Khordha Municipality: Automated Building Permit Approval System
Khordha Municipality: Automated Building Permit Approval System
Khordha Municipality: Automated Building Permit Approval System
PLOT DETAILS
Declarations in Drawings
Is the plot part of the layout approved by the authority or
developed/allotted by the government or statutory bodies or is this
1 a final plot in town planning schemes or development schemes ? YES
Does the Project require NOC from AAI as per the Colour Coded
2 Zone Maps ? NO
Overall Summary
3.Coverage in Percentage
Description Permissible Provided Status
Coverage NA 0.00 Accepted
5.FAR
Base Far Max Permissible Provided Status
2.00 3.00 2.68 Accepted
Declaration by Architect Per acre benchmark value of land needed if 126500000 Verify
project is having purchasable FAR
component
7.Helipad Provision
9.Means of access
Description Required Provided Status
Minimum access width 6 9.15 Verify
10.No of Floors
Description Block Provided
Floors Info 1 G+2
11.North Direction
Description Provided Status
North Direction North directions provided Accepted
16.Parking Provision
Description Required Provided Status
Staff Parking NA 0 Accepted
Visitor Parking NA 0.00 Accepted
Two Wheeler Parking NA 0 Accepted
Bicycle Parking NA 0 Accepted
EWS/LIG Parking NA 0 Accepted
MIG Parking NA 0 Accepted
Ev charging point NA 0 Accepted
17.Parking Type
Description Required Provided Status
Total Parking NA 38.30 Accepted
Open Parking NA 38.30 Accepted
Basement Parking NA 0.00 Accepted
Stilt Parking NA 0 Accepted
Roof top parking NA 0 Accepted
Stack parking NA 0 Accepted
19.Plantation
Description Required Provided Status
Plantation Area NA 0% Accepted
22.Recharging pits
Description Required Provided Status
Recharging pits Count OPTIONAL Not Defined in the plan Accepted
Dimension of recharging pits OPTIONAL 0.00 cubic meters Accepted
23.Solar PV System
Description Required Provided Status
Total connected load of the proposed NA 0 Accepted
project in W
24.Special Parking
Description Required Provided Status
Special Parking count NA 0 Accepted
Special Parking Area NA 0.00 Accepted
Special Parking width NA 0 Accepted
4.Doorways
Description Floor Required Provided Status
Genral Doorways Count 0 1 1 Accepted
Genral Doorways Width 0 1 1.22 Accepted
Genral Doorways Count 1 1 0 Not Accepted
7.Height of Building
Description Up To Provided Status
Height of Building for Block 1 NA 9.00 Accepted
9.Sanitation
Description Required Provided Status
Water Closet Common - Count 1 7 Accepted
Bath Room Common - Count 1 6 Accepted
10.Setback
Description Permissible Provided Status
Min Front setback 1.5 0.00 Not Accepted
Total cumulative Front and rear Setback 2.5 0.00 Not Accepted
12.Setback polygon
Description Status
All setback polygons are drawn correctly (Each setback Polygon shall be touching the corners of Building Footprint and Plot Area) Verify
Error Summary
S.No Error Description
1 BLDG_FOOT_PRINT is not closed
2 Coverage Area for block 1 not Provided