Experiment No :

Date :

MEASUREMENT OF RESISTANCE

AIM:- To determine the value of Armature resistance, Series field resistance and
Shunt field resistance of the given DC compound generator by Voltmeter-Ammeter
method.

MACHINE DETAILS:

DC COMPOUND GENERATOR

Rated Voltage :

Rated Current :

Rated Power :

Rated Speed :

APPARATUS REQUIRED:

SL:NO Item with specification Quantity Remarks


1 Moving coil type Ammeter 0 – 10A 1
2 Moving coil type Ammeter 0 – 2.5A 1
3 Moving coil type Voltmeter 0 – 50V 1
4 Moving coil type Voltmeter 0 – 300V 1
5 Rheostat 230 Ω ,2 A 1
6 Rheostat 6 Ω ,20 A 1
7 DC Low volt supply unit (Rectifier) ( 0 – 50 v) 1
8 230 volt DC supply unit 1
9 Connecting wires ….

THEORY: Ohm’s law states that ,the temperature remains constant, when the
current flowing through a conductor is direcly proportional to the potential
difference between the two ends and inversely proportional to the resistance of the
conductor.

Ie., V =IR, Where R is a constant called resistance of the circuit.

I = V/R , R = V/I.
Sl;No. V I Ra = V/I

Sample calculation of Sl no:3

Volt meter reading V =

Ammeter reading I =

Resistance Ra = V/I =

Mean Ra =
Sl;No. V I Ra = V/I

Sample calculation of Sl no:3

Volt meter reading V =

Ammeter reading I =

Resistance Rse = V/I =

Mean Rse =
Sl;No. V I Ra = V/I

Sample calculation of Sl no:3

Volt meter reading V =

Ammeter reading I =

Resistance Ra = V/I =

Mean Rsh =
PROCEDURE:

(a) For the Measurement of Armature Resistance:

Connections are made as per the connection diagram (1).A low volt DC
supply is applied ,by varying the rheostat different readings are taken, from
the volt meter and Ammeter and are tabulated.Repeat more set of readings
by adjusting the rheostat.From this Armature resistance can be calculated
by using the equation.

R = V/I , Mean value of Ra is calculated.

(b) For the Measurement of Series field Resistance:

Connections are made as per the connection diagram (2).A low volt DC
supply is applied ,by varying the rheostat different readings are taken, from
the volt meter and Ammeter and are tabulated. Repeat more set of readings
by adjusting the rheostat. From this Series field resistance can be calculated
by using the equation.

R = V/I , Mean value of Rse is calculated.

(c ) For the Measurement of Shunt field Resistance:

Connections are made as per the connection diagram (3).A 230 volt DC
supply is applied ,by varying the rheostat different readings are taken, from
the volt meter and Ammeter and are tabulated. Repeat more set of readings
by adjusting the rheostat. From this Shunt field resistance can be calculated
by using the equation.

R = V/I , Mean value of Rsh is calculated.

RESULT:

Armature resistance of the DC machine =

Series field resistance of the DC machine =

Shunt field resistance of the DC machine =