene
0- Polypropylene (Flex Check Spacer)
1- Acetal (Flex Check Spacer)
2- PVDF (Flex Check Spacer)
Check Material
A- Santropene
C- Hytrel
G- Nitrile
J- Nitrile (flex check only)
K- EPR (flex check only)
L- Viton (flex check only)
N- Neoprene (flex check only)
T- PTFE
Diaphragm / O-Ring Material
A- Santoprene
C- Hytrel
G- Nitrile
T- PTFE
Revision
A- Revision
Specialty Code 1 (Blank if no Speciality Code)
A- Solenoid 120VAC,110VAC AND 60VDC
B- Solenoid 12VDC, 24VAC and 22VAC
C- Solenoid 240VAC, 220VAC AND 120VDC
D- Solenoid 24VDC, 48VAC and 44VAC
G- Solenoid 12VDC ATEX Zone 1
H- Solenoid 24VDC ATEX Zone 1
K- Solenoid 220VAC ATEX Zone 1
N- Solenoid with no Coil
0- Standard Valve Block ( No Solenoid)
Specialty Code 2 (Blank if no Speciality Code)

E- End of stroke feedback / cycle sensing (with M12 Circular Connector) + Leak Detection
F- End of stroke feedback / cycle sensing ( with M12 Circular Connector)
L- Leak Detection
N- End of stroke feedback / cycle sensing (no Connector) + Leak Detection
P- End of stroke feedback (No Connector)
0- No option
Special Testing
For Special Testing options, please contact your nearest Ingersoll Rand Customer Service Representative or Distributor.

NOTICE: All possible options are shown in the chart, however, certain combinations may not be recommended.
Consult a representative or the factory if you have questions concerning availability.

Page 2 of 12 PX01X-XXX-XXX-AXXX (en)


OPERATING AND SAFETY PRECAUTIONS
READ, UNDERSTAND, AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.

EXCESSIVE AIR PRESSURE HAZARDOUS MATERIALS


yy Obtain Material Safety Data Sheets on all materials
S TATIC SPARK HAZARDOUS PRESSURE from the supplier for proper handling instructions.
CAUTION Verify the chemical compatibility of the
pump wetted parts and the substance being pumped,
WARNING EXCESSIVE AIR PRESSURE. Can cause per- flushed or recirculated. Chemical compatibility may
sonal injury, pump damage or property damage. change with temperature and concentration of the
yy Do not exceed the maximum inlet air pressure as chemical(s) within the substances being pumped,
stated on the pump model plate. flushed or circulated. For specific fluid compatibility,
yy Be sure material hoses and other components are able consult the chemical manufacturer.
to withstand fluid pressures developed by this pump. CAUTION Maximum temperatures are based
Check all hoses for damage or wear. Be certain dispens- on mechanical stress only. Certain chemicals will
ing device is clean and in proper working condition. significantly reduce maximum safe operating
WARNING STATIC SPARK. Can cause explosion temperature. Consult the chemical manufacturer for
resulting in severe injury or death. Ground pump and chemical compatibility and temperature limits. Refer
pumping system. to PUMP DATA on page 1 of this manual.
yy PX01X-HDS-XXX are Groundable Acetal pumps: Use CAUTION Be certain all operators of this equipment
the pump ground lug provided. Connect to a 12 ga.
(minimum) wire (kit 66885-1 is included) to a good have been trained for safe working practices,
earth ground source. understand it’s limitations, and wear safety goggles /
yy Sparks can ignite flammable material and vapors. equipment when required.
yy The pumping system and object being sprayed must be CAUTION Do not use the pump for the structural
grounded when it is pumping, flushing, recirculating or support of the piping system. Be certain the system
spraying flammable materials such as paints, solvents, components are properly supported to prevent stress
lacquers, etc. or used in a location where surrounding on the pump parts.
atmosphere is conducive to spontaneous combustion. yy Suction and discharge connections should be flex-
Ground the dispensing valve or device, containers, hos- ible connections (such as hose), not rigid piped,
es and any object to which material is being pumped. and should be compatible with the substance being
yy Secure pump, connections and all contact points to pumped.
avoid vibration and generation of contact or static spark.
yy Consult local building codes and electrical codes for CAUTION Prevent unnecessary damage to the
specific grounding requirements. pump. Do not allow pump to operate when out of
yy After grounding, periodically verify continuity of material for long periods of time.
electrical path to ground. Test with an ohmmeter yy Disconnect air line from pump when system sits idle
from each component (e.g., hoses, pump, clamps, for long periods of time.
container, spray gun, etc.) to ground to insure conti- CAUTION Use only genuine ARO® replacement parts to
nuity. Ohmmeter should show 0.1 ohms or less. assure compatible pressure rating and longest service life.
yy Submerse the outlet hose end, dispensing valve or NOTICE Install the pump in the vertical position. The
device in the material being dispensed if possible. pump may not prime properly if the balls do not check by
(Avoid free streaming of material being dispensed.) gravity upon start-up.
yy Use hoses incorporating a static wire. NOTICE RE-TORQUE ALL FASTENERS BEFORE
yy Use proper ventilation.
OPERATION. Creep of housing and gasket materials may
yy Keep inflammables away from heat, open flames and sparks.
yy Keep containers closed when not in use. cause fasteners to loosen. Re-torque all fasteners to insure
WARNING Pump exhaust may contain contaminants. against fluid or air leakage.
Can cause severe injury. Pipe exhaust away from work NOTICE Replacement warning labels are available
area and personnel. upon request: Static Spark” pn \ 93616-1, Diaphragm
yy In the event of a diaphragm rupture, material can be Rupture” pn \ 93122.
forced out of the air exhaust muffler.
yy Pipe the exhaust to a safe remote location when WARNING = Hazards or unsafe practices which
pumping hazardous or inflammable materials. could result in severe personal injury,
yy Use a grounded 1/4” minimum i.d. hose between the death or substantial property damage.
pump and the muffler. CAUTION = Hazards or unsafe practices which
WARNING HAZARDOUS PRESSURE. Can result in could result in minor personal injury,
serious injury or property damage. Do not service product or property damage.
or clean pump, hoses or dispensing valve while the = Important installation, operation or
system is pressurized. NOTICE
maintenance information.
yy Disconnect air supply line and relieve pressure from
the system by opening dispensing valve or device
and / or carefully and slowly loosening and removing
outlet hose or piping from pump.
WARNING HAZARDOUS MATERIALS. Can cause serious
injury or property damage. Do not attempt to return
a pump to the factory or service center that contains
hazardous material. Safe handling practices must
comply with local and national laws and safety code
requirements.
PX01X-XXX-XXX-AXXX (en) Page 3 of 12
GENERAL DESCRIPTION OPERATING INSTRUCTIONS
The ARO diaphragm pump offers high volume delivery even yy Always flush the pump with a solvent compatible with
at low air pressures, easy self priming and the ability to pump the material being pumped if the material being pumped
various viscosity materials. The pump is designed to corre- is subject to “setting up” when not in use for a period of
spond to the needs of the user by offering a variety of wetted time.
parts configurations to handle almost any application. yy Disconnect the air supply from the pump if it is to be in-
Air operated double diaphragm pumps utilize a pressure active for a few hours.
differential in the air chambers to alternately create suction yy The outlet material volume is governed not only by the
and positive fluid pressure in the fluid chambers. Flat checks air supply, but also by the material supply available at
insure a positive flow of fluid. the inlet. The material supply tubing should not be too
Pump cycling will begin as air pressure is applied and it will small or restrictive. Be sure not to use hose which might
continue to pump and keep up with the demand. It will build collapse.
and maintain line pressure and will stop cycling once maxi-
mum line pressure is reached (dispensing device closed) and MAINTENANCE
will resume pumping as needed.
The Acetal material used in this pump contains stainless steel yy This product is not intended to be repairable. However,
some service items are available.
fibers. It’s conductivity allows it to be connected to a suitable
ground. A ground screw is provided for this. yy Provide a clean work surface to protect sensitive internal
moving parts from contamination from dirt and foreign
matter during service disassembly and reassembly.
AIR AND LUBE REQUIREMENTS yy Keep good records of service activity and include the
WARNING EXCESSIVE AIR PRESSURE. Can cause pump pump in preventive maintenance program.
damage, personal injury or property damage. yy At the end of its service life, please dispose of pump and
yy A filter capable of filtering out particles larger than 50 contents properly.
microns should be used on the air supply. In most ap-
plications there is no lubrication required other than the
“O” ring lubricant which is applied during assembly or repair.
yy The pump, when fitted with flex checks, can be rotated
360° to suit the application. It may be mounted upside
down or on the wall with no effect on suction lift or op-
erating efficiency. The filter and regulator need to be ori-
ented in a normal vertical direction to function properly.
yy If lubricated air is present, make sure that it is compatible
with the “O” rings and seals in the air motor section of the
pump.

INSTALLATION
yy Apply PTFE tape or pipe sealant to threads upon assem-
bly to prevent leakage.
yy Secure the diaphragm pump legs to a suitable surface to
insure against damage by vibration.
yy When the diaphragm pump is used in a forced-feed
(flooded inlet) situation, it is recommended that a “Check
Valve” be installed at the air inlet.

 Kynar® is a registered trademark of the Arkema Inc.  Loctite® and 242 are registered trademarks of the Henkel Loctite Corporation 
 ARO® is a registered trademark of Ingersoll-Rand Company  Santoprene® is a registered trademark of Monsanto Company, licensed to Advanced Elastomer Systems, L.P. 
 Lubriplate® is a registered trademark of Lubriplate Division (Fiske Brothers Refining Company) 

Page 4 of 12 PX01X-XXX-XXX-AXXX (en)


PARTS LIST / PX01X-XXX-XXX-AXXX
COMMON PARTS MATERIAL CODE
PX01X-XXX-XXX-AXXX [B] = Nitrile
Item Description [Mtl] Qty Part no [Co] = Copper
[D] = Acetal
1 Rod Assembly (includes seals) --- [1] 24028284 [E] = E.P.R. / EPDM
[P] [2] 23981541 [G] = Nitrile
5 Washer, Diaphragm [GP] = Groundable Polypropylene
77 Plate --- [2] 93264 [H] = Hytrel
[K] = Kynar PVDF
206 Caution Label --- [1] 93122 [N] = Neoprene
[P] = Polypropylene
207 Warning Label --- [1] 93616-1 [Sp] = Santoprene
[SS] = Stainless Steel
26 Screw [SS] [32] 23981574 [T] = PTFE
[U] = Polyurethane
[V] = Viton

FLUID CONNECTION
PX01X-XXX-XXX-AXXX
PX01X-HDS PX01X-HKS PX01X-HPS
Item Description Part no [Mtl] Qty Part no [Mtl] Qty Part no [Mtl] Qty
6 Diaphragm Screw 93810-2 [D] (2) 93810-3 [K] (2) 93810-1 [P] (2)
15 Fluid Cap 23981640 [D] (2) 23981657 [K] (2) 23981632 [P] (2)
60 Inlet Manifold 23981681 [D] (1) 23981699 [K] (1) 23981673 [P] (1)
61 Outlet Manifold 23981723 [D] (1) 23981731 [K] (1) 23981715 [P] (1)
43 Ground Lug 93004 [Co] (1) --- ---

SEAT OPTIONS BALL / FLEX CHECK OPTIONS


PX01X-XXX-XXX-AXXX PX01X-XXX-XXX-AXXX
“21” “22” (5/8” o.d) "42”
-XXX Seat Qty [Mtl] -XXX Ball Qty [Mtl] -XXX FLEX CHECK Qty [Mtl]
-DXX 96580-2 (4) [D] -XAX 96481-A (4) [Sp] -XJX 96744-2 (4) [B]
-KXX 96580-3 (4) [K] -XCX 96481-C (4) [H] -XNX 96744-3 (4) [N]
-PXX 96580-1 (4) [P] -XGX 96481-G (4) [B] -XLX 96744-4 (4) [V]
-HPS-0XX 96745 (4) [P] -XTX 96481-4 (4) [T] -XKX 96744-1 (4) [E]
-HKS-2XX 96745-1 (4) [K]
-HDS-1XX 96745-2 (4) [D]

DIAPHRAGM OPTIONS PX01X-XXX-XXX-AXXX


"7" "19" "64"

-XXX Diaphragm Qty Mtl Seal Qty Mtl "O" Ring Qty Mtl
-XXA 93808 (2) [Sp] 93761 (4) [E] ----- --- ---
-XXC 93808-C (2) [H] Y325-119 (4) [B] ----- --- ---
-XXG 93808-G (2) [B] Y325-119 (4) [B] ----- --- ---
-XXT 93898 (2) [T] 96514 (4) [T] 93947 --- [B]
Note: Item (19) O-ring is not used with Flex Check Options.

PX01X-XXX-XXX-AXXX (en) Page 5 of 12


PX01X-XXX-XXX-AXXX / FLUID SECTION

26 
77
42 (for flex check models, 4 places)

43
64 (PTFE models only)

6
101
21
26 

7
19
22
61

60
26 
21

1
5
64
15

7
6 

 TORQUE REQUIREMENTS 
26

NOTE: DO NOT OVERTIGHTEN FASTENERS.


 (26) Screws 51-55 in. lbs (5.8 - 6.2 Nm).
 (6) Diaphragm Screw / Washer 60-70 in. lbs (6.8 - 9.7 Nm).

LUBRICATION / SEALANTS
 Apply Lubriplate FML-2 grease (94276) to all “O” rings, “U”
cups and mating parts.
 Apply Loctite® 242® to threads.

Page 6 of 12 PX01X-XXX-XXX-AXXX (en)


PARTS LIST / PX01X-XXX-XXX-AXXX

AIR SECTION PARTS


Item Description Part no Qty [Mtl] Item Description Part no [Mtl]
Qty
101 Center Body 403 Valve (AII PE01X with SoIenoid) 114102 (1)
(PD01X) 23981392 (1) [P]
(All PE01X without Diaphragm 413 Coil Nut (All PE01X with Solenoid) 119380 (1)
Failure Detection) 23981392 (1) [P]
(PE01X With Diaphragm Failure 414 Coil ,120 VAC
Detection) 23981608 (1) [P] 116218-33 (1)
(PE01X-XXX-XXX-XAXXX)
(PD01E and PE01E)
(not available with Diaphragm Failure 24243354 (1) [GP] Coil ,24 VAC , 12VDC
116218-38 (1)
Detection) (PE01X-XXX-XXX-XBXXX)
107 Valve Block Plug Coil ,240 VAC
116218-35 (1)
(PE01X-XXX-XXX-XCXXX)
(PD01X, PE01X-XXX-XXX-X0XXX) 23981434 (1) [P] Coil ,48 VAC, 24VDC
116218-39 (1)
(PE01X-XXX-XXX-XDXXX)
(All PE01X with Solenoid) 23981848 (1) [P]
Coil, ATEX, 12VDC
(PE01X-XXX-XXX-XGXXX)
117345-38 (1)
111 Major Valve Spool Asm
(includes seals) Coil, ATEX, 24VDC
(PE01X-XXX-XXX-XHXXX)
117345-39 (1)
(PD01X, PE01X-XXX-XXX-X0XX) 24028268 (1) [D] Coil, ATEX, 220VAC
(PE01X-XXX-XXX-XKXXX)
117345-35 (1)
(All PE01X with Solenold) 24086779 (1) [D]
415 O-Ring (AII PE01X with Solenoid) 114103 (1) [B]
129 Muffler Baffle
416 O-Ring (AII PE01X with Solenoid) 114104 (1) [B]
(PD01X, PE01X-XXX-XXX-XX0XX) 23981475 (1) [P]
417 Screw (AII PE01X with Solenoid) 96728647 (2)
(PE01X-XXX-XXX-XXNXX) 24110926 (1) [P]
418 Tube (AII PE01X with Solenoid) 15309974 (1) [SS]
(PE01X-XXX-XXX-XXPXX) 24110926 (1) [P]
419 Seal (AII PE01X with Solenoid) 96957 (1) [B]
(PE01X-XXX-XXX-XXEXX) 24110934 (1) [P]
420 Snap Ring (AII PE01X with Solenoid) Y147-43 (1)
(PE01X-XXX-XXX-XXFXX) 24110934 (1) [P]
421 Retainer (AII PE01X with Solenoid) 96954 (1) [B]
(PE01X-XXX-XXX-XXLXX) 23981475 (1) [P]
429 Solenoid Muffler
(AII PE01X with Solenoid)
116464 (1)
132 Gasket 23981525 (1) [B]
\
135 Valve Block Assembly

(PD01X, PE01X-XXX-XXX-X0XXX) 24243388 (1) [P]

(All PE01X with Solenoid) 24340275 (1) [P]

137 O-Ring (0.070 CS x 0.676 ID) Y-325-17 (1) [B]

167 Pilot Valve Spool Assembly 24028276


(includes seals)
(1) [D]

173 O-Ring 24243313 (1) [U]

283 Diaphragm
Failure Detector
(PE01X-XXX-XXX-XXEXX) 96270-1 (2)

(PE01X-XXX-XXX-XXLXX) 96270-1 (2)

(PE01X-XXX-XXX-XXNXX) 96270-1 (2)

PX01X-XXX-XXX-AXXX (en) Page 7 of 12


PX01X-XXX-XXX-AXXX / AIR SECTION
PD01X-XXX-XXX-AXXX - Air Section
167  3
26  1

129

101

107

137  3 173
132 

111  3

26 1

135

PE01X-XXX-XXX-AXXX- Air Section

429 283
167  3

26 1
413 129
414

417
101
403

416 173

415 107

418
137 420
421
419  3 132  3

111 3

26  1  TORQUE REQUIREMENTS 
NOTE: DO NOT OVERTIGHTEN FASTENERS.
 (26) Screws 25-28 in.lbs (2.8 - 3.2 Nm)

LUBRICATION / SEALANTS
135  Apply Lubriplate FML-2 grease (94276) to all “O” rings,
“U” cups and mating parts.
 Apply Loctite® 242® to threads.

Page 8 of 12 PX01X-XXX-XXX-AXXX (en)


PE01X OPTION WIRING DIAGRAMS
End of Stroke / Cycle Sensor Pinout, M12 Connector

PIN 1 1 CABLE ASSEMBLY WIRING COLORS:


PIN 2
2 PIN 1 - BROWN, POSITIVE VOLTAGE (+10 TO +30 VDC)
PIN 2 - WHITE, NOT USED
PIN 3 - BLUE, ZERO VOLTS
4 PIN 4 - BLACK, SIGNAL
PIN 3 PIN 4 3 NOTE: WIRING COLORS ARE BASED ON
AUTOMATION DIRECT CD12L AND CD12M 4-POLE
CABLE ASSEMBLIES.

End of Stroke / Cycle Sensor Pinout Wiring Diagram (No Connector)

PNP Output

1 BROWN L +10 TO +30 VDC


4 BLACK
Load 200 mA MAX
L- 0 VDC
3 BLUE

Diaphragm Failure Detector Wiring Diagram

TURCK (PICOFAST) CONNECTOR


PSW 3M -*/S90

A BN PIN A

LOAD
+
C 40 mA
SCHEMATIC

MAX
SENSOR

BLK PIN C 24.0 + 10%


V.D.C

B
BU PIN B
-

SCHEMATIC

PINOUT FUNCTION
A + 24 VDC
B 0 VDC
C SIGNAL

Page 9 of 12 PX01X-XXX-XXX-AXXX (en)


DIMENSIONAL DATA
Dimensions shown are for reference only, they are displayed in inches and millimeters (mm).

P*

A C

N*
D

E * Dimensions N & P are for models PE01X only.


Dotted lines show options for PE01X pumps.

“R” Material Outlet (External THD.)


“S” Material Outlet (Internal THD.)

F L M

H “T” Material Inlet


(Internal THD.)
G
K

“Q” Air Inlet


“U” Material Inlet
(External THD.)

DIMENSIONS

A - 7.2” (182 mm) H- 1.9” (48.6 mm) Q - 1/4 - 18 PTF SAE Short
B - 3.9” (100.0 mm) J - 2.4” (61 mm) R- 3/4-14 NPTF
C - 4.6” (117.0 mm) K - 3.9” (99 mm) S - 1/4 NPTF / BSPT Hybrid
D- 6.8” (173.0 mm) L - 2.1” (53 mm) T - 1/4 NPTF / BSPT Hybrid
E- 0.3” (8.8 mm) M - 3.2” (81 mm) U- 3/4-14 NPTF
F- 6.1 ” (156 mm) N - 7.2” (184 mm) V- 1/4 NPTF
G- 0.8” (20.7 mm) P - 5.6” (142.2 mm)

PX01X-XXX-XXX-AXXX (en) Page 10 of 12


Page 11 of 12 PX01X-XXX-XXX-AXXX (en)
Page 12 of 12 PX01X-XXX-XXX-AXXX (en)

You might also like