Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Ebm Papst Data Sheet US R2E180CB2817 KM89188

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

R2E180-CB28-17 AC centrifugal fan

backward-curved, single-intake

ebm-papst Mulfingen GmbH & Co. KG


Bachmühle 2 · D-74673 Mulfingen
Phone +49 7938 81-0
Fax +49 7938 81-110
info1@de.ebmpapst.com
www.ebmpapst.com
Limited partnership · Headquarters Mulfingen
Amtsgericht (court of registration) Stuttgart · HRA 590344

General partner Elektrobau Mulfingen GmbH · Headquarters Mulfingen


Amtsgericht (court of registration) Stuttgart · HRB 590142

Nominal data

Type R2E180-CB28-17
Motor M2E068-BF

Phase 1~ 1~
Nominal voltage VAC 230 230
Frequency Hz 50 60

Method of obtaining data fa fa


Valid for approval/standard CE CE
Speed (rpm) min-1 2550 2800
Power consumption W 60 75
Current draw A 0.28 0.33
Capacitor µF 1.5 1.5
Capacitor voltage VDB 450 450
Capacitor standard S0 (CE) S0 (CE)
Min. back pressure Pa 0 0
Min. back pressure in. wg 0 0
Min. ambient temperature °C -25 -25
Max. ambient temperature °C 40 60
Starting current A 0.45 0.45
ml = Max. load · me = Max. efficiency · fa = Free air · cs = Customer specification · ce = Customer equipment
Subject to change

Item no. 12279-5-9980 · ENU · Change 89188 · Approved 2016-08-25 · Page 1 / 5

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
R2E180-CB28-17 AC centrifugal fan
backward-curved, single-intake

Technical description

Weight 1.36 kg
Size 180 mm
Motor size 68
Rotor surface Painted black
Impeller material PA plastic
Number of blades 16
Direction of rotation Clockwise, viewed toward rotor
Degree of protection IP44; installation- and position-dependent as per EN 60034-5
Insulation class "B"
Moisture (F) / Environmental (H) H1+
protection class
Max. permitted ambient temp. + 80 °C
for motor (transport/storage)
Min. permitted ambient temp. for - 40 °C
motor (transport/storage)
Installation position Shaft horizontal or rotor on bottom; rotor on top on request
Condensation drainage holes On rotor side
Mode S1
Motor bearing Ball bearing
Touch current according to IEC < 0.75 mA
60990 (measuring circuit Fig. 4,
TN system)
Motor protection Thermal overload protector (TOP) internally connected
With cable Variable
Protection class I (with customer connection of protective earth)
Conformity with standards EN 60335-1; CE

Item no. 12279-5-9980 · ENU · Change 89188 · Approved 2016-08-25 · Page 2 / 5

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
R2E180-CB28-17 AC centrifugal fan
backward-curved, single-intake

Product drawing

1 Accessory part: inlet ring 09576-2-4013, not included in scope of delivery


2 Max. clearance for screw 5 mm
3 Cable silicone 4G 0.5 mm², 4x crimped splices

Connection diagram

U1 blue Z brown U2 black


PE green/yellow

Item no. 12279-5-9980 · ENU · Change 89188 · Approved 2016-08-25 · Page 3 / 5

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
R2E180-CB28-17 AC centrifugal fan
backward-curved, single-intake

Curves: Air performance 50 Hz


Druck p f s[Pa] für Rho=1,2kg/m^3

qv[cfm]
0 50 100 150 200 250
310
300 1,2
290
1,15
280
1,1
270 Measurement: LU-57242-1
260 1,05

250 1
Air performance measured according to ISO
5801 installation category A. For detailed
240 information on the measurement setup,
0,95
230 contact ebm-papst. Intake sound level:
4 0,9 Sound power level according to ISO 13347 /
220 sound pressure level measured at 1 m
210 0,85 distance from fan axis. The values given are
200
valid under the specified measuring
0,8
conditions and may vary due to conditions of
190
0,75 installation. For deviations from the standard
180 configuration, the parameters have to be
3 0,7 checked on the installed unit.

p fs_E [IN H2O]


170
p f s[Pa]

160 0,65

150 0,6
140
0,55
130
0,5
120
110 0,45
2
100 0,4
90 0,35
80
0,3
70
60 0,25

50 0,2
40 0,15
30
0,1
20
p

10 0,05
fs

1
[Pa

0 0
]

0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 420 440 460 480
qv[m^3/h]

Measured values
U f n Pe I qV pfs qV pfs
V Hz min-1 W A m3/h Pa cfm in. wg
1 230 50 2550 60 0.28 440 0 260 0.00
2 230 50 2485 62 0.28 335 100 195 0.40
3 230 50 2535 60 0.27 245 170 145 0.68
4 230 50 2630 55 0.26 130 220 75 0.88
U = Voltage · f = Frequency · n = Speed (rpm) · Pe = Power consumption · I = Current draw · qV = Air flow · pfs = Pressure increase

Item no. 12279-5-9980 · ENU · Change 89188 · Approved 2016-08-25 · Page 4 / 5

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
R2E180-CB28-17 AC centrifugal fan
backward-curved, single-intake

Curves: Air performance 60 Hz


Druck p f s[Pa] für Rho=1,2kg/m^3

qv[cfm]
0 50 100 150 200 250 300

400 1,6
1,55
380
1,5
360 1,45
Measurement: LU-57243-1
1,4
340
1,35 Air performance measured according to ISO
320
1,3 5801 installation category A. For detailed
1,25 information on the measurement setup,
contact ebm-papst. Intake sound level:
300 1,2 Sound power level according to ISO 13347 /
1,15 sound pressure level measured at 1 m
280 distance from fan axis. The values given are
1,1
4 valid under the specified measuring
260 1,05 conditions and may vary due to conditions of
1 installation. For deviations from the standard
240 configuration, the parameters have to be
0,95
checked on the installed unit.

p fs_E [IN H2O]


0,9
220
p f s[Pa]

0,85
200 0,8
3 0,75
180
0,7
160 0,65
0,6
140 0,55
0,5
120
0,45
2
100 0,4
0,35
80
0,3

60 0,25
0,2
40 0,15
0,1
20
p

0,05
fs

1
[Pa

0 0
]

0 50 100 150 200 250 300 350 400 450 500


qv[m^3/h]

Measured values
U f n Pe I qV pfs qV pfs
V Hz min-1 W A m3/h Pa cfm in. wg
1 230 60 2800 75 0.33 475 0 280 0.00
2 230 60 2670 79 0.34 375 100 220 0.40
3 230 60 2725 77 0.33 295 180 175 0.72
4 230 60 2895 71 0.31 170 260 100 1.04
U = Voltage · f = Frequency · n = Speed (rpm) · Pe = Power consumption · I = Current draw · qV = Air flow · pfs = Pressure increase

Item no. 12279-5-9980 · ENU · Change 89188 · Approved 2016-08-25 · Page 5 / 5

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com