Installation Instructions

TB/TI
Thermistor Insertion Temperature Sensor

Important: Retain these instructions

These instructions shall be used by trained service


personnel only. If the equipment is used in a manner not
specified by these instructions, the protection provided by the
equipment may be impaired. https://partners.trendcontrols.com

Contents
1 Box Contents..................................................................1 3 Cleaning and Maintenance............................................7
2 Installation......................................................................1 4 Disposal..........................................................................8

1 Box Contents

TB/TI Thermistor Insertion


Temperature Sensor Installation
Instructions (TG200727)

2 Installation

Dimensions 57 mm (2.24”)
1 /L 400 mm (15.75”)
/S 150 mm (5.91”)
85 mm (3.35”)
6 mm (0.24”)

105 mm (4.13”)

Pockets for use as immersion sensor; Brass (WB150) Stainless Steel (WS150)
135 mm (5.31”)
Ø6.5 mm (0.25”)
14 mm (0.53”)

Ø8 mm 24 mm
(0.31”) (0.95”)

143 mm (5.63”) R½” (BSPT)

Mounting flange for use as duct sensor (ACC/DF) Universal Fitting Kit for immersion sensor
use in existing pockets (ACC/UF)

clip
50 mm
(1.97”)

hexagonal
socket 2 mm
grub screw
6 mm compression
fitting
3 x 4 mm diam. holes
on a 30 mm (1.18”) PCD spring
(Pitch Circle Diameter) brass brush

TB/TI Thermistor Insertion Temperature Sensor Installation Instructions TG200727 Issue 4, 10-Aug-2015.1
TB/TI Installation Instructions

2 InSTallaTIon (continued)

Requirements
2
measurement range

-30 °C to +110 °C 0 %RH 95 %RH


(-22 °F) (+230 °F)

H2 O

Protection :IP67 (NEMA6)

Immersion Immersion

-40 °C to +50 °C
(-40 °F) (+122 °F)

-40 °C to +110 °C Cl2


(-40 °F) (+230 °F)

Note that WS150 or WB150 are NOT suitable


for use in chlorine rich environments

Immersion Immersion

Ensure no stratification
(e.g. downstream of mixing
valves, junctions)

(minimum distance from junctions =10xd).

Duct Duct

-40 °C to +50 °C
(-40 °F) (+122 °F)

-40 °C to +110 °C
(-40 °F) (+230 °F)
Ensure no stratification (e.g. downstream of mixing
dampers, heating coils, cooling coils) otherwise
use averaging sensor.

2 TB/TI Thermistor Insertion Temperature Sensor Installation Instructions TG200727 Issue 4, 10-Aug-2015.
Installation Instructions TB/TI

2 InSTallaTIon (continued)

Install Immersion Sensor


3
InSTall PoCKeT (if installing new pocket)
apply sealent
Drill hole for boss Fix threaded boss *Screw pocket into boss to boss thread

½” BSPT threaded boss use M24 Spanner

InSTall SenSoR InTo PoCKeT (If using compatible pocket)


Either; (if using new pocket) Or; (if using old pocket with grub screws)

tighten screws

spring compression fitting use 2 mm hexagonal socket key

InSTall SenSoR InTo PoCKeT (If using Universal Fitting Kit)


Push adaptor onto probe Adjust probe length if pocket has clip retaining groove,
push clip over pocket

tighten

clip clip engages in groove

spring pocket
length
probe is forced against
end of pocket
brass brush use 2 mm hexagonal
socket key
*Mount in pocket if pocket has grub screw,
discard spring and clip

tighten screw
over bush

probe is forced against


end of pocket

*If used for chilled water ensure pocket is sealed around probe
or fill pocket with thermally conducting oil to avoid the build up
of condensation in bottom of pocket.

TB/TI Thermistor Insertion Temperature Sensor Installation Instructions TG200727 Issue 4, 10-Aug-2015. 3
TB/TI Installation Instructions

2 InSTallaTIon (continued)

Install Duct Sensor


4
EITHER: DIRECT MOUNT SENSOR ON DUCT
Drill hole in duct Drill 2 pilot holes

2 off No 6 3/4” s/s


Ø 7 mm self tapping screws
(0.28”)
42.5 mm 2 off
(1.67”) integral foam gasket

85 mm (3.35”)

OR: USE COMPRESSION FITTING


SEPARATE COMPRESSION FITTING
Loosen nut Unscrew fitting compression fitting

duct mounting flange

EITHER: (FOR THICKER MATERIAL) USE COMPRESSION FITTING ONLY


tap hole screw in fitting

drill and tap 1/8” BSPT

>6 mm

OR: (FOR THINNER MATERIAL) USE COMPLETE MOUNTING FLANGE


drill 3 holes screw on flange mounted flange

3 off pilot
holes

30 mm (1.18”)
3 off No 6 3/4” s/s self tapping screws
<6 mm

ADJUST DEPTH OF PROBE


Either; Or;

4 TB/TI Thermistor Insertion Temperature Sensor Installation Instructions TG200727 Issue 4, 10-Aug-2015.
Installation Instructions TB/TI

2 Installation 
(continued)

Remove Lid
5

Insert Cable
6
Either: use M20 flexible conduit Or: use M16 cable gland

Wire to Controller
7 terminal size 0.5 to 2.5 mm2 (20 to 14 AWG)

TP/1/1/22/HP/200-600V (Belden 8761) cable recommended

Sensor IQ controller

COM (0V) Analogue input


channel configured
IN for thermistor (T)
polarity
independent

terminate screen at IQ end only

Replace Lid
8 Note: that IP67 (NEMA6) rating is only achieved if the sensor is
correctly installed with cable or conduit connection fully tightened.

TB/TI Thermistor Insertion Temperature Sensor Installation Instructions TG200727 Issue 4, 10-Aug-2015.5
TB/TI Installation Instructions

2 Installation 
(continued)

Configure controller
9
IQ

or
IQ
IQ Configuration Manual (90-1533)
IQ3 Configuration Manual (TE200768)
IQ4 Configuration Manual (TE201263)
IQeco Configuration Manual (TE201089)

Set up IQ Sensor Type


10
It is recommended to use SET for the setting of the sensor Thermistor (-30 °C to +110 °C, -22 °F to +230 °F)
type module. For all IQ2 series controllers with firmware
version 2.1 or greater, or IQ3/4 series controllers, the following Units: °C °F
SET Unique Sensor References should be used: Y Input type 1 (therm V)
E Exponent 3
Thermistor: Thermistor TBTI (-30 °C to +110 °C) U Upper 115 239
Thermistor TBTI F (-22 °F to +230 °F)
L Lower -35 -31
Alternatively set scaling mode to 5 (characterise) and enter P Points 20
scaling manually as defined in the adjacent table. x Ix Ox
1 0.480 110 230
Note that for IQ3/4, scaling mode and exponent do not need 2 0.549 105 220
to be set up. 3 0.630 100 212
4 0.724 95 203
For all other IQ controllers see Sensor Scaling Reference
5 0.833 90 194
Card (TB100521A).
6 0.961 85 185
7 1.110 80 176
8 1.484 70 158
9 1.985 60 140
10 2.641 50 122
11 3.470 40 104
12 4.460 30 86
13 6.663 10 50
14 7.668 0 32
15 8.102 -5 23
16 8.482 -10 14
17 8.807 -15 5
18 9.078 -20 -4
19 9.299 -25 -13
20 9.476 -30 -22

Test System
11

IQ
∆T

6 TB/TI Thermistor Insertion Temperature Sensor Installation Instructions TG200727 Issue 4, 10-Aug-2015.
Installation Instructions TB/TI

3 Cleaning and Maintenance


There are no serviceable parts inside the unit. Cleaning of the
unit should be carried out in order to avoid buildup of dust or
other containments. Disconnect power before carrying out any
cleaning.

TB/TI Thermistor Insertion Temperature Sensor Installation Instructions TG200727 Issue 4, 10-Aug-2015.7
TB/TI Installation Instructions

4 Disposal

WEEE Directive:
At the end of their useful life the packaging and
product should be disposed of by a suitable
recycling centre.
Do not dispose of with normal household waste.
Do not burn.

Please send any comments about this or any other Trend technical
publication to techpubs@trendcontrols.com
 TR CU Certification
© 2015 Honeywell Technologies Sàrl, ECC Division. All rights reserved. Manufactured for and on behalf of the Environmental and Combustion Controls
Division of Honeywell Technologies Sàrl, Z.A. La Pièce, 16, 1180 Rolle, Switzerland by its Authorized Representative, Trend Control Systems Limited.

Trend Control Systems Limited reserves the right to revise this publication from time to time and make changes to the content hereof without obligation
to notify any person of such revisions or changes.
Trend Control Systems Limited
Albery House, Springfield Road, Horsham, West Sussex, RH12 2PQ, UK. Tel:+44 (0)1403 211888 Fax:+44 (0)1403 241608 www.trendcontrols.com

8 TB/TI Thermistor Insertion Temperature Sensor Installation Instructions TG200727 Issue 4, 10-Aug-2015.

You might also like