PLOT DETAILS
1 SURVEY NO 733/10B1
AREA TYPE
(Continuous/Economically
12 Weaker Section/Others) OTHERS 13 DEMOLITION AREA in m² 0
OSR SURRENDER/
14 OSR APPLICABLE NO 15 BUYBACK/ RETAIN
Queries
1. BLK_1_FLR_1_STAIR_1_FLIGHT_2 Dimension should be within Flight Layer.
2. Ventilation not defined in block 1,Floor 1,Room 3
3. Room polyline not defined in block 1,Floor 1,Room 3
Overall Summary
Total Area
Built Up Area in m² Carpet Area in m² Covered Area in m² FSI Area in m² Non FSI Area in m²
125.31 0.00 73.33 117.31 8.00
1.No. of Blocks
Description Provided Status
Total Number Of Blocks 1 Verified
2.FSI
As per TNCDBR Occupancy Area Type Road Width Required Provided Status
Part VI Pt.35 / pt.36/ Residential OTHERS 6.10 <= 2 0.957 Verified
pt.37/ pt.38/ pt.39
3.Floor Units
Block Floor Unit Number Unit Area
Block 1 Floor 0 1 66.46 Sq.m
Block 1 Floor 1 1 50.85 Sq.m
4.Parking
As per TNCDBR Description Required Provided Status
Annexure iv - part I-13,17,b,part Two wheeler parking dimension 1 M x 1.8 M Out of 2 parking 0 parking Verified
II-A,C violated dimension.
Annexure iv - part I-13,17,b,part Car Parking 0 0 Verified
II-A,C
Annexure iv - part I-13,17,b,part Two Wheeler Parking 2 2 Verified
II-A,C
5.Septic Tank/drainage
As per TNCDBR Description Status
Part VII , 54-3(b) Septic Tank/drainage Provided Verified
6.Parapet
As per TNCDBR Description Required Provided Status
7.Solar
As per TNCDBR Description Required Provided Status
Part VI 44(2) Solar Assisted Water Heating / Defined in the plan. Verified
Lighting system
9.Height of Building
As per TNCDBR Description Required Provided Status
Part VI Pt.35 / pt.36/ pt.37/ pt.38/ Height of Building for Block 1 12m / G+2 or Stilt +3 / up to 16 6.70m / 2 Floors / 2 Dwelling Verified
pt.39 Dwelling Units units
12.North Direction
As per TNCDBR Description Provided Status
part ii - 8 -iii-(l) North Direction North directions provided Verified
13.Location Plan
As per TNCDBR Description Provided Status
part ii - 8 -i Location Plan Location plans provided Verified
14.Toilet Ventilation
As per TNCDBR Description Required Provided Status
part vii-52(16a) Toilet Ventilation Min 0.5 Sq.m 0.71 Sq.m Verified
15.Road Width
As per TNCDBR Description Occupancy Required Provided Status
Part VI Road Width Individual residence >=3m 6.10m Verified
1.Setback
As per TNCDBR Setback Occupancy Level Field Verified Required Provided Status
Part VI, Pt.35 / Front Individual 0 Minimum distance 1.5 1.50 Verified
pt.36/ pt.37/ pt.38/ residence
pt.39
Part VI, Pt.35 / Side Setback 1 Individual 0 Minimum distance 1 1.0 Verified
pt.36/ pt.37/ pt.38/ residence
pt.39
Part VI, Pt.35 / Side Setback 2 Individual 0 Minimum distance 1 2.2 Verified
pt.36/ pt.37/ pt.38/ residence
pt.39
Part VII , 52(17) floor 1 Minimum width for general 0.75 1.03 Verified
stair 1 mid landing
Part VII , 52(17) floor 0 Minimum tread for general 0.25 0.32 Verified
stair 1 flight 2
Part VII , 52(17) floor 1 Minimum tread for general 0.25 0.32 Verified
stair 1 flight 1
Part VII , 52(17) floor 1 Minimum tread for general 0.25 0.32 Verified
stair 1 flight 2
Part VII , 52(17) floor 0 Minimum width for general 0.75 0.91 Verified
stair 1 flight 2
Part VII , 52(17) floor 1 Minimum width for general 0.75 0.91 Verified
stair 1 flight 2
6.Kitchen
As per TNCDBR Description Floor Required Provided Status
part vii-pt52-6 Minimum height of kitchen floor 0 2.75m 3.00m Verified
7.Kitchen Ventilation
As per TNCDBR Description Required Provided Status
part vii-52(16a) Light and Ventilation Minimum 1/8th of the floor area Ventilation area 1.68 of Kitchen Verified
Area 9.51 at floor 0
part vii-52(16a) Light and Ventilation Minimum 1/8th of the floor area Ventilation area 1.69 of Kitchen Verified
Area 7.18 at floor 1
8.Plinth
As per TNCDBR Description Required Provided Status
part vii-pt52-1 Minimum plinth height >= 0.45m 0.45m Verified
9.Portico
As per TNCDBR Description Required Provided Status
PORTICO DEDUCTION AREA Portico 1 deduction area - 0 Sq.Mtr. Verified
10.Room
As per TNCDBR Description Floor Required Provided Status
part vii-pt52-5,6,9,10 Minimum height of room floor 0 2.75m 3.0m Verified
12.Stair Headroom
As per TNCDBR Description Required Provided Status
part vii-pt52-17(d) Minimum clear of stair head-room 2.2 2.35 Verified
part vii-pt52-17(d) Minimum Area of head-room >0 Sq.m 8.00 Sq.m Verified
13.Ventilation
As per TNCDBR Description Required Provided Status
part vii-52(16a) Light and Ventilation Minimum 1/8th of the floor area Ventilation area 3.65 of Room Verified
Area 18.55 at floor 1
This report is generated based on the Applicant Declaration and a provided drawing. The drawing has been verified with TNCDBR
rules and final decision on approval will be taken by Department officials. Completion Certificate will not be issued if any deviation
from the submitted drawing more than tolerance Limits.