Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Basic Instruments

Download as pdf or txt
Download as pdf or txt
You are on page 1of 31

Basic Instruments

Safely Test High-Power Devices

January 2023 – March 2023

CATALOG
Table of Contents

3 Spotlight
4 Featured Products
5 Signal Generators
6 Signal Analyzers
7 Oscilloscopes
10 Data Acquisition / Switch Units
13 DC Power Supplies
18 Source Measure Units
19 Electric Loads
20 Waveform Generators
21 Digital Multimeters
24 Vector Network Analyzers
25 Keysight Streamline Series / USB Instruments
26 PathWave BenchVue Software
27 Special Offers
30 KeysightCare

Basic Instruments | 2
SPOTLIGHT

Safely Test High-Power Devices


Power and characterize up to 800 W safely and easily with our new auto-ranging benchtop power supply.

The Keysight E36150 Series autoranging benchtop power supply features two models with 800 W power on a single channel
output. These power supplies provide up to 60 V and 80 A to give you plenty of usable power to meet your testing needs.

The E36150 Series new power supplies also provide advanced characterization and power simulation capabilities.
These include voltage and current meter, data logging, scope view, and an arbitrary waveform generator (AWG).
Feature-packed to deliver high performance, the E36150 Series provides a one-box solution that eliminates the
demand of having to meet the requirements of multiple instruments.

The E36150 Series power supplies are designed for versatility and are perfect for various applications, including R&D,
design validation, reliability, and quality testing across all types of industries. The solution features an autoranging
architecture and peak power handling capabilities enabling you to meet your various test requirements with plenty of
usable power and flexibility.

Reducing cabling complexity


• Enables easy access to power outputs to connect and disconnect the device under test (DUT) quickly
and safely with its front-panel, high-current detachable binding post.
• Withstands maximum current output of 80 A while being fully compliant with the International
Electrotechnical Commission (IEC) 61010 safety requirements.

Advanced power control and analysis


(Keysight PathWave BenchVue BV9200B / BV9201B)
• Advanced tools for data logging, oscilloscope, arbitrary waveform generator (AWG), and complementary
cumulative distribution function (CCDF) statistical analysis — no additional programming required.
• Convenient access with a familiar PC control interface using the compatible PathWave BenchVue BV29200 /
BV9201B software.

Peak power-handling capabilities


• Power up to safely test your electromechanical or high-
capacitance devices that require a quick surge of power.
• Accommodate power surges of up to three times its
800 W rated output, delivering a total of 2400 W for
at least seven milliseconds.

WATCH SPOTLIGHT VIDEO

LEARN MORE ABOUT E36150 SERIES

Basic Instruments | 3
FEATURED PRODUCTS

Smart Bench Essentials


4 instruments; 1 connected interface

EDU36311A DC power supply EDUX1052G oscilloscope


90 W, triple output, and 50 MHz, 2 analog channels,
programmable for and 1 GSa/s sample rate for
clean, reliable power accurate capture and analysis

Keysight PathWave BenchVue software


Integrated, smart software
to test, analyze, and share
results remotely

EDU34450A 5.5-digit multimeter EDU33211A/EDU33212A function generators


Measures 11 input signals at 17 arbitrary waveforms and
up to 110 readings/s 6 built-in modulations to get you
for speed-critical tests set up and testing quickly

BenchVue instrument application PW9111EDU lab manager PW9112EDU remote learning


- instrument set up and test - lab configuration - lab scheduling and resource booking
- data logging and screen capture - asset tracking - remote access and authentication
- data export to several file types - mass firmware update - browser-based lab work

KeysightCare 24/7 Technical Support


Expert Technical Support IN ADDITION TO YOUR THREE-YEAR WARRANTY, YOU WILL RECEIVE THREE YEARS OF
KEYSIGHTCARE TECHNICAL SUPPORT ON ALL BASIC INSTRUMENTS IN THIS CATALOG.

Basic Instruments | 4
SIGNAL GENERATORS

X-Series Signal Generators


The Keysight X-Series creates signals capable of testing your very best devices. From the pure and precise MXG to the
cost-effective EXG and general-purpose CXG, the X-Series helps you generate true performance.

MXG-Analog EXG-Analog CXG-Analog

Model number N5181B N5171B N5166B

Frequency range 9 kHz to 6 GHz 9 kHz to 6 GHz 9 kHz to 6 GHz

Maximum output power +24 dBm +21 dBm +18 dBm

Frequency switching (list mode) 800 µs 800 µs 5 ms

Level accuracy ±0.6 dB ±0.6 dB ±0.6 dB

SSB phase noise (1 GHz, 20 kHz offset) -146 dBc/Hz -122 dBc/Hz -119 dBc/Hz

Harmonics (at 1 GHz) -35 dBc -35 dBc -35 dBc

AM, FM, PM, and pulse AM, FM, PM, and pulse AM, FM, PM, and pulse
Analog modulation
modulation modulation modulation

Digital modulation N/A N/A 120 MHz bandwidth

DATA SHEET DATA SHEET DATA SHEET

Get a Quote > Get a Quote > Get a Quote >

Basic Instruments | 5
SIGNAL ANALYZERS

Basic Spectrum Analyzers (BSAs)*


The BSAs define value-priced general-purpose instruments up to 20 GHz. You can rely on the BSA for proven testing
efficiency, usability, and the flexibility to adapt to new requirements.

Model N9320B N9321C N9322C N9323C N9324C

Frequency 9 kHz to 3 GHz 9 kHz to 4 GHz 9 kHz to 7 GHz 1 MHz to 13.6 GHz 1 MHz to 20 GHz

Overall amplitude accuracy ±0.5 dB ±0.6 dB ±0.6 dB ±0.7 dB ±0.7 dB

DANL at 1 GHz -145 dBm -152 dBm -152 dBm -144 dBm -144 dBm

Maximum analysis bandwidth 1 MHz 1 MHz 1 MHz 1 MHz 1 MHz

Phase Noise at 1 GHz -90 dBc / Hz -90 dBc / Hz -90 dBc / Hz -92 dBc / Hz -92 dBc / Hz

DATA SHEET DATA SHEET DATA SHEET DATA SHEET DATA SHEET

Get a Quote > Get a Quote > Get a Quote > Get a Quote > Get a Quote >

* From selected distributors only

Basic Instruments | 6
OSCILLOSCOPES
SOFTWARE INCLUDED

InfiniiVision Oscilloscopes
• Experience up to 1,000,000 waveforms / second update rate.
• Get MegaZoom IV and measure with uncompromised, responsive smart memory.
• Test using multiple instrument functionality.
• Expand your platform with upgradable bandwidth, a mixed-signal oscilloscope (MSO), serial analysis, and a built-in
waveform function generator.

Get more functionality with available software packages

Aerospace & Ultimate


Automobile Embedded Power USB
Defense Bundle

1000X Standard (DSOX) NA Standard NA NA NA

2000X D2000AUTB NA D2000GENB NA NA D2000BDLB

3000X D3000AUTB D3000AERB D3000GENB D3000PWRB D3000USBB D3000BDLB

4000X D4000AUTB D4000AERB D4000GENB D4000PWRB D4000USBB D4000BDLB

6000X D6000AUTB D6000AERB D6000GENB D6000PWRB D6000USBB D6000BDLB

SAVE 40% OFF QUALIFYING INFINIIVISION SOFTWARE FOR A LIMITED TIME! SEE THE SPECIAL OFFERS SECTION AT THE END OF THIS
CATALOG TO LEARN MORE.

Basic Instruments | 7
Model 1000 X-Series 2000 X-Series 3000G X-Series 4000 X-Series 6000 X-Series Infiniium EXR-Series

Professional- Entry-level Advanced Everything the Dive deeper Simplify data


level capabilities with more capabilities 3000G has and analyze gathering and
in an entry-level capabilities simplified plus see more more signal analysis
oscilloscope of your signal detail

• Serial bus • Advanced • 25% lower


• Protocol options math • Higher • Voice noise than
analysis • Mixed-signal • Standard bandwidth control S-Series
Description • Bode plots oscilloscope embedded • Larger touch • Advanced • New Fault
• Fast Fourier options software** screen jitter Hunter
transform • Waveform • Up to four analysis, feature
(FFT) and active time interval • Multiscope
measurement probes error plots, application
histograms** histograms,
and eye
diagrams

50 MHz to 70 MHz to 100 MHz to 200 MHz to 1 GHz to 500 MHz to


Bandwidth
200 MHz 200 MHz 1 GHz 1.5 GHz 6 GHz 2.5 GHz

Channels
(analog + 2, 4 2, 2+8, 4, 4+8 2, 2+16, 4, 4+16 4, 4+16, 8, 8+16
digital)

Sample rate Up to 2 GSa/s Up to 5 GSa/s Up to 20 GSa/s Up to 16 GSa/s

Up to 1
Up to 2 Mpts
Mpts and
Memory and segmented
segmented Up to 4 Mpts and segmented memory standard Up to 3.2 Gpts
depth memory
memory
standard
standard

Waveform >200,000 >200,000 >450,000 >200,000


>1,000,000 wfms/s
update rate wfms/s wfms/s wfms/s wfms/s

12.1-inch
8.5-inch 12.1-inch 15.6-inch
capacitive
Display 7-inch 8.5-inch capacitive capacitive capacitive
multi-touch
touch screen touch screen touchscreen
screen

20-MHz function Dual 20-MHz Dual 20-MHz


20-MHz 20-MHz AWG,
generator, AWG, 5-digit AWG, 10-digit 10-digit
function 8-digit counter,
Built-in 5-digit counter, counter, and counter, and counter, DVM,
generator, frequency
instruments frequency frequency frequency and protocol
5-digit response
response response response analyzers
counter* analyzer*
analyzer* analyzer* analyzer*

DATA SHEET DATA SHEET DATA SHEET DATA SHEET DATA SHEET DATA SHEET

Get a Quote > Get a Quote > Get a Quote > Get a Quote > Get a Quote > Get a Quote >

* All X-Series models have a built-in protocol analyzer and 3-digit digital voltmeter (DVM)

** Only standard on the 3000G X-Series models

Basic Instruments | 8
Featured Resource

5 Mistakes People Make When


Getting a Low-Cost Scope
Choosing the right oscilloscope is a difficult task, especially if you’re on a budget. You want to make the best decision for
your needs while saving money and maintaining quality.

Avoid five common mistakes people make when selecting a low-cost oscilloscope so you — and your wallet — are happy
with your decision.

DOWNLOAD THE WHITE PAPER

Basic Instruments | 9
DATA ACQUISITION / SWITCH UNITS
SOFTWARE INCLUDED

DAQ970A and DAQ973A Data


Acquisition System
Get the next-generation Keysight data acquisition (DAQ) system with a three-slot mainframe and your choice of nine
plug-in modules. Interface with the DAQ using BenchVue DAQ software, the intuitive graphical front panel with task-
oriented, self-guiding menus, or a web browser.

• Features an advanced 6.5-digit internal


DMM with improved accuracy and faster
measurement speed (50,000 readings /
second) to sample more signals.
• Measures very low current ranges (1 μA DC
and 100 μA AC) and higher resistance range
(1,000 MΩ).
• Compensates using new auto-calibration
for internal drifts caused by time and
temperature changes.
• Comes with additional GPIB for the
DAQ973A; easy connectivity to your PC
with LAN and USB.
• Code compatible with Keysight
34970A / 34972A.
• Each module updated with improved
switching speeds and accuracies.
• Fast Keysight DAQM900A solid-state
multiplexer with scan rate speed of up
to 450 channels / second.
• New Keysight DAQM909A 4-channel
simultaneous sampling digitizer
module with a sampling rate of up to
800 kSa / second.

DATA SHEET

Get a Quote >

Basic Instruments | 10
DAQ970A/73A
Description Key specifications
Modules

DAQM900A 20-channel solid-state multiplexer Up to 450 ch/s Get a Quote >

20-channel multiplexer plus 2 Armature 2 / 4 wire, 80 ch/s with DAQ970A/


DAQM901A Get a Quote >
current channels DAQ973A, up to 300 V, 1 A

DAQM902A 16-channel multiplexer Reed 2 / 4 wire, 250 ch/s, up to 300 V, 50 mA Get a Quote >

DAQM903A 20-channel actuator / GP switch SPDT / Form C, 120 ch/s, up to 300 V, 1 A Get a Quote >

DAQM904A 4 x 8 matrix Armature 2-wire, 120 ch/s, up to 300 V, 1 A Get a Quote >

Common low (not terminated), 60 ch/s up to


DAQM905A 2 GHz, dual 4-channel, RF mux, 50Ω Get a Quote >
42 V, 0.7 A

• Two 8-bit digital I/O ports, up to 42 V,


400 mA
DAQM907A Multifunction module • 26-bit 100 kHz event counter, up to 42 V Get a Quote >
• Two 16-bit analog outputs, up to ±12 V,
10 mA

Common low (without 4-wire measurements)


DAQM908A 40-channel single-ended multiplexer Get a Quote >
60 ch/s, up to 300 V, 1 A

Differential inputs, up to 800 kSa/s sampling


DAQM909A 4-channel simultaneous sampling digitizer Get a Quote >
rate, 24-bit resolution

Basic Instruments | 11
Featured Resource

4 Considerations for
Data Acquisition Systems
There is a growing trend across all industries to design feature-rich products. However, you know that the more features
added, the more complex the test development becomes.

Explore four considerations for a DAQ that will help you develop a test system optimized for speed and accuracy.

DOWNLOAD THE EBOOK

Basic Instruments | 12
DC POWER SUPPLIES
SOFTWARE INCLUDED

N6700 Modular Power System


N6700: DC power supply — ideal for automated test systems.

• Small 1U mainframe (400, 600, 1200 W) holds up to four output modules.


• Over 35 programmable DC modules offer unique capabilities, performance, voltage, and current combinations.
• Multiple DC electronic load modules, 100 and 200 W, allow current to be sourced and sinked in the same mainframe.

N6705C: DC power analyzer — deep insight without a complex test system.

• Holds and uses up to four N6700 Series modules (600 W total).


• Integrates digital multimeter (DMM), oscilloscope, arb, and data logger capabilities.
• Characterizes and improves battery run time with a source / measure unit (SMU) and BV9200B analysis software.

N6700C, N6701C, & N6702C


N6705C DATA SHEET
DATA SHEET

Get a Quote > Get a Quote >

Basic Instruments | 13
E36300 Series Triple-Output SOFTWARE INCLUDED

DC Power Supplies
• large display with voltages and currents for all three outputs
• accurate programming / readback as low as 0.03%
• low output ripple and noise less than 2 mVpp / 350 uVrms
• precise data logging plus output sequencing and coupling
• convenient front and rear output terminals
• color-coded outputs and individual knobs for voltage and current
• LAN (LXI Core), USB, and GPIB (optional)

Model E36311A E36312A E36313A

Economy model Most popular Twice the current

Power 80 W 80 W 160 W

Channels 1 2 3 1 2 3 1 2 3

0 to 6 V 0 to +25 V 0 to -25 V 0 to 6 V 0 to 25 V 0 to 25 V 0 to 6 V 0 to 25 V 0 to 25 V
DC output
Rating (0 to 40 °C)
0 to 5 A 0 to 1 A 0 to 1 A 0 to 5 A 0 to 1 A 0 to 1 A 0 to 10 A 0 to 2 A 0 to 2 A

Get a Quote > Get a Quote > Get a Quote >

DATA SHEET

Basic Instruments | 14
E36200 Series DC Power Supplies
• single or dual outputs; easily combine the dual outputs into a single output with 400 W
• auto-parallel the Keysight E36233A 400 W autoranging dual output power supply to create a single
40 A (30 V) output
• auto-series the E36233A to create a single 120 V (10A) output
• programming / readback accuracy as low as 0.03%
• output ripple and noise < 350 μVrms
• data logging plus output sequencing and coupling
• front and rear output terminals
• color-coded outputs and individual knobs for voltage and current
• LAN, USB, and GPIB (optional)

Model E36231A E36232A E36233A E36234A

Power 200 W 200 W 400 W 400 W

Channels 1 1 1 2 1 2

DC output
0 to 30 V 0 to 20 A 0 to 60 V 0 to 10 A 0 to 30 V 0 to 20 A 0 to 60 V 0 to 10 A
Rating (0 to 40 °C)

Get a Quote > Get a Quote > Get a Quote > Get a Quote >

DATA SHEET

Basic Instruments | 15
E36150 Series Autoranging
Benchtop Power Supplies
• Peak power that handles up to three times the maximum power rating to accommodate start-up power surge
requirements from electromechanical and high capacitance devices under test
• High performance with precise output accuracy, minimal noise, and excellent load / line regulation
• Adjustable slew rate, data logging, voltage and current meter, four-wire remote sensing, LIST output programming,
and digital controls
• Comprehensive overvoltage, overcurrent, and overtemperature provide device protection
• Flexible Keysight BV0003B PathWave BenchVue power supply application and test flow automation support
• Inclusive Keysight BV9200B / BV9201B PathWave BenchVue advanced power control and analysis software assistance
• Scalable and upgradable with Keysight Option E36150ADVU for scope view and arbitrary waveform generator (AWG)
functions that offer advanced characterization and power simulation
• Adaptable LAN / LXI, USB, and general purpose interface bus (GPIB) (upgrade option) interfaces

Model E36154A E36155A

Output 1

Power 800 W

Voltage 0 to 30 V 0 to 60 V

Current 0 to 80 A 0 to 40 A

Get a Quote > Get a Quote >

DATA SHEET

Basic Instruments | 16
Featured Resource

4 Ways to Build Your Power


Supply Skills
Today’s designs place higher demands on the systems that power them. You may find that more of your design problems
are created by these power systems.

Use these four practical tips to ensure you deliver reliable power during the design phase and get the most out of your
power supply.

DOWNLOAD THE EBOOK

Basic Instruments | 17
SOURCE MEASURE UNITS
SOFTWARE INCLUDED

B2900 Series Precision


Source Measure Units (SMUs)
B2900B/BL Series precision SMUs B2960B/BL Series low-noise power source

• minimum source resolution at 10 fA / 100 nV; • 6.5 digit 2-channel, wide and bipolar voltage / current
sourcing (100 nV - 210 V / 10 fA - 10.5 A, 31.8 W)
• minimum measurement resolution at 10 fA / 100 nV
• noise performance at 10 µVrms, 1nVrms / √Hz with
• maximum output at 210 V, 3.03 A DC
external filter
• waveform generation (arbitrary) and digitizing
• precision arbitrary waveform capability with support
capabilities from 10 μs interval
for seven built-in functions and user-defined
• integrated 4-quadrant source and measurement waveforms (1 MHz – 10 kHz)
capabilities
• 4.3-inch color display supports both graphical and
• 4.3-inch color display supports graphical and numerical view modes
numerical view modes
• application software to facilitate PC-based instrument
• application software to facilitate PC-based instrument control (free)
control (free)
• high throughput and SCPI command supporting
• high throughput and SCPI command supporting conventional SMU command set
conventional SMU command set

B2900B DATA SHEET

B2960B DATA SHEET

Get a Quote >

Basic Instruments | 18
ELECTRIC LOADS

EL30000 Series Bench DC


Electronic Loads
The Keysight EL30000 Series bench DC electronic loads provide superior performance in a compact bench form factor.

• Test up to 600 W, 1 or 2 inputs.


• Operate in constant current (CC), constant voltage (CV), constant resistance (CR), or constant power (CP) modes.
• Make accurate measurements with excellent programming / feedback accuracy.
• Perform static and dynamic tests.
• View measurements on a 4.3-inch LCD color display.
• Transfer data via USB drive, LAN, USB, or GPIB.

Model Number of inputs Input power DC Input voltage DC Input current

EL34143A 1 350 W 150 V 60 A Get a Quote >

60 A per input,
EL34243A 2 600 W 150 V Get a Quote >
120 A parallel

Need more power?


See the Keysight E36200
Series 200 and 400 W
autoranging power supplies.

DATA SHEET
ELECTRONIC LOAD
FUNDAMENTALS WHITE PAPER

Basic Instruments | 19
WAVEFORM GENERATORS
SOFTWARE INCLUDED

33500B and 33600A Series


Trueform Waveform Generators
• Generate Trueform arbitrary waveforms with high fidelity and less jitter and harmonic distortion.
• Access ease-of-use features, such as modulation, sweep, burst, dual-channel coupling, and IQ baseband
signal player.

Arbitrary waveforms
Frequency
Model Description Channels Pulse Sample Memory/
range Std/Opt arb # Bits
rate Channel

33509B 1
Optional
33510B 2
160
20 MHz 20 MHz
MSa/s
33511B 1
Standard 1M
33512B Exclusive Trueform waveform 2
Standard,
technology with < 40 ps jitter 16
16 M
33519B and < 0.04% THD. 1
Optional Optional
35520B 2
250
30 MHz 30 MHz
MSa/s
33521B 1
Standard
33522B 2

33611A 1 660
Exclusive Trueform waveform 80 MHz 80 MHz 4M
33612A 2 MSa/s
technology at higher Standard,
Standard 14
frequency ranges with < 1 ps 64 M
33621A jitter < 0.03% THD. 1 120 100
1 GSa/s Optional
33622A 2 MHz MHz

DATA SHEET

Get a Quote >

Basic Instruments | 20
DIGITAL MULTIMETERS
SOFTWARE INCLUDED

Truevolt Digital Multimeters


• 6.5- and 7.5-digit performance
• graphical capabilities such as trend and histogram charts
• measure very low current, 1 µA range with pA resolution, enabling measurements on very low power devices
• auto-calibration to compensate for temperature drift
• basic measurements such as DCV, ACV, DCI, ACI, 2- and 4-wire resistance, frequency, period, continuity, diode,
temperature, and capacitance

Digits of Max reading rate at Built-in PC


Model Description
resolution 4½ digits (RDGS/S) interfaces

USB; optional
34460A 300
Display DMM results in histogram, bar, and trend charts GPIB, LAN
on color graphical display for easy monitoring and to 6.5
speed up statistical analysis USB, LAN;
34461A 1,000
optional GPIB

34465A Comes with a digitizer and advanced triggering capability 6.5


USB, LAN;
so you can make more measurements with higher speed, 50,000
optional GPIB
34470A better accuracy, and more memory 7.5

DATA SHEET

Get a Quote >

Basic Instruments | 21
3458A Digital Multimeter, 8.5-Digit
• Get 8.5-digit resolution with 0.1 ppm transfer accuracy.
• Perform accurate measurements with 8 ppm (0.0008%) DCV accuracy (4 ppm optional).
• Experience a maximum reading rate of 100,000 readings / second.
• Execute measurements that include DC and AC voltage, DC and AC current.
• Measure using 2- and 4-wire resistance, frequency, and period.
• Use the 148K reading memory for prolonged data logging (now comes standard).
• RoHs compliant.

DATA SHEET

Get a Quote >

Basic Instruments | 22
Featured Resource

Solving for Common Low Resistance


Measurement Accuracy Issues
A 4-wire measurement method is the most accurate method to measure small resistances, especially in ranges below
100 ohms. The 4-wire method eliminates measurement errors that long leads and switches introduce in your test setups.
The method is also very useful when you need to monitor for accurate and precise temperature changes. This solution
brief will compare the differences between making a 2-wire and a 4-wire resistance measurement.

DOWNLOAD THE SOLUTION BRIEF

Basic Instruments | 23
VECTOR NET WORK ANALYZERS
SOFTWARE INCLUDED

E5063A ENA Vector Network Analyzer*


• frequency options to suit your test needs and budget, upgradable at any time
• PCB manufacturing test capability with Option 011
• support for six languages via softkey and the embedded help manual in English / Simplified Chinese
• support all Keysight calibration kits, including the Keysight N755xA economy ECal module

ENA Series E5063A

Frequency 100 kHz to 500 M, 1.5, 3, 4.5, 6.5, 8.5, 14 or 18 GHz

Test port 2-port 50 Ω S-parameter test set

Dynamic range 117 dB (spec.), 122 dB (typ.)

Trace noise 0.005 dBrms (spec.), 0.015 dBrms (typ.)

Source power –20 to 0 dBm

Fixture simulator, Time domain analysis/Test Wizard option 1,


Key software capability
Wireless power transfer analysis 1, and Materials measurement 2

Interface LAN, USB (front 2, rear 4), USBTMC, GPIB 1, Handler I/O 1

1. Optional capability.
2. External software; Keysight N1500A Material Measurement Suite required.

* From selected distributors only

DATA SHEET

Get a Quote >

Basic Instruments | 24
KEYSIGHT STREAMLINE SERIES /
USB INSTRUMENTS

Vector Network
Analyzers and
Oscilloscopes
• multiple new compact, faceless, USB instruments
• common technology and measurement capabilities as benchtop
and modular instruments
• perfect for component and subassembly test, R&D labs, and light
manufacturing
• small footprint in size, weight, and power
• ideal for a rack at 1U high

Vector Network Analyzer (VNA)* Oscilloscope

P9370A/B, P9371A/B, P9372A/B, P9373A/B,


Models P9241A, P9242A, P9243A
P9374A/B P9375A/B, P9377B, P9382B, P9384B

300 kHz to 26.5 GHz (P937xA)


Bandwidth 9 kHz to 20 GHz (P937xB/P938xB) 200 MHz, 500 MHz, and 1 GHz
100 kHz to 44 GHz (P937xB)

Capabilities • Full 2-port (P937xA/B) and 4-port (P938xB) VNA • 2 analog channels
• Ability to extend the number of ports • 5 GSa/s
• Same calibration and metrology as all trusted • 1,000,000 wfms/s
Keysight VNAs • Zone triggering
• 6-in-1 instrument: arbitrary waveform generator,
frequency response analyzer, digital voltmeter,
counter, protocol analyzer

P397XA DATA SHEET P93XXB DATA SHEET DATA SHEET

Get a Quote > Get a Quote >

* From selected distributors only

Basic Instruments | 25
PATHWAVE BENCHVUE SOFT WARE

Instrument Control
Software Applications
• Use to connect instruments, record results quickly,
TECHNICAL OVERVIEW
and visualize measurements.
• Save time with automated test sequences.
Get a Quote >
• Analyze and export data in multiple formats.

Control Multiple Instruments Analyze and Export Data

Drag-and-drop your way to connect instruments, record results, Get easy access to extensive data, screen captures, trace,
and visualize measurements across multiple instruments and measurement logging capabilities. Export your data in
simultaneously, without the need for programming. multiple formats in just a few clicks.

Access Integrated Apps Instrument Compatibility

Choose from a wide array of apps with powerful features • data acquisition units, digital multimeters, and
to simplify your test workflow — from measurement setup electronic loads
and automation to exporting data and analyzing in-depth • FieldFox handheld analyzers, function generators, and
results — in one software application. The applications USB modular products
support hundreds of Keysight instruments and are
• universal counters, oscilloscopes, and photovoltaic
continually expanding. array simulators
• power analyzers, power meters and power sensors,
Automate Test Sequences and power supplies
• signal generators, spectrum analyzers, and network
Rapidly build custom test sequences with an intuitive analyzers
interface to quickly create tests that previously required
days of traditional programming. The integrated Test Flow
application makes it simple to drag and drop controls or
measurements into a sequence for rapid test development.

Basic Instruments | 26
SPECIAL OFFERS

Save 25% on InfiniiVision Oscilloscopes


Save 25% on InfiniiVision oscilloscope application bundles! These
power, automotive, and jitter pre-configured bundles are available LEARN MORE
on the InfiniiVision 3000G, 4000, and 6000 X-Series oscilloscopes.

Bundle option Discount Automotive Power Jitter

DSO3054GAUT DSO3054GPWR DSOX6004JIT

• DSOX3054G: 4-channel, • DSOX3054G: 4-channel, • DSOX6004A: 4-channel,


500-MHz oscilloscope with 500-MHz oscilloscope with 1-GHz oscilloscope
embedded analysis software embedded analysis software • D6000BDLB: ultimate bundle
and function / arbitrary and function / arbitrary software option
waveform generator waveform generator
Better 25% • DSOX6WAVEGEN2: 2-channel
• D3000AUTB: Automotive • D3000PWRB: power analysis function / arbitrary waveform
software option software option generator
• DP0010A: 250-MHz • N2790A: 100-MHz high- • N2750A: 1.5-GHz differential
differential active probe voltage differential active active probe
• DP0021A-009: automotive probe
accessory kit for DP001xA • 1147B: 50-MHz current probe
probes • U1880A: deskew fixture

MSO4154AAUT MSOX4154PWR MSOX6004JIT

• MSOX4154A: 4+16 channel, • MSOX4154A: 4+16 channel, • MSOX6004A: 4+16 channel,


1.5-GHz mixed-signal 1.5-GHz mixed-signal 1-GHz mixed-signal
oscilloscope oscilloscope oscilloscope
• D4000BDLB: Ultimate • D4000BDLB: ultimate bundle • DSOX6004A-02G: 2.5-GHz
bundle software option software option bandwidth option
Best 25% • DSOX4WAVEGEN2: • DSOX4WAVEGEN2: • D6000BDLB: ultimate bundle
2-channel function / arbitrary 2-channel function / arbitrary software option
waveform generator waveform generator • DSOX6WAVEGEN2: 2-channel
• DP0010A: 250-MHz • N2790A: 100-MHz high- function / arbitrary waveform
differential active probe voltage differential active generator
• DP0021A-009: automotive probe • N2751A: 3.5-GHz differential
accessory kit for DP001xA • N7026A: 150-MHz high- active probe
probes sensitivity current probe
• U1880A: deskew fixture

Basic Instruments | 27
Save 40% on InfiniiVision Software
Whether you are purchasing a new InfiniiVision oscilloscope or
already own one, you can purchase a qualifying InfiniiVision software LEARN MORE
package at a 40% off discount for a limited time! Instantly unlock
the full potential of your InfiniiVision oscilloscope with high-end
application software that places automated measurements and
advanced analysis at your fingertips, getting you the insight you
need to quickly and easily innovate your best designs.

Aerospace & Ultimate


Automobile Embedded Power USB
Defense Bundle

2000X D2000AUTB NA D2000GENB NA NA D2000BDLB

3000X D3000AUTB D3000AERB D3000GENB D3000PWRB D3000USBB D3000BDLB

4000X D4000AUTB D4000AERB D4000GENB D4000PWRB D4000USBB D4000BDLB

6000X D6000AUTB D6000AERB D6000GENB D6000PWRB D6000USBB D6000BDLB

RF Signal Analyzer and


Signal Generator Bundle
Save up to 20% on essential RF signal analyzer and signal generator
bundles. The Keysight N9000B CXA signal analyzer and Keysight LEARN MORE
N5166B CXG signal generator provide an easy-to-use, solid foundation
for accurate, cost-effective RF testing in general-purpose applications.

Bundle option Discount N9000B CXA N5166B CXG

• Frequency range, 3 GHz


• Frequency range, 3 or 6 GHz
• Preamplifier, 3 GHz
Good 10% • RF bandwidth, 60 MHz
• Fine resolution attenuator
• Waveform memory size, 32 MSa
• Precision frequency reference

• Frequency range, 7.5 GHz


• Frequency range, 3 or 6 GHz
• Preamplifier, 7.5 GHz
Better 15% • RF bandwidth, 120 MHz
• Fine resolution attenuator
• Waveform memory size, 32 MSa
• Precision frequency reference

• Frequency range, 6 GHz


• Frequency range, 26.5 GHz
• RF bandwidth, 120 MHz
• Preamplifier, 26.5 GHz
Best 20% • Waveform memory size, 512 MSa
• Fine resolution attenuator
• AM, FM, phase modulation
• Precision frequency reference
• Waveform license 5-pack

Basic Instruments | 28
Buy One, Get Two Software Promotion
For a limited time, purchase any qualifying A-Series FieldFox
Handheld Analyzer and get two of our most popular software options LEARN MORE
for free. Options include:

• TDR cable measurements


• GPS receiver
• analog demodulation
• EMI measurements

Ranging from 4 to 54 GHz, the industry’s most integrated handheld


analyzer family just gets more powerful. FieldFox provides the
greatest accuracy, superior RF performance, a rugged weather
resistance package, and complete software upgradeability. And now,
you can acquire more application capabilities at no extra charge.

Basic Instruments | 29
KEYSIGHTCARE

Expert Technical Support


In addition to your three-year warranty, you will receive three years of KeysightCare Technical Support on all basic
instruments in this catalog.

You have 24/7 access to the KeysightCare support portal that contains a prolific knowledge center and self-service web
portal. The knowledge center contains thousands of programming examples and detailed technical articles based on
decades of R&D and test experience. The self-service web portal enables you to log support requests and get a two-
business day committed technical response from our experts.

Mitigate risk and avoid project delays with technical support coverage. Get personalized technical support with
KeysightCare Technical Support.

Continue to Lock in Peak Performance with KeysightCare Enhanced


Ensure accurate measurements and priority service to achieve greater peace of mind.

• Extend your peace of mind and eliminate budgetary surprises for up to 5 years with KeysightCare Enhanced,
available as an upgrade option in select countries.
• KeysightCare Enhanced provides fast answers for unexpected test challenges with a 2 business hour technical
response time.
• KeysightCare Enhanced includes a calibration service of
choice based on the equipment’s recommended calibration
interval with a 5 business day committed turnaround time
(excluding shipment and customs processing).
• Keep your project schedules on track and receive Now Available on Basic Instruments
priority repair coverage with a 7 business day
committed turnaround time (excluding shipment LOG INTO THE SUPPORT PORTAL
and customs processing). VISIT US TO LEARN MORE

Basic Instruments | 30
Keysight enables innovators to push the boundaries of engineering by quickly solving design, emulation, and
test challenges to create the best product experiences. Start your innovation journey at www.keysight.com.

This information is subject to change without notice.


© Keysight Technologies, 2020 – 2023, Published in USA, January 19, 2023, 5992-0112EN

You might also like