2024 Oy
2024 Oy
2024 Oy
PLOT DETAILS
1 SURVEY NO 271/A1A1A1
AREA TYPE
(Continuous/Economically
12 Weaker Section/Others) OTHERS 13 DEMOLITION AREA in m² 0
OSR SURRENDER/
14 OSR APPLICABLE NO 15 BUYBACK/ RETAIN
Queries
1. Room height is not defined in layer BLK_1_FLR_0_REGULAR_ROOM
Overall Summary
Total Area
Built Up Area in m² Carpet Area in m² Covered Area in m² FSI Area in m² Non FSI Area in m²
31.68 0.00 0.00 31.68 0.00
0 Shops/Shopping
Centres/Departmental 31.68 0 31.68 0 0
Stores/Super Markets
1.No. of Blocks
Description Provided Status
Total Number Of Blocks 1 Verified
2.FSI
As per TNCDBR Occupancy Area Type Road Width Required Provided Status
Part VI Pt.35 / pt.36/ Commercial OTHERS 14.08 <= 2 0.435 Verified
pt.37/ pt.38/ pt.39
3.Parking
As per TNCDBR Description Required Provided Status
Annexure iv - part I-13,17,b,part Two wheeler parking dimension 1 M x 1.8 M Out of 4 parking 0 parking Verified
II-A,C violated dimension.
Annexure iv - part I-13,17,b,part Car Parking 0 0 Verified
II-A,C
Annexure iv - part I-13,17,b,part Two Wheeler Parking 0 4 Verified
II-A,C
5.Parapet
As per TNCDBR Description Required Provided Status
Part VII , 52(13) Parapet Height >= 1.2 and height <= 1.5 Height >= 1.21 and height <= Verified
1.21
6.Solar
As per TNCDBR Description Required Provided Status
Part VI 44(2) Solar Assisted Water Heating / Defined in the plan. Verified
Lighting system
7.Height of Building
As per TNCDBR Description Required Provided Status
10.North Direction
As per TNCDBR Description Provided Status
part ii - 8 -iii-(l) North Direction North directions provided Verified
11.Location Plan
As per TNCDBR Description Provided Status
part ii - 8 -i Location Plan Location plans provided Verified
12.Toilet Ventilation
As per TNCDBR Description Required Provided Status
part vii-52(16a) Toilet Ventilation Min 0.5 Sq.m 0.58 Sq.m Verified
13.Road Width
As per TNCDBR Description Occupancy Required Provided Status
Part VI Road Width Shops/Shopping >=3m 14.08m Verified
Centres/Departmental
Stores/Super Markets
1.Setback
As per TNCDBR Setback Occupancy Level Field Verified Required Provided Status
Part VI, Pt.35 / Front Shops/Shopping 0 Minimum distance 3 3.00 Verified
pt.36/ pt.37/ pt.38/ Centres/Departme
pt.39 ntal Stores/Super
Markets
Part VI, Pt.35 / Side Setback 1 Shops/Shopping 0 Minimum distance 1 1.01 Verified
pt.36/ pt.37/ pt.38/ Centres/Departme
pt.39 ntal Stores/Super
Markets
Part VI, Pt.35 / Side Setback 2 Shops/Shopping 0 Minimum distance 1 1.0 Verified
pt.36/ pt.37/ pt.38/ Centres/Departme
pt.39 ntal Stores/Super
Markets
Part VII , 52(17) floor 0 Minimum tread for general 0.3 0.40 Verified
stair 1 flight 2
Part VII , 52(17) floor 0 Minimum width for general 1.5 1.50 Verified
stair 1 flight 2
6.Plinth
As per TNCDBR Description Required Provided Status
part vii-pt52-1 Minimum plinth height >= 0.45m 0.8m Verified
7.Sanitation
As per TNCDBR Description Required Provided Status
Annexure – X Male Water Closet one for every 1 1 Verified
25 persons or part thereof,
exceeding 15 (including
employees and customers).
This report is generated based on the Applicant Declaration and a provided drawing. The drawing has been verified with TNCDBR
rules and final decision on approval will be taken by Department officials. Completion Certificate will not be issued if any deviation
from the submitted drawing more than tolerance Limits.