351701digsf0053 Exco00 30
351701digsf0053 Exco00 30
351701digsf0053 Exco00 30
Sheet of Sheets
Company Document ID 351701DIGSF0053 2/30
Validity Revision
Contractor Document ID 24640401MIIBF0053 Status Number
Vendor Document ID 50001000A0IDS303EN EX-CO 00
Datasheets of supplied intruments and related accessories describing their technical features
Document Verification
Preparedby Signature Date
F.BALLERINI 31/05/2018
Vendor
by Signature Date
Company
Sheet of Sheets
Company Document ID 351701DIGSF0053 3/30
Validity Revision
Contractor Document ID 24640401MIIBF0053 Status Number
Vendor Document ID 50001000A0IDS303EN EX-CO 00
REVISION LIST
EX-DE 00 ISSUED FOR COMMENTS
EX-DE 01 ISSUED FOR COMMENTS
EX-DE 02 ISSUED FOR COMMENTS
EX-CO 00 ISSUED APPROVED FOR CONSTRUCTION
HOLD RECORD
ASSUMPTION RECORD
Sheet of Sheets
Company Document ID 351701DIGSF0053 4/30
Validity Revision
Contractor Document ID 24640401MIIBF0053 Status Number
Vendor Document ID 50001000A0IDS303EN EX-CO 00
TABLE OF CONTENTS
SHEET 1 COVER
SHEET 2 DOCUMENT VERIFICATION
SHEET 3 REVISION LIST
SHEET 4 TABLE OF CONTENTS
SHEET 5
SECTION 1:
INSTRUMENTATION INCLUDED IN THE HIGH PRESSURE GAS LINE AND WATER BATH HEATER
SHEET 21 SECTION 2:
INSTRUMENTATION INCLUDED IN THE FUEL GAS LINE AND BURNER PACKAGE
SHEET 22 PRESSURE GAUGE DATA SHEET
SHEET 23 PRESSURE SWITCH DATA SHEET
SHEET 24 DIFFERENTIAL PRESSURE SWITCH DATA SHEET
SHEET 25 FLANGED DBB MANIFOLD DATA SHEET
SHEET 26 THREADED DBB 3V MANIFOLD DATA SHEET
SHEET 27 THREADED 5V MANIFOLD - 6 WAYS DATA SHEET
SHEET 28 SOLENOID VALVES DATA SHEET
SHEET 29 BLOWER TEMPERATURE TRANSMITTER DATA SHEET
SHEET 30 BLOWER VIBRATION TRANSMITTER DATA SHEET
Sheet of Sheets
Company Document ID 351701DIGSF0053 5/30
Contractor Document ID 24640401MIIBF0053 Validity Status Revision Number
SECTION 1:
INSTRUMENTATION INCLUDED IN THE HIGH
PRESSURE GAS LINE AND WATER BATH HEATER
Document classified as: 2 - Company Confidential #
Sheet of Sheets
Company Document ID 351701DIGSF0053 6/30
Contractor Document ID 24640401MIIBF0053 Validity Status Revision Number
TEMPERATURE TRANSMITTER
DATA SHEET
PROJECT REF.: REV. DATE DESCRIPTION BY CHK'D APPR.
TAKORADI-TEMA INTERCONNECTION
A 10/11/2017 FIRST ISSUE F.B. D.R. A.S.
PROJECT (TTIP)
DOCUMENT TITLE : B 19/12/2017 FIRST REVISION F.B. D.R. A.S.
INSTRUMENTS SPECIFICATIONS AND
C 16/02/2018 SECOND REVISION F.B. D.R. A.S.
DATASHEETS
LOCATION : D 31/05/2018 APPROVED FOR CONSTRUCTION F.B. D.R. A.S.
GHANA
1. Tag No. See below Service: Water
2. Function Record Indicate Control Blind Trans
Other horizontal mounting with LDC display
3. Case MFR STD Nom. Size Color: MFR STD Other
4. Mounting Flush Surface Yoke Other
5. Enclosure Class General Purpose Weather Proof Expl. Proof Ex-d Class A (IEC 60751)
For Use In Intrin. Safe System Other Ex-d IIB T4 - min. IP65 - TROPICALIZED (1)
GENERAL
6. Power Supply 110V 60Hz 220V 50Hz 24Vdc Other LOOP POWERED
7. Chart Strip Roll Fold Circular Time Marks
Range Number
8. Chart Drive Speed Power
9. Scales Type
Range 1 2 3 4
10. Transmitter 4÷20 mA 10÷50 mA 3÷15 psig Other Smart type (Hart Protocol)
XMTR
Output For Receiver See Spec. Sheet
11. Control Modes P = Prop (Gain), I = Integral (AutoReset), D = Derivate (Rate)
Sub: s = Slow f = Fast
P PI PD PID If Df Is Ds
Other
CONTROLLER 12. Action On meas. Increase output: Increases Decreases
13. Auto-Man Switch None MFR STD Other
14. Set Point Adj. Manual External Remote Other
15. Manual Reg. None MFR STD Other
16. Output 4÷20 mA 10÷50 mA 3÷15 psig Other
17. Fill SAMA Class Compensation
18. Process Data Temp: Normal Max Max Press.
19. Range Fixed Adj. Range Set at
Overrange protection to
20. Bulb Type Mtl. Extension: Lenght Type
ELEMENT
Size: Diameter Lenght Insertion
Conn: Lenght m Above Below Instr.
21. Capillary MFR STD Lenght Mtl. Armor
22. Well Mtl. SS 316 Insertion 450mm Lag Ext. VENDOR STD Conn 2"ANSI 150 RF
Constr: Drilled Built-Up Other TAPERED - 1/2" NPT INSTRUM
23. Alarm Switches Quantity Form Rating
24. Function Temp Deviation Contacts to On Temp Increase
25. Options Filter Reg Supply Gage Output Gage Charts
OPTIONS Other Pt100 3 wire, double element (class A - IEC 60751) , LCD DISPLAY WITH
ENGINEERING UNITS. ELECTRICAL CONNECTION 1/2"NPT-F
26. MFR & Model No. TBD
DESCRIPTION Nozzle
Operat. Design. Operat. Design.
Inside Span set MANUFACT.
TAG Press. Press. Temp. Temp. P.F. CODE
Diameter (°C) Model
(barg) (barg) (°C) (°C)
(mm)
TIT/TW-23-202-ON WBH BATH TEMPERATURE ATM F.V./0,69 0÷+86 +100 49 0÷+100 PFR50001000S501 ABB TSP331
TIT/TW-23-211-ON WBH BATH TEMPERATURE ATM F.V./0,69 0÷+86 +100 49 0÷+100 PFR50001000S501 ABB TSP331
TIT/TW-23-212-ON WBH BATH TEMPERATURE ATM F.V./0,69 0÷+86 +100 49 0÷+100 PFR50001000S501 ABB TSP331
TIT/TW-23-221-ON WBH BATH TEMPERATURE ATM F.V./0,69 0÷+86 +100 49 0÷+100 PFR50001000S501 ABB TSP331
TIT/TW-23-222-ON WBH BATH TEMPERATURE ATM F.V./0,69 0÷+86 +100 49 0÷+100 PFR50001000S501 ABB TSP331
TIT/TW-23-231-ON WBH BATH TEMPERATURE ATM F.V./0,69 0÷+86 +100 49 0÷+100 PFR50001000S501 ABB TSP331
NOTES:
(1) EQUIMPENT SHALL BE TROPICALIZED IN COMPLIANCE WITH THE ATTACHED ENI SPEC. 05497.VAR.ELE.STD_05 FOR HOT WET TROPICAL CLIMATE
(2) STANDARD MANUFACTURER PAINTING COMPATIBLE WITH MARINE C5I ENVIRONMENT (ISO 12944)
(3) IEC-EX CERTIFICATE REQUIRED
(4) EQUIMPENT SHALL BE TESTED IN COMPLIANCE WITH ATTACHED INSPECTION DATASHEET 351700BMGB30200 (pages 10 to 13)
(5) C/W EN10204 3.1 CERTIFICATE OF MATERIALS FOR THERMOWELL
(6) C/W CERTIFICATE OF CALIBRATION
(7) C/W SIL CERTIFICATE
(8) C/W TAG PLATE IN SS WITH ENGRAVED TAG NUMBER
Document classified as: 2 - Company Confidential #
Sheet of Sheets
Company Document ID 351701DIGSF0053 7/30
Contractor Document ID 24640401MIIBF0053 Validity Status Revision Number
TEMPERATURE TRANSMITTER
DATA SHEET
PROJECT REF.: REV. DATE DESCRIPTION BY CHK'D APPR.
TAKORADI-TEMA INTERCONNECTION
A 10/11/2017 FIRST ISSUE F.B. D.R. A.S.
PROJECT (TTIP)
DOCUMENT TITLE : B 19/12/2017 FIRST REVISION F.B. D.R. A.S.
INSTRUMENTS SPECIFICATIONS AND
C 16/02/2018 SECOND REVISION F.B. D.R. A.S.
DATASHEETS
LOCATION : D 31/05/2018 APPROVED FOR CONSTRUCTION F.B. D.R. A.S.
GHANA
1. Tag No. See below Service: Exhaust on WBH stack tip
2. Function Record Indicate Control Blind Trans
Other horizontal mounting
3. Case MFR STD Nom. Size Color: MFR STD Other
4. Mounting Flush Surface Yoke Other
5. Enclosure Class General Purpose Weather Proof Expl. Proof Ex-d Class A (IEC 60751)
For Use In Intrin. Safe System Other Ex-d IIB T4 - min. IP65 - TROPICALIZED (1)
GENERAL
6. Power Supply 110V 60Hz 220V 50Hz 24Vdc Other LOOP POWERED
7. Chart Strip Roll Fold Circular Time Marks
Range Number
8. Chart Drive Speed Power
9. Scales Type
Range 1 2 3 4
10. Transmitter 4÷20 mA 10÷50 mA 3÷15 psig Other Smart type (Hart Protocol)
XMTR
Output For Receiver See Spec. Sheet
11. Control Modes P = Prop (Gain), I = Integral (AutoReset), D = Derivate (Rate)
Sub: s = Slow f = Fast
P PI PD PID If Df Is Ds
Other
CONTROLLER 12. Action On meas. Increase output: Increases Decreases
13. Auto-Man Switch None MFR STD Other
14. Set Point Adj. Manual External Remote Other
15. Manual Reg. None MFR STD Other
16. Output 4÷20 mA 10÷50 mA 3÷15 psig Other
17. Fill SAMA Class Compensation
18. Process Data Temp: Normal Max Max Press.
19. Range Fixed Adj. Range Set at
Overrange protection to
20. Bulb Type Mtl. Extension: Lenght Type
ELEMENT
Size: Diameter Lenght Insertion
Conn: Lenght m Above Below Instr.
21. Capillary MFR STD Lenght Mtl. Armor
22. Well Mtl. SS 316 Insertion 500 mm Lag Ext. VENDOR STD Conn 2"ANSI 150 RF
Constr: Drilled Built-Up Other TAPERED - 1/2" NPT INSTRUM
23. Alarm Switches Quantity Form Rating
24. Function Temp Deviation Contacts to On Temp Increase
25. Options Filter Reg Supply Gage Output Gage Charts
OPTIONS Other Pt100 3 wire, double element (class A - IEC 60751)
ELECTRICAL CONNECTION 1/2"NPT-F, SIL 2 LEVEL CERTIFIED
26. MFR & Model No. ABB TTH200.Y0.H.BF.CS
DESCRIPTION Nozzle
Operat. Design. Operat. Design.
Inside Span set MANUFACT.
TAG Press. Press. Temp. Temp. P.F. CODE
Diameter (°C) Model
(barg) (barg) (°C) (°C)
(mm)
TT/TW-23-204-ON WBH FY2301A STACK TIP ATM ATM 0÷+265 +350 49 0÷+400 PFR50001000S502 ABB TTH200
TT/TW-23-244-ON WBH FY2301B STACK TIP ATM ATM 0÷+265 +350 49 0÷+400 PFR50001000S502 ABB TTH200
TT/TW-23-254-ON WBH FY2301C STACK TIP ATM ATM 0÷+265 +350 49 0÷+400 PFR50001000S502 ABB TTH200
NOTES:
(1) EQUIMPENT SHALL BE TROPICALIZED IN COMPLIANCE WITH THE ATTACHED ENI SPEC. 05497.VAR.ELE.STD_05 FOR HOT WET TROPICAL CLIMATE
(2) STANDARD MANUFACTURER PAINTING COMPATIBLE WITH MARINE C5I ENVIRONMENT (ISO 12944)
(3) IEC-EX & CERTIFICATE REQUIRED
(4) EQUIMPENT SHALL BE TESTED IN COMPLIANCE WITH ATTACHED INSPECTION DATASHEET 351700BMGB30200 (pages 10 to 13)
(5) C/W EN10204 3.1 CERTIFICATE OF MATERIALS FOR THERMOWELL
(6) C/W CERTIFICATE OF CALIBRATION
(7) C/W SIL CERTIFICATE
(8) C/W TAG PLATE IN SS WITH ENGRAVED TAG NUMBER
Document classified as: 2 - Company Confidential #
Sheet of Sheets
Company Document ID 351701DIGSF0053 8/30
Contractor Document ID 24640401MIIBF0053 Validity Status Revision Number
TEMPERATURE TRANSMITTER
DATA SHEET
PROJECT REF.: REV. DATE DESCRIPTION BY CHK'D APPR.
TAKORADI-TEMA INTERCONNECTION
A 10/11/2017 FIRST ISSUE F.B. D.R. A.S.
PROJECT (TTIP)
DOCUMENT TITLE : B 19/12/2017 FIRST REVISION F.B. D.R. A.S.
INSTRUMENTS SPECIFICATIONS AND
C 16/02/2018 SECOND REVISION F.B. D.R. A.S.
DATASHEETS
LOCATION : D 31/05/2018 APPROVED FOR CONSTRUCTION F.B. D.R. A.S.
GHANA
1. Tag No. See below Service: Natural Gas - ESD
2. Function Record Indicate Control Blind Trans
Other With LCD Display
3. Case MFR STD Nom. Size Color: MFR STD Other
4. Mounting Flush Surface Yoke Other
5. Enclosure Class General Purpose Weather Proof Expl. Proof Ex-d Class A (IEC 60751)
For Use In Intrin. Safe System Other Ex-d IIB T4 - min. IP65 - TROPICALIZED (1)
GENERAL
6. Power Supply 110V 60Hz 220V 50Hz 24Vdc Other LOOP POWERED
7. Chart Strip Roll Fold Circular Time Marks
Range Number
8. Chart Drive Speed Power
9. Scales Type
Range 1 2 3 4
10. Transmitter 4÷20 mA 10÷50 mA 3÷15 psig Other Smart type (Hart Protocol)
XMTR
Output For Receiver See Spec. Sheet
11. Control Modes P = Prop (Gain), I = Integral (AutoReset), D = Derivate (Rate)
Sub: s = Slow f = Fast
P PI PD PID If Df Is Ds
Other
CONTROLLER 12. Action On meas. Increase output: Increases Decreases
13. Auto-Man Switch None MFR STD Other
14. Set Point Adj. Manual External Remote Other
15. Manual Reg. None MFR STD Other
16. Output 4÷20 mA 10÷50 mA 3÷15 psig Other
17. Fill SAMA Class Compensation
18. Process Data Temp: Normal Max Max Press.
19. Range Fixed Adj. Range Set at
Overrange protection to
20. Bulb Type Mtl. Extension: Lenght Type
ELEMENT
Size: Diameter Lenght Insertion
Conn: Lenght m Above Below Instr.
21. Capillary MFR STD Lenght Mtl. Armor
22. Well Mtl. SS 316 Insertion 300 mm (8) Lag Ext. VENDOR STD Conn 2"ANSI 900 RF
Constr: Drilled Built-Up Other TAPERED - 1/2" NPT INSTRUM
23. Alarm Switches Quantity Form Rating
24. Function Temp Deviation Contacts to On Temp Increase
25. Options Filter Reg Supply Gage Output Gage Charts
OPTIONS Other Pt100 3 wire, double element (class A - IEC 60751) , LCD DISPLAY WITH
ENGINEERING UNITS. ELECTRICAL CONNECTION 1/2"NPT-F, SIL 2 LEVEL CERTIFIED
26. MFR & Model No. ABB TTF300.H5.C.2.H.BF-CS
DESCRIPTION Nozzle
Operat. Design. Operat. Design.
Inside Span set MANUFACT.
TAG Press. Press. Temp. Temp. P.F. CODE
Diameter (°C) Model
(barg) (barg) (°C) (°C)
(mm)
TIT/TW-23-206-ON OUTLET GAS TEMP. (ESD) 66 138 0 ÷ +40 -29 ÷+100 49 0 ÷ +100 PFR50001000S510 ABB TTF300
TIT/TW-23-216-ON OUTLET GAS TEMP. (ESD) 66 138 0 ÷ +40 -29 ÷+100 49 0 ÷ +100 PFR50001000S510 ABB TTF300
TIT/TW-23-226-ON OUTLET GAS TEMP. (ESD) 66 138 0 ÷ +40 -29 ÷+100 49 0 ÷ +100 PFR50001000S510 ABB TTF300
NOTES:
(1) EQUIMPENT SHALL BE TROPICALIZED IN COMPLIANCE WITH THE ATTACHED ENI SPEC. 05497.VAR.ELE.STD_05 FOR HOT WET TROPICAL CLIMATE
(2) STANDARD MANUFACTURER PAINTING COMPATIBLE WITH MARINE C5I ENVIRONMENT (ISO 12944)
(3) IEC-EX & CERTIFICATE REQUIRED
(4) EQUIMPENT SHALL BE TESTED IN COMPLIANCE WITH ATTACHED INSPECTION DATASHEET 351700BMGB30200 (pages 10 to 13)
(5) C/W EN10204 3.1 CERTIFICATE OF MATERIALS FOR THERMOWELL
(6) C/W CERTIFICATE OF CALIBRATION
(7) C/W SIL CERTIFICATE
(8) THERMOWELL CALCULATION SHEET REQUIRED, ACC. TO ASME PTC 19.3 TW-2016 @ T=30 °C, P=26,5 barg, velocity=27 m/s, medium density=22,5 kg/m³
(9) C/W TAG PLATE IN SS WITH ENGRAVED TAG NUMBER
Document classified as: 2 - Company Confidential #
Sheet of Sheets
Company Document ID 351701DIGSF0053 9/30
Contractor Document ID 24640401MIIBF0053 Validity Status Revision Number
TEMPERATURE TRANSMITTER
DATA SHEET
PROJECT REF.: REV. DATE DESCRIPTION BY CHK'D APPR.
TAKORADI-TEMA INTERCONNECTION
A 10/11/2017 FIRST ISSUE F.B. D.R. A.S.
PROJECT (TTIP)
DOCUMENT TITLE : B 19/12/2017 FIRST REVISION F.B. D.R. A.S.
INSTRUMENTS SPECIFICATIONS AND
C 16/02/2018 SECOND REVISION F.B. D.R. A.S.
DATASHEETS
LOCATION : D 31/05/2018 APPROVED FOR CONSTRUCTION F.B. D.R. A.S.
GHANA
1. Tag No. See below Service: Natural Gas - UCP
2. Function Record Indicate Control Blind Trans
Other with LCD display
3. Case MFR STD Nom. Size Color: MFR STD Other
4. Mounting Flush Surface Yoke Other
5. Enclosure Class General Purpose Weather Proof Expl. Proof Ex-d Class A (IEC 60751)
For Use In Intrin. Safe System Other Ex-d IIB T4 - min. IP65 - TROPICALIZED (1)
GENERAL
6. Power Supply 110V 60Hz 220V 50Hz 24Vdc Other LOOP POWERED
7. Chart Strip Roll Fold Circular Time Marks
Range Number
8. Chart Drive Speed Power
9. Scales Type
Range 1 2 3 4
10. Transmitter 4÷20 mA 10÷50 mA 3÷15 psig Other Smart type (Hart Protocol)
XMTR
Output For Receiver See Spec. Sheet
11. Control Modes P = Prop (Gain), I = Integral (AutoReset), D = Derivate (Rate)
Sub: s = Slow f = Fast
P PI PD PID If Df Is Ds
Other
CONTROLLER 12. Action On meas. Increase output: Increases Decreases
13. Auto-Man Switch None MFR STD Other
14. Set Point Adj. Manual External Remote Other
15. Manual Reg. None MFR STD Other
16. Output 4÷20 mA 10÷50 mA 3÷15 psig Other
17. Fill SAMA Class Compensation
18. Process Data Temp: Normal Max Max Press.
19. Range Fixed Adj. Range Set at
Overrange protection to
20. Bulb Type Mtl. Extension: Lenght Type
ELEMENT
Size: Diameter Lenght Insertion
Conn: Lenght m Above Below Instr.
21. Capillary MFR STD Lenght Mtl. Armor
22. Well Mtl. SS 316 Insertion 300 mm (8) Lag Ext. VENDOR STD Conn 2"ANSI 900 RF
Constr: Drilled Built-Up Other TAPERED - 1/2" NPT INSTRUM
23. Alarm Switches Quantity Form Rating
24. Function Temp Deviation Contacts to On Temp Increase
25. Options Filter Reg Supply Gage Output Gage Charts
OPTIONS Other Pt100 3 wire, double element (class A - IEC 60751) , LCD DISPLAY WITH
ENGINEERING UNITS. ELECTRICAL CONNECTION 1/2"NPT-F, SIL 2 LEVEL CERTIFIED
26. MFR & Model No. ABB TTF300.H5.C.2.H.BF-CS
Nozzle
Operat. Design. Operat. Design.
Inside Span set MANUFACT.
TAG DESCRIPTION Press. Press. Temp. Temp. P.F. CODE
Diameter (°C) Model
(barg) (barg) (°C) (°C)
(mm)
TIT/TW-23-207-ON OUTLET GAS TEMP. (UCP) 66 138 0 ÷ +40 -29 ÷+100 49 0 ÷ +100 PFR50001000S510 ABB TTF300
TIT/TW-23-217-ON OUTLET GAS TEMP. (UCP) 66 138 0 ÷ +40 -29 ÷+100 49 0 ÷ +100 PFR50001000S510 ABB TTF300
TIT/TW-23-227-ON OUTLET GAS TEMP. (UCP) 66 138 0 ÷ +40 -29 ÷+100 49 0 ÷ +100 PFR50001000S510 ABB TTF300
TW-23-232-ON INLET GAS THERMOWELL 66 138 0 ÷ +40 -29 ÷+100 49 - PFR50001000S511 ABB TWS
TW-23-242-ON INLET GAS THERMOWELL 66 138 0 ÷ +40 -29 ÷+100 49 - PFR50001000S511 ABB TWS
TW-23-252-ON INLET GAS THERMOWELL 66 138 0 ÷ +40 -29 ÷+100 49 - PFR50001000S511 ABB TWS
NOTES:
(1) EQUIMPENT SHALL BE TROPICALIZED IN COMPLIANCE WITH THE ATTACHED ENI SPEC. 05497.VAR.ELE.STD_05 FOR HOT WET TROPICAL CLIMATE
(2) STANDARD MANUFACTURER PAINTING COMPATIBLE WITH MARINE C5I ENVIRONMENT (ISO 12944)
(3) IEC-EX & CERTIFICATE REQUIRED
(4) EQUIMPENT SHALL BE TESTED IN COMPLIANCE WITH ATTACHED INSPECTION DATASHEET 351700BMGB30200 (pages 10 to 13)
(5) C/W EN10204 3.1 CERTIFICATE OF MATERIALS FOR THERMOWELL
(6) C/W CERTIFICATE OF CALIBRATION
(7) C/W SIL CERTIFICATE
(8) THERMOWELL CALCULATION SHEET REQUIRED, ACC. TO ASME PTC 19.3 TW-2016 @ T=30 °C, P=26,5 barg, velocity=27 m/s, medium density=22,5 kg/m³
(9) C/W TAG PLATE IN SS WITH ENGRAVED TAG NUMBER
Document classified as: 2 - Company Confidential #
Sheet of Sheets
Company Document ID 351701DIGSF0053 10/30
Contractor Document ID 24640401MIIBF0053 Validity Status Revision Number
TEMPERATURE SWITCHES
DATA SHEET
PROJECT REF.: REV. DATE DESCRIPTION BY CHK'D APPR.
TAKORADI-TEMA INTERCONNECTION
A 10/11/2017 FIRST ISSUE F.B. D.R. A.S.
PROJECT (TTIP)
DOCUMENT TITLE : B 19/12/2017 FIRST REVISION F.B. D.R. A.S.
INSTRUMENTS SPECIFICATIONS AND
C 16/02/2018 SECOND REVISION F.B. D.R. A.S.
DATASHEETS
LOCATION : D 31/05/2018 APPROVED FOR CONSTRUCTION F.B. D.R. A.S.
GHANA
1. Tag No. See below Service: Exhaust stack inlet
2. Function Record Indicate Control Blind Trans
Other THERMOSWITCH
3. Case MFR STD Nom. Size Color: MFR STD Other
4. Mounting Flush Surface Yoke Other 2" pipe mounting
5. Enclosure Class General Purpose Weather Proof Expl. Proof Ex-d Class
For Use In Intrin. Safe System Other Ex-d IIB T4 - min. IP65 - TROPICALIZED (1)
GENERAL
6. Power Supply 110V 60Hz 220V 50Hz 24Vdc Other
7. Chart Strip Roll Fold Circular Time Marks
Range Number
8. Chart Drive Speed Power
9. Scales Type
Range 1 2 3 4
10. Transmitter 4÷20 mA 10÷50 mA 3÷15 psig Other
XMTR
Output For Receiver See Spec. Sheet
11. Control Modes P = Prop (Gain), I = Integral (AutoReset), D = Derivate (Rate)
Sub: s = Slow f = Fast
P PI PD PID If Df Is Ds
Other
CONTROLLER 12. Action On meas. Increase output: Increases Decreases
13. Auto-Man Switch None MFR STD Other
14. Set Point Adj. Manual External Remote Other Factory set
15. Manual Reg. None MFR STD Other
16. Output 4÷20 mA 10÷50 mA 3÷15 psig Other
17. Fill SAMA Class Compensation
18. Process Data Temp: Normal Max Max Press.
19. Range Fixed Adj. Range +200 to +350 °C Set at +300 °C
Overrange protection to
20. Bulb Type Mtl. Extension: Lenght Type
ELEMENT
Size: Diameter Lenght Insertion
Conn: Lenght m Above Below Instr.
21. Capillary MFR STD Lenght 5m Mtl. Armor
22. Well Mtl. SS 316 Insertion 500 mm Lag Ext. VENDOR STD Conn 2"ANSI 150 RF
Constr: Drilled Built-Up Other TAPERED - 1/2" NPT INSTRUM
23. Alarm Switches Quantity 1 Form SPDT Rating 5A - 24 Vdc
24. Function Temp Deviation Contacts to On Temp Increase
25. Options Filter Reg Supply Gage Output Gage Charts
OPTIONS Other
ELECTRICAL CONNECTION 1/2"NPT-F, SIL 2 LEVEL CERTIFIED
26. MFR & Model No. BETA BV model. W3-T588H-CXX-S0-N1-V-Y
DESCRIPTION Nozzle
Operat. Design. Operat. Design.
Inside Set at MANUFACT.
TAG Press. Press. Temp. Temp. P.F. CODE
Diameter (°C) Model
(barg) (barg) (°C) (°C)
(mm)
+300 BETA BV
TSH/TW-23-205-ON STACK TEMPERATURE SWITCH ATM ATM 0÷+265 +350 49
Temp rising
PFR50001000S503 W3-T588H
+300 BETA BV
TSH/TW-23-215-ON STACK TEMPERATURE SWITCH ATM ATM 0÷+265 +350 49
Temp rising
PFR50001000S503 W3-T588H
+300 BETA BV
TSH/TW-23-225-ON STACK TEMPERATURE SWITCH ATM ATM 0÷+265 +350 49
Temp rising
PFR50001000S503 W3-T588H
NOTES:
(1) EQUIMPENT SHALL BE TROPICALIZED IN COMPLIANCE WITH THE ATTACHED ENI SPEC. 05497.VAR.ELE.STD_05 FOR HOT WET TROPICAL CLIMATE
(2) STANDARD MANUFACTURER PAINTING COMPATIBLE WITH MARINE C5I ENVIRONMENT (ISO 12944)
(3) IEC-EX CERTIFICATE REQUIRED
(4) EQUIMPENT SHALL BE TESTED IN COMPLIANCE WITH ATTACHED INSPECTION DATASHEET 351700BMGB30200 (pages 10 to 13)
(5) C/W EN10204 3.1 CERTIFICATE OF MATERIALS FOR THERMOWELL
(6) C/W CERTIFICATE OF CALIBRATION
(7) C/W SIL CERTIFICATE
(8) C/W TAG PLATE IN SS WITH ENGRAVED TAG NUMBER
Document classified as: 2 - Company Confidential #
Sheet of Sheets
Company Document ID 351701DIGSF0053 11/30
Contractor Document ID 24640401MIIBF0053 Validity Status Revision Number
TEMPERATURE SWITCHES
DATA SHEET
PROJECT REF.: REV. DATE DESCRIPTION BY CHK'D APPR.
TAKORADI-TEMA INTERCONNECTION PROJECT
A 10/11/2017 FIRST ISSUE F.B. D.R. A.S.
(TTIP)
DOCUMENT TITLE : B 19/12/2017 FIRST REVISION F.B. D.R. A.S.
INSTRUMENTS SPECIFICATIONS AND
C 16/02/2018 SECOND REVISION F.B. D.R. A.S.
DATASHEETS
LOCATION : D 31/05/2018 APPROVED FOR CONSTRUCTION F.B. D.R. A.S.
GHANA
1. Tag No. See below Service: Hot Water
2. Function Record Indicate Control Blind Trans
Other THERMOSWITCH
3. Case MFR STD Nom. Size Color: MFR STD Other
4. Mounting Flush Surface Yoke Other Horizontal mounting
5. Enclosure Class General Purpose Weather Proof Expl. Proof Ex-d Class
For Use In Intrin. Safe System Other Ex-d IIB T4 - min. IP65 - TROPICALIZED (1)
GENERAL
6. Power Supply 110V 60Hz 220V 50Hz 24Vdc Other
7. Chart Strip Roll Fold Circular Time Marks
Range Number
8. Chart Drive Speed Power
9. Scales Type
Range 1 2 3 4
10. Transmitter 4÷20 mA 10÷50 mA 3÷15 psig Other
XMTR
Output For Receiver See Spec. Sheet
11. Control Modes P = Prop (Gain), I = Integral (AutoReset), D = Derivate (Rate)
Sub: s = Slow f = Fast
P PI PD PID If Df Is Ds
Other
CONTROLLER 12. Action On meas. Increase output: Increases Decreases
13. Auto-Man Switch None MFR STD Other
14. Set Point Adj. Manual External Remote Other Factory set
15. Manual Reg. None MFR STD Other
16. Output 4÷20 mA 10÷50 mA 3÷15 psig Other
17. Fill SAMA Class Compensation
18. Process Data Temp: Normal Max Max Press.
19. Range Fixed Adj. Range +60 to +100 °C Set at +93 °C
Overrange protection to
20. Bulb Type Mtl. Extension: Lenght Type
ELEMENT
Size: Diameter Lenght Insertion
Conn: Lenght m Above Below Instr.
21. Capillary MFR STD Lenght Mtl. Armor
22. Well Mtl. SS 316 Insertion 450 mm Lag Ext. VENDOR STD Conn 2"ANSI 150 RF
Constr: Drilled Built-Up Other TAPERED - 1/2" NPT INSTRUM
23. Alarm Switches Quantity 1 Form SPDT Rating 5A - 24 Vdc
24. Function Temp Deviation Contacts to On Temp Increase
25. Options Filter Reg Supply Gage Output Gage Charts
OPTIONS Other
ELECTRICAL CONNECTION 1/2"NPT-F, SIL 2 LEVEL CERTIFIED
26. MFR & Model No. BETA BV model W3-T568H-CXX-S0-N1-V-Y
Nozzle
Operat. Design. Operat. Design.
Inside Set at MANUFACT.
TAG DESCRIPTION Press. Press. Temp. Temp. P.F. CODE
Diameter (°C) Model
(barg) (barg) (°C) (°C)
(mm)
+93 BETA BV
TSHH/TW-23-203-ON WATER BATH TEMP. SWITCH ATM F.V./0,69 0÷+86 +100 49
Temp rising
PFR50001000S504 W3-T568H
+93 BETA BV
TSHH/TW-23-213-ON WATER BATH TEMP. SWITCH ATM F.V./0,69 0÷+86 +100 49
Temp rising
PFR50001000S504 W3-T568H
+93 BETA BV
TSHH/TW-23-223-ON WATER BATH TEMP. SWITCH ATM F.V./0,69 0÷+86 +100 49
Temp rising
PFR50001000S504 W3-T568H
NOTES:
(1) EQUIMPENT SHALL BE TROPICALIZED IN COMPLIANCE WITH THE ATTACHED ENI SPEC. 05497.VAR.ELE.STD_05 FOR HOT WET TROPICAL CLIMATE
(2) STANDARD MANUFACTURER PAINTING COMPATIBLE WITH MARINE C5I ENVIRONMENT (ISO 12944)
(3) IEC-EX CERTIFICATE REQUIRED
(4) EQUIMPENT SHALL BE TESTED IN COMPLIANCE WITH ATTACHED INSPECTION DATASHEET 351700BMGB30200 (pages 10 to 13)
(5) C/W EN10204 3.1 CERTIFICATE OF MATERIALS FOR THERMOWELL
(6) C/W CERTIFICATE OF CALIBRATION
(7) C/W SIL CERTIFICATE
(8) C/W TAG PLATE IN SS WITH ENGRAVED TAG NUMBER
Document classified as: 2 - Company Confidential #
Sheet of Sheets
Company Document ID 351701DIGSF0053 12/30
Revision
Contractor Document ID 24640401MIIBF0053 Validity Status
Number
Vendor Document ID 50001000A0IDS303EN EX-CO 00
TEMPERATURE GAUGES
DATA SHEET
PROJECT REF.: REV. DATE DESCRIPTION BY CHK'D APPR.
TAKORADI-TEMA INTERCONNECTION PROJECT
A 04/12/2017 FIRST ISSUE F.B. D.R. A.S.
(TTIP)
DOCUMENT TITLE : B 19/12/2017 FIRST REVISION F.B. D.R. A.S.
INSTRUMENTS SPECIFICATIONS AND
C 16/02/2018 SECOND REVISION F.B. D.R. A.S.
DATASHEETS
LOCATION : D 31/05/2018 APPROVED FOR CONSTRUCTION F.B. D.R. A.S.
GHANA
STEM
LENGTH 90°
135° 135° 135°
LENGTH
BOTTOM FIG. 2
FORM BACK FORM STRAIGHT BACK 135° RIGHT-LEFT
(STRAIGHT) (ANGLE) FIG. 3 FIG. 4 - 5 FIG. 6 - 7 FIG. 8 - 9
TG/TW-23-215-ON Water Bath Temperature ATM F.V./0,69 0÷+86 +100 49 0 ÷ 120 PFR50001000S505 WIKA - A5500
TG/TW-23-225-ON Water Bath Temperature ATM F.V./0,69 0÷+86 +100 49 0 ÷ 120 PFR50001000S505 WIKA - A5500
TG/TW-23-235-ON Water Bath Temperature ATM F.V./0,69 0÷+86 +100 49 0 ÷ 120 PFR50001000S505 WIKA - A5500
NOTES:
(1) CASE MATERIAL COMPATIBLE WITH MARINE C5I ENVIRONMENT (ISO 12944)
(2) ATEX CERTIFICATE REQUIRED
(3) EQUIMPENT SHALL BE TESTED IN COMPLIANCE WITH ATTACHED INSPECTION DATASHEET 351700BMGB30200 (pages 10 to 13)
(4) C/W EN10204 3.1 CERTIFICATE OF MATERIALS FOR THERMOWELL
(5) C/W CERTIFICATE OF CALIBRATION
(6) C/W TAG PLATE IN SS WITH ENGRAVED TAG NUMBER
(7) AMBIENT TEMEPRATURE: 21 °C to 31 °C
Document classified as: 2 - Company Confidential #
Sheet of Sheets
Company Document ID 351701DIGSF0053 13/30
LEVEL SWITCH
DATA SHEET
PROJECT REF.: REV. DATE DESCRIPTION BY CHK'D APPR.
TAKORADI-TEMA INTERCONNECTION PROJECT
A 29/11/2017 FIRST ISSUE F.B. D.R. A.S.
(TTIP)
DOCUMENT TITLE : B 19/12/2017 FIRST REVISION F.B. D.R. A.S.
INSTRUMENTS SPECIFICATIONS AND DATASHEETS
C 16/02/2018 SECOND REVISION F.B. D.R. A.S.
FOR INDIRECT FIRED HEATERS - ITEM FY2301 A/B/C
LOCATION : D 31/05/2018 APPROVED FOR CONSTRUCTION F.B. D.R. A.S.
GHANA
1 Tag Number LSLL-23-206-ON LSLL-23-216-ON LSLL-23-226-ON
2 No. Items 1 1 1
WATER EXP. TANK LEVEL WATER EXP. TANK LEVEL WATER EXP. TANK LEVEL
3 Service
SWITCH SWITCH SWITCH
XMTR / CONTR. 28 Output Action: SWITCH FOR LEVEL DECREASE SWITCH FOR LEVEL DECREASE SWITCH FOR LEVEL DECREASE
Sheet of Sheets
Company Document ID 351701DIGSF0053 14/30
Contractor Document ID 24640401MIIBF0053 Validity Status Revision Number
LEVEL GAUGE
DATA SHEET
PROJECT REF.: REV. DATE DESCRIPTION BY CHK'D APPR.
TAKORADI-TEMA INTERCONNECTION PROJECT
(TTIP)
A 29/11/2017 FIRST ISSUE F.B. D.R. A.S.
DOCUMENT TITLE : B 19/12/2017 FIRST REVISION F.B. D.R. A.S.
INSTRUMENTS SPECIFICATIONS AND
DATASHEETS
C 16/02/2018 SECOND REVISION F.B. D.R. A.S.
LOCATION : D 31/05/2018 APPROVED FOR CONSTRUCTION F.B. D.R. A.S.
GHANA
1. Gage Column Cocks GAGE COCKS
Assembled with Nipples Unassembled 8. Type: Offset Straight
GAGE GLASSES 9. Conn: Vessel 1" Gage 1/2"NPT Vent/Drain 1/2"NPT
2. Type: Reflex Transparen Tubolar 10. Material: Body SS 316 Trim S.S.
Large Chamber Weld Pad 11. Min. Rating: 0,69 bar/FULL VACUUM bar at 100 °C
3. Conn: Size and Type 1" ANSI 150 RF 12. Construction: FORGED
Top & Bot. Side Back 13. Type Of Conn: Vessel 1" ANSI 150RF
Vent GATE VALVE - 1/2"NPT Drain GATE VALVE - 1/2"NPT Gage 1/2" NIPPLE
4. Material SS 316 14. Bonnet SCREWED
5. Min. Rating 0,69 bar/FULL VACUUM bar at 100 °C 15. Options: Ball Check Renewable Seats
6. Options: Illuminator Mica Shield Other
Internal Tube External Jkt 16. MFR & Model N° SIMER model LGR 100
Non-Frost Ext. Lenght
Calb. Scale Other
7. MFR & Model N° SIMER model LGR 100
Operating
Rev Q.ty Tag N° Visible Glass CL. Conn. PF Code Services Note
Temp. (°C) Press. (barg)
A 1 LG-23-205-ON 1400 mm 1580 mm PFR50001000S507 +60 ÷ +90 ATM to 0,04 WATER LEVEL EXP. TANK see below
A 1 LG-23-215-ON 1400 mm 1580 mm PFR50001000S507 +60 ÷ +90 ATM to 0,04 WATER LEVEL EXP. TANK see below
A 1 LG-23-225-ON 1400 mm 1580 mm PFR50001000S507 +60 ÷ +90 ATM to 0,04 WATER LEVEL EXP. TANK see below
NOTES:
Sheet of Sheets
Company Document ID 351701DIGSF0053 15/30
Contractor Document ID 24640401MIIBF0053 Validity Status Revision Number
LEVEL TRANSMITTER
DATA SHEET
PROJECT REF.: REV. DATE DESCRIPTION BY CHK'D APPR.
TAKORADI-TEMA INTERCONNECTION
A 10/11/2017 FIRST ISSUE F.B. D.R. A.S.
PROJECT (TTIP)
DOCUMENT TITLE : B 19/12/2017 FIRST REVISION F.B. D.R. A.S.
INSTRUMENTS SPECIFICATIONS AND
C 16/02/2018 SECOND REVISION F.B. D.R. A.S.
DATASHEETS
LOCATION : D 31/05/2018 APPROVED FOR CONSTRUCTION F.B. D.R. A.S.
GHANA
1. Tag No. See below Service: Water Exp. Tank Level
2. Function Record Indicate Control Blind Trans
Other see notes
3. Case MFR STD Nom. Size Color: MFR STD Other
4. Mounting Flush Surface Yoke Other 2" pipe mounting
5. Enclosure Class General Purpose Weather Proof Expl. Proof Ex-d Class
For Use In Intrin. Safe System Other Ex-d IIB T4 - min. IP65 - TROPICALIZED (1)
GENERAL
6. Power Supply 110V 60Hz 220V 50Hz 24Vdc Other LOOP POWERED
7. Chart Strip Roll Fold Circular Time Marks
Range Number
8. Chart Drive Speed Power
9. Scales Type
Range 1 2 3 4
10. Transmitter 4÷20 mA 10÷50 mA 3÷15 psig Other Smart type (Hart Protocol)
XMTR
Output For Receiver See Spec. Sheet
11. Control Modes P = Prop (Gain), I = Integral (AutoReset), D = Derivate (Rate)
Sub: s = Slow f = Fast
P PI PD PID If Df Is Ds
Other
CONTROLLER 12. Action On meas. Increase output: Increases Decreases
13. Auto-Man Switch None MFR STD Other
14. Set Point Adj. Manual External Remote Other
15. Manual Reg. None MFR STD Other
16. Output 4÷20 mA 10÷50 mA 3÷15 psig Other
17. Service Flow Level Diff. Press. Other
18. Process Data Diaphragm Helix Bourdon Other
19. Material 316 SS Ber.Copper Other
Fixed Adj. Range 0 -1320 mmWC Set at 0 to 1200 mmWC
Overrange protection to
ELEMENT 20. Bulb Type Mtl. Extension: Lenght Type
Size: Diameter Lenght Insertion
Conn: Lenght m Above Below Instr.
21. Capillary MFR STD Lenght 5m Mtl. 316 SS Armor
22. Process connection Conn Remote Flanged Seals 2"ANSI 150 RF with identical capillary lenght
NOTES:
(1) EQUIMPENT SHALL BE TROPICALIZED IN COMPLIANCE WITH THE ATTACHED ENI SPEC. 05497.VAR.ELE.STD_05 FOR HOT WET TROPICAL CLIMATE
(2) STANDARD MANUFACTURER PAINTING COMPATIBLE WITH MARINE C5I ENVIRONMENT (ISO 12944)
(3) IEC-EX CERTIFICATE REQUIRED
(4) EQUIMPENT SHALL BE TESTED IN COMPLIANCE WITH ATTACHED INSPECTION DATASHEET 351700BMGB30200 (pages 10 to 13)
(5) C/W EN10204 3.1 CERTIFICATE OF MATERIALS FOR WETTED PARTS
(6) C/W CERTIFICATE OF CALIBRATION
(7) C/W TAG PLATE IN SS WITH ENGRAVED TAG NUMBER
(8) ZERO WILL BE SETTED AT 120 mm FROM BOTTOM FLANGE CENTER, MAX LEVEL WILL BE SETTED AT 1320 mm FROM BOTTOM FLANGE CENTER
Document classified as: 2 - Company Confidential
#
Sheet of Sheets
Company Document ID 351701DIGSF0053 16/30
Contractor Document ID 24640401MIIBF0053 Validity Status Revision Number
13. Options Duct mounting kit for remote sensor including calibration cap. Duct kit will be suitable to be
OPTIONS
connected to a 6" ANSI 150 RF Flanged connection. Junction box for sensor & weather protection canopy
14. MFR & Model No. HONEYWELL ANALYTICS model: SENSEPOINT (sensor) + XNX (transmitter)
DESCRIPTION Nozzle
Operat. Design. Operat. Design.
Inside Span set MANUFACT.
TAG Press. Press. Temp. Temp. P.F. CODE
Diameter (%LEL) Model
(mbarg) (barg) (°C) (°C)
(mm)
AE-23-201-ON GAS DETECTOR (SENSOR) ATM to 40 F.V./0,69 0÷+90 +100 77 0÷100% PFR50001000S509 SENSEPOINT
AT-23-201-ON GAS DETECTOR (Transmitter) ATM - 21÷+31 - - 0÷100% Included in sensor code XNX
AE-23-211-ON GAS DETECTOR (SENSOR) ATM to 40 F.V./0,69 0÷+90 +100 77 0÷100% PFR50001000S509 SENSEPOINT
AT-23-211-ON GAS DETECTOR (Transmitter) ATM - 21÷+31 - - 0÷100% Included in sensor code XNX
AE-23-221-ON GAS DETECTOR (SENSOR) ATM to 40 F.V./0,69 0÷+90 +100 77 0÷100% PFR50001000S509 SENSEPOINT
AT-23-221-ON GAS DETECTOR (Transmitter) ATM - 21÷+31 - - 0÷100% Included in sensor code XNX
NOTES:
(1) EQUIMPENT SHALL BE TROPICALIZED IN COMPLIANCE WITH THE ATTACHED ENI SPEC. 05497.VAR.ELE.STD_05 FOR HOT WET TROPICAL CLIMATE
(2) STANDARD MANUFACTURER PAINTING COMPATIBLE WITH MARINE C5I ENVIRONMENT (ISO 12944)
(3) IEC-EX CERTIFICATE REQUIRED
(4) EQUIMPENT SHALL BE TESTED IN COMPLIANCE WITH ATTACHED INSPECTION DATASHEET 351700BMGB30200 (pages 10 to 13)
(5) C/W EN10204 3.1 CERTIFICATE OF MATERIALS FOR THERMOWELL
(5) C/W CERTIFICATE OF CALIBRATION
(6) C/W TAG PLATE IN SS WITH ENGRAVED TAG NUMBER
(7) C/W SIL CERTIFICATE
Document classified as: 2 - Company Confidential #
Sheet of Sheets
Company Document ID 351701DIGSF0053 17/30
Contractor Document ID 24640401MIIBF0053 Validity Status Revision Number
PRESSURE GAUGE
DATA SHEET
PROJECT REF.: REV. DATE DESCRIPTION BY CHK'D APPR.
TAKORADI-TEMA INTERCONNECTION
A 05/12/2017 FIRST ISSUE F.B. D.R. A.S.
PROJECT (TTIP)
DOCUMENT TITLE : B 19/12/2017 FIRST REVISION F.B. D.R. A.S.
INSTRUMENTS SPECIFICATIONS AND
C 16/02/2018 SECOND REVISION F.B. D.R. A.S.
DATASHEETS
LOCATION : D 31/05/2018 APPROVED FOR CONSTRUCTION F.B. D.R. A.S.
GHANA
1. Type: Direct Rdg 3-15 Ib Receiver 10. Manufacturer WIKA
Other EN 837-1 Model No. 233.30
2. Mounting: Surface Local Flush 11. Press. Element: Bourdon Bellows
3. Dial: Diameter DN 100 (270°) Color Wh.all/bk let.din 6203 Other
4. Case: Cast Iron Aluminum ABS 12. Element Mtl: Bronze Steel 316 SS
Other STAINLESS STEEL Other
5. Ring: Screwed Hinged Slip Std 13. Socket Mtl: Bronze Steel 316 SS
Other Cam ring (bayonet type), natural finish ss Other
6. Blow-Out Protection: None Back Disc 14. Connection: ¼"NPT ½"NPT Other
Solid Front Other IP 65 min. Bottom Back
7. Lens: Glass Plastic 15. Movement: Bronze SS Nylon
8. Options: Sylphon Material Other Pointer alluminium, black
Snubber 16. Filling fluid Glycerine with Safety plug
Blow out protect. 17. Connections Gage Conn. 1/2" NPT-M
Pressure Limit Valve 18. Diaphragm Seal YES NO
Movement Damping MFG Type
9. Nominal Accuracy Required ± 1.0% OF FULL SCALE READING Wetted Pert Mtl. Other Mtl.
Fill Fluid
Process Conn. Gage Conn.
PG-23-205-ON GAS INLET PRESSURE 66 138 0 ÷ +40 -29 ÷ +100 0 ÷ 160 PFR50001000S512 WIKA 233.30
PG-23-215-ON GAS INLET PRESSURE 66 138 0 ÷ +40 -29 ÷ +100 0 ÷ 160 PFR50001000S512 WIKA 233.30
PG-23-225-ON GAS INLET PRESSURE 66 138 0 ÷ +40 -29 ÷ +100 0 ÷ 160 PFR50001000S512 WIKA 233.30
PG-23-203-ON GAS OUTLET PRESSURE 66 138 0 ÷ +40 -29 ÷ +100 0 ÷ 160 PFR50001000S512 WIKA 233.30
PG-23-213-ON GAS OUTLET PRESSURE 66 138 0 ÷ +40 -29 ÷ +100 0 ÷ 160 PFR50001000S512 WIKA 233.30
PG-23-223-ON GAS OUTLET PRESSURE 66 138 0 ÷ +40 -29 ÷ +100 0 ÷ 160 PFR50001000S512 WIKA 233.30
NOTES:
(1) CASE MATERIAL COMPATIBLE WITH MARINE C5I ENVIRONMENT (ISO 12944)
(2) ATEX CERTIFICATE REQUIRED
(3) EQUIMPENT SHALL BE TESTED IN COMPLIANCE WITH ATTACHED INSPECTION DATASHEET 351700BMGB30200 (pages 10 to 13)
(4) C/W EN10204 3.1 CERTIFICATE OF MATERIALS FOR WETTED PARTS
(5) C/W CERTIFICATE OF CALIBRATION
(6) C/W TAG PLATE IN SS WITH ENGRAVED TAG NUMBER
(7) AMBIENT TEMEPRATURE: 21 °C to 31 °C
Document classified as: 2 - Company Confidential #
Sheet of Sheets
Company Document ID 351701DIGSF0053 18/30
Contractor Document ID 24640401MIIBF0053 Validity Status Revision Number
MANIFOLD
note:
(1) DESIGN TEMPERATURE: -29÷+100°C (Operative +40°C) / Ambient conditions: temperature 21°C to 31°C
(2) DESIGN PRESSURE: 138 barg
(3) WHOLE IN AISI316L
(4) SUITABLE FOR C5I ENVIRONMENT AS PER MANUFACTURER STANDARD
(5) MATERIAL CERTIFICATION ACCORDING TO EN10204-3.1 (ISO10474-3.1) AND MANUFACTURER’S TEST REPORT
Sheet of Sheets
Company Document ID 351701DIGSF0053 19/30
Contractor Document ID 24640401MIIBF0053 Validity Status Revision Number
NOTES:
(1) CASE MATERIAL COMPATIBLE WITH MARINE C5I ENVIRONMENT (ISO 12944)
(2) ATEX CERTIFICATE REQUIRED
(3) EQUIMPENT SHALL BE TESTED IN COMPLIANCE WITH ATTACHED INSPECTION DATASHEET 351700BMGB30200 (pages 10 to 13)
(4) C/W EN10204 3.1 CERTIFICATE OF MATERIALS FOR WETTED PARTS
(5) C/W CERTIFICATE OF CALIBRATION
(6) C/W TAG PLATE IN SS WITH ENGRAVED TAG NUMBER
(7) AMBIENT TEMEPRATURE: 21 °C to 31 °C
Document classified as: 2 - Company Confidential #
Sheet of Sheets
Company Document ID 351701DIGSF0053 20/30
Contractor Document ID 24640401MIIBF0053 Validity Status Revision Number
MANIFOLD
note:
(1) DESIGN TEMPERATURE: -29÷+100°C (Operative +40°C) / Ambient conditions: temperature 21°C to 31°C
(2) DESIGN PRESSURE: 138 barg
(3) WHOLE IN AISI316L
(4) SUITABLE FOR C5I ENVIRONMENT AS PER MANUFACTURER STANDARD
(5) MATERIAL CERTIFICATION ACCORDING TO EN10204-3.1
Sheet of Sheets
Company Document ID 351701DIGSF0053 21/30
Contractor Document ID 24640401MIIBF0053 Validity Status Revision Number
SECTION 2:
INSTRUMENTATION INCLUDED IN THE FUEL GAS
LINE AND BURNER PACKAGE
Document classified as: 2 - Company Confidential
#
Sheet of Sheets
Company Document ID 351701DIGSF0053 22/30
Contractor Document ID 24640401MIIBF0053 Validity Status Revision Number
PRESSURE GAUGE
DATA SHEET
PROJECT REF.: REV. DATE DESCRIPTION BY CHK'D APPR.
TAKORADI-TEMA INTERCONNECTION
A 05/12/2017 FIRST ISSUE F.B. D.R. A.S.
PROJECT (TTIP)
DOCUMENT TITLE : B 19/12/2017 FIRST REVISION F.B. D.R. A.S.
INSTRUMENTS SPECIFICATIONS AND
C 16/02/2018 SECOND REVISION F.B. D.R. A.S.
DATASHEETS
LOCATION : D 31/05/2018 APPROVED FOR CONSTRUCTION F.B. D.R. A.S.
GHANA
1. Type: Direct Rdg 3-15 Ib Receiver 10. Manufacturer WIKA
Other EN 837-1 Model No. 233.50.100
2. Mounting: Surface Local Flush 11. Press. Element: Bourdon Bellows
3. Dial: Diameter DN 100 (270°) Color Wh.all/bk let.din 6203 Other
4. Case: Cast Iron Aluminum ABS 12. Element Mtl: Bronze Steel 316 SS
Other STAINLESS STEEL Other
5. Ring: Screwed Hinged Slip Std 13. Socket Mtl: Bronze Steel 316 SS
Other Cam ring (bayonet type), natural finish ss Other
6. Blow-Out Protection: None Back Disc 14. Connection: ¼"NPT ½"NPT Other
Solid Front Other IP 65 min. Bottom Back
7. Lens: Glass Plastic 15. Movement: Bronze SS Nylon
8. Options: Sylphon Material Other Pointer alluminium, black
Snubber 16. Filling fluid Glycerine with Safety plug
Blow out protect. 17. Connections Gage Conn. 1/2" NPT-M
Pressure Limit Valve 18. Diaphragm Seal YES NO
Movement Damping MFG Type
9. Nominal Accuracy Required ± 1.0% OF FULL SCALE READING Wetted Pert Mtl. Other Mtl.
Fill Fluid
Process Conn. Gage Conn.
Line Line PSV Additional
Operat. Operat. Design.
Design. present SCALE RANGE Over- MANUFACT.
TAG DESCRIPTION Press. Temp. Temp. P.F. CODE
Press. set@ (barg) pressure Model
(barg) (°C) (°C)
(barg) (barg) protection
PG-23-206-
FUEL GAS INLET PRESSURE 10 12 No +20 -29 ÷ +80 0 ÷ 16 No WIKA 233.50.100
ON
PG-23-216-
FUEL GAS INLET PRESSURE 10 12 No +20 -29 ÷ +80 0 ÷ 16 No WIKA 233.50.100
ON
PG-23-226-
FUEL GAS INLET PRESSURE 10 12 No +20 -29 ÷ +80 0 ÷ 16 No WIKA 233.50.100
ON
NOTES:
(1) CASE MATERIAL COMPATIBLE WITH MARINE C5I ENVIRONMENT (ISO 12944)
(2) ATEX CERTIFICATE REQUIRED
(3) EQUIMPENT SHALL BE TESTED IN COMPLIANCE WITH ATTACHED INSPECTION DATASHEET 351700BMGB30200 (pages 10 to 13)
(4) C/W EN10204 3.1 CERTIFICATE OF MATERIALS FOR WETTED PARTS
(5) C/W CERTIFICATE OF CALIBRATION
(6) C/W TAG PLATE IN SS WITH ENGRAVED TAG NUMBER
(7) AMBIENT TEMEPRATURE: 21 °C to 31 °C
(8) THE PRESSURE GAUGE SHALL BE DESIGNED TO WITHSTAND A STATIC PRESSURE OF 4 BARG, OTHERWISE AN OVERPRESSURE DEVICE SHALL BE
PROVIDED FOR EACH MANOMETER
Document classified as: 2 - Company Confidential #
Sheet of Sheets
Company Document ID 351701DIGSF0053 23/30
Contractor Document ID 24640401MIIBF0053 Validity Status Revision Number
PRESSURE SWITCH
DATA SHEET
PROJECT REF.: REV. DATE DESCRIPTION BY CHK'D APPR.
TAKORADI-TEMA INTERCONNECTION
PROJECT (TTIP)
A 05/12/2017 FIRST ISSUE F.B. D.R. A.S.
DOCUMENT TITLE : B 19/12/2017 FIRST REVISION F.B. D.R. A.S.
INSTRUMENTS SPECIFICATIONS AND
C 16/02/2018 SECOND REVISION F.B. D.R. A.S.
DATASHEETS
LOCATION : D 31/05/2018 APPROVED FOR CONSTRUCTION F.B. D.R. A.S.
GHANA
GENERAL SWITCH
1. Type: Press Vacuum 8. Type: Mercury Snap
Comp. Diff. Press. Other
2. Setting: Set in Field Factory Set 9. Quantity: Single Dual
Internal External Dial 10. Form: SPST SPDT DPDT
3. Dead Band: Fixed Adj Min Other
ELEMENT 11. Rating: 2 Amps 30 Vdc Hz
4. Type: Diaphragm Bourdon Bellows Other
Other 12. Load: Inductive Non-Inductive
5. Material: Bronze 316 SS Alloy St. 13. Enclosure: General Purpose Weather proof
Other None Expl. Proof Ex-d IIB T4 - min. IP65 (1)
6. Connection: MFR STD Other Size 1/2" NPT-F 14. Conduit Connection: MFR STD Other M20
Bottom Back 15. Other: SIL 2, SS 316 HOUSING, SEE NOTES BELOW
7. Mounting: Local Surface Flush Manufacturer BETA
Model No. W3-P502H-S2N-B1-N1-V / W3-P404M-S2N-B1-N1-V
VERY LOW
0,35
PSLL-23-203-ON PRESSURE 0,5 12 +15 -29 ÷ +80 0,3-1.6 200 W8-P502H-S2N-B1-N1-V
Decreasing
SWITCH
VERY LOW
0,35
PSLL-23-213-ON PRESSURE 0,5 12 +15 -29 ÷ +80 0,3-1.6 200 W8-P502H-S2N-B1-N1-V
Decreasing
SWITCH
VERY LOW
0,35
PSLL-23-223-ON PRESSURE 0,5 12 +15 -29 ÷ +80 0,3-1.6 200 W8-P502H-S2N-B1-N1-V
Decreasing
SWITCH
VERY HIGH
0,287
PSHH-23-201-ON PRESSURE 0,5 12 +15 -29 ÷ +80 0,1-0,95 125 W8-P404M-S2N-B1-N1-V
Increasing
SWITCH
VERY HIGH
0,287
PSHH-23-211-ON PRESSURE 0,5 12 +15 -29 ÷ +80 0,1-0,95 125 W8-P404M-S2N-B1-N1-V
Increasing
SWITCH
VERY HIGH
0,287
PSHH-23-221-ON PRESSURE 0,5 12 +15 -29 ÷ +80 0,1-0,95 125 W8-P404M-S2N-B1-N1-V
Increasing
SWITCH
NOTES:
(1) EQUIMPENT SHALL BE TROPICALIZED IN COMPLIANCE WITH THE ATTACHED ENI SPEC. 05497.VAR.ELE.STD_05 FOR HOT WET TROPICAL CLIMATE
(2) STANDARD MANUFACTURER PAINTING COMPATIBLE WITH MARINE C5I ENVIRONMENT (ISO 12944)
(3) IEC-EX CERTIFICATE REQUIRED
(4) EQUIMPENT SHALL BE TESTED IN COMPLIANCE WITH ATTACHED INSPECTION DATASHEET 351700BMGB30200 (pages 10 to 13)
(5) C/W EN10204 3.1 CERTIFICATE OF MATERIALS FOR WETTED PARTS
(6) C/W CERTIFICATE OF CALIBRATION
(7) C/W SIL CERTIFICATE
(8) C/W TAG PLATE IN SS WITH ENGRAVED TAG NUMBER
Document classified as: 2 - Company Confidential #
Sheet of Sheets
Company Document ID 351701DIGSF0053 24/30
Contractor Document ID 24640401MIIBF0053 Validity Status Revision Number
UE
10
PDSLL-23-202-ON VERY LOW PESSURE SWITCH 0,05 0,15 +21÷+31 -29 ÷ +80 +1,7/+25 12SHSNK1*M480*M201
Decreasing *M423SS
UE
10
PDSLL-23-212-ON VERY LOW PESSURE SWITCH 0,05 0,15 +21÷+31 -29 ÷ +80 +1,7/+25 12SHSNK1*M480*M201
Decreasing *M423SS
UE
10
PDSLL-23-222-ON VERY LOW PESSURE SWITCH 0,05 0,15 +21÷+31 -29 ÷ +80 +1,7/+25 12SHSNK1*M480*M201
Decreasing *M423SS
NOTES:
(1) EQUIMPENT SHALL BE TROPICALIZED IN COMPLIANCE WITH THE ATTACHED ENI SPEC. 05497.VAR.ELE.STD_05 FOR HOT WET TROPICAL CLIMATE
(2) STANDARD MANUFACTURER PAINTING COMPATIBLE WITH MARINE C5I ENVIRONMENT (ISO 12944)
(3) IEC-EX CERTIFICATE REQUIRED
(4) EQUIMPENT SHALL BE TESTED IN COMPLIANCE WITH ATTACHED INSPECTION DATASHEET 351700BMGB30200 (pages 10 to 13)
(5) C/W EN10204 3.1 CERTIFICATE OF MATERIALS FOR WETTED PARTS
(6) C/W CERTIFICATE OF CALIBRATION
(7) C/W SIL CERTIFICATE
(8) C/W TAG PLATE IN SS WITH ENGRAVED TAG NUMBER
Document classified as: 2 - Company Confidential #
Sheet of Sheets
Company Document ID 351701DIGSF0053 25/30
Contractor Document ID 24640401MIIBF0053 Validity Status Revision Number
MANIFOLD
note:
(1) DESIGN TEMPERATURE: -29÷+80°C (Operative +20°C) / Ambient conditions: temperature 21°C to 31°C
(2) DESIGN PRESSURE: 12 barg
(3) WHOLE IN AISI316L
(4) SUITABLE FOR C5I ENVIRONMENT AS PER MANUFACTURER STANDARD
(5) MATERIAL CERTIFICATION ACCORDING TO EN10204-3.1 (ISO10474-3.1) AND MANUFACTURER’S TEST REPORT
C MF-015A-ON, MF-015B-ON, MF-015C-ON, MF-021A-ON, MF-021B-ON, MF-021C-ON, MF-022A-ON, MF-022B-ON, MF-022C-ON, MF-024A-ON, MF-024B-ON, 15
MF-024C-ON, MF-025A-ON, MF-025B-ON, MF-025C-ON
Sheet of Sheets
Company Document ID 351701DIGSF0053 26/30
Contractor Document ID 24640401MIIBF0053 Validity Status Revision Number
MANIFOLD
note:
(1) DESIGN TEMPERATURE: -29÷+80°C (Operative +20°C) / Ambient conditions: temperature 21°C to 31°C
(2) DESIGN PRESSURE: 12 barg
(3) WHOLE IN AISI316L
(4) SUITABLE FOR C5I ENVIRONMENT AS PER MANUFACTURER STANDARD
(5) MATERIAL CERTIFICATION ACCORDING TO EN10204-3.1 (ISO10474-3.1) AND MANUFACTURER’S TEST REPORT
Sheet of Sheets
Company Document ID 351701DIGSF0053 27/30
Contractor Document ID 24640401MIIBF0053 Validity Status Revision Number
MANIFOLD
note:
(1) DESIGN TEMPERATURE: -29÷+80°C (Operative +20°C) / Ambient conditions: temperature 21°C to 31°C
(2) DESIGN PRESSURE: 0,1 barg
(3) WHOLE IN AISI316L
(4) SUITABLE FOR C5I ENVIRONMENT AS PER MANUFACTURER STANDARD
(5) MATERIAL CERTIFICATION ACCORDING TO EN10204-3.1 (ISO10474-3.1) AND MANUFACTURER’S TEST REPORT
Sheet of Sheets
Company Document ID 351701DIGSF0053 28/30
Contractor Document ID 24640401MIIBF0053 Validity Status Revision Number
SOLENOID VALVES
DATA SHEET
CUSTOMER'S REF.: REV. DATE DESCRIPTION BY CHK'D APPR.
TAKORADI-TEMA INTERCONNECTION
A 06/12/2017 FIRST ISSUE F.B. D.R. A.S.
PROJECT (TTIP)
TITLE : B 19/12/2017 FIRST REVISION F.B. D.R. A.S.
INSTRUMENTS SPECIFICATIONS AND
C 16/02/2018 SECOND REVISION F.B. D.R. A.S.
DATASHEETS
LOCATION : D 31/05/2018 APPROVED FOR CONSTRUCTION F.B. D.R. A.S.
GHANA
Sheet of Sheets
Company Document ID 351701DIGSF0053 29/30
Contractor Document ID 24640401MIIBF0053 Validity Status Revision Number
COMITES
TT-23-237A-ON BLOWER CASE TEMP. KD2301A 0,05 0,15 +21÷+31 100 -50÷150 °C 100 100
R1B-1-B-3F-60-X-100
COMITES
TT-23-237B-ON BLOWER BEARINGS TEMP. KD2301A 0,05 0,15 +21÷+31 100 -50÷150 °C 150 100
R1B-1-B-3F-60-X-150
COMITES
TT-23-237C-ON BLOWER BEARINGS TEMP. KD2301A 0,05 0,15 +21÷+31 100 -50÷150 °C 150 100
R1B-1-B-3F-60-X-150
COMITES
TT-23-247A-ON BLOWER CASE TEMP. KD2301B 0,05 0,15 +21÷+31 100 -50÷150 °C 100 100
R1B-1-B-3F-60-X-100
COMITES
TT-23-247B-ON BLOWER BEARINGS TEMP. KD2301B 0,05 0,15 +21÷+31 100 -50÷150 °C 150 100
R1B-1-B-3F-60-X-150
COMITES
TT-23-247C-ON BLOWER BEARINGS TEMP. KD2301B 0,05 0,15 +21÷+31 100 -50÷150 °C 150 100
R1B-1-B-3F-60-X-150
COMITES
TT-23-257A-ON BLOWER CASE TEMP. KD2301C 0,05 0,15 +21÷+31 100 -50÷150 °C 100 100
R1B-1-B-3F-60-X-100
COMITES
TT-23-257B-ON BLOWER BEARINGS TEMP. KD2301C 0,05 0,15 +21÷+31 100 -50÷150 °C 150 100
R1B-1-B-3F-60-X-150
COMITES
TT-23-257C-ON BLOWER BEARINGS TEMP. KD2301C 0,05 0,15 +21÷+31 100 -50÷150 °C 150 100
R1B-1-B-3F-60-X-150
NOTES:
(1) EQUIMPENT SHALL BE TROPICALIZED IN COMPLIANCE WITH THE ATTACHED ENI SPEC. 05497.VAR.ELE.STD_05 FOR HOT WET TROPICAL CLIMATE
(2) STANDARD MANUFACTURER PAINTING COMPATIBLE WITH MARINE C5I ENVIRONMENT (ISO 12944)
(3) EQUIMPENT SHALL BE TESTED IN COMPLIANCE WITH ATTACHED INSPECTION DATASHEET 351700BMGB30200 (pages 10 to 13)
(4) C/W EN10204 3.1 CERTIFICATE OF MATERIALS FOR THERMOWELL
(5) C/W CERTIFICATE OF CALIBRATION
(6) C/W SIL CERTIFICATE
(7) C/W TAG PLATE IN SS WITH ENGRAVED TAG NUMBER
Document classified as: 2 - Company Confidential #
Sheet of Sheets
Company Document ID 351701DIGSF0053 30/30
Contractor Document ID 24640401MIIBF0053 Validity Status Revision Number
CEMB
VT-23-201A-ON BLOWER VIBRATION TRANSM. KD2301A 0,05 0,15 +21÷+31 100 0÷20 11 TR-I /1/1/2/0
CEMB
VT-23-201B-ON BLOWER VIBRATION TRANSM. KD2301A 0,05 0,15 +21÷+31 100 0÷20 11 TR-I /1/1/2/0
CEMB
VT-23-211A-ON BLOWER VIBRATION TRANSM. KD2301A 0,05 0,15 +21÷+31 100 0÷20 11 TR-I /1/1/2/0
CEMB
VT-23-211B-ON BLOWER VIBRATION TRANSM. KD2301A 0,05 0,15 +21÷+31 100 0÷20 11 TR-I /1/1/2/0
CEMB
VT-23-221A-ON BLOWER VIBRATION TRANSM. KD2301A 0,05 0,15 +21÷+31 100 0÷20 11 TR-I /1/1/2/0
CEMB
VT-23-221B-ON BLOWER VIBRATION TRANSM. KD2301A 0,05 0,15 +21÷+31 100 0÷20 11 TR-I /1/1/2/0
NOTES:
(1) EQUIMPENT SHALL BE TROPICALIZED IN COMPLIANCE WITH THE ATTACHED ENI SPEC. 05497.VAR.ELE.STD_05 FOR HOT WET TROPICAL CLIMATE
(2) STANDARD MANUFACTURER PAINTING COMPATIBLE WITH MARINE C5I ENVIRONMENT (ISO 12944)
(3) EQUIMPENT SHALL BE TESTED IN COMPLIANCE WITH ATTACHED INSPECTION DATASHEET 351700BMGB30200 (pages 10 to 13)
(4) C/W EN10204 3.1 CERTIFICATE OF MATERIALS FOR THERMOWELL
(5) C/W CERTIFICATE OF CALIBRATION
(6) C/W SIL CERTIFICATE
(7) C/W TAG PLATE IN SS WITH ENGRAVED TAG NUMBER