Série Condensateurs 136 Vishay
Série Condensateurs 136 Vishay
Série Condensateurs 136 Vishay
www.vishay.com
Vishay BCcomponents
Aluminum Capacitors
Radial Very Low Impedance
FEATURES
• Very low impedance and low ESR
• Very long useful life:
4000 h to 10 000 h at 105 °C, very high reliability
• Excellent ripple current capability
• Polarized aluminum electrolytic capacitors, non-solid
electrolyte
• Radial leads, cylindrical aluminum case with pressure
relief, insulated with a blue sleeve
• Charge and discharge proof
140 RTM
125 C • Material categorization: for definitions of compliance
please see www.vishay.com/doc?99912
higher
temperature
APPLICATIONS
136 RVI miniaturized 150 RMI • Power supplies (SMPS, DC/DC converters) for general
industrial, EDP, audio-video, and telecommunications
higher • Smoothing, filtering, buffering
CV/volume
MARKING
048 RML miniaturized 148 RUS
The capacitors are marked (where possible) with the
Fig. 1
following information:
• Rated capacitance value (in μF)
QUICK REFERENCE DATA
• Tolerance on rated capacitance, code letter in accordance
DESCRIPTION VALUE
with IEC 60062 (M for ± 20 %)
Nominal case sizes (Ø D x L in mm) 10 x 12 to 18 x 35
Rated capacitance range, CR 22 μF to 10 000 μF • Rated voltage (in V)
Tolerance on CR ± 20 % • Date code, in accordance with IEC 60062
Rated voltage range, CR 10 V to 100 V • Code indicating factory of origin
Category temperature range -55 °C to +105 °C
• Name of manufacturer
3000 h to 5000 h
Endurance test at 105 °C
(dependent on case size) • Upper category temperature (105 °C)
4000 h to 10 000 h
Useful life at 105 °C
(dependent on case size)
• Negative terminal identification
Useful life at 40 °C, 200 000 h to 500 000 h • Series number (136)
1.8 x IR applied (dependent on case size)
Shelf life at 0 V, 105 °C 1000 h
Based on sectional specification IEC 60384-4/EN130300
Climatic category IEC 60 068 55/105/56
SELECTION CHART FOR CR, UR, AND RELEVANT NOMINAL CASE SIZES (Ø D x L in mm)
CR UR (V)
(μF) 10 16 25 35 50 63 100
22 - - - - - - 10 x 12
33 - - - - - - 10 x 12
47 - - - - - 10 x 12 10 x 16
56 - - - - - 10 x 12 -
68 - - - - - 10 x 16 10 x 20
82 - - - - 10 x 12 - -
100 - - - - 10 x 12 10 x 16 12.5 x 20
- - - 10 x 12 10 x 16 10 x 20 -
120
- - - - - 12.5 x 16 -
150 - - - 10 x 12 10 x 20 10 x 25 16 x 20
- - 10 x 12 - 10 x 20 10 x 30 -
180
- - - - 12.5 x 16 - -
220 - - 10 x 12 10 x 16 10 x 25 12.5 x 20 16 x 25
270 - 10 x 12 - - - 12.5 x 25 -
- 10 x 12 10 x 16 10 x 20 10 x 30 16 x 20 16 x 31
330
- - - 12.5 x 16 12.5 x 20 - -
390 10 x 12 - - 10 x 25 - 12.5 x 31 -
10 x 12 10 x 16 10 x 20 12.5 x 20 12.5 x 25 16 x 25 16 x 35
470
- - 12.5 x 16 - - - 18 x 31
- - 10 x 25 10 x 30 12.5 x 31 - -
560
- - - 12.5 x 20 - - -
10 x 16 10 x 20 - 12.5 x 25 16 x 20 16 x 31 18 x 35
680
- 12.5 x 16 - - - 18 x 25 -
- 10 x 25 10 x 30 - 16 x 25 16 x 35 -
820
- - 12.5 x 20 - - - -
10 x 20 12.5 x 20 12.5 x 25 12.5 x 31 16 x 31 18 x 31 -
1000
12.5 x 16 - - 16 x 20 18 x 20 - -
10 x 25 10 x 30 - 16 x 25 16 x 35 - -
1200
- 12.5 x 20 - - - - -
10 x 30 12.5 x 25 12.5 x 31 16 x 25 18 x 31 18 x 35 -
1500
12.5 x 20 - 16 x 20 - - - -
1800 12.5 x 20 - 16 x 25 16 x 31 - - -
12.5 x 25 12.5 x 31 16 x 31 16 x 35 18 x 35 - -
2200
- 16 x 20 18 x 20 18 x 31 - - -
2700 12.5 x 31 16 x 25 16 x 31 - - - -
16 x 20 16 x 25 16 x 35 18 x 35 - - -
3300
- - 18 x 31 - - - -
3900 16 x 25 16 x 31 - - - - -
16 x 31 16 x 35 18 x 35 - - - -
4700
- 18 x 31 - - - - -
16 x 31 - - - - - -
5600
18 x 25 - - - - - -
16 x 35 18 x 35 - - - - -
6800
18 x 31 - - - - - -
10 000 18 x 35 - - - - - -
L 5±1 L
Ød
F ØD F ØD
5 15 Ød
min. min.
Fig. 2 - Form CA: long leads Fig. 3 - Form CB: cut leads
Table 1
Table 2
1.0 0.6
1 0.4
0.9 Curve 1: 63 V
Curve 2: 50 V
Curve 1: 63 V 0.2 Curve 3: 35 V
2
Curve 2: 10 V Curve 4: 25 V
Curve 5: 10 V
0.8 0
- 60 - 40 - 20 0 20 40 60 80 100 120 10 102 103 104 105
Tamb (°C) f (Hz)
C0 = Typical capacitance at 20 °C, 100 Hz C0 = Typical capacitance at 20 °C, 100 Hz Tamb = 20 °C
Fig. 5 - Typical multiplier of capacitance as a function Fig. 6 - Typical multiplier of capacitance as a function
of ambient temperature of frequency
20 2.0
ESR ESR 1
ESR0 ESR0 Curve 1: 63 V
Curve 2: 10 V
10 1.6
2
1.2
0.8
2
1
0.4
1
0
- 60 - 40 - 20 0 20 40 60 80 100 120 10 102 103 104 105
Tamb (°C) f (Hz)
ESR0 = Typical ESR at 20 °C, 100 Hz ESR0 = Typical ESR at 20 °C, 100 Hz Tamb = 20 °C
Fig. 7 - Typical multiplier of ESR as a function Fig. 8 - Typical multiplier of ESR as a function of frequency
of ambient temperature
UR = 10 V and 16 V
Curve 1: 470 µF, 16 V; Ø 10 x 16 mm
Curve 1: 10 V Curve 2: 680 µF, 10 V; Ø 10 x 16 mm
Curve 2: 50 V Curve 3: 1000 µF, 10 V; Ø 10 x 20 mm
Curve 3: 63 V Curve 4: 2200 µF, 10 V; Ø 12.5 x 25 mm
Curve 5: 4700 µF, 16 V; Ø 16 x 35 mm
Curve 6: 10 000 µF, 10 V; Ø 18 x 35 mm
Fig. 9 - Typical multiplier of impedance as a function Fig. 10 - Typical impedance as a function of frequency
of ambient temperature
UR = 25 V and 35 V UR = 50 V
Curve 1: 220 µF, 25 V; Ø 10 x 12 mm Curve 1: 100 µF, 50 V; Ø 10 x 12 mm
Curve 2: 220 µF, 35 V; Ø 10 x 16 mm Curve 2: 470 µF, 50 V; Ø 12.5 x 25 mm
Curve 3: 330 µF, 35 V; Ø 10 x 20 mm Curve 3: 680 µF, 50 V; Ø 16 x 20 mm
Curve 4: 470 µF, 25 V; Ø 10 x 20 mm Curve 4: 1000 µF, 50 V; Ø 16 x 31 mm
Curve 5: 470 µF, 35 V; Ø 12.5 x 20 mm Curve 5: 2200 µF, 50 V; Ø 18 x 35 mm
Curve 6: 1000 µF, 25 V; Ø 12.5 x 25 mm
Curve 7: 1200 µF, 35 V; Ø 16 x 25 mm
Curve 8: 2200 µF, 35 V; Ø 16 x 35 mm
Curve 9: 3300 µF, 25 V; Ø 16 x 35 mm
Tamb = 20 °C Tamb = 20 °C
Fig. 11 - Typical impedance as a function of frequency Fig. 12 - Typical impedance as a function of frequency
UR = 63 V
Curve 1: 47 µF, 63 V; Ø 10 x 12 mm
Curve 2: 68 µF, 63 V; Ø 10 x 16 mm
Curve 3: 100 µF, 63 V; Ø 10 x 20 mm
Curve 4: 220 µF, 63 V; Ø 12.5 x 20 mm
Curve 5: 270 µF, 63 V; Ø 12.5 x 25 mm
Curve 6: 470 µF, 63 V; Ø 16 x 25 mm
Curve 7: 680 µF, 63 V; Ø 16 x 31 mm
Tamb = 20 °C
Table 3
IA 3.7
IR 3.6
3.5
3.4
3.3
3.2
3.1
3.0
2.8
Lifetime multiplier
2.6
1.
2.4
0
1.
5
2.2
2.
0
3. 0
2.0
0
4.
6. .0
1.8
0
8
IA = Actual ripple current at 100 Hz 1.6
12
20
IR = Rated ripple current at 100 Hz, 105 °C 1.4
30
(1)
Useful life at 105 °C and IR applied; 1.2
(1)
see Table 3 1.0 60
10 0
0.8
15 0
0
20
0.5
0.0
40 50 60 70 80 90 100 110
Tamb (°C)
Fig. 14 - Multiplier of useful life as a function of ambient temperature and ripple current load
Table 4
Table 5
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please
contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that
all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU.
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as Halogen-Free follow Halogen-Free
requirements as per JEDEC JS709A standards. Please note that some Vishay documentation may still make reference
to the IEC 61249-2-21 definition. We confirm that all the products identified as being compliant to IEC 61249-2-21
conform to JEDEC JS709A standards.