SIPROTEC 7KE85

Fault Recorder

www.siemens.com/siprotec

Description
Powerful fault recorders with integrated measurement of
synchrophasors (PMU) according to IEEE C37.118 and
power quality measurement according to IEC 61000-4-30.
Due to the great flexibility of trigger functions, the
SIPROTEC 7KE85 is ideally suited for monitoring the entire
energy value added chain, from generation to distribution.
The powerful automation and flexible configuration with
DIGSI 5 complements the range of functions.

Main function Fault Recorder

Inputs and 4 predefined standard variants with up to


outputs 40 current transformers and 40 voltage Fault recorder SIPROTEC 7KE85 (1/3 device with 1/6 expansion
transformers, 43 binary inputs, 33 binary
module and LED indications)
outputs

Hardware Flexibly adjustable and expandable I/O


flexibility quantity structure within the scope of the • Closing and breaking operations of transformers
SIPROTEC 5 modular system
(saturation response)
Housing width 1/3 to 1/1 x 19" • Power fluctuations and power-swing cycles
• Test runs during commissioning
Application Areas Functions
The fault recorder is for use in medium, high and extra- DIGSI 5 permits all functions to be configured and com-
high voltage systems and in power plants with compre- bined as required.
hensive trigger and recording functions. With the
SIPROTEC 7KE85 fault recorder, you receive a clearly orga- • Up to 40 analog channels
nized and event-related evaluation and documentation of • Fast-Scan Recorder
your power system processes. You are thereby able to • Up to 2 slow-scan recorders
analyze failures in a targeted manner and optimize your
• Up to 5 continuous recorders and 2 trend recorders
power system.
• Power quality recordings according to IEC 61000-4-30
Typical processes to be monitored and documented:
(harmonics, THD, TDD - in preparation)
• System incidents, such as critical load cases or short
• Sequence-of-events recorder for continuous recording
circuits
of binary status changes and IEC 61850 GOOSE
• Failures of the quality of supply messages
• Dynamic behavior of generators
Efficient and modular

• Usable as Phasor Measurement Unit (PMU) according • Trigger functions via a combination of single-point,
to IEEE C37.118 protocol doublepoint indications, analog values, binary signals,
Boolean signals and GOOSE messages
• Transmission of the records and triggering via
IEC 61850 GOOSE messages • Consistent monitoring concept
• Variable sampling frequencies parameterizable • Auxiliary functions for easy tests and commissioning
between 1 kHz and 16 kHz • Special test mode for commissioning
• Distribution of the mass storage of 16 GB to the • Integrated electrical Ethernet RJ45 for DIGSI 5 and
various recorders by the user as desired IEC 61850 (reporting and GOOSE)
• Intelligent monitoring routines of the storage medium • Redundancy protocols PRP and HSR
ensure a high level of availability and completeness • Cyber security to NERC CIP and BDWE Whitepaper
for the archived data requirements
• Lossless data compression
• Up to 4 pluggable communication modules usable for
• Time synchronization via Precision Time Protocol (PTP) different and redundant protocols
IEEE 1588 protocol, IRIG-B, DCF77, and SNTP
• Intelligent terminal technology enables prewiring and
• Routing of the measured values to the individual a simple device replacement
recorders as desired
Benefits
• Combination of the measuring groups for the power
calculation as desired • Clearly organized documentation and focused analysis
of power system processes and failures
• Quality attributes for representing the instantaneous
signal quality in the time signal view • Data security and transparency over the entire
lifecycle of the plant save time and money
• Trigger functions of a function block are fundamental
component value, RMS value, zero-sequence, positive- • Purposeful and simple operation of the devices and
sequence, negative-sequence system power, frequen- software thanks to user-friendly design
cy power, Σ activepower and Σ reactive power • Increased reliability and quality of the engineering
• Level trigger and gradient trigger for every trigger process
function • Powerful communication components ensure safe and
• Flexible cross trigger and system trigger, manual effective solutions
trigger • Full compatibility between IEC 61850 Editions 1
• Creation of independent trigger functions with the and 2
graphic automation editor CFC (continuous function • Highly available Ethernet communication due to inte-
chart) grated Ethernet redundancy protocols PRP and HSR

For all products using


security features of
Siemens AG OpenSSL, the
Energy Management Division following shall apply:
Freyeslebenstraße 1
This product includes
91058 Erlangen, Germany
software developed
by the OpenSSL
SIPROTEC 7KE85 Profile E7.5.docx Project for use in the
Printed in Germany | © 09.17 Siemens AG OpenSSL Toolkit
(www.openssl.org)
and cryptographic
E-Mail: support.energy@siemens.com
software written by
Tel: +49 180 524 70 00 Eric Young
(eay@cryptsoft.com).

You might also like