A110WZ1 COMPRESSOR

T E C H N I C AL S PE CI FI C A T I O N

HUANGSHI DONPER COMPRESSOR CO., LTD.


2021.03
A110WZ1 COMPRESSOR TECHNICAL SPECIFICATION

INDEX
page
1、Compressor Type………………………………………..2
2、Performance Data……………………………………….2
3、Running Condition………………………………………2
4、Compressor Mechanical Information……………………3
5、Compressor Shape……………………………………….3
6、Wiring Diagram…………………………………………4
7、Fixing of mounting bracket and cabinet base………….4
8、Starting relay and overload protector……………………4
9、Capacitor………………………………………….6
10、Delivery State………………………………………….6
11、Package、Storage and Transportation…………………7
12、Technical Items…………………………………..……7

Page 1 of 8
A110WZ1 COMPRESSOR TECHNICAL SPECIFICATION

1. Compressor Type
Compressor model A110WZ1
Rated voltage/frequency 220-240V~50Hz
Refrigerant R134a
Application Low back pressure(LBP)
Cooling method Static Cooling
Start torque Low starting torque(LST)
Control device Capillary tube
Motor type RSCR
Running capacitor 6μF
Starting capacitor /

2. Performance Data
Cooling Capacity(≥95%) COP(≥95%)
Displacem

Net Wt.

Charge
Oil
ent

ASHRAE CECOMAF ASHRAE CECOMAF

-35 -30 -25 -23.3 -20 -15 -10 -25 -23.3 -25
cm3 kg ml w w w w w w w w w/w w/w
4.3 5.4±0.4 140±10 63 78 99 110 122 141 162 95 1.27 1.09
Note: These datas come from the test with a PTC relay

Testing condition:
LBP
Test conditions
ASHRAE CECOMAF
Evaporating Temp. -23.3℃ -25℃
Ambient Temp. +32.2℃ +32℃
Condensing Temp. +54.4℃ +55℃
Suction Temp. +32.2℃ +32℃
Subcooling Temp. +32.2℃ +55℃

3. Running Condition
Ambient temp. 0~43℃
Evaporating temp. -35~-15℃
Voltage range 187~254V
Max. condensing temp. 65℃
Max. winding temp. 130℃
Max. shell temp. 95℃
Max. discharge temp. 120℃
Start voltage 187V [0.3/0.3MPa(abs)]

Page 2 of 8
A110WZ1 COMPRESSOR TECHNICAL SPECIFICATION

Shell min. resistance to pressure 35bar

4. Compressor Mechanical Information


Oil type Ester oil
Viscosity 18.2-23.1mm2/s
Oil charged 140±10ml
Diameter of suction tube (I.D.) Φ6.2±0.1mm
Diameter of discharge tube(I.D.) Φ4.95±0.1mm
Diameter of process tube (I.D.) Φ6.2±0.1mm
Material of suction tube, process tube and
Copper tube
discharge tube
Compressor noise 43dB(A)
Vibration 0.9m/s2
Protecting gas Dry com.air(Dew point-60℃)

5. Compressor Shape

Caution:Suction tube and process tube can be exchanged


Unmarked tolerance:±5mm
Unmarked Angle: ±10°

Page 3 of 8
A110WZ1 COMPRESSOR TECHNICAL SPECIFICATION

6. Wiring Diagram

Note: Each of the starting relay、the overload protector、the cover and the capacitor are
separately provided by our company.

7. Fixing of mounting bracket and cabinet base

1、Hexagon nut
2、Spring washer
3、Flat washer
4、Compressor mounting bracket
5、Rubber grommet
6、Sleeve
7、Cabinet base
8、Screw

Note: Equipment assembly is all provided by our company. Above is just for reference,
details can refer to delivery state.

8. Starting relay and overload protector


8.1 Starting relay
Model QP2-15C
Hangzhou Star shuaier Shunde Ronggui Electronic Circuit
Supplier
Electric Appliance Co.,Ltd. Measuring Equipment Co. Ltd.
Resistance Ω 15±20%
Run time S 0.2~1.5
Rese ttime S ≤100
Max working voltage V 350
Max current A 8
Assembly force≤80N Disassembly force≥12.5N
Flammability: Anti-flammability

Page 4 of 8
A110WZ1 COMPRESSOR TECHNICAL SPECIFICATION

8.2 Overload protector


Model DRB18N61A2 TB45-120
Hangzhou Star shuaier Shunde Ronggui Electronic Circuit
Supplier
Electric Appliance Co.,Ltd. Measuring Equipment Co. Ltd.
Max.T.C Amp.(25℃) A 4.5
Trip time S 5~15
Reset time S 30~150
Open temp. ±5℃ 120
Close temp. ±9℃ 61
Assembly force≤80N Disassembly force≥12.5N
Flammability: Anti-flammability
QP2-15C DRB18N61A2 TB45-120

8.3 Combo starting relay and overload protector


Model ZHB45-120P15 QP2-15C ZH+TB45-120
Changshu Tianyin Shunde Ronggui Electronic
Supplier Electromechanical Circuit Measuring
Co.,Ltd. Equipment Co. Ltd.
Resistance Ω 15±20%
Run time S 0.2~1.5
Starting
Reset time S ≤100
relay
Max working voltage V 350
Max current A 8
Max.T.C Amp.(25℃) A 4.5
Trip time S 5~15
Protector Reset time S 30~180
Open temp. ±5℃ 120
Close temp. ±9℃ 61
ZHB45-120P15 QP2-15C ZH+TB45-120

Page 5 of 8
A110WZ1 COMPRESSOR TECHNICAL SPECIFICATION

9. Capacitor
Model μF 6
Rated voltage V.AC 450
Shanghai Haoyue Electronics CO.,LTD CBB65D(MKP-1)
Supplier and model Ningguo Yuhua Electrical Product CO.,LTD CBB65
Anhui Tongfeng Electronics CO.,LTD CBB65A-2
Anhui Feida Electrical Technology CO.,LTD CBB65

10. Delivery State


No. Name Model Quantity CODE
1 Compressor A110WZ1 1pcs
2 Φ6.4 1pcs
Rubber plug
3 Φ8.2 2pcs
4 Rubber grommet QET-03U 4pcs
Hangzhou Star shuaier Electric
QP2-15C
Appliance Co.,Ltd.
5 Starting relay 1pcs
Shunde Ronggui Electronic Circuit
QP2-15C
Measuring Equipment Co. Ltd.
Hangzhou Star shuaier Electric
DRB18N61A2
Appliance Co.,Ltd.
6 Overload protector 1pcs
Shunde Ronggui Electronic Circuit
TB45-120
Measuring Equipment Co. Ltd.
Changshu Tianyin
ZHB45-120P15
Starting relay and Electromechanical Co. Ltd.
7 1pcs
Overload protector QP2-15C ZH Shunde Ronggui Electronic Circuit
+TB45-120 Measuring Equipment Co. Ltd.
8 Capacitor 6μF 1pcs
9 Relaying cover A1 1pcs
10 Sleeve QET-04 4pcs
11 Anchor bolt assembly QET-44 4pcs
12 Nut QET-27 4pcs
Notes:1.All electrical parts and equipment assembly are supplied separately, not installed
on the compressor.
2.All electrical parts and equipment assembly according to “Delivery state”are all
provided by our company.

Page 6 of 8
A110WZ1 COMPRESSOR TECHNICAL SPECIFICATION

11. Package、Storage and Transportation


Package type unrecyclable
Quantity 100pcs/box
Transportation By sea
Storage Max. 2 layers
Cross Weight Kg 575±40
Net Weight Kg 540±40
3
Volume m 1.09
Dimension: length×width×height (cm) 112×89×100
Wooden supporter、upper wooden cover、
Main components foam divider、plastic sheet、cardboard
cover、rain-proof cover、wrapping
Keep the compressor in normal or
Movement
vertical position
No allowable compressor’s damage and
Trans. test requirement
performance loss.

12 . Technical Items
(1)、Don’t take off the rubber plugs before using and installing compressor to prevent dust
and moisture.
(2) 、 Don’t turn down or incline the compressor during storage, transportation or
installation and avoid vibration and shock.
(3)、The compressor must be kept horizontally during running, the inclination angle must
be less than 5°.
(4)、A special polyester oil is charged in the R134a compressor and the charging volume
has been optimized by DONPER. Don’t pour out or add any refrigerant oil.
(5)、The interval of compressor operation must be more than 4 minutes in order to obtain a
pressure balance in the systems.
(6)、Don’t start or run in the case of vacuum or charge high voltage in the compressor. The
compressor cannot be used to vacuumize the refrigeration system.
(7)、The design of refrigeration system must be suitable to insure the oil could flow back to
compressor.
(8)、The maximum ambient temperature of the compressor operation is 43℃.When
continuously operating under the maximum ambient temperature 43℃,the condensing
pressure and the peak pressure should not exceed as showing in the following table.
Refrigerant R134a
Max. condensing pressure 1.59MPa
Peak 2.0MPa
(9)、Widen the evaporating Temp. range of the compressor should be approved by
DONPER.
Page 7 of 8
A110WZ1 COMPRESSOR TECHNICAL SPECIFICATION

(10)、Compressor should be stored in a dry place.


(11)、Compressor accessories (eg: starting relay, overload protector etc.) are put in the
accessories box instead of fixing on the compressor.
(12)、The stocking period must be less than 6 months after the date of production. If longer,
you have to check whether the filled gas is sufficient. Replenishment must be done if
necessary.
(13)、It’s necessary to keep the compressor without rubber plug as short time as possible
(max time 10 min).
(14)、R134a systems require a filter with drying agent which suitable for R134a refrigerant
(15)、The vacuum pump and the charging system must only be dedicated to R134a.
(16)、The refrigeration system should minimize the content of chlorine and moisture, and
must be free of paraffin and silicon oil.
(17) 、 The organic substance non-compatible with R134a cannot be used in the
refrigeration system.

Page 8 of 8