LG Water Cooled Centrifugal Chiller

1/2

Job Information
Job Name Victoria Square Mall Software Version CCMS Global 2.1.0.13(231207)

Date 15-Dec-2023 Unit Tag

Engineer icebergselection3 Power Supply (Ph/V/Hz) 3Ph / 400 V / 50 Hz

Unit Information
Model Number MCWFHBM

Pressure Vessel Code Standard(GB)

Refrigerant Type R-134a Refrigerant Charge (kg) 610

No. of Compressor 1 No. of Stage 2

No. of Circuit 1 Model Type ECE8.A21D6X

Starter Type VSD Power Supply (Ph/V/Hz) 3Ph / 400 V / 50 Hz

Shipping Weight (Kg) 8200 Operation Weight (kg) 9300

Motor Cooling Refrigerant Oil Charge (liter) 40

Oil Pump (Ph/V/Hz) 3 Ph / 400V / 50 Hz

Unit Performance
Cooling Capacity (kW) 1407 Cooling Capacity (RT) 400.0

Heat Rejection (kW) 1673 Input Power(kW) 266.1

Full Load Efficiency (kW/Ton) 0.6654 Full Load COP(W/W) 5.284

NPLV.SI (kW/Ton) 0.3772 NPLV.SI (W/W) 9.320

Evaporator
Entering Temperature (deg C) 12.23 Leaving Temperature (deg C) 6.67

Fluid Type Water Fouling Factor (m2 C/kW) 0.0881

Rated Flow Rate (m3/hr) 217.1 Min. Flow Rate (m3/hr) 204.4

Water Box Type Head(Rectangle) Shell Diameter (mm) 889

Maximum Fluid Pressure 10kg/cm2(150 psig) Pressure Drop (kPa) 34.4

Number of Pass 2

Tube Type Enhanced Tube Length (mm) 3004

Tube Material Cu Tube Out-Diameter (mm) 19.05

Nozzle Type ANSI Flange Nozzle Connection Size (mm) 200

Nozzle Inlet Direction Motor End Nozzle Outlet Direction Motor End

Condenser
Entering Temperature (deg C) 32.20 Leaving Temperature (deg C) 37.80

Fluid Type Water Fouling Factor (m2 C/kW) 0.176

Rated Flow Rate (m3/hr) 258.9 Min. Flow Rate (m3/hr) 198.0

Water Box Type Head(Rectangle) Shell Diameter (mm) 762

Maximum Fluid Pressure 10kg/cm2(150 psig) Pressure Drop (kPa) 48.6

Number of Pass 2

Tube Type Enhanced Tube Length (mm) 3004

Tube Material Cu Tube Out-Diameter (mm) 19.05

Nozzle Type ANSI Flange Nozzle Connection Size (mm) 200

Nozzle Inlet Direction Motor End Nozzle Outlet Direction Motor End
LG Water Cooled Centrifugal Chiller
2/2

Full Load Performance Summary (AHRI Rated 551/591)


Capacity (kW) Input Power (kW) Heat Rejection Efficiency (kW/RT) COP (W/W) NPLV.SI (kW/RT) NPLV.SI (W/W)
(kW)
1407 266.1 1673 0.6654 5.284 0.3772 9.320

UNIT PHYSICAL DATA


Length (mm) Width (mm) Height (mm) Shipping Weight (kg) Operation Weight (kg)

3505 2160 2280 8200 9300

UNIT ELECTRICAL DATA


Min. Circuit Max. Overcurrent
Voltage (V) Phase Frequency RLA (A) FLA (A)
Ampacity Protection
400 3 50 421 537 526 947
Protection Grade
Communication (Type) Control Power(kVA) MCCB(A)
(Control Panel)
BACnet IP41 10 630

Starter
Type Mount Type Harmonic
VSD Unit Mounted TDDi < 30%

Part Load Performance Detail (AHRI Rated 551/591)

Load Capacity Input Power EEFT ELFT EEFR EFPD CEFT CLFT CEFR CFPD Efficiency COP
(%) (kW) (kW) (deg C) (deg C) (m3/hr) (kPa) (deg C) (deg C) (m3/hr) (kPa) (kW/RT) (W/W)
100 1407 266.1 12.23 6.67 217.1 34.4 32.20 37.80 258.9 48.7 0.6654 5.284
75 1055 142.3 10.84 6.67 217.1 34.4 25.60 29.71 258.9 48.9 0.4743 7.414
50 703.4 63.29 9.45 6.67 217.1 34.4 19.00 21.73 258.9 49.0 0.3165 11.11
25 351.7 36.57 8.06 6.67 217.1 34.4 19.00 20.37 258.9 49.1 0.3656 9.616

##ImageAHRI ● Certified in accordance with the AHRI Water-Cooled Water-Chilling and Heat Pump