A2D240-AA02-02 AC axial fan

sickle-shaped blades (S series), single-intake

ebm-papst Mulfingen GmbH & Co. KG


Bachmühle 2 · D-74673 Mulfingen
Phone +49 7938 81-0
Fax +49 7938 81-110
info1@de.ebmpapst.com
www.ebmpapst.com
Limited partnership · Headquarters Mulfingen
Amtsgericht (court of registration) Stuttgart · HRA 590344

General partner Elektrobau Mulfingen GmbH · Headquarters Mulfingen


Amtsgericht (court of registration) Stuttgart · HRB 590142

Nominal data

Type A2D240-AA02-02
Motor M2D068-CF

Phase 3~ 3~ 3~ 3~
Nominal voltage VAC 230 230 400 400
Wiring Δ Δ Y Y
Frequency Hz 50 60 50 60

Method of obtaining data fa fa fa fa


Valid for approval/standard CE CE CE CE
Speed (rpm) min-1 2550 2700 2550 2700
Power consumption W 95 125 95 125
Current draw A 0.31 0.35 0.18 0.20
Min. ambient temperature °C -25 -25 -25 -25
Max. ambient temperature °C 75 70 75 70
Starting current A 0.88 0.87 0.51 0.5
ml = Max. load · me = Max. efficiency · fa = Free air · cs = Customer specification · ce = Customer equipment
Subject to change

Item no. 14661-5-9980 · ENU · Change 89188 · Approved 2016-04-28 · Page 1 / 6

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
A2D240-AA02-02 AC axial fan
sickle-shaped blades (S series), single-intake

Technical description

Weight 1.65 kg
Fan size 240 mm
Rotor surface Painted black
Blade material Sheet steel, painted black
Number of blades 5
Airflow direction "A"
Direction of rotation Clockwise, viewed toward rotor
Degree of protection IP44; installation- and position-dependent
Insulation class "B"
Moisture (F) / Environmental (H) F5
protection class
Max. permitted ambient temp. + 80 °C
for motor (transport/storage)
Min. permitted ambient temp. for - 40 °C
motor (transport/storage)
Installation position Any
Condensation drainage holes None
Mode S1
Motor bearing Ball bearing
Touch current according to IEC < 0.75 mA
60990 (measuring circuit Fig. 4,
TN system)
With cable Lateral
Protection class I (with customer connection of protective earth)
Conformity with standards EN 60335-1, motor does not have factory-installed overheating protection; CE

Item no. 14661-5-9980 · ENU · Change 89188 · Approved 2016-04-28 · Page 2 / 6

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
A2D240-AA02-02 AC axial fan
sickle-shaped blades (S series), single-intake

Product drawing

1 Direction of air flow "A"


2 Max. clearance for screw 5 mm
3 Cable PVC 7G 0.5 mm², 7x crimped splices

Item no. 14661-5-9980 · ENU · Change 89188 · Approved 2016-04-28 · Page 3 / 6

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
A2D240-AA02-02 AC axial fan
sickle-shaped blades (S series), single-intake

Connection diagram

Change of rotation direction by reversing two phases

Three-phase motor Δ Delta connection Y Star connection


L1 = U1 = black L2 = V1 = blue L3 = W1 = brown
U2 green V2 white W2 yellow
PE green/yellow

Item no. 14661-5-9980 · ENU · Change 89188 · Approved 2016-04-28 · Page 4 / 6

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
A2D240-AA02-02 AC axial fan
sickle-shaped blades (S series), single-intake

Curves: Air performance 50 Hz

pfs @ rho=1,2 kg/m³


qv [CFM]
00 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750

300 1,2
1,15
280 Measurement: LU-59198-1
1,1
1,05 Air performance measured according to ISO
260 5801 installation category A. For detailed
1 information on the measurement setup,
240 contact ebm-papst. Intake sound level:
0,95 Sound power level according to ISO 13347 /
0,9 sound pressure level measured at 1 m
220 distance from fan axis. The values given are
0,85 valid under the specified measuring
conditions and may vary due to conditions of
200 0,8 installation. For deviations from the standard
0,75 configuration, the parameters have to be
180 checked on the installed unit.
0,7

pfs [InH2O]
pfs [Pa]

160 0,65
0,6
140 0,55
0,5
120 4
0,45
100 0,4
3 0,35
80
0,3
60 0,25
2 0,2
40 0,15
0,1
20
0,05
1
0
0 200 400 600 800 1000 1200
qv [m³/h]

Measured values
U f n Pe I qv pfs qv pfs
V Hz min-1 W A m3/h Pa CFM inH2O
1 400 50 2550 95 0.18 1220 0 715 0.00
2 400 50 2515 97 0.18 1130 40 665 0.16
3 400 50 2500 100 0.18 1010 80 595 0.32
4 400 50 2490 101 0.18 870 110 510 0.44
U = Power supply · f = Frequency · n = Speed (rpm) · Pe = Power consumption · I = Current draw · qv = Air flow · pfs = Pressure increase

Item no. 14661-5-9980 · ENU · Change 89188 · Approved 2016-04-28 · Page 5 / 6

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
A2D240-AA02-02 AC axial fan
sickle-shaped blades (S series), single-intake

Curves: Air performance 60 Hz

pfs @ rho=1,2 kg/m³


qv [CFM]
00 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800
300 1,2
1,15
280
1,1 Measurement: LU-59199-1
260 1,05
Air performance measured according to ISO
1 5801 installation category A. For detailed
240 information on the measurement setup,
0,95 contact ebm-papst. Intake sound level:
0,9 Sound power level according to ISO 13347 /
220 sound pressure level measured at 1 m
0,85 distance from fan axis. The values given are
valid under the specified measuring
200 0,8 conditions and may vary due to conditions of
installation. For deviations from the standard
0,75 configuration, the parameters have to be
180
0,7 checked on the installed unit.

pfs [InH2O]
160 0,65
pfs [Pa]

0,6
140 0,55
4 0,5
120
0,45
100 0,4
3 0,35
80
0,3
60 0,25

2 0,2
40 0,15
0,1
20
0,05
1
0
0 200 400 600 800 1000 1200 1400
qv [m³/h]

Measured values
U f n Pe I qv pfs qv pfs
V Hz min-1 W A m3/h Pa CFM inH2O
1 400 60 2700 125 0.20 1305 0 770 0.00
2 400 60 2675 129 0.21 1210 40 710 0.16
3 400 60 2640 133 0.21 1090 80 645 0.32
4 400 60 2620 135 0.21 935 120 550 0.48
U = Power supply · f = Frequency · n = Speed (rpm) · Pe = Power consumption · I = Current draw · qv = Air flow · pfs = Pressure increase

Item no. 14661-5-9980 · ENU · Change 89188 · Approved 2016-04-28 · Page 6 / 6

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com

You might also like