Outotec (Finland) Oy: M3 Doc No. M205-020
Outotec (Finland) Oy: M3 Doc No. M205-020
Outotec (Finland) Oy: M3 Doc No. M205-020
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Title page / cover sheet Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+TITLE_PAGE OU750007183 Page 1
0 1 2 3 4 5 6 7 8 9
higher-level function mounting location Page Page description supplementary page field Date Edited by
PF1200+F1 6 Bus cabling diagram, Profibus line for motors 13/11/2017 CAW
PF1200+F1 6.a Bus cabling diagram, Profibus line for motors 13/11/2017 CAW
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Table of contents Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+CONTENTS OU750007183 Page 1
0 1 2 3 4 5 6 7 8 9
higher-level function mounting location Page Page description supplementary page field Date Edited by
PF1200 PF1200+X1 10 Emergency stop relays KA130, KA100, KA101 and KA112 06/09/2017 CAW
PF1200+X1 17 Allen Bradley logic, Ethernet switch and HMI 13/11/2017 CAW
PF1200+X1 32 Output modules DO5, DO6, DO7 and DO8 13/11/2017 CAW
PF1200+X1 33 Output modules DO9, DO10, DO11 and DO12 06/09/2017 CAW
PF1200+X1 34 Output modules DO13, DO14, DO15 and DO16 06/09/2017 CAW
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Table of contents Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+CONTENTS OU750007183 Page 2
0 1 2 3 4 5 6 7 8 9
higher-level function mounting location Page Page description supplementary page field Date Edited by
PF1200 PF1200+X1 38 Analog output modules AO3 and AO4 13/11/2017 CAW
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Table of contents Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+CONTENTS OU750007183 Page 3
0 1 2 3 4 5 6 7 8 9
higher-level function mounting location Page Page description supplementary page field Date Edited by
PF1200 PF1200+X2 25 Analog input modules AI1 and AI2 13/11/2017 CAW
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Table of contents Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+CONTENTS OU750007183 Page 4
0 1 2 3 4 5 6 7 8 9
EMERGENCY STOP
V* A M
1
2
M01
3
4
M03&04
5 M03
6 M04
M07
7 M02M05
8
Y50
9
1 2 3
B1
0
X
S714
B415
ACT SELECTOR
S725 S723
ACKNL A START
V0* V V1*
UP/FWD M DN/REV
PF1192
X2
EMERGENCY STOP START / RUN STOP/STOPPED ACKNL / ALARM MODE SELECTION HYDRAULIC UNIT
0 1
0 TEST
B516 X20* CONNECTOR FOR HAND HELD UNIT AND ENABLE SWITCH
S702
EMERGENCY STOP
V* A M
1
2
01
3
04
4 3&
M0
5 M03
6 M04
M07
7 M0
2 M0
8 5
Y5
0
9
1 2 3
B1
0
S700 S714
ACT SELECTOR
MAIN SWITCH
S725 S723
ACKNL A START
V0* V V1*
UP/FWD M DN/REV
X1
X2
X3
X1
HANDHELD-UNIT
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 F1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Electrification layout for filter Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+F1 OU750007183 Page 1
0 1 2 3 4 5 6 7 8 9
CUSTOMER OUTOTEC OUTSIDE FILTER
TERMINAL BOX X2
S838A 295300-ZS-632F
CONTROL CABIN X1 B491 295300-PT-635F
295300-JB
-W550 1) 4) 295300-PLC-002 S839A 295300-ZS-633F
295300-JB
RED INDUSTRIAL 1 ETHERNET TCP/IP B921 295300-FT-630F
S742 S873 295300-ZS-634F
-W551 1) S741 B503 295300-ZT-631F
TO CUSTOMER'S MCC PROFIBUS DP S205 295300-ZSC-631F
S202 295300-ZSC-630F B505 295300-ZT-630F
-W552 1) S207 295300-ZSC-633F
PLANT DCS ABB 880xA PROFIBUS DP S206 295300-ZSC-632F
-W207
X209 X207
BAG FILLING STATION 295400-BN-010 ETHERNET TCP/IP
-W553 1) S708 295300-PF001-SP S109 295300-ZSO-634F
-W202 1)
S209 295300-ZSC-634F
S710 295300-PF001-ST B419 295300-PT-632F
TO CUSTOMER 295300-JBPA-112 PROFIBUS PA
-W554 1) -W502 1)
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B 02.11.2017 CAW REV. F FOR APPROVAL DRN CXZ DQ-160271 F1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Cabling diagram Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+F1 OU750007183 Page 2
0 1 2 3 4 5 6 7 8 9
FROM Q04
R04 S601 295300-TS-630F
3
YQ1 295300-FV-630F
FROM Q05 M05
3
1) T. BOX S141
TERMINAL BOX X8
X8.1 S241
295300-JB
1) ZS111.1 295300-ZS-635F
1) ZS111.2 295300-ZS-636F
1) ZS111.3 295300-ZS-637F
-W208 1) 1)
FROM X2 ZS111.4 295300-ZS-638F
1) ZS111.5 295300-ZS-639F
1) S911 295300-ZS-651F
1) S912 295300-ZS-652F
1) T. BOX S142
X8.2 S242
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 F1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Cabling diagram Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+F1 OU750007183 Page 3
0 1 2 3 4 5 6 7 8 9
CUSTOMER OUTOTEC
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B 02.11.2017 CAW REV. F FOR APPROVAL DRN CXZ DQ-160271 F1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Cabling diagram Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+F1 OU750007183 Page 4
0 1 2 3 4 5 6 7 8 9
Control cabin X1 Terminal box X2
+PF1200+CUSTOMER-W502
SIE.6XV1840-2AH10
+PF1200+X2-CW502
+PF1200+X1-CW502 HUM.HSK-K M16x1,5 (4-8)
HUM.HSK-K M16x1,5 (4-8)
+PF1200+X1-SW1 +PF1200+X1-KA130
++X1/17.1 +PF1200+X1-WETH4 ++X1/10.0
REV. A 02.11.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 F1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Bus cabling diagram, Ethernet Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+F1 OU750007183 Page 5
0 1 2 3 4 5 6 7 8 9
OUTOTEC CUSTOMER MCC 1) CABLES AND CONNECTORS ARE IN CUSTOMER'S DELIVERY
SIE.6ES7972-0BB52-0XA0
GN
A1 1) 1) 1) 1) 1) 1)
Bus address: 30
RD
B1
Plug is connected
to the PRO1 RD GN RD GN RD GN RD GN RD GN RD GN RD GN RD GN RD GN RD GN
SH
Termination
resistor: ON A2
on off B2
XCA
XCA
XCA
XCA
XCA
XCA
XCA
XCA
XCA
XCA
PE
PE
PE
PE
PE
XPM01 XPM05 XPR04 -XPM02.1 XPM02.2
SH
2 1 1 2 1 1 2 1 1 2 1 1 2 1 1
RxD/TxD-P
RxD/TxD-N
RxD/TxD-P
RxD/TxD-N
RxD/TxD-P
RxD/TxD-N
RxD/TxD-P
RxD/TxD-N
RxD/TxD-P
RxD/TxD-N
+PF1200+X1
ABB
SEE X1 PAGE 17
PROFIBUS PROFIBUS PROFIBUS PROFIBUS PROFIBUS
Bus address: 31 Bus address: 32 Bus address: 33 Bus address: 34 Bus address: 35
HYDRAULIC UNIT, MAIN PUMP M01 HYDRAULIC UNIT, COOLER M05 HYDRAULIC UNIT, HEATER R04 PRESSSING WATER PUMP M02.1 PRESSSING WATER PUMP M02.2
295300-HY-002A 295300-HY-002B 295300-HY-003 295300-PP-033 295300-PP-034
1) 1) 1) 1) 1)
RD GN RD GN RD GN RD GN RD GN RD GN RD GN RD GN RD GN RD GN
XCA
XCA
XCA
XCA
XCA
XCA
XCA
XCA
XCA
XCA
PE
PE
PE
PE
PE
XPM15.1 XPM15.2 XPM06.1 XPM06.2 XPM09.1
2 1 1 2 1 1 2 1 1 2 1 1 2 1 1
RxD/TxD-P
RxD/TxD-N
RxD/TxD-P
RxD/TxD-N
RxD/TxD-P
RxD/TxD-N
RxD/TxD-P
RxD/TxD-N
RxD/TxD-P
RxD/TxD-N
PROFIBUS PROFIBUS PROFIBUS PROFIBUS PROFIBUS
Bus address: 36 Bus address: 37 Bus address: 38 Bus address: 39 Bus address: 40
MANIFOLD FLUSH PUMP M15.1 MANIFOLD FLUSH PUMP M15.2 CLOTH WASH PUMP M06.1 CLOTH WASH PUMP M06.2 FEED PUMP M09.1
295300-PP-035 295300-PP-036 295300-PP-037 295300-PP-038 295300-PP-088
1) 1) 1) 1) 1)
6.a.1
RD GN RD GN RD GN RD GN RD GN RD GN RD GN RD GN RD GN RD GN
XCA
XCA
XCA
XCA
XCA
XCA
XCA
XCA
XCA
XCA
PE
PE
PE
PE
PE
XPM09.2 XPM08.5 XPM08.1 XPM08.2 XPM08.3
2 1 1 2 1 1 2 1 1 2 1 1 2 1 1
RxD/TxD-P
RxD/TxD-N
RxD/TxD-P
RxD/TxD-N
RxD/TxD-P
RxD/TxD-N
RxD/TxD-P
RxD/TxD-N
RxD/TxD-P
RxD/TxD-N
PROFIBUS PROFIBUS PROFIBUS PROFIBUS PROFIBUS
Bus address: 41 Bus address: 42 Bus address: 43 Bus address: 44 Bus address: 45
FEED PUMP M09.2 DOWNLOAD SCREW M08.5 LUMP BREAKER M08.1 LUMP BREAKER M08.2 LUMP BREAKER M08.3
295300-PP-089 295300-XM-004 295300-RB-001 295300-RB-002 295300-RB-003
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B 02.11.2017 CAW REV. F FOR APPROVAL DRN CXZ DQ-160271 F1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Bus cabling diagram, Profibus line for Serial no = PF1200 Drawing number
REV. D REV. H APPR motors Location + PF1200+F1 OU750007183 Page 6
0 1 2 3 4 5 6 7 8 9
OUTOTEC CUSTOMER MCC 1) CABLES AND CONNECTORS ARE IN CUSTOMER'S DELIVERY
RD GN RD GN RD GN RD GN RD GN
XCA
XCA
XCA
XCA
XCA
XCA
PE
PE
PE
XPM08.4 XPMV08.1 XPMV08.2
2 1 1 2 1 1 2 1 1
RxD/TxD-P
RxD/TxD-N
RxD/TxD-P
RxD/TxD-N
RxD/TxD-P
RxD/TxD-N
PROFIBUS PROFIBUS PROFIBUS
Bus address: 46 Bus address: 47 Bus address: 48
LUMP BREAKER M08.4 CHUTE SLIDE GATE MV08.1 CHUTE SLIDE GATE MV08.2
295300-RB-004 295300-CH-001 295300-CH-003
CUSTOMER
-PRO2-XP1
BUS-CONNECTOR
SIE.6ES7972-0BB52-0XA0
GN
A1 1)
Bus address: 10 TO DCS
RD
B1
Plug is connected
to the PRO2
SH
Termination
resistor: ON A2
on off B2
SH
+PF1200+X1
SEE X1 PAGE 17
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B 02.11.2017 CAW REV. F FOR APPROVAL DRN CXZ DQ-160271 F1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Bus cabling diagram, Profibus line for Serial no = PF1200 Drawing number
REV. D REV. H APPR motors Location + PF1200+F1 OU750007183 Page 6.a
0 1 2 3 4 5 6 7 8 9
+PF1200+CUSTOMER
295300-JBPA-112
+PF1200+CUSTOMER-PA2
PROBIBUS-PA JUNCTION BOX
ALL.1788FBJB6
L606562
+PF1200+CUSTOMER-W554
1) Drying Air accumulator pressure
T1 +PF1200+F1-PT612D PRESSURE TRANSMITTER
D1 295300-PT-612D
RD RD E&H.CERABAR M PMP51-2CRM2/139
1) 1 PA NODE 4 L605432
GN GN 1) +PF1200+CUSTOMER-LT620A
1) +PF1200+CUSTOMER-LT622A
D4 295300-LIT-622A Filtrate Tank Level
PA NODE 5
+PF1200+X1-PA1
ETHERNET /IP TO PROBIBUS-PA LINKING DEVICE
ALL.1788-EN2PAR
L605325
PA NODE 1
+ ++X1-SW1:8
- ETH1 ++X1/17.5
S
++X1-F9:2
++X1/7.1 +
++X1-0VDC:40
++X1/6.4 -
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B 02.11.2017 CAW REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Profibus PA connections Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+F1 OU750007183 Page 7
0 1 2 3 4 5 6 7 8 9
CUSTOMER
OUTOTEC
+PF1200+X1-CW902
HUM.HSK-K M16x1,5 (2-6)
+PF1200+X1
FILTER HYDR_U
FRAME FRAME
++X1/4.3
-PE1 -PE5
-W905.1
EUP.H07 V-R 1X6 YE-GR
-W901.1 -W901.3 3m -W905.3
EUP.H07 V-R 1X6 YE-GR EUP.H07 V-R 1X16 YE-GR EUP.H07 V-R 1X16 YE-GR
7m 2m +PF1200+X5-CW905.1 3m
HUM.HSK-K M16x1,5 (2-6)
-W901.2 -W901.4
EUP.H07 V-R 1X6 YE-GR EUP.H07 V-R 1X6 YE-GR
-W905.5 -W905.2 -W905.4
EUP.H07 V-R 1X16 YE-GR EUP.H07 V-R 1X16 YE-GR EUP.H07 V-R 1X16 YE-GR
5m 5m
3m 3m 3m
+PF1200+X2-CW901.2 +PF1200+X12-CW901.4
HUM.HSK-K M16x1,5 (2-6) HUM.HSK-K M16x1,5 (2-6)
-MOTOR05 -OIL_TANK -FRAME
+PF1200+X2 +PF1200+X12
-PE5.2 -PE5.4
-PE5.5
-PE1.4
++X2/2.7
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 F1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Grounding diagram for filter Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+F1 OU750007183 Page 8
0 1 2 3 4 5 6 7 8 9
+PF1200+CUSTOMER-W903
1x70 YE-GR
CUSTOMER
OUTOTEC
PWS
FRAME
-PE3
-W903.5
-W903.1 -W903.3 EUP.H07 V-R 1X16 YE-GR
EUP.H07 V-R 1X16 YE-GR EUP.H07 V-R 1X6 YE-GR 3m
3m 3m
MOTOR02.2
MOTOR02.1 +PF1200+X3.2
-PE3.5
-PE3.1
-PE3.3
-W903.2
EUP.H07 V-R 1X6 YE-GR
3m -W903.4
EUP.H07 V-R 1X16 YE-GR
2m
+PF1200+X3.1-CW903.2
HUM.HSK-K M16x1,5 (2-6)
+PF1200+X3.1 FRAME
-PE3.2
-PE3.4
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 F1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Grounding diagram for filter Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+F1 OU750007183 Page 9
0 1 2 3 4 5 6 7 8 9
65 65
65
SPANISH
20
20
SWITCH PRINCIPAL UNID HIDRAULICA PARADA EMERGENCIA 6mm 10mm
30
TEXT FONTS: 4mm
0 1 TEXT STYLE: WHITE LABEL, BLACK TEXT
S701 EMERGENCY STOP: RED TEXT
PARADA EMERGENCIA 65
S703
X208
20
PARADA EMERGENCIA
95 mm
S705
X209
PARADA EMERGENCIA
80
85 mm
S708 / H708 2 pcs
Φ
PARO/DETENIDO
0 TEST
S710 / H710 STICKER
ARRANQUE/CORRER BACKGROUND: YELLOW
A BORDERS AND SYMBOL: BLACK
S733 / H733
RECON / ALARM
S780 140
S780
SELECCION MODO
40
RECON PUERTA AUXILIAR EXTERNO APAGADO TENSIONES 30 CIRCUITOS ENERGIZADOS DESCONECTAR
(CABLES ANARANJADOS) ALIMENT ANTES DE INTERVENIR
S742 / H742
140 BACKGROUND: YELLOW RAL 1003
RECON PUERTA TEXT STYLE: RED LABEL, WHITE TEXT TEXT: BLACK
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 F1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Labels, Spanish Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+F1 OU750007183 Page 10
0 1 2 3 4 5 6 7 8 9
ENGLISH
PF1200
X1
PF1200
X5
TEXT FONTS: 4mm 6mm 10mm
TEXT STYLE: WHITE LABEL, BLACK TEXT
40
295300-PLC-002 295300-JB EMERGENCY STOP: RED TEXT
L605364 L605367
PF1200 PF1200
X2 X12
295300-JB 295300-JB
L605365 L605368
PF1200 PF1200
X3.1 X22
295300-JB 295300-JB
L605366
PF1200 PF1200
X3.2 X8
295300-JB 295300-JB
L605369
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 F1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Labels, Spanish Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+F1 OU750007183 Page 11
0 1 2 3 4 5 6 7 8 9
40
text in black S725 S723 ¡ANTES DE OPERAR LA
MAQUINARIA SIEMPRE
RECON. A ARRANQUE ASEGURESE DE QUE NO
27
text in green
PF1200
20
HAY NADIE EN LAS ZONAS
text in red V DE PELIGRO!
46
text in blue H
2.5
text in black M08.1&2 X1 REV 65
TO HANDHELD UNIT (HANDLE) M08.3&4 X2 REV BACKGROUND: YELLOW RAL 1003
X3 TEXT: BLACK
text in
65 green
V* H
HC5
A
2
Y51
1
S702
2
20
3
PARADA EMERGENCIA 4
5 HM9
text in text in
red 6 Y8x blue
61
7 M05
R0
8 4
S714
M 08.2
9
1 2 3
V0
MV
SELECTOR DEL DISPOTIVO
0
8.
X
1
DE ACTIVACION
text in black
REV. A 27.06.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 F1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation HH-U Labels, Spanish Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+F1 OU750007183 Page 12
0 1 2 3 4 5 6 7 8 9
OUTOTEC
1) 1) 1)
3+PE 3+PE
3+PE
-M01 -M05
M -R04 M
295300-HY-002A
Hydraulic unit main pump,25HP(18.5kW),1800r/min 3~ 295300-HY-003 R 295300-HY-002B
Hydraulic unit cooler,0.4HP(0.25kW),1800r/min 3~
Specified by mechanical designer
Hydraulic unit heater,1kW 3~ Specified by mechanical designer
Specified by mechanical designer
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B 02.11.2017 CAW REV. F FOR APPROVAL DRN CXZ DQ-160271 F1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Motors, single line diagram Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+F1 OU750007183 Page 13
0 1 2 3 4 5 6 7 8 9
+PF1200+CUSTOMER-KV08.1.1 +PF1200+CUSTOMER-KV08.2.1
-U02.1 +PF1200+CUSTOMER-U02.2
FREQUENCY CONVERTER f1 FREQUENCY CONVERTER f1
ABB.ACS880-01-027A-5+E200+K454
f2 f2
L605671
+PF1200+CUSTOMER-W102.1 +PF1200+CUSTOMER-W102.2 +PF1200+CUSTOMER-W1V08.1 +PF1200+CUSTOMER-W1V08.2
According to customer standard According to customer standard According to customer standard According to customer standard
CUSTOMER 5x*** 5x*** 5x*** 5x***
OUTOTEC
1) 1) 1) 1)
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B 02.11.2017 CAW REV. F FOR APPROVAL DRN CXZ DQ-160271 F1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Motors, single line diagram Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+F1 OU750007183 Page 14
0 1 2 3 4 5 6 7 8 9
+PF1200+CUSTOMER-U09.1 +PF1200+CUSTOMER-U09.2
FREQUENCY CONVERTER f1 FREQUENCY CONVERTER f1
f2 f2
1) 1) 1) 1)
CUSTOMER
OUTOTEC
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 F1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Motors, single line diagram Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+F1 OU750007183 Page 15
0 1 2 3 4 5 6 7 8 9
1) 1) 1) 1)
CUSTOMER
OUTOTEC
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B 02.11.2017 CAW REV. F FOR APPROVAL DRN CXZ DQ-160271 F1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Motors, single line diagram Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+F1 OU750007183 Page 16
0 1 2 3 4 5 6 7 8 9
1) 1) 1) 1)
CUSTOMER
OUTOTEC
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 F1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Motors, single line diagram Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+F1 OU750007183 Page 17
0 1 2 3 4 5 6 7 8 9
3 3 3
+PF1200+CUSTOMER-K008.5
+PF1200+CUSTOMER-U08.5
FREQUENCY CONVERTER f1
f2
+PF1200+CUSTOMER-Q08.5
+PF1200+CUSTOMER-QCP010 +PF1200+CUSTOMER-QCP012
1) 1) 1)
CUSTOMER
OUTOTEC
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 F1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Motors, single line diagram Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+F1 OU750007183 Page 18
0 1 2 3 4 5 6 7 8 9
THER1
E2 T1
KA111.2
KA111.3
KA110
KA111
KA100 S701
EMERGENCY STOP
S710/H710
START / RUN
S708/H708
STOP/STOPPED
S733/H733
ACKNL / ALARM
S780
MODE SELECTION
S755
HYDRAULIC UNIT
0 TEST
0 1
DUMMY 4
1 2 3 4 5 6 7 1 2
DO DO DO DO DO DO DO DO DO DO DO AI AI AO AO AO DI DI DI DI DI DI DI DI DI DI DI DI DI DI DI DI DI
DUMMY 2
DUMMY 3
8 9 10 11 12 13 14 15 16 17 18 1 2 1 2 3 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B 02.11.2017 CAW REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Control cabin layout, LOG-AB Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X1 OU750007183 Page 1
0 1 2 3 4 5 6 7 8 9
PF1200
PF1200
L605364
685
231 338
HMI
257
7 X Φ22 S701
EMERGENCY STOP
S710/H710
START / RUN
S708/H708
STOP/STOPPED
S733/H733
ACKNL / ALARM
S780
MODE SELECTION
S755
HYDRAULIC UNIT
0 1
0 TEST
260 S700
MAIN SWITCH
330 1680
S700
400 WARNING:
LIVE CIRCUITS INSIDE. DISCONNECT
1600
POWER SUPPLIES BEFORE SERVICING.
540
680
1050
HT1
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Dimensional layout, control panel X1 with Serial no = PF1200 Drawing number
REV. D REV. H APPR HMI Location + PF1200+X1 OU750007183 Page 2
0 1 2 3 4 5 6 7 8 9
3x45=135 519.5
.5
Ø 25 6.5
0x 1
Ø40.5 1 3 0xØ
.5
20
xØ
15
4x35=140
138
40
40
55
2.5
Ø3
141.5
3x
95
5x35=175 76.5
79.5 2x50=100 4x40=160 301.5
511.5
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Control cabin plate for cable clamps Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X1 OU750007183 Page 3
0 1 2 3 4 5 6 7 8 9
-N:1
5.0
2,5 2,5
2 4 6
-S700
POWER DISC. SWITCH 1 3 5
ABB.OT 25F3
L27601
ASSEMBLY BOX
PLATE FRAME COVER
-AC.X1 L N PE
1 2 GNYE
295300-PLC-002 -CW010
HUM.HSK-K M25X1,5 (9 - 16) ++F1/8.3 -FE1.1 1
CONTROL CABIN X1
CUSTOMER
1 2 GNYE
-CW011
HUM.HSK-K M20X1,5 (6-12)
+PF1200+CUSTOMER-W010
LAPP.ÖLFLEX CLASSIC 110 3G2,5
+PF1200+CUSTOMER
-X1 L N PE -FEB 1
VOLTAGE SUPPLY
120VAC , 60Hz, 16A
FROM CUSTOMER
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Voltage distribution, 120VAC Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X1 OU750007183 Page 4
0 1 2 3 4 5 6 7 8 9
-S700
4.9
-N 1 2 3 4 5
1 1 1 1
-FAC2 -FAC3 -FAC4 -FAC5
1 AUTOMATIC FUSE AUTOMATIC FUSE AUTOMATIC FUSE AUTOMATIC FUSE
2 2 2 2
AUTOMAT. SINGLE-POLE C 4 A AUTOMAT. SINGLE-POLE C 6 A AUTOMAT. SINGLE-POLE C 6 A AUTOMAT. SINGLE-POLE C 6 A
SIE.5SY4 104-7 SIE.5SY4 106-7 SIE.5SY4 106-7 SIE.5SY4 106-7
L08721 L08722 L08722 L08722
2
FAC1
CIRCUIT BREAKER
-THER1
Setting range: 3
RESIDUAL CURRENT PROTECTIVE DEVICE, RCBO C 6A
SIE.5SU1 354-7KK06 50 – 90 %
relative humidity
L45435
REGULATOR 2
PE RIT.SK 3118.000 18.3 18.4
L02363
1
L PE N
32.2 32.3
-T1
POWER SUPPLY UNIT -PE
115/230VAC / 24VDC / 10A
IFM.DN4013 DC ok
1 2 1,5 1,5
-E2 L50833
OUTLET + + - -
250VAC 16A
PHO.SD-D/SC/LA
-0VDC:31
L29539
-FDC2:1
-FDC1:1
-HT1
-X202 1L 2N PE
295300-PLC-002
CONTROL CABIN X1
FILTER
+PF1200+CUSTOMER-W202
UNIKA.UNIDRALL 2500 UL 3G2,5
++X2/2.1
1 2 GNYE
-CW202
HUM.HSK-K M20X1,5 (6-12)
++X2/2.1
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Voltage distribution, 120VAC Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X1 OU750007183 Page 5
0 1 2 3 4 5 6 7 8 9
1
-FDC1
AUTOMATIC FUSE 2
AUTOMAT. SINGLE-POLE C 6 A
SIE.5SY4 106-7
L08722
-DC1 1 2 3 4 5
-DC.X3:DC1
-DC.X5:DC1
-F24:1
-F9:1
7.0
1 1 1 1 1 1 1 1
-F1 -F2 -F3 -F4 -F5 -F6 -F7 -F8
AUTOMATIC FUSE 2 AUTOMATIC FUSE 2 AUTOMATIC FUSE 2 AUTOMATIC FUSE 2 AUTOMATIC FUSE 2 AUTOMATIC FUSE 2 AUTOMATIC FUSE 2 AUTOMATIC FUSE 2
AUTOMAT. SINGLE-POLE C 4 A AUTOMAT. SINGLE-POLE C 2 A AUTOMAT. SINGLE-POLE C 2 A AUTOMAT. SINGLE-POLE C 1 A AUTOMAT. SINGLE-POLE C 2 A AUTOMAT. SINGLE-POLE C 2 A AUTOMAT. SINGLE-POLE C 1 A AUTOMAT. SINGLE-POLE C 1 A
SIE.5SY4 104-7 SIE.5SY4 102-7 SIE.5SY4 102-7 SIE.5SY4 101-7 SIE.5SY4 102-7 SIE.5SY4 102-7 SIE.5SY4 101-7 SIE.5SY4 101-7
L08721 L08720 L08720 L08719 L08720 L08720 L08719 L08719
-DUMMY3:6
-DUMMY2:6
-KA111:93
-SW2:+
-SW1:1
-HMI:+
-BK1:6
17.0 17.7 12.1 19.4 18.0 17.0 17.3 19.1
-T1:- -DC
5.5
-0VDC 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50
-DC.X3:0VDC
-DC.X5:0VDC
-DUMMY1:4
-DUMMY2:4
-DUMMY3:4
-KA100:A2
-KA112:A2
-KA100:0V
-X8.1:1-
-SW1:2
-SW2:-
-BK1:4
-H2:x2
-HMI:-
-PA1:-
295300-PLC-002
CONTROL CABIN X1
8.6 17.7 16.1 10.1 17.0 10.4 17.0 9.2 9.5 ++F1/7.0 10.7 18.0 18.2 19.1 19.4 17.3
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Voltage distribution, 24VDC Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X1 OU750007183 Page 6
0 1 2 3 4 5 6 7 8 9
1 1 1 1
-F9 -F10 -F11 -F12
AUTOMATIC FUSE 2 AUTOMATIC FUSE 2 AUTOMATIC FUSE 2 AUTOMATIC FUSE 2
AUTOMAT. SINGLE-POLE C 2 A AUTOMAT. SINGLE-POLE C 2 A AUTOMAT. SINGLE-POLE C 2 A AUTOMAT. SINGLE-POLE C 2 A
SIE.5SY4 102-7 SIE.5SY4 102-7 SIE.5SY4 102-7 SIE.5SY4 102-7
L08720 L08720 L08720 L08720
-DC3 1 2 3 4 5 6 7 8 9 10
-KA100:24V
-KA100:A1
-KA112:Y1
-S733:23
-X8.2:1
-X8.2:4
-X8.2:7
-X8.3:1
-PA1:+
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Voltage distribution, 24VDC Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X1 OU750007183 Page 7
0 1 2 3 4 5 6 7 8 9
1
-F24
1 13 21 AUTOMATIC FUSE 2
-FDC2 AUTOMAT. SINGLE-POLE C 1 A
AUTOMATIC FUSE 2 14 22 SIE.5SY4 101-7
AUTOMAT. SINGLE-POLE C 6 A L08719
/21.3
SIE.5SY4 106-7
L08722
13
S2
RIT.SZ 4315.820 14
CONNECTING CABLE
L601192
x1
-H2
RIT.SZ 4140.830
LAMP x2
L601194
-0VDC:31
6.1
1 1 1
-F21 -F22 -F23
AUTOMATIC FUSE 2 AUTOMATIC FUSE 2 AUTOMATIC FUSE 2
AUTOMAT. SINGLE-POLE C 4 A AUTOMAT. SINGLE-POLE C 1 A AUTOMAT. SINGLE-POLE C 4 A
SIE.5SY4 104-7 SIE.5SY4 101-7 SIE.5SY4 104-7
L08721 L08719 L08721
13 43
-KA112 -KA110
/10.7 14 /11.1 44
-DC2 21 22 23 24 25
-DUMMY1:6
-DC.X5:DC2
18.1 9.6
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Voltage distribution, 24VDC Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X1 OU750007183 Page 8
0 1 2 3 4 5 6 7 8 9
-0VDC:38
-DC1:4
-0VDC:39
-DC1:5
-DC2:21
PE PE
+PF1200+F1-W205
+PF1200+F1-W203.1 UNIKA.UNIDRALL 2500 UL 12G1
UNIKA.UNIDRALL 2500 UL 25G1
15 m
15 m
1 2 GNYE 1 2 3 GNYE
-CW203.1 -CW205
HUM.HSK-K M25x1,5 (13-18) HUM.HSK-K M25X1,5 (9 - 16)
+PF1200+X3.1 +PF1200+X5
-CW203.1 -CW205
HUM.HSK-K M25x1,5 (13-18) HUM.HSK-K M25X1,5 (9 - 16)
GNYE 1 2 GNYE 1 2 3
-DC.X3 -DC.X5
DC1 DC1 DC1
0VDC 0VDC
PE 0VDC PE 0VDC
1 1 1
-F31 PE -F51 -F52
AUTOMATIC FUSE 2 AUTOMATIC FUSE 2 AUTOMATIC FUSE 2
AUTOMAT. SINGLE-POLE C 1 A AUTOMAT. SINGLE-POLE C 1 A AUTOMAT. SINGLE-POLE C 4 A
SIE.5SY4 101-7 SIE.5SY4 101-7 SIE.5SY4 104-7
++X3.1-X3:1+
++X3.1-X3:1-
++X5-X5A:10
++X5-X5:1+
L08719 L08719 L08721
++X5-X5:1-
22.5 22.5 23.5 23.5 37.5
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Voltage distribution for terminal boxes Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X1 OU750007183 Page 9
0 1 2 3 4 5 6 7 8 9
10.5
6.5
7.6
7.2 6.2 7.5 11.4 6.3 11.2 15.8 12.4 11.8 11.4
-F10:2
-0VDC:34
-DC3:6
-KA110:51
-0VDC:36
-KA110:A2
-X8.5:11
-KA111.1:52
-KA111:52
-KA110:52
-KA100:O1
-0VDC:41
-DC3:7
-KA101:I0
A1 A2 Y1 Y2 13 23 33 43
A1 A2 C1+ C1- C0+ C0- 24V 24V 0V 0V I4 I5 I6 I7
CHANNEL 2
SWITCH S790
ENABLE
FEEDBACK
KA111.1
FEEDBACK
KA111
FEEDBACK
KA110
-KA130 -KA100 -KA112 K1
SAFETY RELAY SAFETY RELAY 13 14 SAFETY RELAY 13 14 /8.1
ETHERNET MODULE BASE UNIT 24VDC 23 24 EXPANDER MODULE 23 24
PILZ.PNOZ mc8p PILZ.PNOZ m1P ETH CHANNEL 1 PILZ.PZEX 4P 33 34
E-STOP
CHANNEL 2
E-STOP
KA102
FOR X2
POWER SUPPLY
FOR KA112
POWER SUPPLY
TO KA110
SIGNAL
TO KA111
SIGNAL
FEEDBACK
KA111.2
FEEDBACK
KA111.3
CHANNEL 1
SWITCH S790
ENABLE
LOOP
FEEDBACK
KA112
E-STOP RELAY
L38161 (773 103) L06522 43 44
L28574 K2
T0 T1 T2 T3 O0 O1 O2 O3 OA0 I0 I1 I2 I3
14 24 34 44
-KA101 -R1
-KA111.2:52
-KA111.3:52
SAFETY RELAY SAFETY RELAY
-KA112:A1
-KA110:A1
-KA111:A1
-KA112:Y2
PILZ.PNOZ MULTI BUS
-S701:11
-S701:21
-X8.5:10
TERMINATOR (779 110)
-X8.2:6
400) L28602
L28584
15.6 15.6 15.2 10.7 11.1 11.5 10.8 12.8 13.4 15.7
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Emergency stop relays KA130, KA100, Serial no = PF1200 Drawing number
REV. D REV. H APPR KA101 and KA112 Location + PF1200+X1 OU750007183 Page 10
0 1 2 3 4 5 6 7 8 9
10.4
10.3
10.4
-KA100:O2
-KA100:0V
-KA100:24V
-KA100:O3
-KA111.1:51
12.4
-KA111.1:A2
12.2
A1 A2 13 23 33 43 63 73 83 93 51 A1 A2 13 23 33 43 63 73 83 93 51
-KA110
13 14 /39.2 K1 -KA111
13 14 /39.2 K1
23 24 /39.2 23 24 /39.2
SAFETY RELAY SAFETY RELAY
33 34 /39.2 33 34 /40.2
PILZ.PNOZ S11 PILZ.PNOZ S11
43 44 /8.3 43 44 /40.2
L44927 L44927
63 64 63 64 /39.2
73 74 73 74 /13.1
83 84 K2 83 84 /12.5 K2
93 94 93 94 /12.1
51 52 /11.4 51 52 /11.8
14 24 34 44 64 74 84 94 52 14 24 34 44 64 74 84 94 52
-R2 -R3
PNOZ POWER PNOZ POWER
-KA101:I7
-KA101:I6
BUS TERMINATOR BUS TERMINATOR
10.6
10.6
295300-PLC-002
CONTROL CABIN X1
FILTER
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Emergency stop relays KA110 and KA111 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X1 OU750007183 Page 11
0 1 2 3 4 5 6 7 8 9
93 83
-KA111 -KA111
/11.5 94 /11.5 84
-KA111:51 -KA111.3:51
11.8 13.4
-KA111:A2 -KA111.3:A2
11.6 13.2
A1 A2 13 23 33 43 63 73 83 93 51 A1 A2 13 23 33 43 63 73 83 93 51
-KA111.1
13 14 /40.2 K1 -KA111.2
13 14 /41.2 K1
23 24 /40.2 23 24 /41.2
SAFETY RELAY SAFETY RELAY
33 34 /40.2 33 34 /41.2
PILZ.PNOZ S11 PILZ.PNOZ S11
43 44 /40.2 43 44 /41.2
L44927 L44927
63 64 /40.2 63 64 /41.2
73 74 /40.2 73 74 /41.2
83 84 /41.2 K2 83 84 K2
93 94 /41.2 93 94
51 52 /12.4 51 52 /12.8
14 24 34 44 64 74 84 94 52 14 24 34 44 64 74 84 94 52
-R4 -R5
PNOZ POWER PNOZ POWER
-KA101:I5
-KA101:I1
BUS TERMINATOR BUS TERMINATOR
10.6
10.6
295300-PLC-002
CONTROL CABIN X1
FILTER
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Emergency stop relays KA111.1 and Serial no = PF1200 Drawing number
REV. D REV. H APPR KA111.2 Location + PF1200+X1 OU750007183 Page 12
0 1 2 3 4 5 6 7 8 9
73
-KA111
/11.5 74
-KA111.2:51
12.8
-KA111.2:A2
12.6
A1 A2 13 23 33 43 63 73 83 93 51
-KA111.3
13 14 /39.2 K1
23 24 /39.2
SAFETY RELAY
33 34
PILZ.PNOZ S11
43 44
L44927
63 64
73 74
83 84 K2
93 94
51 52 /13.4
14 24 34 44 64 74 84 94 52
-R6
PNOZ POWER
-KA101:I2
BUS TERMINATOR
10.6
295300-PLC-002
CONTROL CABIN X1
FILTER
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Emergency stop relay KA111.3 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X1 OU750007183 Page 13
0 1 2 3 4 5 6 7 8 9
-S733:24
-X8.5:5
-X8.5:6
-X8.5:9
-X8.5:7
-X8.5:8
-S733:1
-S780:5
-X8.2:8
-X8.2:9
-X8.2:10
-X8.2:11
I6 I9 I10 I11 I12 I13 I17 I19 I2 I3 I4 I5
PUSH BUTTON
ACKNOWLEDGE
TO LEFT SIDE
HH CONNECTED
TO RIGHT SIDE
HH CONNECTED
CONNECTED
ENABLE SWITCH
PUSH BUTTON 1
HAND HELD
AUTO MODE
KEY SWITCH
TEST MODE
KEY SWITCH
LEFT SIDE 1
DOOR SWITCH
LEFT SIDE 2
DOOR SWITCH
RIGHT SIDE 1
DOOR SWITCH
RIGHT SIDE 2
DOOR SWITCH
-KA100
/10.1
FEEDBACK
PROCESS PUMPS
FEEDBACK
CHANNEL 1
E-STOP
CHANNEL 2
E-STOP
SIDE
ACK RIGHT
DOOR SWITCH
LOOP
FEEDBACK
KA102
SPARE
I0 I1 I7 I8 I14 I15 I16 I18
7.5
-DC3:5
-X8.1:23
-X8.1:3
-X8.2:2
-X8.2:3
-X8.2:5
-X8.3 1 2 3 4
16.7 16.8 15.2 15.2 15.2
1 2 1 2
295300-PLC-002 -CW003 -CW004
CONTROL CABIN X1 HUM.HSK-K M16x1,5 (4-8) HUM.HSK-K M16x1,5 (4-8)
CUSTOMER
1 2 1 2
+PF1200+CUSTOMER-W003 +PF1200+CUSTOMER-W004
LAPP.ÖLFLEX CLASSIC 110 2x0,75 LAPP.ÖLFLEX CLASSIC 110 2x0,75
+PF1200+CUSTOMER
11
11 11 11 11
K001
12
K002.1 K006.1 K009.1 K008.3
12 12 12 12
11
11 11 11 11
K004
12
K002.2 K006.2 K009.2 K008.4
MOTOR CONTROLS WITH EMERGENCY STOP CONTACT 12 12 12 12
- CABLE -W003: CONTACT FOR HYDRAULIC MOTORS: 11
11 11 11
- CABLE -W004: CONTACT FOR PROCESS MOTORS: K005
FOR HARDWARE MOTOR CONTROL CIRCUITS 12
K015.1 K008.1 KV08.1
12 12 12
FEEDBACK LOOP FROM CUSTOMER'S MCC MOTOR CONTACTORS
MUST BE CONNECTED, IF NOT USED, FILTER DOES NOT FULLFILL 11 11 11
SAFETY CATEGORY 2. K015.2 K008.2 KV08.2
12 12 12
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Emergency stop circuit, KA100 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X1 OU750007183 Page 14
0 1 2 3 4 5 6 7 8 9
-DC3:1
-KA100:T2
-KA100:T3
+DOOR
23 A 0 T 2 4 6
-S701 11 21
-S733 -S780 295300-PF001-PBE
295300-PF001-XA 24 295300-PF001-HS 1 3 5 BUTTON 12 22
BUTTON SWITCH emergency stop
YELLOW PUSH BUTTON KRA.CA10 A230-600 pushbutton
TEL.ZB4-BW0B53 FT1 V750D/3J TEL.XB4-BS8445
L04493 L27359 L04494
-KA100:I17
-KA100:I19
14.2 -KA100:I6 14.4 14.5
7.4 14.3 14.3 7.4 14.4 10.3 7.5 14.5 14.6 14.6 14.6 16.1 16.2 14.2 14.3 14.3 14.4 14.3 10.6 10.5
-DC3:2
-KA100:I7
-KA100:I8
-DC3:3
-KA100:I14
-KA100:O0
-DC3:4
-KA100:I2
-KA100:I3
-KA100:I4
-KA100:I5
-X8.1:1+
-X8.1:21+
-KA100:I9
-KA100:I10
-KA100:I12
-KA100:I13
-KA100:I11
-KA101:I3
-KA101:I4
-X8.2 1 2 3 4 5 6 7 8 9 10 11 PE -X8.5 1 2 3 4 5 6 7 8 9 10 11 PE
295300-PLC-002
CONTROL CABIN X1
CUSTOMER
+PF1200+CUSTOMER-W802 +PF1200+CUSTOMER-W811
UNIKA.UNIDRALL 2500 UL 12G1 UNIKA.UNIDRALL 2500 UL 12G1
++X2/7.2 ++X2/7.7
1 2 3 4 5 6 7 8 9 10 11 GNYE 1 2 3 4 5 6 7 8 9 10 11 GNYE
-CW802 -CW811
HUM.HSK-K M25X1,5 (9 - 16) HUM.HSK-K M25X1,5 (9 - 16)
++X2/7.2 ++X2/7.7
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Emergency stop circuit Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X1 OU750007183 Page 15
0 1 2 3 4 5 6 7 8 9
-0VDC:33
-X8.5:4
-KA100:I0
-KA100:I1
295300-PLC-002
-X8.1 1+ 1 1- 21+ 21 21- 2+ 2 2- 22+ 22 22- 3+ 3 3- 23+ 23 23-
CONTROL CABIN X1
FILTER
+PF1200+F1-W705 +PF1200+F1-W703
UNIKA.UNIDRALL 2500 UL 5G1 UNIKA.UNIDRALL 2500 UL 5G1
1 2 3 4 1 2 3 4
15 m 15 m
-CW703
HUM.HSK-K M20X1,5 (6-12)
-CW705 +PF1200+X3.1-CW703
HUM.HSK-K M20X1,5 (6-12) HUM.HSK-K M20X1,5 (6-12)
1 3 4 2 1 3 4 2
+PF1200+F1 +PF1200+X3.1
11 21 11 21
-S705 -S703
295300-HY002-PBE 12 22 295300-PP033/034-PBE 12 22
BUTTON BUTTON
TEL.XAL-K178F TEL.XB4-BS8445
L16099 L04494
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation External cables Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X1 OU750007183 Page 16
0 1 2 3 4 5 6 7 8 9
-RS232
+PF1200+CUSTOMER-W553
M L+ M PE BAG FILLING STATION PLC
-CW553
HUM.HSK-K M16x1,5 (4-8)
-WETH6 +PF1200+CUSTOMER-W552
PLANT DCS ABB 880xA
ETHERNET CABLE 3M -CW552
L11128 HUM.HSK-K M16x1,5 (4-8)
-0VDC:37
+PF1200+CUSTOMER-W551
TO CUSTOMER'S MCC
-F1:2
-CW551
PE HUM.HSK-K M16x1,5 (4-8)
-SW2
6.3
6.1
-0VDC:32
+PF1200+CUSTOMER-W550
-F2:2
FIBER OPTIC CABLE
-CW550
HUM.HSK-K M16x1,5 (4-8)
6.2
6.1
+PF1200+CUSTOMER
-WETH1 RED INDUSTRIAL 1
ETHERNET CABLE 1M -WETH2
PE
L11129 ETHERNET CABLE 3M
L11128
3
-FE1.1
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B 02.11.2017 CAW REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Allen Bradley logic, Ethernet switch and Serial no = PF1200 Drawing number
REV. D REV. H APPR HMI Location + PF1200+X1 OU750007183 Page 17
18
OU750007183 Page
X1
SEE PAGE X1/19
9
Drawing number
Project number
DQ-160271
PF 7.9/12.6 M1.6 1 45
-DO18
DIGITAL OUTPUT UNIT
+ PF1200+X1
ALL.1734-OW2
8
= PF1200
-DO17
DIGITAL OUTPUT UNIT
ALL.1734-OW2
-DO16
DIGITAL OUTPUT UNIT
Filter type
Serial no
Location
ALL.1734-OW2
-DO15
DIGITAL OUTPUT UNIT
ALL.1734-OW2
-DO14
7
ALL.1734-OW2
-DO13
DIGITAL OUTPUT UNIT
ALL.1734-OW2
-DO12
DIGITAL OUTPUT UNIT
ALL.1734-OW2
-DO11
DIGITAL OUTPUT UNIT
Page description
ALL.1734-OW2
6
-DO10
distribution
DIGITAL OUTPUT UNIT
ALL.1734-OW2
-DO9
DIGITAL OUTPUT UNIT
ALL.1734-OW2
-DO8
DIGITAL OUTPUT UNIT
ALL.1734-OW2
ALL.1734-EXT1
5
-W1
1m
-DI2
DIGITAL INPUT
ALL.1734-IA4
POWER SUPPLY MODULE
-DUMMY4
ALL.1734-EPAC
-N:5
POWER UNIT
5.9
L39819
4
PE
2
-FAC5:2
5.9
Customer name
-DO7
DIGITAL OUTPUT UNIT
3
ALL.1734-OW2
-DO6
DIGITAL OUTPUT UNIT
20/01/2017
ALL.1734-OW2
-DO5
CAW
CXZ
DIGITAL OUTPUT UNIT
ALL.1734-OW2
-DO4
DATE
APPR
DRN
CHD
OUTPUT UNIT
ALL.1734-OB4E
-DO3
2
X
OUTPUT UNIT
ALL.1734-OB4E
FOR APPROVAL
POWER FEED UNIT
PRELIMINARY
-DUMMY1
-0VDC:43
ALL.1734-FPD
6.5
CERTIFIED
L40408
4
PE
2
-KA112:14
8.1
6
-DO2
OUTPUT UNIT
1
ALL.1734-OB4E
-DO1
OUTPUT UNIT
ALL.1734-OB4E
H
G
E
F
REV.
REV.
REV.
REV.
COMMUNICATION MODULE
ETHERNET, POINT I/O
-0VDC:42
ALL.1734-AENTR
6.5
04.09.2017 CAW
L39812
++F1/5.3
-BK1
PE
2
-F5:2
6.5
6
0
D
A
C
B
REV.
REV.
REV.
REV.
19
OU750007183 Page
X1
9
Drawing number
Project number
DQ-160271
-DI19
DIGITAL INPUT UNIT
ALL.1734-IB4
-DI18
DIGITAL INPUT UNIT
PF 7.9/12.6 M1.6 1 45
ALL.1734-IB4
-DI17
+ PF1200+X1
ALL.1734-IB4
= PF1200
-DI16
DIGITAL INPUT UNIT
ALL.1734-IB4
-DI15
Filter type
Serial no
Location
Page description
DIGITAL INPUT UNIT
6
ALL.1734-IB4
distribution
-DI9
DIGITAL INPUT UNIT
ALL.1734-IB4
-DI8
DIGITAL INPUT UNIT
ALL.1734-IB4
-DI7
DIGITAL INPUT UNIT
ALL.1734-IB4
-DI6
5
ALL.1734-IB4
ALLENBRADLEY POINT I/O
POWER FEED UNIT
ALL. 1734-EP24DC
-DUMMY3
-0VDC:45
6.6
615622
4
PE
2
-F4:2
6.4
Customer name
-AO4
ANALOG OUTPUT UNIT
ALL. 1734-OE2C
-AO3
3
20/01/2017
-AO2
ANALOG OUTPUT UNIT
CAW
ALL. 1734-OE2C
CXZ
-AO1
ANALOG OUTPUT UNIT
DATE
APPR
ALL.1734-OE2V
DRN
CHD
-AI2
ANALOG INPUT UNIT
2
X
ALL. 1734-IE2C
-AI1
ANALOG INPUT UNIT
FOR APPROVAL
ALL. 1734-IE2C
PRELIMINARY
CERTIFIED
POWER FEED UNIT
-DUMMY2
-0VDC:44
ALL.1734-FPD
6.6
L40408
4
PE
2
-F8:2
6.8
6
1
H
G
E
F
REV.
REV.
REV.
REV.
04.09.2017 CAW
0
D
A
C
B
REV.
REV.
REV.
REV.
0 1 2 3 4 5 6 7 8 9
CONTROL CABIN X1 FILTER
-DI1
-DI2
DIGITAL INPUT
120VAC INPUT UNIT, 4CH
ALL.1734-IA4 6
L606686 L1
/18.4
0
Spare N32[0].4
7
L1
1
Spare N32[0].5
4
L1
2
Spare N32[0].6
5
L1
3
Spare N32[0].7
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B 02.11.2017 CAW REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Input modules DI1 and DI2 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X1 OU750007183 Page 20
0 1 2 3 4 5 6 7 8 9
-DI3
7
24VDC
5
0VDC
2
SpareN32[0].10
3
SpareN32[0].11
-DI4 0 1 1
DIGITAL INPUT UNIT
ALL.1734-IB4
-S755
6 295300-HY002-M/A 2
L40406 SWITCH (ELEC.)
/19.4
24VDC
TEL.XB4 BJ21
4 L22112
0VDC
21
-FDC2
/8.1 22
7
24VDC
5
0VDC
2
SpareN32[0].14
3
SpareN32[0].15
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Input modules DI3 and DI4 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X1 OU750007183 Page 21
0 1 2 3 4 5 6 7 8 9
1+
BN
WH OUT
+PF1200+X3.1-CWS104
Pressing water outlet HUM.HSK-K M16x1,5 (4-8)
-
valve AV04 closed S204 1 2 -S204
4 4 WH
N32[0].17 +
2-
7 2+
24VDC
5
Pressing water level 0VDC +PF1200+F1-WS516
1 3
low S516 2 3 DIRECT M12, 4-PIN, 10M +PF1200+F1-S516
5 5 IFM.EVT002 BK BU 295300-LS-630F
N32[0].18 L18121 + -
CAPACITIVE SWITCH
3- KIE3015-FPKG/US-100-DPS
BU BN
IFM.KI5052
3+ +PF1200+X3.1-CWS516 51717
BN BK 4
HUM.HSK-K M16x1,5 (4-8)
6
8 WH
Pressing water filling
WH OUT
valve AV13 closed S213 1 6-
8
N32[0].21
-
6+ -S213
+
7 9
7
24VDC
5 7-
0VDC
Spare
2 9
7+
N32[0].22
8
10
++X3.1-X3:14- 8-
31.4
Spare
3 10
8+
N32[0].23
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Input modules DI5 and DI6 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X1 OU750007183 Page 22
0 1 2 3 4 5 6 7 8 9
++X5-F51:2
++X5-DC.X5:0VDC
Spare
1
N32[0].25
+PF1200+F1-WS410
3x1
-X5 Specified by HU manufacturer
7 4
1
1 1
24VDC
+PF1200+F1-W205 1 +PF1200+F1-S410
5 1-
0VDC /9.5 P 295300-PS-632F
Oil filter clogged S410 +PF1200+X5-CWS410 Specified by HU manufacturer
2 4
1+
2 2
2
N32[0].26 HUM.HSK-K M16x1,5 (4-8)
+PF1200+F1-WS601
3x1
Specified by HU manufacturer
2
5 1 1
1 +PF1200+F1-S601
11
Protector for R04 oil 2-
295300-TS-630F
T
temperature switch +PF1200+X5-CWS601 12
Specified by HU manufacturer
3 2+ 2
S601 N32[0].27 5 2 HUM.HSK-K M16x1,5 (4-8) 2
-DI8
DIGITAL INPUT UNIT
ALL.1734-IB4 +PF1200+CUSTOMER-WS901
UNIKA.UNIDRALL 2500 UL 3G1 1
L40406 6 1 1
1
/19.5
24VDC
+PF1200+F1-S901
Gland seal flow sensor 4 295300-FSL-688
0VDC
for Feed pump -CWS901
Specified by mechanical designer
0 2 4
295300-PP-088 N32[0].28 2 HUM.HSK-K M16x1,5 (4-8) 2
+PF1200+CUSTOMER-WS902
UNIKA.UNIDRALL 2500 UL 3G1 1
1
1 1
+PF1200+F1-S902
Gland seal flow sensor 295300-FSL-689
for Feed pump -CWS902
Specified by mechanical designer
1 2 4
295300-PP-089 N32[0].29 2 HUM.HSK-K M16x1,5 (4-8) 2
+PF1200+CUSTOMER-WS905
UNIKA.UNIDRALL 2500 UL 3G1 1
7 1 1
1
24VDC
+PF1200+F1-S905
Gland seal flow sensor 5 295300-FSL-634F
0VDC
for Manifold flush -CWS905
Specified by mechanical designer
2 2 4
pump 295300-PP-035 N32[0].30 2 HUM.HSK-K M16x1,5 (4-8) 2
+PF1200+CUSTOMER-WS906
UNIKA.UNIDRALL 2500 UL 3G1 1
1
1 1
+PF1200+F1-S906
Gland seal flow sensor 295300-FSL-635F
for Manifold flush -CWS906
Specified by mechanical designer
3 2 4
pump 295300-PP-036 N32[0].31 2 HUM.HSK-K M16x1,5 (4-8) 2
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B 02.11.2017 CAW REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Input modules DI7 and DI8 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X1 OU750007183 Page 23
0 1 2 3 4 5 6 7 8 9
-XCR.1
1
Spare
1 2
N32[1].1
7
24VDC
5
0VDC
Spare
2 3
N32[1].2
Spare
3 4
N32[1].3
-DI10
DIGITAL INPUT UNIT
ALL.1734-IB4
L40406 6
/19.6
24VDC
4
0VDC
Spare
0 5
N32[1].4
Spare
1 6
N32[1].5
7
24VDC
5
0VDC
Spare
2 7
N32[1].6
Spare
3 8
N32[1].7
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Input modules DI9 and DI10 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X1 OU750007183 Page 24
0 1 2 3 4 5 6 7 8 9
Spare
1 10
N32[1].9
7
24VDC
5
0VDC
Spare
2 11
N32[1].10
Spare
3 12
N32[1].11
-DI12
DIGITAL INPUT UNIT
ALL.1734-IB4
L40406 6
/19.6
24VDC
4
0VDC
Spare
0 13
N32[1].12
Spare
1 14
N32[1].13
7
24VDC
5
0VDC
Spare
2 15
N32[1].14
Spare
3 16
N32[1].15
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Input modules DI11 and DI12 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X1 OU750007183 Page 25
0 1 2 3 4 5 6 7 8 9
Spare
1 18
N32[1].17
7
24VDC
5
0VDC
Spare
2 19
N32[1].18
Spare
3 20
N32[1].19
-DI14
DIGITAL INPUT UNIT
ALL.1734-IB4
L40406 6
/19.7
24VDC
4
0VDC
Spare
0 21
N32[1].20
Spare
1 22
N32[1].21
7
24VDC
5
0VDC
Spare
2 23
N32[1].22
Spare
3 24
N32[1].23
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Input modules DI13 and DI14 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X1 OU750007183 Page 26
0 1 2 3 4 5 6 7 8 9
Spare
1 26
N32[1].25
7
24VDC
5
0VDC
Spare
2 27
N32[1].26
Spare
3 28
N32[1].27
-DI16
DIGITAL INPUT UNIT
ALL.1734-IB4
L40406 6
/19.8
24VDC
4
0VDC
Spare
0 29
N32[1].28
Spare
1 30
N32[1].29
7
24VDC
5
0VDC
Spare
2 31
N32[1].30
Spare
3 32
N32[1].31
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Input modules DI15 and DI16 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X1 OU750007183 Page 27
0 1 2 3 4 5 6 7 8 9
Spare
1 34
N32[2].1
7
24VDC
5
0VDC
Spare
2 35
N32[2].2
Spare
3 36
N32[2].3
-DI18
DIGITAL INPUT UNIT
ALL.1734-IB4
L40406 6
/19.8
24VDC
4
0VDC
Spare
0 37
N32[2].4
Spare
1 38
N32[2].5
7
24VDC
5
0VDC
Spare
2 39
N32[2].6
Spare
3 40
N32[2].7
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Input modules DI17 and DI18 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X1 OU750007183 Page 28
0 1 2 3 4 5 6 7 8 9
Spare
1 42
N32[2].9
7
24VDC
5
0VDC
Spare
2 43
N32[2].10
Spare
3 44
N32[2].11
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Input module DI19 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X1 OU750007183 Page 29
0 1 2 3 4 5 6 7 8 9
-DO1
Alarm acknowledge 2
push button indicator N33[0].2
light H733 yellow
-H733
4
0VDC
3
Spare N33[0].3
5
0VDC
-DO2
OUTPUT UNIT
ALL.1734-OB4E
L09212 0
/18.1 Total cycle counter C1 N33[0].4 -C1
COUNTER
KÜB.1.130.000.033 C
6 L28453
0VDC
1
Alarm beacon H1 N33[0].5
X1
-H1
ALARM BEACON
7 ALL.855T-B24BR5 X2
0VDC L09486
2
Spare N33[0].6
4
0VDC
3
Spare N33[0].7
5
0VDC
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Output modules DO1 and DO2 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X1 OU750007183 Page 30
0 1 2 3 4 5 6 7 8 9
6
0VDC
+PF1200+X3.1 +PF1200+X3.2
22.4 +PF1200+F1-W203.2 -W203.3
+PF1200+F1-W203.1 -X3 UNIKA.UNIDRALL 2500 UL 12G1
1 /9.2 13 5m CABLE WITH PLUG
15 15 2 26x0.34 BK 36
Spare N33[0].9 5m
2
-X3.2 WH VALVE BLOCK
13-
11
WH 1
7 PE
0VDC
1 BK
-
Pressing water outlet
2 14 2
valve AV04 control N33[0].10 16 16 3 BN
solenoid Y04 14- +PF1200+X3.1-CW203.2 3 BN -Y04
1 HUM.HSK-K M20X1,5 (6-12) 295300-FSV-635F
12 Specified by mechanical designer
4 PE
0VDC
-DO4
OUTPUT UNIT
ALL.1734-OB4E
L09212 0
/18.2 Spare N33[0].12
6
0VDC
1
Spare N33[0].13
7
0VDC
2
Spare N33[0].14
4
0VDC
3
Spare N33[0].15
5
0VDC
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Output modules DO3 and DO4 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X1 OU750007183 Page 31
0 1 2 3 4 5 6 7 8 9
5.8 5.9
-DO5 CONTROL CABIN X1 FILTER
-N:5
DIGITAL OUTPUT UNIT 295300-PLC-002
+PF1200+CUSTOMER-WHV-610
ALL.1734-OW2 -X120
L40407 N33[0].16 0 2
2 1
/18.2 A1 +PF1200+CUSTOMER-HV-610
Manifold flush tank PE
GNYE GNYE
PE 295300-HV-620
TK-010 filling valve -X120 -CWHV-610 120VAC
2 1
1 2 A2
HUM.HSK-K M16x1,5 (4-8)
+PF1200+CUSTOMER-WHV-611
-X120
N33[0].17 1 4
2 1
A1 +PF1200+CUSTOMER-HV-611
Cloth wash tank TK-011 PE
GNYE GNYE
PE 295300-HV-621
filling valve -X120 -CWHV-611 120VAC
3 3
1 2 A2
HUM.HSK-K M16x1,5 (4-8)
-DO6
DIGITAL OUTPUT UNIT
ALL.1734-OW2 N33[0].18 0
L40407
/18.3
Spare
2
N33[0].19 1
Spare
3
-DO7
DIGITAL OUTPUT UNIT
ALL.1734-OW2
L40407 N33[0].20 0
/18.3
Spare
2
N33[0].21 1
Spare
3
-DO8
DIGITAL OUTPUT UNIT
ALL.1734-OW2 N33[0].22 0
L40407
/18.5
Spare
2
N33[0].23 1
Spare
3
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B 02.11.2017 CAW REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Output modules DO5, DO6, DO7 and DO8 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X1 OU750007183 Page 32
0 1 2 3 4 5 6 7 8 9
Spare
2
N33[0].25 1
Spare
3
-DO10
DIGITAL OUTPUT UNIT
ALL.1734-OW2 N33[0].26 0
L40407
/18.6
Spare
2
N33[0].27 1
Spare
3
-DO11
DIGITAL OUTPUT UNIT
ALL.1734-OW2
L40407 N33[0].28 0
/18.6
Spare
2
N33[0].29 1
Spare
3
-DO12
DIGITAL OUTPUT UNIT
ALL.1734-OW2 N33[0].30 0
L40407
/18.6
Spare
2
N33[0].31 1
Spare
3
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Output modules DO9, DO10, DO11 and Serial no = PF1200 Drawing number
REV. D REV. H APPR DO12 Location + PF1200+X1 OU750007183 Page 33
0 1 2 3 4 5 6 7 8 9
Spare
2
N33[1].1 1
Spare
3
-DO14
DIGITAL OUTPUT UNIT
ALL.1734-OW2 N33[1].2 0
L40407
/18.7
Spare
2
N33[1].3 1
Spare
3
-DO15
DIGITAL OUTPUT UNIT
ALL.1734-OW2
L40407 N33[1].4 0
/18.7
Spare
2
N33[1].5 1
Spare
3
-DO16
DIGITAL OUTPUT UNIT
ALL.1734-OW2 N33[1].6 0
L40407
/18.7
Spare
2
N33[1].7 1
Spare
3
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Output modules DO13, DO14, DO15 and Serial no = PF1200 Drawing number
REV. D REV. H APPR DO16 Location + PF1200+X1 OU750007183 Page 34
0 1 2 3 4 5 6 7 8 9
Spare
2
N33[1].9 1
Spare
3
-DO18
DIGITAL OUTPUT UNIT
ALL.1734-OW2 N33[1].10 0
L40407
/18.8
Spare
2
N33[1].11 1
Spare
3
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Output modules DO17 and DO18 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X1 OU750007183 Page 35
0 1 2 3 4 5 6 7 8 9
0VDC
4 3bu
21
2 2
- T Specified by HU manufacturer
22
2
GND
+PF1200+X5-CW205A
HUM.HSK-K M20X1,5 (6-12)
-CW205A +PF1200+X5-CWB601
HUM.HSK-K M20X1,5 (6-12) HUM.HSK-K M20X1,5 (6-12)
-AI2
ANALOG INPUT UNIT
+PF1200+F1-WB516
ALL. 1734-IE2C CEAM.LIYCY 2x2x0,5
603089 Pressing water level 0 15 m WH BN +PF1200+F1-B516
B516N35[16].x
+
/19.2 295300-LT-630F
0-2000 mm, 4-20 mA 24VDC 6 BN I PRESSURE TRANSMITTER
-CWB516
HUM.HSK-K M16x1,5 (4-8)
WH
- L ROS.2090PG 1S22A1
L01372
4
0VDC
2
GND
Spare 1
N35[17].x
7
24VDC
5
0VDC
3
GND
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B 02.11.2017 CAW REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Analog input modules AI1 and AI2 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X1 OU750007183 Page 36
0 1 2 3 4 5 6 7 8 9
15
16
1 2rd
Spare N35[21].x 17
2rd
7
18
2bu
5 2bu
0VDC 19
3
GND
-AO2
ANALOG OUTPUT UNIT
4-20/0-20mA
ALL. 1734-OE2C 0
615627 Spare N35[44].x
/19.2 6
24VDC
4
0VDC
2
GND
1
Spare N35[45].x
7
24VDC
5
0VDC
3
GND
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B 02.11.2017 CAW REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Analog output modules AO1 and AO2 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X1 OU750007183 Page 37
0 1 2 3 4 5 6 7 8 9
4
0VDC
2
GND
1
Spare N35[47].x
7
5
0VDC
3
GND
-AO4
ANALOG OUTPUT UNIT
4-20/0-20mA
ALL. 1734-OE2C 0
615627 Spare N35[48].x
/19.3 6
4
0VDC
2
GND
1
Spare N35[49].x
7
5
0VDC
3
GND
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B 02.11.2017 CAW REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Analog output modules AO3 and AO4 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X1 OU750007183 Page 38
0 1 2 3 4 5 6 7 8 9
3
3 3
Hydraulic unit cooler 3
M05 -KA110
295300-HY-002B 24 23 4
4 4
4
/11.1
5
5 5
Hydraulic unit heater 5
R04 -KA110
295300-HY-003 34 33 6
6 6
6
/11.1
7
7 7
7
Spare -KA111
64 63 8
8 8
8
/11.5
-CW801
HUM.HSK-K M40X1,5 (22-32)
9
9 9
Pressing water pump 9
M02.1 -KA111.3
295300-PP-033 14 13 10
10 10
10
/13.1
11
11 11
Pressing water pump 11
M02.2 -KA111.3
295300-PP-034 24 23 12
12 12
12
/13.1
13
13 13
Manifold flush pump 13
M15.1 -KA111
295300-PP-035 14 13 14
14 14
14
/11.5
15
15 15
Manifold flush pump 15
M15.2 -KA111
295300-PP-036 24 23 16
16 16
16
/11.5
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Emergency stop contacts for motors Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X1 OU750007183 Page 39
0 1 2 3 4 5 6 7 8 9
19 19
19 19
Cloth wash pump
M06.2 -KA111
295300-PP-038 44 43 20 20
20 20
/11.5
21 21
21 21
Slurry feed pump
M11.1 -KA111.1
295300-PP-088 14 13 22 22
22 22
/12.1
23 23
23 23
Slurry feed pump
M11.2 -KA111.1
295300-PP-089 24 23 24 24
24 24
/12.1
25 25
25 25
Lump breaker M08.1
start forward -KA111.1
295300-RB-001 34 33 26 26
26 26
/12.1
27 27
27 27
Lump breaker M08.1
start reverse -KA111.1
295300-RB-001 44 43 28 28
28 28
/12.1
29 29
29 29
Lump breaker M08.2
start forward -KA111.1
295300-RB-002 64 63 30 30
30 30
/12.1
31 31
31 31
Lump breaker M08.2
start reverse -KA111.1
295300-RB-002 74 73 32 32
32 32
/12.1
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Emergency stop contacts for motors Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X1 OU750007183 Page 40
0 1 2 3 4 5 6 7 8 9
35 35
35 35
Lump breaker M08.3
start reverse -KA111.1
295300-RB-003 94 93 36 36
36 36
/12.1
37 37
37 37
Lump breaker M08.4
start forward -KA111.2
295300-RB-004 14 13 38 38
38 38
/12.5
39 39
39 39
Lump breaker M08.4
start reverse -KA111.2
295300-RB-004 24 23 40 40
40 40
/12.5
41 41
41 41
Chute slide gate
MV08.1 open -KA111.2
295300-CH-001 34 33 42 42
42 42
/12.5
43 43
43 43
Chute slide gate
MV08.1 close -KA111.2
295300-CH-001 44 43 44 44
44 44
/12.5
45 45
45 45
Chute slide gate
MV08.2 open -KA111.2
295300-CH-003 64 63 46 46
46 46
/12.5
47 47
47 47
Chute slide gate
MV08.2 close -KA111.2
295300-CH-003 74 73 48 48
48 48
/12.5
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Emergency stop contacts for motors Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X1 OU750007183 Page 41
0 1 2 3 4 5 6 7 8 9
-X2
RIT.AE 1016.600 PF1200
X2
150
L605365
L39332
295300-JB S711
EMERGENCY STOP
S711
KA102
S711
FDC21
FDC22
PE
PE
T2
PE
PE
PE
PE
PE
PE
PE
PE
1
2
3
AC.X2 FAC2* N FDC* DC1 F2* DC2 F28
X8.1
PE
PE
PE
PE
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
1
2
3
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
DC.X12 X8.2 X8.6 9 X207
I/O- MODULES
DI DI DI DI DI DI DI DI DI DI DI DI DO DO DO DO DO DO DO DO AI AI AI AI INC AO
DUMMY 1
DUMMY 2
DUMMY 3
1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 1 2 3 4 1 1
PE FE
800x1000x300 mm
MATERIAL: AISI304, IP66
Ø2
8x
FAC2* = AUTOMATIC FUSE 120VAC
N = NEUTRAL FOR 120VAC
75
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X2
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Lay-out, terminal box X2 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X2 OU750007183 Page 1
0 1 2 3 4 5 6 7 8 9
-N:1
3.0
ASSEMBLY BOX
PLATE FRAME COVER
-AC.X2 1L 2N PE PE PE
295300-JB
TERMINAL BOX X2
FILTER
1 2 GNYE
-CW202
HUM.HSK-K M20X1,5 (6-12)
+PF1200+CUSTOMER-W202
++F1-PE1
++X1/5.7
++X1/5.7 ++F1/8.1
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X2
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Voltage distribution, 120VAC Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X2 OU750007183 Page 2
0 1 2 3 4 5 6 7 8 9
-AC.X2:2N
2.9
-N 1 2 3
1 1 1
-FAC21 -FAC22 -FAC23
AUTOMATIC FUSE 2 AUTOMATIC FUSE 2 AUTOMATIC FUSE 2
AUTOMAT. SINGLE-POLE C 6 A AUTOMAT. SINGLE-POLE C 4 A AUTOMAT. SINGLE-POLE C 2 A
SIE.5SY4 106-7 SIE.5SY4 104-7 SIE.5SY4 102-7
L08722 L08721 L08720
L PE N
-T2
POWER SUPPLY UNIT
IFM.DN4013 -PE
115/230VAC / 24VDC / 10A DC ok
L50833
+ + - -
-FDC22:1
-FDC21:1
-DC1:1-
4.0
4.0
4.0
295300-JB
TERMINAL BOX X2
FILTER
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X2
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Voltage distribution, 120VAC Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X2 OU750007183 Page 3
0 1 2 3 4 5 6 7 8 9
1 13 21
-FDC22
AUTOMATIC FUSE 2 14 22
1 AUTOMAT. SINGLE-POLE C 6 A
/17.3
SIE.5SY4 106-7
-FDC21 L08722
AUTOMATIC FUSE 2
AUTOMAT. SINGLE-POLE C 6 A
SIE.5SY4 106-7
L08722
13 23
-KA102
/5.2 14 24
-DC1 1 2 3 4 5 6 7 8 9
-DC2 21 22 23 24 25 26 27
-DC.X12:DC1
-X207:16
12.5 6.3
1
1 1 1 1 1 1 -F28
AUTOMATIC FUSE 2
-F21 -F22 -F23 -F24 -F25 -F26 AUTOMAT. SINGLE-POLE C 4 A
AUTOMATIC FUSE 2 AUTOMATIC FUSE 2 AUTOMATIC FUSE 2 AUTOMATIC FUSE 2 AUTOMATIC FUSE 2 AUTOMATIC FUSE 2
AUTOMAT. SINGLE-POLE C 1 A AUTOMAT. SINGLE-POLE C 1 A AUTOMAT. SINGLE-POLE C 1 A AUTOMAT. SINGLE-POLE C 1 A AUTOMAT. SINGLE-POLE C 4 A AUTOMAT. SINGLE-POLE C 1 A
SIE.5SY4 104-7
SIE.5SY4 101-7 SIE.5SY4 101-7 SIE.5SY4 101-7 SIE.5SY4 101-7 SIE.5SY4 104-7 SIE.5SY4 101-7 L08721
L08719 L08719 L08719 L08719 L08721 L08719
-DUMMY1:6
-DUMMY2:6
-DUMMY3:6
-X8.6:1+
-BK1:6
14.4
14.0 14.6 9.1 14.7
-DUMMY2:4
-DUMMY3:4
-DUMMY1:4
-KA102:A2
-X8.6:1-
-INC1:5
-INC1:1
-BK1:4
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X2
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Voltage distribution, 24VDC Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X2 OU750007183 Page 4
0 1 2 3 4 5 6 7 8 9
4.3
7.2
7.2
-X8.1:3
-DC1:6-
-X8.1:2
-X8.1:1
-KA102 A1 A2 Y1 Y2 13 23 33 43
SAFETY RELAY
EXPANDER MODULE
PILZ.PZEX 4P
Switching capacity in
L06522
accordance with EN60947-4-1 K1
13 14 /4.7
23 24 /4.7
240V / 6A / 1500VA
33 34 24V / 6A / 150W
43 44
Contact fuse protection 6A K2
quick / 4A slow
14 24 34 44
295300-JB
TERMINAL BOX X2
FILTER
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X2
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Emergency stop relay KA102 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X2 OU750007183 Page 5
0 1 2 3 4 5 6 7 8 9
-DC1:4-
-DC1:4
-DC.X12 0VDC DC1 PE
+PF1200+F1-W212
UNIKA.UNIDRALL 2500 UL 18G1
10 m
2 1 GNYE
-CW212
HUM.HSK-K M25x1,5 (13-18)
+PF1200+X12
-CW212
HUM.HSK-K M25x1,5 (13-18)
GNYE 2 1
-DC.X12
DC1
0VDC
PE
1
-F121
AUTOMATIC FUSE 2
AUTOMAT. SINGLE-POLE C 1 A
SIE.5SY4 101-7
++X12-X12:1+
++X12-X12:1-
L08719
18.5 18.5
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X2
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Voltage distribution for terminal box X12 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X2 OU750007183 Page 6
0 1 2 3 4 5 6 7 8 9
-X207:14
-X207:3
+DOOR
11 21
-S711
BUTTON
emergency stop 12 22
pushbutton
TEL.XB4-BS8445
L04494
8.3 8.3 8.6 5.3 5.3 5.2 9.2 11.8 11.8 9.8 9.8 12.2 12.4 12.5 12.5 12.4 12.4 12.6 12.5 12.6
-KA102:A1
-KA102:Y2
-KA102:Y1
-X8.6:11+
-X207:15
-X207:17
-X207:18
-X207:10
-X207:11
-X207:24
-X207:20
-X207:22
-X8.6:19
-X8.6:29
-X8.6:13
-X8.6:23
-X207:4
-X8.2:1
-X8.2:2
-X8.2:6
PE
-X8.1 1 2 3 PE
295300-JB
TERMINAL BOX X2
FILTER
1 2 3 4 5 6 7 8 9 10 11 GNYE 1 2 3 4 5 6 7 8 9 10 11 GNYE
-CW802 -CW811
HUM.HSK-K M25X1,5 (9 - 16) HUM.HSK-K M25X1,5 (9 - 16)
+PF1200+CUSTOMER-W802 +PF1200+CUSTOMER-W811
++X1/15.1 ++X1/15.5
++X1/15.2 ++X1/15.7
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X2
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation External cables Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X2 OU750007183 Page 7
0 1 2 3 4 5 6 7 8 9
++X1-X8.2:2
-DO7:0
-DO7:6
++X1-X8.2:3
-DO7:1
-DO7:7
295300-JB
-X8.2 1 2 3 4 5 6 7 8
TERMINAL BOX X2
FILTER
+PF1200+F1-WS741 +PF1200+F1-WS742
UNIKA.UNIDRALL 2500 UL 5G1 UNIKA.UNIDRALL 2500 UL 5G1
1 2 3 4 1 2 3 4
5m 5m
-CWS741 -CWS742
HUM.HSK-K M20X1,5 (6-12) HUM.HSK-K M20X1,5 (6-12)
1 2 3 4 1 2 3 4
+PF1200+F1 +PF1200+F1
13 ACKNOWLEDGE 13 ACKNOWLEDGE
-S741 -H741 PUSH BUTTON -S742 -H742 PUSH BUTTON
BUTTON 14 BUTTON 14
TEL.XB4-BW36B5
FOR DOOR TEL.XB4-BW36B5
FOR DOOR
L14553 SWITCHES L14553 SWITCHES
LEFT SIDE RIGHT SIDE
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X2
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation External cables Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X2 OU750007183 Page 8
0 1 2 3 4 5 6 7 8 9
-DC1:3-
-DI3:0
++X1-X8.2:7
-DI3:1
-DI3:2
++X1-X8.2:10
++X1-X8.2:11
-X8.6:14+
10.0
-X8.6:4+
10.0
-X8.6:4-
10.0
295300-JB
-X8.6 1+ 1- 1 11+ 11- 11 21+ 21- 21 2+ 2- 2 12+ 12- 12 22+ 22- 22 3+ 3- 3 13+ 13- 13 23+ 23- 23
TERMINAL BOX X2
FILTER
BU BN GY PK GN WH YE BU BN GY PK GN WH YE BU BN GY PK GN WH YE
7 2 5 6 3 1 4 7 2 5 6 3 1 4 7 2 5 6 3 1 4
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X2
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation External cables Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X2 OU750007183 Page 9
0 1 2 3 4 5 6 7 8 9
-DI4:0
-DI4:1
-X8.6:17+
11.0
-X8.6:21+ -X8.6:27+
9.9 11.0
-X8.6:3+ -X8.6:7+
9.9 11.0
-X8.6:23- -X8.6:7-
9.9 11.0
295300-JB
-X8.6 4+ 4- 4 14+ 14- 14 24+ 24- 24 5+ 5- 5 15+ 15- 15 25+ 25- 25 6+ 6- 6 16+ 16- 16 26+ 26- 26
TERMINAL BOX X2
FILTER
BU BN GY PK GN WH YE BU BN GY PK GN WH YE BU BN GY PK GN WH YE
7 2 5 6 3 1 4 7 2 5 6 3 1 4 7 2 5 6 3 1 4
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X2
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation External cables Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X2 OU750007183 Page 10
0 1 2 3 4 5 6 7 8 9
++X1-X8.2:8
++X1-X8.2:9
-DI4:2
-X8.6:16
10.9
-X8.6:26
10.9
-X8.6:6+
10.9
-X8.6:26-
10.9
295300-JB
-X8.6 7+ 7- 7 17+ 17- 17 27+ 27- 27 8+ 8- 8 18+ 18- 18 28+ 28- 28 9+ 9- 9 19+ 19- 19 29+ 29- 29
TERMINAL BOX X2
FILTER
+PF1200+F1-WS807
10 M CABLE M12 WITH STRAIGHT PLUG
PILZ.540 321
BN BU GY PK GN WH YE
L27146
-CWS807
HUM.HSK-K M16x1,5 (4-8)
BU BN GY PK GN WH YE
7 2 5 6 3 1 4
+PF1200+F1-S807 A2 A1
295300-ZSC-643F S11 S21
PROTECTIVE LIMIT
PILZ.PSEN CS1.1P (540000)
L15392 Y32 12 22
DOOR SWITCH
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X2
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation External cables Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X2 OU750007183 Page 11
0 1 2 3 4 5 6 7 8 9
24.3
15.3
15.3
15.3
15.3
15.3
15.3
24.3
24.3
7.6
7.7
7.7
7.6
7.6
4.1
7.6
7.7
7.7
7.7
7.7
-DO7:4
-DI1:6
-S711:11
++X1-X8.5:2
-DI1:0
-DI1:1
-DI1:2
-DI1:3
-DI2:0
++X1-X8.5:7
++X1-X8.5:8
-DO7:2
-DO7:3
-S711:21
++X1-X8.5:4
-DC1:2
++X1-X8.5:5
++X1-X8.5:6
++X1-X8.5:10
++X1-X8.5:11
++X1-X8.5:9
++F1-X209:PE
13.6
++F1-X209:23
13.6
++F1-X209:22
13.6
++F1-X209:21
13.6
++F1-X209:20
13.5
++F1-X209:19
13.5
++F1-X209:18
13.5
++F1-X209:17
13.5
++F1-X209:16
13.5
++F1-X209:15
13.4
++F1-X209:14
13.4
++F1-X209:13
13.4
++F1-X209:12
13.4
++F1-X209:11
13.4
++F1-X209:10
13.4
++F1-X209:9
13.3
++F1-X209:8
13.3
++F1-X209:7
13.3
++F1-X209:6
13.3
++F1-X209:5
13.3
++F1-X209:4
13.2
++F1-X209:3
13.2
++F1-X209:2
13.2
++F1-X209:1
13.2
295300-JB
-X207 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 PE PE
TERMINAL BOX X2
FILTER
+PF1200+F1-W208
UNIKA.UNIDRALL 2500 UL 25G1
10 m
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 GNYE
-CW208
HUM.HSK-K M25x1,5 (13-18)
/19.3 +PF1200+F1-CX208
HUM.HSK-K M32X1,5 (13-20)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 GNYE
+PF1200+F1-X208 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 PE
+PF1200+F1-X790 1 2 3 4 5 6
+PF1200+F1-W790
UNIKA.UNIDRALL 2500 UL 5G1
1 2 3 4
2m
+PF1200+F1-CW790
HUM.HSK-K M20X1,5 (6-12)
1 2 3 4
+PF1200+F1-S790
ENABLE SWITCH 3 5
1
OMR.A4EG-C00041
L27352
2 4 6
ENABLE SWITCH
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X2
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation External cables Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X2 OU750007183 Page 12
0 1 2 3 4 5 6 7 8 9
-X207:2
-X207:3
-X207:4
-X207:5
-X207:6
-X207:7
-X207:8
-X207:9
-X207:10
-X207:11
-X207:12
-X207:13
-X207:14
-X207:15
-X207:16
-X207:18
-X207:19
-X207:20
-X207:21
-X207:22
-X207:23
-X207:24
-X207:PE
295300-JB
TERMINAL BOX X2
FILTER
+PF1200+F1-W209
UNIKA.UNIDRALL 2500 UL 25G1
3m
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 GNYE
-CW209
HUM.HSK-K M25x1,5 (13-18)
+PF1200+F1-CX209
HUM.HSK-K M32X1,5 (13-20)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 GNYE
+PF1200+F1-X209 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 PE
+PF1200+HH_U-W207
SAB.S 970 HP 18X0.75 AWG19
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 GNYE
3m
+PF1200+HH_U-CX207
HUM.HSK-K M25X1,5 (9 - 16)
+PF1200+HH_U-CHHC1
SKI.BS-BS-M 25*1.5 (11-21)
3 14 15 4 2 5 6 7 8 9 10 11 12 13 1
+PF1200+HH_U-HHC1
TERM.BOX TO HAND-H.
ROSE.29.500100 11 21 1...24 1 3 9 11 19 13 13
51521 -S702 -S714 -S723 -S725 -H723 -H725
BUTTON 12 22 SWITCH 2 4 10 12 20 TEL.XB4-BW33B5 14 TEL.XB4 BW31B5 14
TEL.XB4-BS8445 KRA.A11-1 L04491 L04492
L04494 9391
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X2
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation External cables Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X2 OU750007183 Page 13
14
-AO1
OU750007183 Page
ALL. 1734-OE2C
9
-INC1
Drawing number
Project number
COUNTER
DQ-160271
ALL.1734-IK
-AI4
ANALOG INPUT UNIT
ALL. 1734-IE2C
-AI3
ANALOG INPUT UNIT
PF 7.9/12.6 M1.6 1 45
ALL. 1734-IE2C
-AI2
+ PF1200+X2
ALL. 1734-IE2C
= PF1200
-AI1
ANALOG INPUT UNIT
ALL. 1734-IE2C
POWER FEED UNIT
-DUMMY3
Filter type
-DC1:7-
ALL.1734-FPD
Serial no
Location
4.3
L40408
4
PE
2
-F26:2
4.6
6
-DO8
7
OUTPUT UNIT
Bus coupler and I/O-modules voltage
ALL.1734-OB4E
-DO7
OUTPUT UNIT
ALL.1734-OB4E
POWER FEED UNIT
-DUMMY2
-DC1:5-
ALL.1734-FPD
4.2
L40408
4
PE
2
-F23:2
4.3
6
Page description
6
-DO6
distribution
OUTPUT UNIT
ALL.1734-OB4E
-DO5
OUTPUT UNIT
ALL.1734-OB4E
-DO4
OUTPUT UNIT
ALL.1734-OB4E
-DO3
OUTPUT UNIT
5
ALL.1734-OB4E
-DO2
OUTPUT UNIT
ALL.1734-OB4E
-DO1
OUTPUT UNIT
ALL.1734-OB4E
POWER FEED UNIT
-DUMMY1
-DC2:22-
ALL.1734-FPD
PE
2
-F28:2
4.8
6
4
-DI12
DIGITAL INPUT UNIT
ALL.1734-IB4
-DI11
DIGITAL INPUT UNIT
ALL.1734-IB4
Customer name
-DI10
DIGITAL INPUT UNIT
ALL.1734-IB4
3
-DI9
DIGITAL INPUT UNIT
ALL.1734-IB4
20/01/2017
-DI8
DIGITAL INPUT UNIT
ALL.1734-IB4
CAW
CXZ
-DI7
DIGITAL INPUT UNIT
ALL.1734-IB4
DATE
APPR
DRN
CHD
-DI6
DIGITAL INPUT UNIT
ALL.1734-IB4
2
X
-DI5
DIGITAL INPUT UNIT
ALL.1734-IB4
FOR APPROVAL
PRELIMINARY
-DI4
CERTIFIED
DIGITAL INPUT UNIT
ALL.1734-IB4
-DI3
DIGITAL INPUT UNIT
ALL.1734-IB4
-DI2
1
H
G
E
F
REV.
REV.
REV.
REV.
COMMUNICATION MODULE
ETHERNET, POINT I/O
-DC1:2-
ALL.1734-AENTR
4.1
04.09.2017 CAW
L39812
-BK1
PE
2
-F21:2
4.1
6
0
D
A
C
B
REV.
REV.
REV.
REV.
0 1 2 3 4 5 6 7 8 9
Test 1 -X207:6
selector switch S714 N32[20].1 12.3
binary 2
7
24VDC
5
0VDC
Test 2 -X207:7
selector switch S714 N32[20].2 12.3
binary 4
Test
selector switch S714 3 -X207:8
binary 8 N32[20].3 12.3
-DI2
DIGITAL INPUT UNIT
ALL.1734-IB4
L40406 6
/14.1
24VDC
4
0VDC
Test 0 -X207:9
selector switch S714 N32[20].4 12.3
binary 16
1
Spare N32[20].5
+PF1200+F1-W222 +PF1200+X22
7 /22.4
13
24VDC
5
0VDC
14 -WS418
Supplied by FESTO BN 1
2 13
-X22 BN
13
Spare N32[20].6 -S418
13 295300-PS-630F
14 BU BK 4 14
Supplied by FESTO
14
15 BK BU 3
15
Instrument air
pressure switch S418,
16
In pneumatic box X22 3 15
N32[20].7
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X2
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Input modules DI1 and DI2 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X2 OU750007183 Page 15
0 1 2 3 4 5 6 7 8 9
7
24VDC
5
0VDC
-DI4
DIGITAL INPUT UNIT
ALL.1734-IB4
L40406 6
/14.1
24VDC
4
0VDC
7
24VDC
5
0VDC
3
Spare N32[20].15
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X2
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Input modules DI3 and DI4 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X2 OU750007183 Page 16
0 1 2 3 4 5 6 7 8 9
21
-FDC22
Control voltage circuit /4.7 22
breaker tripped
(FDC22) 1
N32[20].17
+PF1200+F1-WS202
DIRECT M12, 4-PIN, 10M
1 3
7 BN BU
24VDC
IFM.EVT002
L18121
+PF1200+F1-S202
+ -
295300-ZSC-630F
Slurry feed inlet valve 5 BU BN INDUCTIVE SWITCH
0VDC
AV02 closed S202 IFM.IGT203
2 -CWS202 L07410
BK BK 4
N32[20].18 HUM.HSK-K M16x1,5 (4-8)
+PF1200+F1-WS205
DIRECT M12, 4-PIN, 10M
1 3
IFM.EVT002 BN BU +PF1200+F1-S205
L18121 + -
295300-ZSC-631F
Cake wash liquid inlet BU BN INDUCTIVE SWITCH
valve AV05 closed S205 IFM.IGT203
3 -CWS205 L07410
BK BK 4
N32[20].19 HUM.HSK-K M16x1,5 (4-8)
-DI6
DIGITAL INPUT UNIT
ALL.1734-IB4 +PF1200+F1-WS206
DIRECT M12, 4-PIN, 10M
1 3
L40406 6 BN BU
24VDC
IFM.EVT002
L18121
+PF1200+F1-S206
/14.2 + -
295300-ZSC-632F
Drying air inlet valve 4 BU BN INDUCTIVE SWITCH
0VDC
AV06 closed S206 IFM.IGT203
0 -CWS206 L07410
BK BK 4
N32[20].20 HUM.HSK-K M16x1,5 (4-8)
+PF1200+F1-WS207
DIRECT M12, 4-PIN, 10M
1 3
IFM.EVT002 BN BU +PF1200+F1-S207
L18121 + -
295300-ZSC-633F
Manifold drain outlet BU BN INDUCTIVE SWITCH
valve AV07 closed S207 IFM.IGT203
1 -CWS207 L07410
BK BK 4
N32[20].21 HUM.HSK-K M16x1,5 (4-8)
+PF1200+F1-WS209
DIRECT M12, 4-PIN, 10M
1 3
7 IFM.EVT002 BN BU
24VDC L18121 + -
1 3
-CWS209
HUM.HSK-K M16x1,5 (4-8)
+ -
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X2
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Input modules DI5 and DI6 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X2 OU750007183 Page 17
0 1 2 3 4 5 6 7 8 9
5+
Spare
1
N32[20].29
7
24VDC
5
Spare 0VDC
2
N32[20].30
Spare
3
N32[20].31
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X2
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Input modules DI7 and DI8 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X2 OU750007183 Page 18
0 1 2 3 4 5 6 7 8 9
+PF1200+X8-CW208
HUM.HSK-K M25x1,5 (13-18)
+PF1200+X2-CW208
HUM.HSK-K M25x1,5 (13-18)
4+ +PF1200+X8-CWZS111.4 2
DIGITAL INPUT UNIT 1 2 4
HUM.HSK-K M16x1,5 (4-8)
ALL.1734-IB4
L40406 6 +PF1200+X8.1
/14.3
24VDC
+PF1200+CUSTOMER-W208.1 +PF1200+F1-WS141
Cake chute -001 flap 4 UNIKA.UNIDRALL 2500 UL 7G1
-X8.1 1 3
0VDC 5 1
free end open 7 1 1 BK BU
+ -
S141 0 7
+PF1200+F1-S141
N32[21].4 5- 2
2 2 BU BN 295300-ZS-647F
Specified by mechanical designer
5+ 3 +PF1200+X8.1-CWS141
3 3 BN BK 4
HUM.HSK-K M16x1,5 (4-8)
+PF1200+X8.1-CW208.1
HUM.HSK-K M20X1,5 (6-12)
+PF1200+X8-CW208.1
HUM.HSK-K M20X1,5 (6-12)
6 4
free end closed 8 4 4 BK BU
+ -
S241 1 8
+PF1200+F1-S241
N32[21].5 6- 5
5 5 BU BN 295300-ZS-648F
Specified by mechanical designer
6+ 6 +PF1200+X8.1-CWS241
6 6 BN BK 4
HUM.HSK-K M16x1,5 (4-8)
7 PE
24VDC
Cake chute -003 flap 5
drive end open 0VDC +PF1200+X8.2
S142 2 9
+PF1200+CUSTOMER-W208.2
-X8.2 +PF1200+F1-WS142 1 3
N32[21].6 7
UNIKA.UNIDRALL 2500 UL 7G1
1
9 1 1 BK BU
+ -
+PF1200+F1-S142
7- 2
2 2 BU BN 295300-ZS-649F
Specified by mechanical designer
7+ 3 +PF1200+X8.2-CWS142
3 3 BN BK 4
Cake chute -003 flap HUM.HSK-K M16x1,5 (4-8)
drive end closed
S242 3 10 +PF1200+F1-WS242 1 3
+PF1200+X8.2-CW208.2
HUM.HSK-K M20X1,5 (6-12)
+PF1200+X8-CW208.2
HUM.HSK-K M20X1,5 (6-12)
N32[21].7 8 4
10 4 4 BK BU
+ -
+PF1200+F1-S242
8- 5
5 5 BU BN 295300-ZS-650F
Specified by mechanical designer
8+ 6 +PF1200+X8.2-CWS242
6 6 BN BK 4
HUM.HSK-K M16x1,5 (4-8)
PE
20.5 20.5
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X2
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Input modules DI9 and DI10 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X2 OU750007183 Page 19
0 1 2 3 4 5 6 7 8 9
++X8-X8:8+
++X8-X8:8-
4
for M08.5 0VDC /19.3 +PF1200+CUSTOMER-WZS111.5
-X8 UNIKA.UNIDRALL 2500 UL 3G1 1
ZS111.5 0 11 11
9
2 1
1
N32[21].8
+PF1200+F1-ZS111.5
9-
295300-ZS-639F
Specified by mechanical designer
9+ +PF1200+X8-CWZS111.5 2
1 2 4
HUM.HSK-K M16x1,5 (4-8)
Spare
3
N32[21].11
-DI12
DIGITAL INPUT UNIT
ALL.1734-IB4
L40406 6
/14.4
24VDC
4
0VDC
Spare
0
N32[21].12
Spare
1
N32[21].13
7
24VDC
5
0VDC
Spare
2
N32[21].14
Spare
3
N32[21].15
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X2
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Input modules DI11 and DI12 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X2 OU750007183 Page 20
0 1 2 3 4 5 6 7 8 9
+PF1200+F1-WY52
MURR.7004-18021-476-1000
1 1 1
L17130
Quick action closingN33[20].1
A1 +PF1200+F1-Y52
cylinders
GNYE GNYE
downwards(Y52) PE PE 295300-FSV-638F
-CWY52 Specified by mechanical designer
7 2 2 A2
0VDC HUM.HSK-K M16x1,5 (4-8)
+PF1200+F1-WY91
MURR.7004-18021-476-1000
2 1 1
L17130
N33[20].2
Cloth drive forward A1 +PF1200+F1-Y91
control solenoid Y91 PE
GNYE GNYE
PE 295300-FSV-639F
-CWY91 Specified by mechanical designer
4 2 2 A2
0VDC HUM.HSK-K M16x1,5 (4-8)
+PF1200+F1-WY92
MURR.7004-18021-476-1000
3 1 1
L17130
N33[20].3
Cloth drive reverse A1 +PF1200+F1-Y92
control solenoid Y92 PE
GNYE GNYE
PE 295300-FSV-640F
-CWY92 Specified by mechanical designer
5 2 2 A2
0VDC HUM.HSK-K M16x1,5 (4-8)
DO2
OUTPUT UNIT
ALL.1734-OB4E
L09212 0
/14.5 N33[20].4
Spare
6
0VDC
1
N33[20].5
Spare
7
0VDC
2
N33[20].6
Spare
4
0VDC
+PF1200+F1-WY11
MURR.7004-18021-476-1000
3 1 1
L17130
N33[20].7
Hydraulic unit cooling A1 +PF1200+F1-Y11
Y11 PE
GNYE GNYE
PE 295300-FSV-641F
-CWY11 Specified by mechanical designer
5 2 2 A2
0VDC HUM.HSK-K M16x1,5 (4-8)
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X2
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Output modules DO1 and DO2 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X2 OU750007183 Page 21
0 1 2 3 4 5 6 7 8 9
4 4 GN GN 3
0VDC
3
6
0VDC
7 PK PK 6
Cake wash liquid inlet 1 7
N33[20].13 6 -Y05
valve AV05 control 295300-FSV-631F
solenoid Y05 Specified by mechanical designer
7
0VDC
8 BU BU 7
Drying air inlet valve 2 8
N33[20].14 7 -Y06
AV06 control solenoid 295300-FSV-632F
Y06 Specified by mechanical designer
4
0VDC
9 RD RD 8
Manifold drain outlet 3 9
N33[20].15 8 -Y07
valve AV07 control 295300-FSV-633F
solenoid Y07 Specified by mechanical designer
5
0VDC
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X2
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Output modules DO3 and DO4 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X2 OU750007183 Page 22
0 1 2 3 4 5 6 7 8 9
6
0VDC
2 12 12 WH/GN WH/GN 11
N33[20].18
Spare 11
BN/GN BN/GN 12
12
4 BK BK 36
0VDC
-
-
3
N33[20].19 -
Spare 37
GNYE GNYE VT VT
PE
PE
5
0VDC
PE
-DO6
OUTPUT UNIT
+PF1200+F1-WY521
ALL.1734-OB4E
MURR.7004-18021-476-1000
L09212 0 1 1
L17130
/14.6
Sealing pressure N33[20].20
A1 +PF1200+F1-Y521
release valve Y521 GNYE GNYE
PE PE 295300-FSV-642F
-CWY521 Specified by mechanical designer
6 2 2 A2
0VDC HUM.HSK-K M16x1,5 (4-8)
1
N33[20].21
Spare
7
0VDC
2
N33[20].22
Spare
4
0VDC
3
N33[20].23
Spare
5
0VDC
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X2
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Output modules DO5 and DO6 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X2 OU750007183 Page 23
0 1 2 3 4 5 6 7 8 9
-DO8
OUTPUT UNIT
ALL.1734-OB4E
L09212 0
/14.7 N33[20].28
Spare
6
0VDC
1
N33[20].29
Spare
7
0VDC
2
N33[20].30
Spare
4
0VDC
3
N33[20].31
Spare
5
0VDC
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X2
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Output modules DO7 and DO8 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X2 OU750007183 Page 24
0 1 2 3 4 5 6 7 8 9
+PF1200+F1-WB419
CEAM.LIYCY 2x2x0,5
Pressing manifold 1 L48773 WH BN +PF1200+F1-B419
N35[5].x +
pressure B419 10 m I 295300-PT-632F
0-20 bar, 4-20 mA 24VDC
7 BN
-CWB419
WH
- P PRESSURE TRANSMITTER
ROS.2090PG 3S22A2
HUM.HSK-K M16x1,5 (4-8) L01046
5
0VDC
3
GND
-AI2
ANALOG INPUT UNIT +PF1200+F1-WB452
ALL. 1734-IE2C IFM.EVT384
603089 Plate pack sealing 0 L600748 WH BN 1 +PF1200+F1-B452
N35[7].x 295300-PT-634F
/14.8 pressure B452
6
25 m L+
I PRESSURE TRANSMITTER
0-400 bar, 4-20 mA BN WH 2
24VDC -CWB452
HUM.HSK-K M16x1,5 (4-8)
OUT P 0...400 BAR
IFM.PT5400
4 L603541
0VDC
2
GND
+PF1200+F1-B505
295300-ZT-630F
FSG.SL3002-PK1023-GS80/F01
L07327
+PF1200+X12 +PF1200+F1-WB505
+PF1200+F1-W212 -X12A CEAM.LIYCY 2x2x0,5 BN 6
+
Plate pack position B505 1 9 10
1 10 m BN
0-2000 mm, 4-20 mAN35[14].x WH 1
7 -
10 11 2 WH
24VDC 2
2 YE YE
5 +PF1200+X12-CWB505 OUT -
11 9 3 GN
0VDC HUM.HSK-K M16x1,5 (4-8) 3
GN
3 PE OUT+
GND
PE
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B 02.11.2017 CAW REV. F FOR APPROVAL DRN CXZ DQ-160271 X2
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Analog input modules AI1 and AI2 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X2 OU750007183 Page 25
0 1 2 3 4 5 6 7 8 9
+PF1200+F1-WB921
IFM.EVT384
Cloth wash water flow 1 L600748 WH BN 1 +PF1200+F1-B921
N35[24].x + 295300-FT-630F
B921
7
25 m
2
I FLOW SENSOR
3...300 cm/s, 4-20 mA 24VDC
BN
-CWB921
WH
OUT IFM.SI5004
HUM.HSK-K M16x1,5 (4-8) L52386
0VDC
5 BU BU 3
- F
3
GND
-AI4
ANALOG INPUT UNIT
ALL. 1734-IE2C
603089 Spare 0
/14.8
N35[x].x
6 ++F1-B331:+
24VDC 27.3
4 ++F1-B331:-
0VDC 27.3
2
GND
+PF1200+F1-B503
295300-ZT-631F
FSG.PK-1023-003/90
L43949
+PF1200+X12 +PF1200+F1-WB503 6
+PF1200+F1-W212 -X12A CEAM.LIYCY 2x2x0,5 BN
+
Cloth edge position B503 1 12 13
4 10 m BN
0-90°, 4-20 mAN35[12].x WH 1
-
7 13 14 5 WH
24VDC YE 2
5 YE OUT -
5 +PF1200+X12-CWB503
14 12 6 GN HUM.HSK-K M16x1,5 (4-8)
0VDC GN 3
OUT+
3 PE
GND
PE
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B 02.11.2017 CAW REV. F FOR APPROVAL DRN CXZ DQ-160271 X2
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Analog input modules AI3 and AI4 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X2 OU750007183 Page 26
0 1 2 3 4 5 6 7 8 9
TERMINAL BOX X2 FILTER
-INC1
-B331
1 -AI4:6 RD BU 295300-ZS-630F
Aret 26.3 -
IMPULSE DETECTOR
PEP.10-11331A-5-Y126138 PN126138
RD
+ L06998
2 ROSA WH
B OUT, A
-CWB331
HUM.HSK-K M16x1,5 (4-8) ROSA
OUT, B
3 VT
Bret OUT, K0
4 -AI4:4 BU
26.3
Z
-DC1:9-
5
-DC1:8-
Zret
6 4.4
PE 4.4
7
PE
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X2
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Analog input module INC1 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X2 OU750007183 Page 27
0 1 2 3 4 5 6 7 8 9
TERMINAL BOX X2 FILTER
-AO1
1
Spare N35[x].x
7
24VDC
5
0VDC
3
GND
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X2
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Analog output module AO1 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X2 OU750007183 Page 28
0 1 2 3 4 5 6 7 8 9
S703
F31
.5
Ø2
40
0 .5 6
Ø2 Ø1
5.
x
5
2x 10
X3 DI/DO
DC.X3
0VDC
0VDC
DC1
30
15
18
PE
PE
PE
PE
14
17
12
13
16
19
20
11
10
6
3
7
8
1
2
4
5
45
Ø3
2.5
87
72
PE
34 40 40 40 40 40 26
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X3.1
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Lay-out, terminal box X3.1 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X3.1 OU750007183 Page 1
0 1 2 3 4 5 6 7 8 9
5 .5
Ø2
6.5
5
0. Ø1
Ø2 10
x
40
DC.X5 F51,F52 4x
40
35
60
60
45 35 40 40 40 40 50
X5 X5A (10...19) (20...25)
PE
10 x M16 + 4 x M20 + 1 x M25
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X5
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Lay-out, terminal box X5 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X5 OU750007183 Page 1
0 1 2 3 4 5 6 7 8 9
F121
.5
Ø2
40 . 5 6
20 Ø1
5.
Ø x
5
2x 10
DC.X12
0VDC
X12A
X12
DC1
PE
PE
PE
PE
PE
PE
PE
PE
3
1
2
4
5
1
2
2
3
4
5
5
6
30
45
Ø3
2.5
87
72
34 40 40 40 40 40 26
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X12
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Lay-out, terminal box X12 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X12 OU750007183 Page 1
0 1 2 3 4 5 6 7 8 9
35 mm 30 mm
100 mm
80 mm
60 mm
60 mm
10
11
12
13
14
X8
3
1
2
4
5
6
7
8
9
45 mm 85 mm 50 mm
PE
REV. A 04.09.2017 CAW REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271 X8
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Lay-out, terminal box X8 Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+X8 OU750007183 Page 1
0 1 2 3 4 5 6 7 8 9
Mounting
Manufacturer Designation Type number Outotec code Quantity
location:
ALLEN BRADLEY ETHERNET /IP TO PROBIBUS-PA LINKING DEVICE 1788-EN2PAR L605325 1 PF1200+X1
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Summarized parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 1
0 1 2 3 4 5 6 7 8 9
Mounting
Manufacturer Designation Type number Outotec code Quantity
location:
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Summarized parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 2
0 1 2 3 4 5 6 7 8 9
Mounting
Manufacturer Designation Type number Outotec code Quantity
location:
PILZ SAFETY RELAY PNOZ m1P ETH (773 103) L28574 1 PF1200+X1
PILZ SAFETY RELAY PNOZ MULTI BUS TERMINATOR (779 110) L28602 1 PF1200+X1
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Summarized parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 3
0 1 2 3 4 5 6 7 8 9
Mounting
Manufacturer Designation Type number Outotec code Quantity
location:
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Summarized parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 4
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 7
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 8
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 9
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 10
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 11
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 12
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 13
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 14
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 15
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 16
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 17
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 18
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 19
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 20
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 21
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 22
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 23
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 24
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 25
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 26
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 27
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 28
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 29
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 30
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 31
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 32
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 33
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 34
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 35
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 36
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 37
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 38
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 39
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 40
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 41
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 42
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 43
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 44
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 45
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 46
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 47
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 48
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 49
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 50
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 51
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 52
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 53
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 54
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 55
0 1 2 3 4 5 6 7 8 9
Mounting location Designation 1 (Aton description 1) Type number (aton description 3) Manufacturer Outotec order number
Device tag
Placement Designation 2 (description in eplan) Technical info (aton description 4) Remark Quantity
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Parts list Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+PARTS OU750007183 Page 56
0 1 2 3 4 5 6 7 8 9
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Cable overview Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+CABLES OU750007183 Page 1
0 1 2 3 4 5 6 7 8 9
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Cable overview Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+CABLES OU750007183 Page 2
0 1 2 3 4 5 6 7 8 9
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Cable overview Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+CABLES OU750007183 Page 3
0 1 2 3 4 5 6 7 8 9
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Cable overview Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+CABLES OU750007183 Page 4
0 1 2 3 4 5 6 7 8 9
REV. A REV. E PRELIMINARY DATE 20/01/2017 Customer name Page description Filter type PF 7.9/12.6 M1.6 1 45 Project number Location
REV. B REV. F FOR APPROVAL DRN CXZ DQ-160271
REV. C REV. G CERTIFIED X CHD CAW Southern Peru Copper Corporation Cable overview Serial no = PF1200 Drawing number
REV. D REV. H APPR Location + PF1200+CABLES OU750007183 Page 5