Technical Data

ANTIFOULING SEAQUANTUM PLUS

Product description
Antifouling SeaQuantum Plus is a tin-free high performance self-polishing antifouling, based on a
hydrolysing organosilyl polymer as binder. This binder dissolves in seawater at a rate permitting the
continuous exposure of fresh antifouling.
IMO Anti-fouling System Convention compliant (AFS/CONF/26).

Recommended use
As an antifouling for newbuildings and major refurbishment, for side and flatbottom areas on vessels
operating at medium/high speed with drydocking intervals up to 60 months.

Film thickness and spreading rate


Minimum Maximum
Film thickness, dry (µm) 75 150
Film thickness, wet (µm) 160 320
Theoretical spreading rate 6,2 3,1
(m²/l)

Physical properties
Colour Dark Red, Light Red
Solids (vol %)* 47 ± 2

Flash point 26±2 (Setaflash)

*Measured according to ISO 3233:1998 (E)

Surface preparation
Coated surfaces
To be applied on a clean, dry approved primer/undercoat or intact self-polishing antifouling in
accordance with Jotun's requirements. Remove surface contamination by high pressure fresh water
cleaning.

Other surfaces
The coating may be used on other substrates. Please contact your local Jotun office for more
information.

Condition during application


The temperature of the substrate should be minimum 3ºC above the dew point of the air,
temperature and relative humidity measured in the vicinity of the substrate. Good ventilation is
usually required in confined areas to ensure correct drying.

ANTIFOULING SEAQUANTUM PLUS Page 1 of 3


Application methods
Spray Use airless spray
Brush May be used but care must be taken to achieve the specified dry film thickness.
Roller May be used. However when using roller application care must be taken to apply
sufficient material in order to achieve the specified dry film thickness.

Application data
Mixing ratio (volume) Single pack.

Thinner/Cleaner Jotun Thinner No. 7


Guiding data airless spray
Pressure at nozzle 15 MPa (150 kp/cm², 2100 psi.).
Nozzle tip 0.53 - 0.78 mm (0.021 - 0.031").
Spray angle 65 - 80°
Filter Check to ensure that filters are clean.

Drying time
Drying times are generally related to air circulation, temperature, film thickness and number of coats,
and will be affected correspondingly. The figures given in the table are typical with:
* Good ventilation (Outdoor exposure or free circulation of air)
* Typical film thickness
* One coat on top of inert substrate

Substrate temperature 5°C 10°C 23°C 40°C


Surface dry 60 min 45 min 30 min 15 min
Through dry 8h 6h 4h 3h
Dry for launching 1 12-24 h 10-22 h 8-20 h 8-16 h
Dry to recoat, minimum 2 12 h 9h 7h 6h

1. Indicate the time which normally occurs in a drydocking situation where the drying time depends
on the total film thickness of primer/antifouling applied. The drying time will increase with
increasing film thickness.
2. The surface should be dry and free from any contamination prior to application of the subsequent
coat.

The given data must be considered as guidelines only. The actual drying time/times before recoating
may be shorter or longer, depending on film thickness, ventilation, humidity, underlying paint system,
requirement for early handling and mechanical strength etc. A complete system can be described on
a system sheet, where all parameters and special conditions could be included.

Recommended type of primer:


Anticorrosive primer system suitable for purpose with
Safeguard Universal ES or Vinyguard Silvergrey 88 as sealer coat/tie-coat.

Other systems may be specified, depending on area of use

Storage
The product must be stored in accordance with national regulations. Storage conditions are to keep
the containers in a dry, cool, well ventilated space and away from source of heat and ignition.
Containers must be kept tightly closed.

ANTIFOULING SEAQUANTUM PLUS Page 2 of 3


Handling
Handle with care. Stir well before use.

Packing size
20 litre container.

Packing may vary from country to country according to local requirements.

Health and safety


Please observe the precautionary notices displayed on the container. Use under well ventilated
conditions. Do not breathe or inhale mist. Avoid skin contact. Spillage on the skin should immediately
be removed with suitable cleanser, soap and water. Eyes should be well flushed with water and
medical attention sought immediately.

For detailed information on the health and safety hazards and precautions for use of this
product, we refer to the Material Safety Data Sheet.

DISCLAIMER
The information in this data sheet is given to the best of our knowledge based on laboratory testing and
practical experience. However, as the product is often used under conditions beyond our control, we
cannot guarantee anything but the quality of the product itself. We reserve the right to change the given
data without notice.

Head Office & Nordic Europe Middle East South East A s i a


Jotun P aints Jotun P aints (Europe) Ltd. Jotun U .A .E Ltd. LLC . Jotun (Singapore) P te. Ltd.
P .O . Box 2021 Stather Road, Flixborough No 11-15, Sixth Lok Y ang

N-3248 Sandefjord North Lincolnshire DN15 A l Q uoz Industrial A rea Road

Norway 8RR P .O Box 3671 Jurong


U nited Kingdom Dubai U .A .E Singapore 628 111
P hone +47 33 45 70 00
Fax +47 33 46 46 13 P hone +44 172 44 00 000 P hone +65 6265 4711
Fax +44 172 44 00 100 P hone +971 4 3 39 50 00 Fax +65 6265 7484
Fax +971 4 3 38 06 66

Jotun is a World Wide company with factories, sales offices and stocks in more than 50 countries. For your
nearest local Jotun address please contact the nearest regional office or visit our website at www.jotun.com

ISSUED 4 JUNE 2004 BY JOTUN PAINTS


THIS DATA SHEET SUPERSEDES THOSE PREVIOUSLY ISSUED

ANTIFOULING SEAQUANTUM PLUS Page 3 of 3