Proportional Relief Valves Rzmo-Aes and Hzmo-A
Proportional Relief Valves Rzmo-Aes and Hzmo-A
Proportional Relief Valves Rzmo-Aes and Hzmo-A
(1) Serial communication interface always present, also for -BC, -BP and -EH options
F065
3 HYDRAULIC CHARACTERISTICS (based on mineral oil ISO VG 46 at 50 °C)
Hydraulic symbols
4 MAIN CHARACTERISTICS
2
1 = RZMO-A; RZMO-AE; RZMO-AES; HZMO-A
Pressure at port P [bar]
Note:
The presence of counter pressure at port T 1
can affect the effective pressure regulation.
Flow [l/min]
5.4 Dynamic response
The response times in section have to be considered as average values.
The pressure variation in consequence of a modification of the reference input signal to the valve is affected by the stiffness of the hydraulic circuit:
greater is the stiffness of the circuit, faster is the dynamic response.
6 GENERAL NOTES
RZMO and HZMO proportional valves are CE marked according to the applicable Directives (e.g. Immunity/Emission EMC Directive and Low Voltage Directive).
Installation, wirings and start-up procedures must be performed according to the general prescriptions shown in table F003 and in the installation notes
supplied with relevant components.
The electrical signals of the valve (e.g. monitor signals) must not be directly used to activate safety functions, like to switch-ON/OFF the machine’s safety
components, as prescribed by the European standards (Safety requirements of fluid technology systems and components-hydraulics, EN-982).
MAIN CONNECTOR
7 PIN - STANDARD
SCALE BIAS
(driver view)
RAMPS
100 RD 쩨
ON 130 RU 쩨
ON 160
B1 쩨
ON 200 (Standard)
ON ON 230 S1 쩨
ON ON 270
ON ON ON 300 B1: positive bias adjust
ON ON ON 380 S1: positive scale adjust
ON ON ON 430
RU: ramp for increasing reference signal
ON ON ON 470
RD: ramp for decreasing reference signal
ON ON ON ON 500
SW: dither frequency selector (see table beside)
The dither frequency is factory pre-
set at 200 Hz and its regulation may
be adjusted after contact with Atos
technical department
A V+ Power supply 24 VDC for solenoid power stage and driver logic Input - power supply
B V0 Power supply 0 VDC for solenoid power stage and driver logic Gnd - power supply
AGND Ground - signal zero for MONITOR signal Gnd - analog signal
C (1)
ENABLE Enable (24 VDC) or disable (0 VDC) the driver (for /Q option) Input - on/off signal
D INPUT+ Reference analog input: 0÷+10 VDC maximum range (4÷20 mA for /I option)
Input - analog signal
E INPUT - Normal working range 0÷+10 VDC (4÷20 mA for /I option)
F MONITOR Monitor analog output: 0÷+5 VDC maximum range; 1 V = 1 A Output - analog signal
G EARTH Internally connected to the driver housing
Note: (1) with /Q option ENABLE signal replaces AGND on pin C; MONITOR signal is reffered to pin B.
A minimum time of 60ms to 160ms have be considered between the driver energizing with the 24 VDC power supply and when the valve is ready
to operate. During this time the current to the valve coils is switched to zero
F065
11 DIGITAL INTEGRAL DRIVERS -AES - OPTIONS
Following options are available to adapt standard execution to special application requirements:
11.1 Option /Q
To enable the driver, supply 24Vdc on pin C referred to pin B: when the enable signal is set to zero the valve status is software selectable, by factory
default the valve functioning is disabled (zero current to the solenoid) but the driver current output stage is still active. For the complete list of selectable
status, see tab. G115.
11.2 Option /Z
It provides, on the 12 pin main connector, the following additional features:
Logic power supply
Separated power supply for the solenoid (pin 1, 2) and for the digital electronic circuits (pin 9, 10).
Cutting solenoid power supply allows to interrupt the valve functioning but keeping energized the digital electronics thus avoiding fault conditions of the
machine fieldbus controller. This condition allows to realize safety systems in compliance with European Norms EN13849-1 (ex EN954-1).
Enable Input Signal
To enable the driver, supply 24Vdc on pin 3 referred to pin 2: when the enable signal is set to zero the valve status is software selectable, by factory
default the valve functioning is disabled (zero current to the solenoid) but the driver current output stage is still active. For the complete list of selectable
status, see tab. G115.
Fault Output Signal
Fault output signal indicates fault conditions of the driver (solenoid short circuits/not connected, reference signal cable broken for 4÷20mA input, etc.).
Fault presence corresponds to 0 VDC, normal working corresponds to 24VDC (pin 11 referred to pin 2): Fault status is not affected by the Enable input signal.
COMMUNICATION CONNECTOR
MAIN CONNECTOR 5 PIN 5 PIN
7 PIN - STANDARD PROFIBUS DP (-BP) CANopen (-BC)
(driver view)
SCALE BIAS
(driver view)
LINEARIZATION RAMPS
12 PIN - OPTION /Z
5 PIN
Serial (-PS)
(driver view)
(driver view)
COMMUNICATION CONNECTOR
MAIN CONNECTOR 4 PIN (input)
7 PIN - STANDARD EtherCAT (-EH)
(driver side)
(driver side)
SCALE BIAS
4 PIN (output)
EtherCAT (-EH)
(driver side)
LINEARIZATION RAMPS
12 PIN - OPTION /Z
5 PIN
Serial (-PS)
(driver side)
(driver side)
Note: for the electronic connections of 7 or 12 pin main connector, see section 12.1
14 MODEL CODES OF POWER SUPPLY AND COMMUNICATION CONNECTORS (to be ordered separately)
15 SOFTWARE TOOLS
The driver configuration and parameters can be easily set with the Atos E-SW programming software, available in four different versions according to the
driver’s communication execution: E-SW-PS (Serial), E-SW-BC (CANopen), E-SW-BP (PROFIBUS DP), E-SW-EH (EtherCAT). Programming software
E-SW-BC, E-SW-BP, E-SW-EH for BC, BP and -EH drivers, can be also used to modify the valve’s parameterization through the serial communication inter-
face, without disconnecting the valve from the machine’s bus line.
For a more detailed description of software interface, PC requirements, adapters, cables and terminators, please refer to technical table G500.
Programming software, must be ordered separately:
E-SW-* (mandatory - first supply) = Dvd including E-SW-* software installer and operator manuals; it allows the registration to Atos digital service
E-SW-*-N (optional - next supplies) = as above but not allowing the registration to Atos digital service
On first supply of the E-SW-* software, it is required to apply for the registration in the Atos download area: www.download.atos.com.
Once the registration is completed, the password will be sent by email.
The software remains active for 10 days from the installation date and then it stops until the user inputs his password.
With the password you can also download, in your personal area, the latest releases of the Atos software, manuals, drivers and configuration files.
F065
16 INSTALLATION DIMENSIONS [mm]
ZH-7P or ZM-7P
RZMO-AE
RZMO-AES-* (dotted line)
Mass: 4 Kg
ZH-7P or ZM-7P
RZMO-AES-EH*
Mass: 4,1 Kg
666
ISO 4401: 2000
Mounting surface: 4401-03-02-0-05
(see table P005) HZMO-A
Fastening bolts:
4 socket head screws M5 bolts class 12.9
Tightening torque = 8 Nm Mass: 2,8 Kg
Seals: 4 OR 108
12/13