DESIGN MODEL

DESIGN LOAD

DL: Dead load


- Glass: 2500 kg/m3
Used: 12 mm.thk. ,w :34.00 kg/m2
- Stainless Steel: 7850 kg/m3

WL.: WIND LOAD:

Design wind load: 200 kg/m2 (Design conservatively, load pressure pushes-out glass panel)
HL.: HORIZONTAL LOAD (Optional)

HL1:Linear load on rail: 75 kg/m.

HL2: Concentrate load on rail : 89 kg.


DISPLACEMENT.

101:DL+WL

102: DL+HL1
103: DL+HL2
MEMBER SCHEMATIC DESIGN

: POST :TUBE 100x50x3.0mm.

DESIGN FORCE

CRITICAL LOAD CASE 101:DL+WL


UTILIZE DESIGN RATIO, ALLOWABLE < 1.00
DETAIL DESIGN CALCULATION
MEMBER SCHEMATIC DESIGN

: TOP HANDRAIL : TUBE 100x50x3.0mm.

DESIGN FORCE

CRITICAL LOAD CASE 101:DL+WL


UTILIZE DESIGN RATIO, ALLOWABLE < 1.00
DETAIL DESIGN CALCULATION
NODE NUMBER SCHEMATIC DESIGN

REACTION, CRITICAL LOAD CASE 101:DL+WL


Design Of Fixing Expansion Bolts

A. Input Data
Anchor type and size: 4-M10 HILTI-HSL-3-G Or Eq.
Effective embedment depth: 110.00 mm.
Base material: Non cracked concrete Fc': 300 ksc. (cylinder)

B. Design Load (Service load) (kN,m)

C.Resulting anchor forces

D.Anchor strength

Tension capacity: 22.20 kN

Shear capacity: 23.90 kN

E.Combined tension and shear loads


3.50 + 2.20 = 0.25 < 1.00 OK
22.20 23.90
F.Base Plate

Design force / anchor,T : 3.50 kN / anchor


Stainless steel base plate strength, Fy : 205.0 Mpa
Allowable base plate strength,s: 0.75Fy: 153.75 Mpa
Moment arm, d = 21.00 mm.
Moment at base plate, M = T*d = 73500 N.mm
Effective width of bending plane, be = D+2d : 43.00 mm.
Require thickness, treq = (4M/bes)^0.5 = 6.67 mm.
DESIGN GLASS PANEL
DISPLACEMENT LOAD CASE : DL+WL.

Maximum Deflection; Δ max = 18.14 mm.

Allowable Deflection; Δ all = 1500/90 = 16.66 mm. or max 20.00mm.

HENCE Δ max < Δ all ……………….PASS


GLASS PANEL STRESS LOAD CASE : DL+WL

Glass Type: Tempered Glass

Panel Size: 1.50 m x 3.02 m.

Supporting Method: Two sides Pin supported

Thickness of Glass: 6 + 6 mm.

Refer to graphical result,


Maximum Stress; σmax. = 308 Ksc.

Allowable Stress; σall. = 643.74 Ksc. (refer to AS1288-06 T. B1 Ultimate limit state design stress@At edge)

HENCE σmax < σall ……………….PASS