Polytron 2 XP Tox Pi 9044328 en
Polytron 2 XP Tox Pi 9044328 en
Polytron 2 XP Tox Pi 9044328 en
ST-1413-2006
offers a variety of diagnostics and self test features.
TECHNICAL DATA
90 44 328 | 06.10-1 | Marketing Communications | GM | PR | Printed in Germany | Chlorine-free – environmentally compatible | Subject to modifications | © 2010 Dräger Safety AG & Co. KGaA
Type Explosion proof transmitter
Gases and Ranges Toxic gases and oxygen in user selectable ranges (see sensor data sheet)
Display Backlit LCD; 2 lines, 20 characters Menu structure and messages in real text
Signal Output Analog Normal operation 4 to 20 mA
Warning, configurable fault signal every 10 s for 1 s, or off; user programmable
Maintenance 4 ± 1 mA 1 Hz modulation, or steady; user programmable
Fault < 1.2 mA
Digital HART®, RS 485
Relays (optional) Two alarm relays, one fault relay SPDT; user programmable
Rating: 5A 230 VAC, 5A 30 VDC
Supply Voltage 10 to 32 VDC, 3-wire
Ambient Conditions Temperature – 40 to + 150 °F / – 40 to + 65 °C
Pressure 20.7 to 38.4 inch Hg / 700 to 1300 mbar
Humidity 0 to 100 %RH (see sensor data sheet)
Enclosure NEMA 4X & 7, IP 66; 3/4" NPT female conduit entry
Size (h x w x d, approx.) 10 3/4" x 5" x 5" / 275 x 130 x 130 mm
Weight (approx.) 5.3 lbs / 2.4 kg
Approvals UL, CSA Class I, Div 1, Group B, C, D
ATEX II 2G EEx d [ia] IIC T6/T4, II 3D IP66 T85°C; – 40 ≤ Tamb ≤ + 40 / + 65 °C
CE-mark electromagnetic compatibility (directive 89/336/EEC)
HART® is registered trademark of HCF, Austin, TX
ORDER INFORMATION
Dräger Polytron 2 XP Tox without sensor and relays; UL, CSA, ATEX version 45 43 070
Dräger Polytron 2 XP Tox without sensor, with relays; UL, CSA, ATEX version 45 43 200
HEADQUARTERS:
Dräger Safety AG & Co. KGaA
Revalstrasse 1
23560 Lübeck, Germany
www.draeger.com