KX6
KX6
KX6
50Hz
09KX01E-A-0
4")
History of Technologies
more efficient , more sophisticated
KX2
KX4
KX6
(8~12HP)
New Line Up
Contents
Introduction Outdoor units Indoor units Control systems Service and maintenance Further information 4~13 14~29 30~57 58~62 63 64~69
4")
Product Line Up
<Outdoor units>
from 11.2kW up to 136.0kW(24models)
1 Outdoor unit type
Capacity Model Index
4HP 11.2
5HP 14.0
6HP 15.5
8HP 22.4
10HP 28.0
12HP 33.5
14HP 40.0
16HP 45.0
18HP 50.4
20HP 56.0
22HP 61.5
24HP 68.0
26HP 73.5
28HP 80.0
30HP 85.0
32HP 90.0
34HP 96.0
36HP
38HP
40HP
42HP
44HP
46HP
48HP
8HP FDC224KXE6
10HP FDC280KXE6
12HP FDC335KXE6
26HP 12+14
28HP 14+14
30HP 14+16
32HP 16+16
34HP 16+18
36HP 18+18
FDC735KXE6 FDC800KXE6 FDC850KXE6 FDC900KXE6 FDC960KXE6 FDC1010KXE6 FDC335KXE6-K FDC400KXE6 FDC400KXE6 FDC450KXE6 FDC450KXE6 FDC504KXE6 FDC400KXE6 FDC400KXE6 FDC450KXE6 FDC450KXE6 FDC504KXE6 FDC504KXE6 38HP 18+20 40HP 20+20 42HP 20+22 44HP 22+22 46HP 22+24 48HP 24+24
FDC1065KXE6 FDC1130KXE6 FDC1180KXE6 FDC1235KXE6 FDC1300KXE6 FDC1360KXE6 FDC504KXE6 FDC560KXE6 FDC560KXE6-K FDC615KXE6 FDC615KXE6 FDC680KXE6 FDC560KXE6 FDC560KXE6 FDC615KXE6 FDC615KXE6 FDC680KXE6 FDC680KXE6
1.FDC335KXE6(12HP), FDC560KXE6-K, FDC615KXE6(22HP) & FDC680KXE6(24HP)are applied 3D compressor. 2.FDC335KXE6-K & FDC560KXE6-K are only used for combining with other models.
<Indoor units>
Wide variety of 15 types 77 models
A range of 15 types of exposed or concealed indoor units, in wide capacities, 77 indoor models. The best selection of indoor units for many kinds of rooms and preference can be available from our full lineup.
15 types 77 models
Capacity Model Index FDT 0.8HP 22 1HP 1.25HP 1.6HP 28 36 45 2HP 56 2.5HP 3.2HP 71 90 4HP 112 5HP 140 6HP 160 8HP 224 10HP 280
4way
FDTC
2way
FDTW
1way Compact
FDTQ
1way High Static Pressure Low/Middle Static Pressure Duct Connected Low Static Pressure (Ultra thin) Compact & Flexible
FDTS
FDU
FDUM
FDQS
FDUH
Wall Mounted
FDK
Ceiling Suspended
FDE
FDFL
FDFU
OA Processing unit
FDU-F
250
350
500
800
1000
R410A
1. High Efficiency
The industry's highest COP levels
We have cleared the class A standard, the highest energy saving level, with our high COP (Coefficient Of Performance).
EER in Cooling
COP 4.5 4.0 3.5 3.0 2.5 4 5 6
CLASS
COP in Heating
CLASS
4.00
3.2
3.46 3.41 3.55 3.47 3.42 3.34
4.15
3.6
3.84 3.71 3.84 3.82 3.74 3.75
10
12
14
16
18
20
HP
10
12
14
16
18
20
HP
(ISO-T1 conditions)
Power Consumption[kW] *COP = Capacity[kW] /range ensures reduced running costs and reduced environmental impact. COP across the KX6 *
2. Compact Design
4~6HP
Volume
35% reduced
Weight
1FAN
34% reduced
Previous Model
H1300 x W970 x D370mm 125kg / 0.47m3
Transportation Becomes much easier Easier to hide behind the fence
New Model
H845 x W970 x D370mm 82kg / 0.30m3
(Harmonic Appearance)
8~12HP
Volume
2FAN
47% reduced
Weight
10% reduced
Previous Model
H1690 x W1350 x D720mm 245kg / 0.97m3
Transportation Becomes much easier
New Model
H1675 x W1080 x D480mm 221kg / 0.52m3 (FDC224KXE6)
High efficiency and compact design are realized applying the various advanced functions 4~6HP
Compact High Efficient Heat Exchanger New Inverter Control
Vector Inverter Control system
DC Fan Motor
Compact & High efficiency
KX4
KX6
8~12HP
New DC Fan motor
Compact & High efficiency
Downsized accumulator
14~48HP
DC Fan Motor Expansion of Heat Exchanger Tetrahedral structure of Heat Exchanger
Double tube
R410A
3D Scroll Compressor
Unit start up speed in heating mode drastically improved for lower outdoor temperature operation.
Present scroll
Same height Fixed scroll
3D scroll
Lower at the inside Higher at the outside
2-Dimension compression
Orbital scroll
3-Dimension compression
3D scroll compressor has the different height scroll at the outside and the inside. A high compression ratio is improved by compressing the refrigerant both radially and axially. 3-Dimension Compression has been realized with a much higher efficiency even if compression ratio is high.
The strength of the scroll is improved by reducing the height of the inner wrap, which receives a heavy load.
DC Fan Motor
Employment of DC fan motor has enabled to realize an excellent efficiency of approximate 60% higher than previous models.
Rotor(Squirrel Cage made of conductor) Stator (coil) Rotor(made of permanent magnet) Stator (coil)
3. Design Flexibility
Increased indoor unit connection capacity
KX6 series(4~34HP) can connect indoor unit capacity up to 150~200% from 130% of previous models. If the connection capacity of indoor units is more than 100%, capacity of each indoor unit may be affected by connection capacity ratio.
Capacity connection
HP 4~12 14,16 18~34 36~48 KX4 130% 130% 130% 130% HP 4~12 14,16 18~34 36~48 KX6 150% 200% 160% 130%
In case that capacity connection is more than 130%, additional charge of refrigerant is required on site.
KX6
KX4
4 5 6
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48 HP
Control Systems
KX6 series offer wide variation of control system and provide the best solution. [KX6 Control system units with "New" SUPERLINK- ]
Classification Type Model Connectable Indoor units (Maximum) Electric power calculation
Individual controller
Center Console PC windows interface units BMS interface BACnet units Lonworks
RC-E3 RCN-T-36W-E etc. SC-SL1N-E SC-SL2N-E SC-SL3N-AE SC-SL3N-BE SC-WGWN-A SC-WGWN-B SC-BGWN-A SC-BGWN-B SC-LGWN-A
R410A
8~12HP
Total length: 510m
Outdoor unit To the first branch: max 130m
Height difference 50m(outdoor unit above) 40m(outdoor unit below) Max height difference between indoor units: 4m 18m
14~48HP
Max: 10m
Outdoor unit
Max: 0.4m
Indoor unit
To the first branch: max 130m From the first branch to the furthest * indoor unit: 40m 90m
Max: 5m
Indoor unit
Height difference 50m(outdoor unit above) 40m(outdoor unit below) Max height difference between indoor units: 15m 18m
From the first branch to the furthest indoor unit: 40m 90m
Indoor unit
Indoor unit
Indoor unit
Indoor unit
(1)Divide up the refrigerant system into independent refrigeration circuit systems in case required additional refrigerant on site is 50kg or more for 14~24HP and 100kg or more for 26~48HP. (2)In case indoor unit connection capacity is 130% or more or total piping length is 510m or more, additional charge of refrigerant and oil on site is required. Refer to our Installation Manual for details.
8~12HP
H1,675 x W1,080 x D480 850
Easy transportation
800
KX6(14~48HP) is portable and the uniform reduced footprint allows neat, continuous installation.
1350mm
1350mm
1350mm
10
Range of Operation
KX6 series permits a system design considering a heating range operation under a low temperature condition up to -20C from -15C of previous model and a cooling range operation under -15C from -5C of that.
-20C
-15C
Heating NEW
previous
+15.5C
-15C
-5C
Cooling NEW
previous
+43C
-20 -10 0 10 20 30 40 For the capacities under low temperature conditions, refer to technical manual.
50
previous
New previous
!-core
-core
m
#m
New
4. Serviceability
Easy Service
Quick and easy access to service parts by separation of compartments.
Mechanical compartment
11
R410A
Monitoring Function
KX6 series includes new feature to assist with servicing and trouble shooting. Various data can be monitored through 3-degit display on the outdoor unit PCB. Detailed fault diagnosis and operation history memory via 7-segment display. Equipped with RS232C for connection directly to your PC monitoring and service tasks made simple with our service software (Mente PC). all KX6 series
4~6HP
8~48HP
Back-up Operation
In, 2-compressor module, in the event of the compressor failure, the system will keep operating with good compressor. In combined module, in the event that one unit has a failure, the system will keep operating with another unit.
Keeping operation
Compressor failed
Inverter
Blue Fin
Due to application of blue coated fins (KS101) for the heat exchanger of new outdoor unit, corrosion resistance has been improved compared to current models.
Outdoor unit
KX6 HP Liquid piping Gas piping 4 15.88 5 6 9.52 19.05 8 22.22 10 12 25.4[28.58] 14 16 12.7 18 28.58 20 22 24 26 28 31.8[34.92] 30 15.88 32 34 36 38 40 38.1[34.92] 42 19.05 44 46 48 [ ]: Pipe sizes applicable to European installations are shown in parentheses.
1" 11/8" 11/4" 13/8" 11/2" 13/4" 2"
Blue Fin
KX6 R410A
9.52 22.22
Liquid piping
Gas piping
ex.10HP
mm 9.52 12.7 15.88 19.05 22.22 25.4 28.58 31.8 34.92 38.1 44.5 50.8 inch 3/8" 1/2" 5/8" 3/4" 7/8"
12
Fixed Cooling mode/fixed heating mode (summer/winter switch): It is possible to fix the operational mode of the system (either cooling or heating) using a switch (SW3-7) on the outdoor unit PC board - this enables the building user to decide the operation of the system (e.g. cooling only in summer/heating only in winter), to avoid unnecessary energy wastage. It is also possible to wire the control switch to a remote location (inside the building) to a control room, or even linked to an ambient thermostat.
13
4")
Blue Fin
The KX6 heat pump 2-pipe systems offer high performance VRF for
applications that require either cooling only or heating only, ideal for open plan areas. Connect up to 8 indoor units/up to 150% capacity. High efficiency with COP (in cooling) up to 4.0. KX6 employs DC inverter compressors ONLY. Industry leading total piping length up to 100m and a maximum pipe run of 70m.
Range of operation
50
+43C
40
30
Indoor unit
20
Cooling
Max height
+15.5C
Indoor unit
10
Heating
-10
-15C
-20
-20C
Specifications
Item Nominal horse power Power source Nominal capacity Model
FDC112KXEN6
4HP 11.2 12.5 2.80 2.89 13.5-12.4 14.1-12.9
FDC140KXEN6
5HP 1 Phase 220-240V, 50Hz 14.0 16.0 4.17 4.31 20.6-18.9 21.5-19.7
FDC155KXEN6
6HP 15.5 16.3 5 4.71 4.38 23.3-21.3 21.9-20.1
FDC112KXES6
4HP 11.2 12.5 2.80 2.89 4.5-4.1 4.7-4.3
FDC140KXES6
5HP 3 Phase 380-415V, 50Hz 14.0 16.0 4.17 4.31 6.9-6.3 7.2-6.6
FDC155KXES6
6HP 15.5 16.3 4.71 4.38 7.8-7.1 7.3-6.7
Cooling kW Heating A Starting current Cooling Power kW Electrical characteristics consumption Heating Cooling Running A current Heating Exterior dimensions mm HxWxD Net weight kg Refrigerant charge kg R410A dB(A) Cooling/Heating Sound pressure level Liquid line mm(in) Refrigerant piping size Gas line % Capacity connection Number of connectable indoor units
845x970x370 82 5.0 52/54 53/55 53/56 9.52(3/8") 15.88(5/8") 50~150 6 8 8 6 8 8 52/54 53/55 53/56
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. Piping length is 7.5m. 2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
14
Dimensions
All measurements in mm.
L2
Intake
L3
Intake
L4 L1
40 100 36 51
B
Terminal block
B A
845
A
F
110
242
279
195
10
195
55
50
50 52 27 50
C
970
50
15
110
E
190 60 20 40 60 580 200 60 15 15 55 103
410
370
38
150
C
20 40 262 388
50
70
40
VIEW A
15
50
Mark A B C D E F
Item Service valve connection (gas side) Service valve connection (liquid line) Pipe/cable draw-out port Drain discharge port Anchor bolt hole Cable draw-out port 15.88 (5/8") (flare) 9.52 (3/8") (flare) 4 places 20 x 3 places M10 x 4 places 30 x 3 places L1 L2 L3 L4
I
Open 300 150 5
II
Open 5 300 5
II
500 Open 150 5
Notes: (1) It must not be surrounded by walls on the four sides. (2) The unit must be fixed with anchor bolts. An anchor bolt must not protrude more than 15mm. (3) Where the unit is subject to strong winds, lay it in such a direction that the blower outlet faces perpendicularly to the dominant wind direction. (4) Leave a 1m or larger space above the unit. (5) A wall in front of the blower outlet must not exceed the units height. (6) The unit name plate is attached on the lower right corner of the front panel.
15
4")
Blue Fin
The KX6 heat pump 2-pipe systems offer high performance VRF for
applications that require either cooling only or heating only, ideal for open plan areas.
Connect up to 22 indoor units/up to 150% capacity. High efficiency with COP (in cooling) up to 4.0. KX6 employs DC inverter compressors ONLY. Industry leading total piping length up to 510m and a maximum pipe
run of 160m.
+43C
Indoor unit
Height difference 50m(outdoor unit above) 40m(outdoor unit below) Max height difference between indoor units: 18m
-10
40
30
Cooling
20
+15.5C
From the first branch to the furthest indoor unit: 90m Furthest indoor unit: 160m
Indoor unit
10
Indoor unit
Heating
-20C
-20
-20C
Specifications
Item Nominal horse power Power source Nominal capacity Model
FDC224KXE6
8HP 22.4 25.0 5.60 6.03 9.25-8.47 9.85-9.02 221 58/58 9.52(3/8") 19.05(3/4") 15
FDC280KXE6
10HP 3 Phase 380V-415V, 50Hz 28.0 31.5 5 8.09 8.21 13.22-12.10 13.41-12.28 1675x1080x480 11.5 59/60 22.22(7/8") 50~150 19
FDC335KXE6
12HP 33.5 37.5 9.82 10.12 15.87-14.53 16.36-14.98 224 61/61 12.7(1/2") 25.4(1") [28.58(1 1/8")] 22
Cooling kW Heating A Starting current Cooling Power kW Electrical characteristics consumption Heating Operating Cooling A current Heating HxWxD Exterior dimensions mm Net weight kg R410A Refrigerant charge kg Cooling/Heating dB(A) Sound pressure level Liquid line mm(in) Refrigerant piping size Gas line % Capacity connection Number of connectable indoor units
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. Piping length is 7.5m. 2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions. 3. [ ] : Pipe sizes applicable to European installations are shown in parentheses.
16
Dimensions
All measurements in mm.
L2
Intake
L3
Intake
L4
L1
Outlet
69 51
Service space
43 60 120
Terminal block
1675
69
B A G
A
553 640(8.10HP) 634(12HP)
20
159 194
174 84
84
F
1080
51
54 14
159 84
35
35
67 42
50
14
54 51
55
55
E
19 39
195
690 50
195
E
30 30
989
520 480
105
Mark A B C D E F G
Item Service valve connection of the attached connecting pipe (gas side) Service valve connection (liquid side) Pipe/cable draw-out hole Drain discharge hole Anchor bolt hole Cable draw-out hole Connecting position of the local pipe. (gas side)
19 39
FDC224KXE6
FDC280KXE6
55
FDC335KXE6
19.05 (3/4") (Flare) 9.52 (3/8") (Flare) 20 x 4places M10 x 4places 30 x 2places (front) 45 (side) 30 x 2places (back) 19.05 (3/4")(Brazing)
19.05 (3/4") (Flare) 9.52 (3/8") (Flare) 20 x 4places M10 x 4places 30 x 2places (front) 45 (side) 30 x 2places (back) 22.22 (7/8")(Brazing)
19.05 (3/4") (Flare) 12.7 (1/2") (Flare) 20 x 4places M10 x 4places 30 x 2places (front) 45 (side) 30 x 2places (back) 25.4 (1")(Brazing)
Notes: (1) It must not be surrounded by walls on the four sides. (2) The unit must be fixed with anchor bolts. An anchor bolt must not protrude more than 15mm. (3) Where the unit is subject to strong winds, lay it in such a direction that the blower outlet faces perpendicularly to the dominant wind direction. (4) Leave a 1m or larger space above the unit. (5) A wall in front of the blower outlet must not exceed the units height. (6) The model name label is attached on the lower right corner of the front. (7) Connect the Service valve with local pipe by using the pipe of the attachment.(Gas side only) (8) Mark shows the connecting position of the local pipe.(Gas side only)
II
Open 5 300 5
II
1500 Open 300 5
L1 L2 L3 L4
17
4")
Blue Fin
The KX6 heat pump 2-pipe systems offer high performance VRF for
applications that require either cooling only or heating only, ideal for open plan areas.
Connect up to 40 indoor units/up to 200% capacity. High efficiency with COP (in cooling) up to 3.6. KX6 employs DC inverter compressors ONLY. Industry leading total piping length up to 1000m and a maximum
pipe run of 160m.
Outdoor unit Range of operation Height difference 50m(outdoor unit above) 40m(outdoor unit below) Max height difference between indoor units: 15m
50
+43C
40
Indoor unit
30
From the first branch to the furthest indoor unit: 40m Furthest indoor unit: 160m
Indoor unit
Cooling
20
+15.5C
10
Indoor unit
Heating
-10
-20
-20C
-20C
Specifications
Item Nominal horse power Power source Nominal capacity Model
FDC400KXE6
14HP 3 Phase 380-415V, 50Hz 40.0 45.0 8 11.27 11.73 18.4-16.9 19.6-17.9 1690x1350x720 317 11.5 59.5/60 12.7(1/2") 25.4(1") [28.58(1 1/8")] 50~200 36
FDC450KXE6
16HP 45.0 50.0 12.97 13.10 21.1-19.3 21.719.9
Cooling kW Heating A Starting current Cooling Power kW Electrical characteristics consumption Heating Operating Cooling A current Heating HxWxD Exterior dimensions mm Net weight kg R410A Refrigerant charge kg Cooling/Heating dB(A) Sound pressure level Liquid line mm(in) Refrigerant piping size Gas line % Capacity connection Number of connectable indoor units
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. Piping length is 7.5m. 2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions. 3. [ ] : Pipe sizes applicable to European installations are shown in parentheses.
18
Dimensions
All measurements in mm.
250 175 850 1000 250 175 74.5 85 101 232 D(lower) 185
Rear
C 594 232
Anchor bolt positions for I
K B
58.5
19
F I
I F
726
647
85
57
95 140.5
141
75 142.5 234
58.5
19
Air intake
G
148 410 352 158 530 342 235
1690 797.8
126.2
720
1350
7-segment display inspection port 682 Signal wire terminal block Terminal block for power cable connection
K B A C (front)
166 169 211 259 291.6
120
22
80.5 71
C (right)
C (rear)
L
44.7
84
D (left)
104.9
95
90
D (right)
D (front)
Mark A B C D F G H K* L
Item Service valve connection (gas side) Service valve connection (liquid line) Refrigerant pipe draw-out port Power cable draw-in port Anchor bolt hole Drain hose hole Drain discharge port Oil-equalising pipe joint Sling holes for haulage or hoisting
For refrigerant piping, please refer to the unit specifications.
Intake
Installation example
Dimensions
L2
L3
Wall height H3 L4
Intake
Wall height H2
Intake
Wall height H4 Wall height H1
L1 L2 L3 L4 H1 H2 H3 H4
Service space
Intake
Notes: (1) The unit must be fixed with anchor bolts. (2) Leave a 2m or larger space above the unit. (3) The unit name plate is attached on the lower right corner of the front panel. (4) The ports for refrigerant pipe and power cable penetrations are covered with half-blanks. Please cut off a half-blank with nippers in using these ports. (5) Use a 88 port for refrigerant pipe connection. (6) Anchor holes marked L J (four holes for M10) are for a renewal installation. (7) The oil-equalising pipe K should be used when outdoor units are used in combination. (For 14,16Hp only)
Installation example
Dimensions
L1
20
Instruction plate
6 86.1
172
172
80
L3
Wall height H2 Wall height H4
L1
L6 L4
L2
L5
L2 L3 L4 L5 L6 H1 H2 H3 H4
No restrictions No restrictions
19
4")
Blue Fin
The KX6 heat pump 2-pipe systems offer high performance VRF for
applications that require either cooling only or heating only, ideal for open plan areas.
Connect up to 49 indoor units/up to 160% capacity. High efficiency with COP (in cooling) up to 3.4. KX6 employs DC inverter compressors ONLY. Industry leading total piping length up to 1000m and a maximum
pipe run of 160m.
Uniform footprint of all models (from 8hp~24hp) allows continuous sideby-side installation
+43C
Indoor unit
Height difference 50m(outdoor unit above) 40m(outdoor unit below) Max height difference between indoor units: 15m
-10
40
30
Cooling
20
+15.5C
From the first branch to the furthest indoor unit: 40m Furthest indoor unit: 160m
Indoor unit
10
Indoor unit
-5C
Heating
-20
-20C
Specifications
Item Nominal horse power Power source Nominal capacity Model
FDC504KXE6
18HP 50.4 56.5 14.73 15.12 24.1-22.0 25.2-23.1 341
FDC560KXE6
20HP
FDC615KXE6
22HP
FDC680KXE6
24HP 68.0 73.0 24.98 19.08 40.3-36.9 31.6-29.0 355
3 Phase 380-415V, 50Hz 56.0 63.0 8 16.79 16.79 27.4-25.1 28.0-25.7 2048x1350x720 11.5 61.5/62.0 63.0/63.5 12.7(1/2") 28.58(1 1/8") 50~200 36 40 50~160 44 49 64.5/64.0 65.0/65.0 20.37 18.48 33.1-30.3 30.7-28.1 61.5 69.0
Cooling kW Heating A Starting current Cooling Power kW Electrical characteristics consumption Heating Operating Cooling A current Heating HxWxD Exterior dimensions mm Net weight kg R410A Refrigerant charge kg Cooling/Heating dB(A) Sound pressure level Liquid line mm(in) Refrigerant piping size Gas line % Capacity connection Number of connectable indoor units
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. Piping length is 7.5m. 2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
20
Dimensions
All measurements in mm.
250 175 850 1000 250 175 74.5 85 101 232 D(lower) 185 Rear Dimensions of refrigerant pipe connection (plan)
C 594 232
Anchor bolt positions for I
K B
58.5
F I
I F
19
726
647
85
57
95 140.5
141
75 142.5 234
58.5
19
Air intake
G
148 410 352 158 530 342 235
2048
1155.8
126.2
720
1350
Drain pipe
7-segment display inspection port 682 Signal wire terminal block 175 Terminal block for power cable connection
K B A C (front)
166 169 211 259 291.6
120
22
80.5 71
C (right)
C (rear)
L
44.7
84
D (left)
80
104.9
95
90
D (right)
D (front)
Mark A B C D F G H K L
Item Service valve connection (gas side) Service valve connection (liquid line) Refrigerant pipe draw-out port Power cable draw-in port Anchor bolt hole Drain hose hole Drain discharge port Oil-equalising pipe joint Sling holes for haulage or hoisting
For refrigerant piping, please refer to the unit specifications.
Intake
Installation example
Dimensions
L2
L3
Wall height H3 L4
Intake
Wall height H2
Intake
Wall height H4 Wall height H1
100 50 M10 x 4 places 45.3 x 3 places 20.5 x 3 places 9.52 flare 180 x 44.7
L1 L2 L3 L4 H1 H2 H3 H4
Service space
Intake
Notes: (1) The unit must be fixed with anchor bolts. (2) Leave a 2m or larger space above the unit. (3) The unit name plate is attached on the lower right corner of the front panel. (4) The ports for refrigerant pipe and power cable penetrations are covered with half-blanks. Please cut off a half-blank with nippers in using these ports. (5) Use a 88 port for refrigerant pipe connection. (6) Anchor holes marked L J (four holes for M10) are for a renewal installation. (7) The oil-equalising pipe K should be used when outdoor units are used in combination.
L1
20
Instruction plate
6 86.1
172
172
21
4")
Blue Fin
The KX6 heat pump 2-pipe systems offer high performance VRF for
applications that require either cooling only or heating only, ideal for open plan areas.
Connect up to 65 indoor units/up to 160% capacity. High efficiency with COP (in cooling) up to 3.6. KX6 employs DC inverter compressors ONLY. Industry leading total piping length up to 1000m and a maximum
pipe run of 160m.
Uniform footprint of all models (from 8hp~24hp) allows continuous side-byside installation
+43C
Indoor unit
Height difference 50m(outdoor unit above) 40m(outdoor unit below) Max height difference between indoor units: 15m
-10
40
30
Cooling
20
+15.5C
From the first branch to the furthest indoor unit: 40m Furthest indoor unit: 160m
Indoor unit
10
Indoor unit
-5C
Heating
-20
-20C
Specifications
Item Combination (FDC) Nominal horse power Power source Cooling kW Heating A Starting current Cooling Power kW Electrical characteristics consumption Heating Cooling Operating A current Heating HxWxD mm Exterior dimensions kg Net weight R410A kg Refrigerant charge Liquid line mm(in) Refrigerant piping size Gas line % Capacity connection Number of connectable indoor units Nominal capacity Model
FDC735KXE6
335KXE6-K 400KXE6 26HP 73.5 82.5 20.21 20.66 32.9-30.2 34.4-31.4
FDC800KXE6
FDC850KXE6
FDC900KXE6
450KXE6 450KXE6 32HP 90.0 100.0 25.94 26.20 42.2-38.6 43.4-39.8
53
400KXE6 400KXE6 400KXE6 450KXE6 28HP 30HP 3 Phase 380-415V, 50Hz 80.0 85.0 90.0 95.0 16 22.54 24.24 23.46 24.83 36.8-33.8 39.5-36.2 39.2-35.8 41.3-37.8 1690x2700x720 317x2 11.5x2 15.88(5/8") 31.8(1 1/4") [34.92(1 3/8")] 50~160 58 61
65
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. Piping length is 7.5m. 2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions. 3. [ ] : Pipe sizes applicable to European installations are shown in parentheses.
22
Dimensions
All measurements in mm.
250 175 850 1000 250 175 74.5 85 101 232 D(lower) 185
Rear
C 594 232
Anchor bolt positions for I
K B
58.5
19
F I
I F
726
647
85
57
95 140.5
141
75 142.5 234
58.5
19
Air intake
G
148 410 352 158 530 342 235
1690 797.8
126.2
720
1350
7-segment display inspection port 682 Signal wire terminal block Terminal block for power cable connection
K B A C (front)
166 169 211 259 291.6
120
22
80.5 71
C (right)
C (rear)
L
44.7
84
D (left)
104.9
95
90
D (right)
D (front)
Mark A B C D F G H K L
Item Service valve connection (gas side) Service valve connection (liquid line) Refrigerant pipe draw-out port Power cable draw-in port Anchor bolt hole Drain hose hole Drain discharge port Oil-equalising pipe joint Sling holes for haulage or hoisting
For refrigerant piping, please refer to the unit specifications.
Notes: (1) The unit must be fixed with anchor bolts. (2) Leave a 2m or larger space above the unit. (3) The unit name plate is attached on the lower right corner of the front panel. (4) The ports for refrigerant pipe and power cable penetrations are covered with half-blanks. Please cut off a half-blank with nippers in using these ports. (5) Use a 88 port for refrigerant pipe connection. (6) Anchor holes marked L J (four holes for M10) are for a renewal installation. (7) The oil-equalising pipe K should be used when outdoor units are used in combination.
20
Instruction plate
6 86.1
172
172
80
23
4")
Heat pump combination systems 34, 36, 38, 40, 42, 44, 46, 48hp (96.0kW~136.0kW)
Model No. FDC960KXE6 (FDC450+FDC504) FDC1010KXE6 (FDC504x2) FDC1065KXE6 (FDC504+FDC560) FDC1130KXE6 (FDC560x2) FDC1180KXE6 (FDC560+FDC615) FDC1235KXE6 (FDC615x2) FDC1300KXE6 (FDC615+FDC680) FDC1360KXE6 (FDC680x2) Nominal Cooling Capacity 96.0kW 101.0kW 106.5kW 113.0kW 118.0kW 123.5kW 130.0kW 136.0kW
Blue Fin
The KX6 heat pump 2-pipe systems offer high performance VRF for applications that
require either cooling only or heating only, ideal for open plan areas. Connect up to 80 indoor units/up to 130% (960KXE6:160%) capacity.
High efficiency with COP (in cooling) up to 3.5. KX6 employs DC inverter compressors ONLY. Industry leading total piping length up to 1000m and a maximum pipe run of 160m.
Total length: 1000m
To the first branch: max 130m Range of operation Outdoor unit
50
+43C
Indoor unit
Height difference 50m(outdoor unit above) 40m(outdoor unit below) Max height difference between indoor units: 15m
-10
40
30
Cooling
20
+15.5C
From the first branch to the furthest indoor unit: 40m Furthest indoor unit: 160m
Indoor unit
10
Indoor unit
-5C
Heating
-20
-20C
Specifications
Item Combination (FDC) Nominal horse power Power source Cooling kW Heating A Starting current Cooling Power kW Electrical characteristics consumption Heating Operating Cooling A current Heating HxWxD mm Exterior dimensions kg Net weight R410A kg Refrigerant charge Liquid line mm(in) Refrigerant piping size Gas line % Capacity connection Number of connectable indoor units Nominal capacity Model
19.05(3/4")
69
59
62
72
76
80
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. Piping length is 7.5m. 2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
24
Dimensions
All measurements in mm.
250 175 850 1000 250 175 74.5 85 101 232 D(lower) 185 Rear Dimensions of refrigerant pipe connection (plan)
C 594 232
Anchor bolt positions for I
K B
58.5
F I
I F
19
726
647
85
57
95 140.5
141
75 142.5 234
58.5
19
Air intake
G
148 410 352 158 530 342 235
2048
1155.8
126.2
720
1350
Drain pipe
7-segment display inspection port 682 Signal wire terminal block 175 Terminal block for power cable connection
K B A C (front)
166 169 211 259 291.6
120
22
80.5 71
C (right)
C (rear)
L
44.7
84
D (left)
80
104.9
95
90
D (right)
D (front)
Mark A B C D F G H K L
Item Service valve connection (gas side) Service valve connection (liquid line) Refrigerant pipe draw-out port Power cable draw-in port Anchor bolt hole Drain hose hole Drain discharge port Oil-equalising pipe joint Sling holes for haulage or hoisting
For refrigerant piping, please refer to the unit specifications.
100 50 M10 x 4 places 45.3 x 3 places 20.5 x 3 places 9.52 flare 180 x 44.7
Notes: (1) The unit must be fixed with anchor bolts. (2) Leave a 2m or larger space above the unit. (3) The unit name plate is attached on the lower right corner of the front panel. (4) The ports for refrigerant pipe and power cable penetrations are covered with half-blanks. Please cut off a half-blank with nippers in using these ports. (5) Use a 88 port for refrigerant pipe connection. (6) Anchor holes marked L J (four holes for M10) are for a renewal installation. (7) The oil-equalising pipe K should be used when outdoor units are used in combination.
20
Instruction plate
6 86.1
172
172
25
4")
HEAD8-371-1
90
90
56
56
36
36
36
36
Gas pipe
56
56
36
36
36
112
112
112
26
19.05 22.22
Good
Floor
DIS-22-1/DIS-180-1
HEAD6-180-1R
No Good
Vertically
No
Floor
DIS-540-2/DIS-371-1
DOS-2A-1
Floor
112
112
90
90
90
140
140
140
Outdoor unit's branching piping Outdoor unit 2 units (for 735~1360) Branch piping set DOS-2A-1
HEAD8-540-2
Indoor unit's first branching piping Total capacity of indoor units ~179 180~370 371~539 540~ Branch piping set DIS-22-1 DIS-180-1 DIS-371-1 DIS-540-2 Header set Model HEAD4-22-1 HEAD6-180-1 HEAD8-371-1 HEAD8-540-2 Branches Max 4 branches Max 6 branches Max 8 branches Max 8 branches
112
112
90
90
90
140
140
140
27
4")
Earth leakage breaker (Impulse withstanding type) Circuit breaker for cabling Grounding wire
Outdoor unit
A Power cable (Main Power cable)[4 cores] B Signal wire (Super Link wire)[2 cores] C Power cable (Indoor unit power cable)
[2 cores]
C
Circuit breaker for cabling Earth leakage breaker
Indoor unit
D R R R R R R
Remote control unit
CAUTION
If the earth leakage breaker is exclusively for ground fault protection, then you will need to install a circuit breaker for wiring work.
28
A1
B1
Indoor and outdoor signal line do not have a polarity. Any of the connections in the following illustration can be made.
A1
Indoor signal line terminal block
A B
A1 B1
A B
B1
3. We recommend only one end of the shield of the cable is connected to ground (earth) at one of the outdoor units. At all other terminal connections on the same network, connect all the shields together and electrically insulate them. This will prevent accidental grounding at 2 points and eliminate any electrical noise.
Outdoor unit
Outdoor unit
Outdoor unit
Outdoor unit
Network connector
A1B1 A2B2
Indoor unit
A1B1 A2B2
A1B1 A2B2
Indoor unit
A1B1 A2B2
A B
A B
4. When plural outdoor units are used, .Connect the signal cable between indoor Refrigerant pipe Indoor unit Indoor unit and outdoor units and the signal cable A A between outdoor units belonging to the B B same refrigerant line to A1 and B1. .Connect the signal line between outdoor Signal line units on different refrigerant lines to A2 and B2. (a) The maximum number of indoor units that can be connected in a system is 128 and it is possible to configure outdoor units and/or indoor units as an outdoor or indoor unit group connected with each other with two wires. 5. For current specification of 2-core (AB) wiring, please consult your MHI dealer. (b) The signal wires can also be connected using the method shown below.
(3) The signal lines can also be connected using the method shown below.
Important
Outdoor unit Outdoor unit Outdoor unit Outdoor unit
Outdoor unit
Outdoor unit
Outdoor unit
Indoor unit
Indoor unit
Indoor unit
The signal lines cannot form a loop, so the wirings shown as in the diagram are prohibited.
Indoor unit Indoor unit Indoor unit Indoor unit
Indoor unit
Indoor unit
Indoor unit
Wire size 0.5mm2 x 2 core 0.75mm2 x 2 core 1.25mm2 x 2 core 2.0mm2 x 2 core
A
Indoor unit
A
Indoor unit
A
Indoor unit
A
Indoor unit
29
4")
According to room temperature conditions, four directions of air flow can be controlled by individual flap as preferred. As individual flap control is available even after installation, installation area became wider than before.
Thanks to new design of heat exchanger changed from 2 parts to 1 part, the height of indoor unit is reduced drastically. Furthermore applying DC fan motors to FDT models, the highest energy efficiency level, reduction of weight and significant compact design are realized.
270mm
Previous
New
365mm
Due to optimization of outlet design of air flow with our new advanced technology, sufficient air flow is secured and long reach of air flow is realized.
Previous New
246
mm
FDT28~71
298
mm
FDT112~160
reduction!!
9%
reduction!!
18%
Specifications
Item Model FDT28KXE6A Nominal cooling capacity kW 2.8 Nominal heating capacity kW 3.2 Power source Cool Power consumption Heat kW Sound pressure level dB(A) Exterior dimensions mm HxWxD Net weight kg Air flow (Standard) CMM Outside air intake Panel Air filter, Qty Remote control Liquid line:6.35(1/4") Installation data Refrigerant piping size mm(in) Gas line:9.52(3/8") Accessories
FDT36KXE6A
3.6 4.0 0.03-0.03 0.03-0.03
FDT45KXE6A
4.5 5.0
FDT56KXE6A
5.6 6.3
FDT71KXE6A
Hi:33 Me:31 Lo:30 Unit:246x840x840 Panel:35x950x950 Unit:22 Panel:5.5 Hi:18 Me:16 Lo:14 Unit:24 Panel:5.5
Unit:298x840x840 Panel:35x950x950 Unit:27 Panel:5.5 Hi:27 Me:24 Lo:20 Hi:30 Me:27 Lo:23
Possible T-PSA-36W-E Pocket Plastic net x1 (Washable) wired:RC-E3, RCH-E3 wireless:RCN-T-36W-E Liquid line:6.35(1/4") Gas line:12.7(1/2") Mounting kit, Drain hose Liquid line:9.52(3/8") Gas line:15.88(5/8")
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. 2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
30
Dimensions
All measurements in mm.
31
4")
CLEARERAIR FLOW
295~325
New shape & angled louvre re-directs the air current away from the ceiling, to reduce ceiling stains
INSTALLATION WORKABILITY
For wireless control simply insert the infra-red receiver kit on a corner of the panel
600 or less (Max. Drain up) 248 Opening for exit wiring
Specifications
Model Item Nominal cooling capacity kW Nominal heating capacity kW Power source Cool Power consumption Heat kW Sound pressure level dB(A) Exterior dimensions mm HxWxD Net weight kg Air flow (Standard) CMM Outside air intake Panel Air filter, Qty Remote control Installation data Refrigerant piping size mm(in) Unit:14 Panel:3.5 Hi:9.5 Me:8.5 Lo:8
FDTC22KXE6A
2.2 2.5
FDTC28KXE6A
2.8 3.2 0.03-0.03 0.03-0.03
FDTC36KXE6A
3.6 4.0 1 Phase 220-240V, 50Hz
FDTC45KXE6A
4.5 5.0 0.04-0.04 0.04-0.04
FDTC56KXE6A
5.6 6.3
Unit:15 Panel:3.5 Hi:10 Me:9 Lo:8 Hi:11 Me:10 Lo:9 Not possible TC-PSA-24W-ER Pocket Plastic net x1 (Washable) wired:RC-E3, RCH-E3 wireless:RCN-TC-24W-ER Liquid line:6.35(1/4") Gas line:12.7(1/2")
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. 2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
32
Dimensions
All measurements in mm.
33
4")
Specifications
Item Model Nominal cooling capacity kW Nominal heating capacity kW Power source Cool Power consumption Heat kW Sound pressure level dB(A) Exterior dimensions mm HxWxD Net weight kg Air flow (Standard) CMM Outside air intake Panel Air filter, Qty Remote control
FDTW28KXE6
2.8 3.2
FDTW45KXE6
4.5 5.0 0.09-0.10 0.09-0.10 Hi:39 Me:34 Lo:32
FDTW56KXE6
5.6 6.3
FDTW71KXE6
FDTW90KXE6
FDTW112KXE6
11.2 12.5 0.18-0.20 0.18-0.20 Hi:44 Me:38 Lo:37
FDTW140KXE6
14.0 16.0 0.20-0.24 0.20-0.24 Hi:45 Me:41 Lo:39
7.1 9.0 8.0 10.0 1 Phase 220-240V, 50Hz 0.10-0.11 0.12-0.13 0.10-0.11 0.12-0.13 Hi:41 Me:36 Lo:35 Hi:41 Me:37 Lo:36 Unit:342x1054x620 Panel:8x1300x680
Unit:357x1524x620 Panel:8x1770x680 Unit:38 Panel:11 Hi:28 Me:25 Lo:23 Hi:32 Me:28 Lo:24 TW-PSA-44W-E Pocket Plastic net x2 (Washable)
Unit:26 Panel:9 Hi:16 Me:13 Lo:11 Hi:19 Me:16 Lo:12 Possible TW-PSA-24W-E TW-PSA-34W-E Pocket Plastic net x1 (Washable) wired:RC-E3, RCH-E3 wireless:RCN-KIT3-E Liquid line:6.35(1/4") Gas line:12.7(1/2")
Liquid line:6.35(1/4") Installation data Refrigerant piping size mm(in) Gas line:9.52(3/8")
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. 2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
Dimensions
All measurements in mm.
FDTW71KXE6, 90KXE6
FDTW112KXE6, 140KXE6
Dimension Table
model FDTW28,45,56KXE6 FDTW71,90KXE6 FDTW112,140KXE6 a 127 127 137 b 47 50 50 c 98 95 110 d 91 88 103 e 1055 f 965 g 214 226 241 h 405 410 410 i 234 284 299
Unit:mm
34
Specifications
Item Model Nominal cooling capacity kW Nominal heating capacity kW Power source Cool Power consumption Heat kW Sound pressure level dB(A) Exterior dimensions mm HxWxD Net weight kg Air flow (Standard) CMM Outside air intake Panel Air filter, Qty Remote control Installation data Refrigerant piping size mm(in)
FDTS45KXE6
4.5 5.0 1 Phase 220-240V, 50Hz 0.09-0.11 0.09-0.11 Hi:43 Me:38 Lo:36 Unit:194x1040x650 Panel:10x1290x770 Unit:27 Panel:6 Hi:14 Me:12 Lo:10 Possible TS-PSA-29W-E Pocket plastic net x2 (Washable) wired:RC-E3, RCH-E3 wireless:RCN-KIT3-E Liquid line:6.35(1/4") Gas line:12.7(1/2")
FDTS71KXE6
7.1 8.0 0.12-0.15 0.12-0.15 Hi:44 Me:38 Lo:36 Unit:194x1300x650 Panel:10x1500x770 Unit:31 Panel:7 Hi:18 Me:15 Lo:12 TS-PSA-39W-E Pocket plastic net x3 (Washable) Liquid line:9.52(3/8") Gas line:15.88(5/8")
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. 2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
Dimensions
All measurements in mm.
Dimension Table
model FDTS45KXE6 FDTS71KXE6 a b c d e f g h i j k m n o
Unit:mm
60 1230 990 555 435 180 115 940 235 205 125 920 245 1200 1290 345 45 1440 1250 675 575 145 100 1200 200 70 110 1180 210 1410 1500 475
35
4")
295~325 63
600 or less
210
Specifications
Model Item FDTQ22KXE6 FDTQ28KXE6 FDTQ36KXE6 Direct blow panel Duct panel Direct blow panel Duct panel Direct blow panel Duct panel Panel Name Panel mode (Option) TQ-PSA-15W-E TQ-PSB-15W-E QR-PNA-14W-ER QR-PNB-14W-ER TQ-PSA-15W-E TQ-PSB-15W-E QR-PNA-14W-ER QR-PNB-14W-ER TQ-PSA-15W-E TQ-PSB-15W-E QR-PNA-14W-ER QR-PNB-14W-ER Nominal cooling capacity kW 2.2 2.8 3.6 Nominal heating capacity kW 2.5 3.2 4.0 Power source 1 Phase 220-240V, 50Hz Cool 0.04-0.05 0.04-0.05 0.04-0.05 Power consumption Heat kW 0.04-0.05 0.04-0.05 0.04-0.05 Sound pressure level dB(A) Hi:38 Lo:33 Hi:42 Lo:39 Hi:38 Lo:33 Hi:42 Lo:39 Hi:38 Lo:33 Hi:42 Lo:39 250x570x570 250x570x570 250x570x570 Exterior dimensions Unit mm HxWxD 35x625x650 35x780x650 35x625x650 35x780x650 35x625x650 35x780x650 35x625x650 35x780x650 35x625x650 35x780x650 35x625x650 35x780x650 Panel Net weight kg Unit:19 Panel:2.5 Unit:19 Panel:3 Unit:19 Panel:2.5 Unit:19 Panel:3 Unit:19 Panel:2.5 Unit:19 Panel:3 Unit:19 Panel:2.5 Unit:19 Panel:3 Unit:19 Panel:2.5 Unit:19 Panel:3 Unit:19 Panel:2.5 Unit:19 Panel:3 Air flow (Standard) CMM Hi:7 Lo:5.4 Hi:7 Lo:6.5 Hi:7 Lo:5.4 Hi:7 Lo:6.5 Hi:7 Lo:5.4 Hi:7 Lo:6.5 Outside air intake Possible Air filter, Qty Pocket Plastic net x1 (Washable) Remote control wired:RC-E3, RCH-E3 wireless:RCN-KIT3-E Installation data Refrigerant piping size mm(in) Liquid line:6.35(1/4") Gas line:9.52(3/8") Liquid line:6.35(1/4") Gas line:12.7(1/2")
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. 2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
36
35
285
Dimensions
All measurements in mm.
Direct blow panel (TQ-PSA-15W-E) Direct blow panel (TQ-PSB-15W-E)
Dimension Table
model TQ-PSA-15W-E TQ-PSB-15W-E a 625 780 b 514 514 c 650 650
Unit:mm
Dimension Table
model QR-PNA-14W-ER QR-PNB-14W-ER a 625 780 b 650 650
Unit:mm
d 580 580
c 580 580
37
4")
Dimensions
All measurements in mm.
FDU71KXE6
Specifications
Model Item Nominal cooling capacity kW Nominal heating capacity kW Power source Cool Power consumption Heat kW Sound pressure level dB(A) Exterior dimensions mm HxWxD Net weight kg Air flow (Standard) CMM Available Static pressure Pa Outside air intake Air filter, Qty Remote control Installation data Refrigerant piping size mm(in)
FDU71KXE6
7.1 8.0 0.29-0.32 0.27-0.30 Hi:41 Lo:37 295x850x650 40 Hi:25 Lo:20
FDU90KXE6
9.0 10.0 1 Phase 220-240V, 50Hz 0.35-0.39 0.34-0.38 Hi:42 Lo:37
FDU112KXE6
11.2 12.5 0.39-0.45 0.34-0.39 Hi:42 Lo:38 350x1370x650
FDU140KXE6
14.0 16.0
Hi:43 Lo:39
63 Hi:34 Lo:27 Standard 50, Max 130 Possible(on Return duct) Procure locally wired:RC-E3, RCH-E3 wireless:RCN-KIT3-E Liquid line:9.52(3/8") Gas line:15.88(5/8")
Hi:42 Lo:33.5
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. 2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
38
Dimensions
All measurements in mm.
Specifications
Model Item Nominal cooling capacity kW Nominal heating capacity kW Power source Cool Power consumption Heat kW Sound pressure level dB(A) Exterior dimensions mm HxWxD Net weight kg Air flow (Standard) CMM Available Static pressure Pa Outside air intake Air filter, Qty Remote control Installation data Refrigerant piping size mm(in)
FDU224KXE6
22.4 25.0 1 Phase 220-240V, 50Hz 0.94-1.03 0.86-0.90 Hi:51 360x1570x830 92 Hi:51 Standard 100, Max 200 Possible(on Return duct) Procure locally wired:RC-E3, RCH-E3 wireless:RCN-KIT3-E Liquid line:9.52(3/8") Gas line:19.05(3/4")
FDU280KXE6
28.0 31.5 0.96-1.05 0.88-0.96 Hi:52
Hi:68
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. 2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
39
4")
Filter kit
UM-FL1E : for 22~56 UM-FL2E : for 71, 90 UM-FL3E : for 112, 140 (option)
LOW NOISE
Specifications
Model FDUM22KXE6 FDUM28KXE6 FDUM36KXE6 FDUM45KXE6 FDUM56KXE6 FDUM71KXE6 FDUM90KXE6 FDUM112KXE6 FDUM140KXE6 Item Nominal cooling capacity kW 2.2 2.8 3.6 4.5 5.6 7.1 9.0 11.2 14.0 Nominal heating capacity kW 2.5 3.2 4.0 5.0 6.3 8.0 10.0 12.5 16.0 Power source 1 Phase 220-240V, 50Hz Cool 0.09-0.11 0.11-0.13 0.14-0.16 0.15-0.17 0.16-0.19 0.24-0.28 0.28-0.32 Power consumption Heat kW 0.09-0.11 0.11-0.13 0.14-0.16 0.15-0.17 0.16-0.19 0.24-0.28 0.28-0.32 Sound pressure level dB(A) Hi:33 Me:31 Lo:28 Hi:34 Me:31 Lo:28 Hi:35 Me:32 Lo:29 Hi:36 Me:33 Lo:30 Hi:37 Me:35 Lo:32 Hi:38 Me:36 Lo:33 Exterior dimensions mm HxWxD Net weight 33 kg Air flow (Standard) CMM Hi:10 Me:9 Lo:8 Available Pa Static pressure Outside air intake Air filter, Qty Remote control Installation data Refrigerant piping size mm(in) Liquid line:6.35(1/4") Gas line:9.52(3/8") 299 x 750 x 635 34 Hi:12 Me:11 Lo:10 Hi:14 Me:12 Lo:11 Standard:50 Max:85 Possible Procure locally wired:RC-E3, RCH-E3 wireless:RCN-KIT3-E Liquid line:6.35(1/4") Gas line:12.7(1/2") Liquid line:9.52(3/8") Gas line:15.88(5/8") 299 x 950 x 635 350 x 1370 x 635
40 59 Hi:18 Me:16 Lo:14 Hi:20 Me:18 Lo:15 Hi:28 Me:25 Lo:22 Hi:34 Me:31 Lo:27 Standard:60 Max:85
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. 2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
Dimensions
All measurements in mm.
FDUM22KXE6
40
FDUM71KXE6, 90KXE6
FDUM112KXE6, 140KXE6
41
4")
Filter kit
QS-FL1E (option)
180mm
Ultra thin design at just 30kg in weight means quick, easy and neat installation in various kinds of room types.
600mm
Drain can be discharged upwards by 600mm from the unit bottom. It allows a piping layout with a high degree of freedom depending on the installation location.
Specifications
Model Item Nominal cooling capacity kW Nominal heating capacity kW Power source Cool Power consumption Heat kW Sound pressure level dB(A) Exterior dimensions mm HxWxD Net weight kg Air flow (Standard) CMM Outside air intake Air filter, Qty Available Static pressure Pa Remote control Installation data Refrigerant piping size mm(in)
FDQS22KXE6
2.2 2.5 0.06-0.07 0.06-0.07
FDQS28KXE6
2.8 3.2
FDQS36KXE6
FDQS45KXE6
FDQS56KXE6
5.6 6.0 0.08-0.09 0.08-0.09
3.6 4.5 4.0 5.0 1 Phase 220-240V, 50Hz 0.07-0.08 0.07-0.08 Rear air return Hi:37 Me:35 Lo:33 Bottom air return Hi:43 Me:41 Lo:39 180 x 940 x 580
28 Hi:9 Me:8 Lo:7.5 Not possible Procure locally Standard:15, Max:30 wired:RC-E3, RCH-E3 wireless:RCN-KIT3-E Hi:11 Me:10 Lo:9
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. 2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
42
Dimensions
All measurements in mm.
43
R410A
Drain up kit
(600mm)
UH-DU-E(option)
Installation Flexibility
570mm
Our leading high technology has realized the best solution for air conditioning in hotels with compact and thin size units and high energy efficiency. In addition, weight is only 20kg.
Quiet operation
257 mm
Control box and drain piping can be installed on both side of the unit and air intake to the unit is available from bottom or back side. Our highest technology can satisfy diverse installation requirements.
Control box
530m
The lowest sound level in the industry can ensure comfortable stay and rest in hotels.
Drain piping
Remote control
Simple remote control
Considering specialized usage in hotel rooms, control buttons are limited only to minimum required functions such as ON/OFF, mode, temperature setting and fan speed. It is really simple and easy to use.
NEW
Wired
RCH-E3
(option)
Specifications
Item Model Nominal cooling capacity kW Nominal heating capacity kW Power source Cool Power consumption Heat kW Sound pressure level dB(A) Exterior dimensions HxWxD mm Net weight kg Air flow (Standard) CMM Available static pressure Pa Air filter, Q'ty Remote control Installation data mm(in) Refrigerant piping size
FDUH22KXE6
2.2 2.5
FDUH28KXE6
2.8 3.2 1 Phase 220-240V, 50Hz 0.050-0.055/0.053 0.050-0.055/0.053 HI: 33 Me: 30 Lo: 27 257x570x530 20 HI: 7 Me: 6.5 Lo: 6 30 Procure locally wired:RCH-E3,RC-E3 wireless:RCN-KIT3-E Liquid line:6.35(1/4") Gas line:9.52(3/8")
FDUH36KXE6
3.6 4.0
Gas line:12.7(1/2")
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. 2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
44
Dimensions
All measurements in mm.
30.8 32.5 83.3 53
Symbol A B C1,C2 D E F Model Gas piping Liquid piping Drain piping Hole for wiring Suspension bolts Inspection hole Duct dimension Content FDUH22KXE6,28KXE6 9.52 38"Flare 6.35 14"Flare FDUH36KXE6 12.7 12"Flare
100 145
12-4
32 27.6
150
150 494
150
32 27.6
Duct dimension
30.8
145.6
Air outlet
32.5
255.8 21 40
C1 A B
66 95.3
30.8 66
F
610
156.8
488
530
62.1
C2
D68
549.2
12-4
21
188.5 148.5
38.2
Air inlet
32 27.5
150
150
32 27.5
G
Bottom plate Able to be located on the back side
View G
In case of Bottom air intake
Holes for tapping screws
30 28.3
37.6
160 200
30
30
12-4
28.5
Air inlet
198.2
160
View G
30
Air inlet
E
Notes The model name label is attached on the fan case inside the air return grille. Prepare the connecting socketVP20on site. As for drain piping, it is possible to choose C1 or C2 When control box is located on the reverse side, Installation space should be modified to new location. Contorl box and Drain hose piece are able to be relocated on the reverse side.
50.5
150
150
18.2
537.6
120
70
15
45
4")
FDK22~56
coming soon
Wireless remote control
FDK71
INNOVATIVE DESIGN
INSTALLATION WORKABILITY
New FDK models adopt the air flow design that's proven to minimise resistance in a CFD analysis to achieve uniform air conditioning to the furthest corners of the room.
259
The new slimmer design allows easy & neat installation even in tight spaces.
Fast
Slow
IMPROVED MAINTAINABILITY
Also included is a new easy clean mechanism where the front panel is opened/closed simply from the bottom to easily access the detachable filters.
Specifications
Model Item Nominal cooling capacity kW Nominal heating capacity kW Power source Cool Power consumption Heat kW Sound pressure level dB(A) Exterior dimensions mm HxWxD Net weight kg Air flow (Standard) CMM Outside air intake Air filter, Qty Remote control Installation data Refrigerant piping size mm(in)
FDK22KXE6
2.2 2.5
FDK28KXE6
2.8 3.2 0.05 0.04
FDK36KXE6
FDK45KXE6
FDK56KXE6
5.6 6.3 0.05 0.05
FDK71KXE6
7.1 8.0 0.09 0.09 Hi:47 Me:43 Lo:39 318 x 1098 x 248 15.5 Hi:21 Me:18 Lo:15
12.5 13 Hi:10 Me:9 Lo:7 Hi:11 Me:9 Lo:7 Hi:14 Me:12 Lo:10 Not possible Polypropylene net x2 (Washable) wired:RC-E3, RCH-E3 wireless:RCN-K-E (for FDK22~56), RCN-K71-E (for FDK71) Liquid line:6.35(1/4") Gas line:12.7(1/2")
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. 2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
46
Dimensions
All measurements in mm.
FDK22~56KXE6
FDK71KXE6
47
4")
Up Rear
210mm
Right
Refrigerant piping can be routed in three directions (rear, up, right) & drain piping in left or right directions, allowing free layout to meet installation conditions.
Slim and sleek design starting at just 28kgs in weight means quick, easy & neat installation.
Specifications
Model Item Nominal cooling capacity kW Nominal heating capacity kW Power source Cool Power consumption Heat kW Sound pressure level dB(A) Exterior dimensions mm HxWxD Net weight kg Air flow (Standard) CMM Outside air intake Air filter, Qty Remote control Installation data Refrigerant piping size mm(in)
FDE36KXE6A
3.6 4.0
FDE45KXE6A
4.5 5.0 0.04-0.05 0.04-0.05 Hi:39 Me:38 Lo:36 210 x 1070 x 690 28 Hi:11 Me:9 Lo:7
FDE56KXE6A
FDE71KXE6A
FDE112KXE6A
11.2 12.5 0.12-0.14 0.11-0.13 Hi:44 Me:41 Lo:39
FDE140KXE6A
14.0 16.0 0.14-0.15 0.13-0.14 Hi:46 Me:44 Lo:43
5.6 7.1 6.3 8.0 1 Phase 220-240V, 50Hz 0.08-0.09 0.07-0.08 Hi:41 Me:39 Lo:37 210 x 1320 x 690 37 Hi:18 Me:14 Lo:12 Not possible Pocket Plastic net x2 (Washable) wired:RC-E3, RCH-E3 wireless:RCN-E-E
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. 2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
48
Dimensions
All measurements in mm.
C1,C2
10 290 (Suspension bolts pitch) 135 68 5 410
D
145
52
40
B A
108
Note) The slope of drain piping inside the unit must take decline of 10mm.
53
40
990 1070
40
15 20 100
60
C1,C2
Air supply
Symbol A B C 1,2 D E F G
Content Gas piping Liquid piping Drain piping Hole for suspension bolt Back cutout Top cutout Hole for drain piping (for left back)
31
12.7 (1/2") (Flare) 6.35 (1/4") (Flare) VP20 (I.D.20) (M10 or M8) PE cover Plate cover (Knock out)
173
210
215
53 109
27
27
20
12
175
19
308
100 or more
300 or more
F
150 or more 5 or more
Right side cutout
G E
Note(1)The model name label is attached on the fan casing inside the air return grille.
C2
76 Air return grille
75
A C1
110 135
Obstacle Make a space of 4000 or more between the units when installing more than one.
C1,C2
FDE71KXE6A
24 1272 (Suspension bolts pitch) 24
D
145 52
40
B A
108
Note)The slope of drain piping inside the unit must take decline of 10mm.
Symbol A B C 1,2 D E F G Content Gas piping Liquid piping Drain piping Hole for suspension bolt Back cutout Top cutout Hole for drain piping(for left back)
10
53
40
1240 1320
40
15 20 100
60
Air supply
C ,C
15.88 (5/8") (Flare) 9.52 (3/8") (Flare) VP20 (I.D.20) (M10 or M8) PE cover Plate cover (Knock out)
173
210
215
53 109
27
27
31
20
12
175
19
308
100 or more
300 or more
F
150 or more 5 or more
Right side cutout
G E
Note(1)The model name label is attached on the fan casing inside the air return grille.
C2
76
75
A C1
110 135
Obstacle
Make a space of 4500 or more between the units when installing more than one.
C1,C2
FDE112KXE6A, 140KXE6A
24 1572 (Suspension bolts pitch) 24
D
145 52
250
255
40
B A
108
Note) The slope of drain piping inside the unit must take decline of 10mm.
10
53
40
1540 1620
40
15 20 100
60
C1,C2
Symbol A B C1,2 D E F G
Content Gas piping Liquid piping Drain piping Hole for suspension bolt Back cutout Top cutout Hole for drain piping (for left back)
15.88 (5/8") (Flare) 9.52 (3/8") (Flare) VP20 (I.D.20) (M10 or M8) PE cover Plate cover (Knock out)
173
53 109
27
Air supply
27
31
20
300 or more 308 100 or more
0 12
175
19
F
150 or more 5 or more Right side cutout
G E
Note(1)The model name label is attached on the fan casing inside the air return grille.
C2
A C1
110 135
Obstacle
Make a space of 5000 or more between the units when installing more than one.
49
4")
Floor Standing (with casing) FDFL Floor Standing (without casing) FDFU
Model No. FDFL28KXE6 FDFL45KXE6 FDFL71KXE6 FDFU28KXE6 FDFU45KXE6 FDFU56KXE6 FDFU71KXE6
FDFL
Specifications
Item Model Nominal cooling capacity kW Nominal heating capacity kW Power source Cool Power consumption Heat kW Sound pressure level dB(A) Exterior dimensions mm HxWxD Net weight kg Air flow (Standard) CMM Air filter, Qty Remote control
FDFL28KXE6
2.8 3.2
FDFL45KXE6
4.5 5.0
FDFL71KXE6
7.1 8.0
FDFU28KXE6
2.8 3.2 1 Phase 220-240V, 50Hz
FDFU45KXE6
4.5 5.0
FDFU56KXE6
5.6 6.3
FDFU71KXE6
7.1 8.0
0.09-0.10 0.09-0.10 Hi:43 Me:41 Lo:40 630x1077x225 630x1362x225 32 Hi:18 Me:15 Lo:12
40 25 Hi:14 Me:12 Lo:10 Hi:12 Me:11 Lo:10 Hi:18 Me:15 Lo:12 Polypropylene net x1 (Washable) wired:RC-E3, RCH-E3 wireless:RCN-KIT3-E Liquid line:6.35(1/4") Gas line:12.7(1/2")
Liquid line:6.35(1/4") Liquid line:6.35(1/4") Liquid line:9.52(3/8") Liquid line:6.35(1/4") Installation data Refrigerant piping size mm(in) Gas line:9.52(3/8") Gas line:12.7(1/2") Gas line:15.88(5/8") Gas line:9.52(3/8")
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. 2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
50
Dimensions
All measurements in mm.
FDFL
Dimension Table
model FDFL28KXE6, 45KXE6 FDFL71KXE6 a 786 1071 b 1196 1481 c 750 1035
Unit:mm
d 806 1091
FDFU
Dimension Table
model FDFU28KXE6, 45KXE6, 56KXE6 FDFU71KXE6 a 786 1071 b 810 1095 c 722 1007 d 750 1035
Unit:mm
e 806 1091
51
4")
Air conditioning and intake of outdoor air are in the same system
Outdoor Air processing unit can be connected in a KX6 system as one of indoor unit series and can create fresh and comfortable air supply together from our high advanced technology.
indoor unit office outside air supply corridor refresh room, rest room
Compact design
Compact design at just 360mm in height, high static pressure of 200Pa and the industry's lowest noise level can meet various kind of installation location for office, refresh room, restroom and kitchen of restaurant etc.
exhaust air
outdoor air
(1) This unit is the specific unit for processing the outdoor air temperature closer to the room temperature. For conditioning the room temperature a dedicated air-conditioner is required additionally. (2) This unit monitors the outdoor air temperature and controls thermostat ON/OFF at the setting temperature by the remote controller, which indicates the outdoor air temperature for controlling thermostat ON/OFF. When thermostat is turned OFF, the operation is changed to the fan mode so that unprocessed outdoor air will be blown into the room directly. Therefore place the air outlet port or orient the air outlet direction not to blow air directly to persons in the room, especially in the small room such as a restroom and/or sanitary hot water supplying room. (3) It is strictly prohibited to monitor the room temperature by switching to the thermistor at remote controller side and/or the optional remote thermistor. Otherwise dew formation at air outlet port and/or dew dripping may occur during cooling operation due to the lower outdoor air temperature. Therefore keep the remote controller of this unit in place closer to the administrator so as not to be touched it freely by the end user. (4) Dehumidifying operation with this unit is prohibited. (5) When handing over this unit to the end user, make sure to explain sufficiently about the foregoing cautions, the installation place and usage of remote control for this unit and the location of the air outlet.
52
Combination
The total capacity of FDU-F is 50~100% of outdoor capacity
The total capacity of FDU-F and dedicated air-conditioners is 50~100% of outdoor capacity and max quantity of FDU-F should be below 30% of outdoor unit capacity.
[A]
10HP FDU850FKXE6 (5HP) FDU850FKXE6 (5HP)
[B]
18HP
FDU850FKXE6 (5HP)
6HP
6HP
SAF
Outside
53
4")
Specifications
Item Model Nominal cooling capacity kW Nominal heating capacity kW Power source Power Cool kW consumption Heat Sound pressure level dB(A) Exterior dimension mm HxWxD Net weight kg Air flow (Standard) CMM CMH Available static pressure Pa Remote control Installation data mm Refrigerating piping size (in)
FDU500FKXE6
9.0 4.2 0.11 0.11 43 360x820x830 48 8.5 510
FDU850FKXE6
14.0 7.0
FDU1300FKXE6
22.4 10.9
FDU1800FKXE6
28.0 14.8 0.31 0.31 51 360x1570x830
1 Phase 220-240V, 50Hz 0.16 0.16 46 360x1200x830 62 14 840 82 22 1320 Max:200 wired:RC-E3 wireless:RCN-KIT3-E Liquid line:9.52(3/8") Gas line:19.05(3/4") 0.27 0.27 48
84 30 1800
1. Cooling capacity is measured at 33CDB/28CWB (68%RH) and heating capacity is measured at 0CDB/2.9CWB under OA processing mode. 2. Operation range of outdoor air temperature is 20C-40CDB in cooling, and 0C-24CDB in heating. 3. Indicated sound level value is measured in anechoic chamber. Actual operation value may become higher due to the surrounding conditions 4. Indicated sound level values are measured at 200Pa static pressure. Indicated air flow volume is measured at 200Pa static pressure. 5. Total connection capacity of dedicated air conditioning units and OA processing units should be within 50% to 100% of the outdoor unit capacity. Total connection capacity of OA processing units should not exceed 30% of outdoor unit capacity. 6. OA processing unit can be used alone, but connecting number of OA processing units should not exceed two (2). The connection capacity of OA processing units should be within 50% to 100% of outdoor unit capacity. 7. When optional fan control kit (U-FCRB) is used and operated at 100Pa static pressure, the sound level value becomes 5dB(A) lower than the above indicated value.
Dimensions
All measurements in mm.
FDU500FKXE6
Control box
12-M5 screw
12-M5 screw
Below
Installation space
Installation space
or more
or more
or more
Plan view
or more
Front view
Symbol
Content
Slab Ceiling Service space or more Piping space (Service from below) (Service from side and below)
54
or more
Gas piping Liquid piping Drain piping connection Power supply wiring connection Suspension bolt Inspection Opening Inspection Opening
FDU850FKXE6
Control box
16-M5 screw
12-M5 screw
Below
or more
or more
Front view
or more
FDU1300FKXE6, FDU1800FKXE6
Suspension bolts pitch
or more
Service space
Gas piping Liquid piping Drain piping connection Power supply wiring connection Suspension bolt Inspection Opening Inspection Opening
Control box Duct connection port for outdoor air inlet Above 20-M5 screw Port for air outlet
20-M5 screw
Below
Installation space or more or more Installation space Slab Ceiling or more Piping space (Service from side) (Service from below) or more Service space Service space (Service from side and below) Front view or more or more Plan view
Symbol
Content
Gas piping Liquid piping Drain piping connection Power supply wiring connection Suspension bolt Inspection Opening Inspection Opening
55
4")
Capturing this waste energy, means the heating/ cooling requirements of the building are reduced, so smaller size plant can be selected, savings can be made in long term energy consumption, and carbon emissions are reduced. The inclusion of the SAF energy recovery ventilation units in the building design, will reduce the total amount of carbon emissions.
EA (Exhaust Air)
RA (Room Air)
OA (Outside Air)
SA (Supply Air)
Specifications
Item Model Power source Exterior dimensions mm Height x Width x Depth Exterior appearance Power input W Running current A Enthalpy Cooling exchange UHi efficiency Heating Temperature exchange efficiency Enthalpy Cooling exchange Hi efficiency Heating Temperature exchange efficiency Enthalpy Cooling exchange Lo efficiency Heating Temperature exchange efficiency Motor & Qty kW Air handling equipment Fan type & Qty UHi Air flow Hi m3/h Lo UHi Available static pressure Hi Pa Lo
SAF250E4
270x882x599 99-114 0.46-0.48 63 70 63 70 66 73 77 0.02x2 250 250 170 90 80 37
SAF350E4
170x882x804 124-137 0.59-0.60 66 69 66 69 69 71 77 0.044x2 350 350 280 95 65 42
SAF500E4
1 Phase 220-240V, 50Hz 270x962x904 Galvanised steel sheet 169-188 0.79-0.81 62 67 75 62 67 75 77 67 75 0.062x2 Sirocco fan x 2 500 500 370 105 70 38 Protection for element (Washable) PS400
SAF800E4
388x1322x884 309-359 1.48-1.50 65 71 65 71 68 74 76 0.117x2 800 800 650 140 110 70
SAF1000E4
388x1322x1135 360-399 1.85-1.93
Capacity
Air filter
56
Dimensions
All measurements in mm.
SAF250E4,350E4,500E4
SAF800E4
SAF1000E4
Installation reference
Pipe Hood Outside Intake Duct Ceiling Suspension Bolt Supply Air Duct
SA
(Supply Air)
RA
(Room Air)
OA
EA
Dimension table
NO.
1 2 3 4 5 6 7 8 9 10 11
Unit:mm
Name
Frame Adaptor Electrical Equipment Box Inspection Cover Fan Motor Heat Exchange Element Filter Damper Damper Motor Ceiling Suspension Fixture
Quantity
1 4 1 1 2 2 2 2 1 1 4
Material
Zinc-plated steel ABS Resin Zinc-plated steel ABS Resin
Remarks
Model
SAF250E4 SAF350E4 SAF500E4
a
142 162 202
b
810 810 890
c
599 804 904
d
315 480 500
e
655 860 960
Model
SAF250E4 SAF350E4 SAF500E4
f
219 219 246
g
164 164 210
h
144 144 194
i
882 882 962
j
95 95 107
Flame Retardant Paper + Plastic Air to air Heat Exchanger Non-woven Cloth Collection Efficiency Gravimetric Method 82%
Zinc-plated Steel
Note(1) An inspection port is needed for cleaning the heat exchanger and filter 1 or 2 times a year.
57
R410A
Changeable set temperature ranges RC-E3 allows the upper and lower limits of a set temperature range to be specified separately. By adjusting a set temperature range, you can ensure energy saving air conditioning by avoiding excessive cooling or heating.
NEW
Considering specialized usage in hotel rooms, control buttons are limited only to minimum required functions such as ON/OFF, mode, temperature setting and fan speed. It is really simple and easy to use.
Up to 16 units It can control up to 16 units individually, with pressing the AIR CON No. button. AUTO restart This function allows starting the air conditioner automatically when power supply is restored after power failure or by turning on the power switch.
Thermistor (option)
RCN-KS-E, RCN-K71-E
RCN-T-36W-E, RCN-TC-24W-ER
RCN-E-E
NEW
NEW
RCN-KIT3-E
SC-THB-E3
In case sensor in the indoor units or the remote control sensor can not sense the room temperature correctly, or individual remote control in each room is not required but only censor is required (as when center control system is in place), install SC-THB-E3 at proper place in the rooms.
coming soon
58
<Control System>
SUPERLINKMHI has now combined simplicity of installation with our highly sophisticated Superlink- control system, to offer building owners and occupiers a comprehensive control and management system, while providing complete commissioning and service maintenance assistance for installers and service engineers. The Superlink- network utilises two wire, non-polar cable - for further details of wiring. Superlink- is an advanced high speed data transmission system that can connect up to 128 indoor units and 32 outdoor units as a network. MHI offers a wide range of control options for the Superlink- network to suit any application large or small, as well as connection to new or existing building management systems. Individual MHI split systems can also be integrated on to the Superlink- network using SC-ADN-E.
3-core + earth cable for connecting indoor and outdoor units SRK/SRF-ZIXseries SC-BIKN-E
One-to-one
Wireless
59
4")
<Central Control>
SC-SL1N-E
Start/stop control of up to 16 indoor units either individually or collectively. Simple centralised control. 1. The SC-SL1N-E is connected to the Superlinknetwork via 2-core, non-polar wires (AB connection). 2. It will monitor and control the start/stop function of up to 16 units, with the sixteen operation button. 3. The unit or group numbers in operation or in need of service are displayed with an LED. 4. Collective start/stop is also available through the simultaneous on/off button. 5. Up to 12 SC-SL1N-E units can be connected to a Superlink- network (consisting of up to 128 indoor units). 6. If a power failure occurs, the SC-SL1N-E will resume the operation of the system according to a stored operation condition, once power is restored. 7. This central control can be connected anywhere on the Superlink- network, at indoor units as well as outdoor units. This can substantially reduce the amount of electrical installation work. This feature is common to both SC-SL1N-E and SC-SL2N-E controls.
SL1N-E
More than one unit (up to 16) can be controlled for individual or collective start/stop operation and indication of unit statuses such as in operation or in need of service. Outer dimensions: H120 x W120 x D15+62*mm. 62* is the measurement including the part contained in a recess.
SC-SL2N-E
Central control of up to 64 indoor units including weekly timer function as standard. 1. The SC-SL2N-E is connected to the Superlinknetwork via 2-core, non-polar wires (AB connection). 2. It will monitor and control the start/stop function of up to16 units, or 16 groups of units, with the sixteen operation buttons. 3. It also monitors and controls the following functions for individual units, groups of units or the complete network: operation mode, set point temperature, return air temperature, louvre position, error code. 4. The unit or group numbers in operation or in need of service are displayed with an LCD. 5. Collective start/stop is also available through the simultaneous on/off button. 6. If a power failure occurs, the SC-SL1N-E will resume the operation of the system according to a stored operation condition, once power is restored. 7. The SC-SL2N-E can be connected to an external timer to facilitate timed on/off cycles. 8. The number of SC-SL1N-E and SC-SL2N-E units connected to one network are detailed on the table below. 9. This central control can be connected anywhere on the Superlink- network, at indoor units as well as outdoor units. This can substantially reduce the amount of electrical installation work. This feature is common to both SC-SL1N-E and SC-SL2N-E controls.
SL1N-E
An SC-SL2N-E performs the start/stop control, monitoring and mode setting of up to 64 units. It is a high quality air conditioner control system that allows up to 64 indoor units to be freely grouped into 1 to 16 groups. It allows not only the start/stop control but also the monitoring, display of operation statuses such as in operation or in need of service and mode setting such as switching of operation modes of connected units collectively, by group or individually. Outer dimensions: H215 x W120 x D25+35*mm. 35* is the measurement including the part contained in a recess.
( 2) Number of units in combination of SC-WGWN-A/B, SC-BGWN-A/B, SC-LGW-A, SC-SL3N-AE/BE, SC-SL2N-E and SC-SL1N-E
Connectable number of controls in one superlinkSC-WGWN-A/B or SC-BGWN-A/B or SC-LGWN-A 1 SC-SL1N-E 0-4 SC-SL3N-E-AE/BE 0-1
Regarding previous Superlink, refer to Technical Manual '06 SC-T-111, '08 SC-T-119.
Regarding previous Superlink, refer to Technical Manual '06 SC-T-111, '08 SC-T-119.
60
SC-SL3N-AE/BE
MHI introduces the full colour touch screen central control SC-SL3NAE/BE, with 7 inch interactive LCD display. Offers control, monitoring, scheduling and service/maintenance functions for up to 128 indoor units. Indoor units can be controlled, scheduled, monitored and interrogated either individually, as groups or as blocks of groups with the following functions:
NEW
Collective stop signal input
40
SLA3R-BX
Control Run/Stop Mode (cool/heat/fan) Set temperature Operation permitted/prohibited Fan speeds Air direction Filter reset Filter sign Maintenance (1, 2 or back-up) Breakdown
Monitoring Operating state Mode Set temperature Room temperature Operation enabled Fan speed Air direction
Administration/Service Block definition Group definition Unit definition Time and date setting Alarm history Energy consumption calculation period Energy consumption cumulative operation time Demand control Emergency stop Power failure recovery control
Model
SC-SL3N-AE/SC-SL3N-BE
0 ~ 40oC 1 Phase 100-240V 50/60Hz 18W 162mm x 240mm x 108mm 2.0kg up to 128 units Colour LCD, 7 inches wide 3 systems 8-point pulse width 100ms or more 1 point non-voltage a contact input continuous input (closed, forced stop) 1 point non-voltage a contact input continuous input (closed, demand control) 1 point maximum rated current 40mA, 24 V During full stop; Open. If even one unit is operating; Closed 1 point maximum rated current 40mA, 24 V Normal; closed. If even one unit is abnormal; Open
SC-SL3N-BE
Method of data saving Calculation software Air-conditioner power proportional distribution pulse input Connecting indoor units number (Maximum) USB Standard 8 systems 128
* The receiving side power supply is DC 12V (10mA). The air conditioning charges calculations of this unit are based on OIML, the international standard. * In case embodying in a wall, please be sure to special box SLA3R-BX (option).
61
4")
Additional engineering service cost etc. is required. Please consult your dealer when using this central control.
64 units
Cell
PC requirements: Windows 2000 or Windows XP. Monitor resolution 1024 x 768. Web browser requirements: Internet Explorer 6.0 or later.
Production by order
48 cells SC-ADN-E
Cell
Additional engineering service cost etc. is required. In case of SC-BGWN-B, communication test by qualified person regarding electric cost calculation function is required before commissioning. Please consult your dealer when using this gateway.
Production by order
SC-LGWN-A is an interface device that converts MHIs Superlink- communication data to LonWorks code. Control and monitoring functions of the a/c system for up to 96 indoor units can be integrated to a central control point via the building management system network.
SUPERLINK- No. 2 system LonWorks network (FTT-10) Network for lighting SC-ADN-E 48 units
Additional engineering service cost etc. is required. Please consult your dealer when using this gateway.
62
Mechanical chamber
Indoor unit
Indoor unit
Indoor unit
Indoor unit
Indoor unit
Indoor unit
63
KX4
4")
Production by order Superlink models (not Superlink- models) The KX4 heat pump 2-pipe systems offer high performance VRF
for applications that require either cooling only or heating only.
Connect up to 20 indoor units/up to 130% capacity. High efficiency with COP (in cooling) from 3.6 to 3.9.
Outdoor unit Height difference 50m(outdoor unit above) 40m(outdoor unit below) Max height difference between indoor units: 15m
-10
Range of operation
50
Indoor unit
+43C
40
Air
discharge duct
From the first branch to the furthest indoor unit: 40m Furthest indoor unit: 160m
Indoor unit
30
Cooling
20
+15.5C
10
Indoor unit
-5C
Heating
louvre
Air
outdoor unit
-20
-20C
In case an outdoor unit is installed inside the building and outdoor exhaust air is discharged to outside the building through duct system, these units have necessary minimum external static pressure (50Pa).
Specifications
Item Nominal horse power Power source Nominal capacity Model
FDCA224HKXE4D
8HP 22.4 25.0 5.70 5.98 9.6-8.8 9.6-8.8
FDCA280HKXE4D
10HP 3 Phase 380V-415V, 50Hz 28.0 31.5 5 8.26 8.06 13.6-12.4 13.3-12.4 1690x1350x720 245 11.5 57/58 9.52(3/8") 22.22(7/8") 20~114 16
FDCA335HKXE4D
12HP 33.5 37.5 9.53 9.84 15.5-14.2 16.3-14.9
Cooling kW Heating A Starting current Cooling Power kW Electrical characteristics consumption Heating Operating Cooling A current Heating HxWxD Exterior dimensions mm Net weight kg R410A kg Refrigerant charge Cooling/Heating dB(A) Sound pressure level Liquid line mm(in) Refrigerant piping size Gas line % Capacity control Number of connectable indoor units
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. 2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
64
Dimensions
All measurements in mm.
250 175 850 1000 250 175 74.5 85 101 232 D(lower) 185
Rear
C 594 232
Anchor bolt positions for I
K B
58.5
19
F I
I F
726
647
85
57
95 140.5
141
75 142.5 234
58.5
19
Air intake
G
148 410 352 158 530 342 235
1690 797.8
126.2
720
1350
7-segment display inspection port 682 Signal wire terminal block Terminal block for power cable connection
K B A C (front)
166 169 211 259 291.6
120
22
80.5 71
C (right)
C (rear)
L
44.7
84
D (left)
104.9
95
90
D (right)
D (front)
Mark A B C D F G H K* L
Item Service valve connection (gas side) Service valve connection (liquid line) Refrigerant pipe draw-out port Power cable draw-in port Anchor bolt hole Drain hose hole Drain discharge port Oil-equalising pipe joint Sling holes for haulage or hoisting
For refrigerant piping, please refer to the unit specifications.
Intake
Installation example
Dimensions
L2
L3
Wall height H3 L4
Intake
Wall height H2
Intake
Wall height H4 Wall height H1
L1 L2 L3 L4 H1 H2 H3 H4
Service space
Intake
Notes: (1) The unit must be fixed with anchor bolts. (2) Leave a 2m or larger space above the unit. (3) The unit name plate is attached on the lower right corner of the front panel. (4) The ports for refrigerant pipe and power cable penetrations are covered with half-blanks. Please cut off a half-blank with nippers in using these ports. (5) Use a 88 port for refrigerant pipe connection. (6) Anchor holes marked L J (four holes for M10) are for a renewal installation.
Installation example
Dimensions
L1
20
Instruction plate
6 86.1
172
172
80
L3
Wall height H2 Wall height H4
L1
L6 L4
L2
L5
L2 L3 L4 L5 L6 H1 H2 H3 H4
No restrictions No restrictions
65
4")
Creed
We strongly believe that the customer comes first and that we are obliged to be an innovative partner to society. We base our activities on honesty, harmony, and a clear distinction between public and private life. We shall strive for innovative management and technological development from an international perspective.
MHIs creed was established based on The Three Corporate Principles shared by the Mitsubishi Group from the companys beginnings. In the spirit of this creed, MHI continues its efforts to fulfil its three corporate social responsibilities (CSRs): corporate governance and compliance, the environment, human rights and labour, and contribution to society through business activities.
MISSION
Supply all areas of the world with highly efficient, clean energy
MISSION
VISION
MHI, a premier global organization.
MHI is a global enterprise with a vision for sustainable growth, living up to the trust of customers with outstanding technology, and helping people worldwide lead safe and fulfilling lives. A company with expertise in all modes of transportation, from land and sea to air and space, and in the defence sector
Industries
MISSION
Help people lead fulfilled lives
MISSION
Support manufacturing activities worldwide
66
The KX6 product range has been developed in compliance with the Mitsubishi Heavy Industries Policy on the Environment.
In order to make the sustainable development of society possible, a basic policy on environmental matters has been established.
Pursuant to the express provision of Section 1 of its creed that We strongly believe that customers come first and that we are obligated to be an innovative partner to society, MHI shall, as a matter of primary importance, strive, through its R&D, manufacturing and other business activities, to play a useful role in the development of society. To this end, while remaining aware that a business enterprise is a member of society, MHI shall endeavour, in all aspects of its business activities, to reduce the burden on the environment and shall concentrate and fully utilise its technological capabilities for the development of technologies and products that will protect the environment, thus contributing to the establishment of a society in which sustainable development is possible.
In order to realise its basic policy, MHI has set the following seven conduct guidelines.
1. Recognise that environmental protection is top priority in the companys operations, and encourage the entire company in its endeavours to protect and improve the environment. 2. Define roles and responsibilities regarding environmental protection by developing and maintaining a corporate organisation designated for environmental protection, and create and implement corporate policies and procedures on environmental matters. 3. Endeavour to reduce the burden on the environment by preventing pollution, saving resources, saving energy, reducing waste, reusing materials, and recycling in all aspects of the companys business activities in R&D, designing, procurement of materials, manufacturing, transportation, use, service and disposal. 4. Endeavour to develop and provide advanced, highly reliable, unique technologies and products that contribute to solving environmental and energy problems. 5. Comply with national and local environmental laws and regulations, beyond mere compliance by enacting, implementing and evaluating voluntary standards where necessary, and to endeavour to continuously improve and promote environmental protection activities by establishing environmental goals and targets. 6. Endeavour to protect the environments of foreign countries by carefully examining the consequences of the companys overseas business operations and the exportation of its products, and to become actively involved in technological co-operation overseas in areas of environmental protection. 7. Provide environmental training and other programs to enhance the environmental awareness of all company employees, and take steps to expand public relations activities, such as providing environment-related information to the public and social contribution activities.
Europe
Major subsidiaries 13
Russia
Overseas offices & representatives 1
Asia
Overseas offices & representatives Major subsidiaries
Oceania
Major subsidiaries 1
67
global activity
On the land and sea, in the sky and even in space, MHIs stage of operations is expanding limitlessly. We manufacture more than 700 different products which support various industrial and civil activities in both domestic and international markets. Ships, steel structures, power systems, machinery for both industrial and general use, air-conditioners, pollution reduction and environmental control systems, aerospace systems the MHI product lines which create rich and comfortable living environments, are as harmonious as an orchestra. What creates this harmony is MHIs general technological expertise developed over more than a century of hard work. We are highly esteemed in the world for providing high quality products through untiring technological research and development. From new energy development and environmental concerns to the exploration of space, with the advent of the 21st century MHI is confronting a variety of issues to ensure the realisation of a society in which there is harmony between mankind and technology.
Ultra-High Steel Stacks Refuse Incineration Plants Night Soil Treatment Plants Electrostatic Precipitators Flue Gas Desulfurization System Fluidized Incinerators CFC Collecting Equipment
Crude Oil Storage Barges LNG Tanks Boilers & Turbines Oil Production Plants Contra-Rotating Propellers Thermal Power Plants Combined Cycle Plants Fuel Cells Water Turbines Wind Turbines Geothermal Power Plants PWR Nuclear Power Plants Uranium Enrichment Equipment FBRs Co-Generation Systems
Spillway Radial Gates Steel Bridges Penstocks Desalination Plants Physical Distribution Equipment Engines
RESO
C LO
S URCE
Unloader & Container Cranes Mechanical Parking Facilities Integrated Automated Storage Systems Rubber & Tyre Machinery Skyrails Monorail Cars New Transportation Systems Passenger Boarding Bridges
Toll Collection Machine Systems Forklift Trucks Helicopters Aircraft Railway Maintenance Equipment LNG Carrier Container Ships
AL
V EN
TR
AN
VE DE P LO
TA TIO
SP
IRO
/ENER
OR
NM EN
M T EN
N
GY
68
Chemical Plants Wind Tunnel/Experiment Equipment Casting Machines Strip Mill Cement Plant Stepless Variable Speed Gears Industrial Robots Injection Moulding Machines Pulp & Paper Machinery Corrugation Machines Box Making Machines Machine Tools
Ceiling Recess Packaged Air Conditioners Automotive Air Conditioners Residential Use Split Air Conditioners Refrigeration Units Dry Cleaning Machines Food Machinery Cruise Ships Multi-purpose Dome Stage Machinery Systems
Oceanographic Research Ships Deep Submergence Research Vehicles Communications Satellite Rockets Space Transportation Rockets & Engines
YLE
EST
ST
EM
INDUS T
IN FO RM
SU RE
V DE
LEI
EL
E PM
AT
NT
N EFE
CE
Submarines Naval Vessels Jet Fighters Helicopters Missiles Tanks & Infantry Fighting Vehicles
RIAL
/LIF
IO
SY
69
Refrigerant leakage
The refrigerant (R410A) used for Air conditioner is non-toxic and inflammable in its original state. However, in consideration of a state where the refrigerant leaks into the room, measures against refrigerant leaks must be taken in small rooms where the tolerable level could be exceeded. Take measures by installing ventilation devices, etc.
Snow prevention
Install a snow-prevention hood so that the snow does not obstruct the air intake port or enter and freeze in the outdoor unit.
Snow piling
In areas with heavy snow fall, the piled snow could block the air intake port. In this case, a frame that is 50cm or higher than the estimated snow fall must be installed underneath the outdoor unit.
Safety Precautions
Air-conditioner usage target
The air-conditioner described in this catalog is a dedicated cooling/heating device for human use. Do not use it for special applications such as the storage of foodstuffs, animals or plants, precision devices or valuable art, etc. This could cause the quality of the items to drop, etc. Do not use this for cooling vehicles or ships. Water leakage or current leaks could occur.
Installation
Always commission the installation to a dealer or specialist. Improper installation will lead to water leakage, electric shocks and fires. Make sure that the outdoor unit is stable in installation. Fix the unit to stable base.
Usage place
Do not install in places where combustible gas could leak or where there are sparks. Installation in a place where combustible gas could be generated, flow or accumulate, or places containing carbon fibers could lead to fires.
Before use
ISO 14001
BIWAJIMA PLANT
Mitsubishi Heavy Industries, Ltd. Air-conditioning & Refrigeration Systems Headquarters
HB91-09KX01E-A-0
December 2008(2B)R
Because of our policy of continuous improvement, we reserve right to make changes in all specifications without notice.
Printed in Japan