AC Axial Fan: Sickle-Shaped Blades (S Series) A2D300-AP02-02

Download as pdf or txt
Download as pdf or txt
Download as pdf or txt
You are on page 1/ 6

A2D300-AP02-02 AC axial fan

sickle-shaped blades (S series)

ebm-papst Mulfingen GmbH & Co. KG


Bachmühle 2 · D-74673 Mulfingen
Phone +49 7938 81-0
Fax +49 7938 81-110
info1@de.ebmpapst.com
www.ebmpapst.com
Limited partnership · Headquarters Mulfingen
Amtsgericht (court of registration) Stuttgart · HRA 590344

General partner Elektrobau Mulfingen GmbH · Headquarters Mulfingen


Amtsgericht (court of registration) Stuttgart · HRB 590142

Nominal data

Type A2D300-AP02-02
Motor M2D074-DF

Phase 3~ 3~ 3~ 3~
Nominal voltage VAC 230 230 400 400
Wiring Δ Δ Y Y
Frequency Hz 50 60 50 60

Method of obtaining data fa fa fa fa


Valid for approval/standard CE CE CE CE
Speed (rpm) min-1 2580 2750 2580 2750
Power consumption W 210 300 210 300
Current draw A 0.62 0.84 0.36 0.48
Max. back pressure Pa 200 125 200 125
Max. back pressure in. wg 0.8 0.5 0.8 0.5
Min. ambient temperature °C -25 -25 -25 -25
Max. ambient temperature °C 75 40 75 40
Starting current A 2.0 1.9 1.16 1.1
ml = Max. load · me = Max. efficiency · fa = Free air · cs = Customer specification · ce = Customer equipment
Subject to change

Data according to Commission Regulation (EU) 327/2011


Actual Req. 2015

01 Overall efficiency ηes % 29.9 29.9 09 Power consumption Pe kW 0.25


02 Measurement category A 09 Air flow qv m³/h 2210
03 Efficiency category Static 09 Pressure increase pfs Pa 125
04 Efficiency grade N 40 40 10 Speed (rpm) n min-1 2455
05 Variable speed drive No 11 Specific ratio* 1.00
Data obtained at optimum efficiency level. * Specific ratio = 1 + pfs / 100 000 Pa LU-62732
The ErP data is determined using a motor-impeller combination in a standardized measurement setup.

Item no. 10365-5-9980 · ENU · Change 96928 · Approved 2017-10-26 · Page 1 / 6

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
A2D300-AP02-02 AC axial fan
sickle-shaped blades (S series)

Technical description

Weight 3.1 kg
Fan size 300 mm
Rotor surface Painted black
Blade material Sheet steel, painted black
Number of blades 5
Airflow direction "A"
Direction of rotation Clockwise, viewed toward rotor
Degree of protection IP44; installation- and position-dependent as per EN 60034-5
Insulation class "F"
Moisture (F) / Environmental (H) H1
protection class
Max. permitted ambient temp. + 80 °C
for motor (transport/storage)
Min. permitted ambient temp. for - 40 °C
motor (transport/storage)
Installation position Shaft horizontal or rotor on bottom; rotor on top on request
Condensation drainage holes On rotor side
Mode S1
Motor bearing Ball bearing
Touch current according to IEC < 0.75 mA
60990 (measuring circuit Fig. 4,
TN system)
With cable Variable
Protection class I (with customer connection of protective earth)
Conformity with standards EN 60335-1, motor does not have factory-installed overheating protection
Approval CCC; EAC

Item no. 10365-5-9980 · ENU · Change 96928 · Approved 2017-10-26 · Page 2 / 6

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
A2D300-AP02-02 AC axial fan
sickle-shaped blades (S series)

Product drawing

1 Direction of air flow "A"


2 Max. clearance for screw 10 mm
3 Cable PFA AWG20 (green/yellow AWG18), 7x crimped splices

Item no. 10365-5-9980 · ENU · Change 96928 · Approved 2017-10-26 · Page 3 / 6

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
A2D300-AP02-02 AC axial fan
sickle-shaped blades (S series)

Connection diagram

Change of rotation direction by reversing two phases

Three-phase motor Δ Delta connection Y Star connection


L1 = U1 = black L2 = V1 = blue L3 = W1 = brown
U2 green V2 white W2 yellow
PE green/yellow

Item no. 10365-5-9980 · ENU · Change 96928 · Approved 2017-10-26 · Page 4 / 6

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
A2D300-AP02-02 AC axial fan
sickle-shaped blades (S series)

Curves: Air performance 50 Hz


in wg
Pa

160 4 ρ = 1.15 kg/m³ ± 2 %


0.6

Measurement: LU-62732-1

Air performance measured according to ISO


5801 installation category A. For detailed
information on the measurement setup,
contact ebm-papst. Intake sound level:
120 Sound power level according to ISO 13347 /
sound pressure level measured at 1 m
distance from fan axis. The values given are
valid under the specified measuring
3 conditions and may vary due to conditions of
0.4

installation. For deviations from the standard


configuration, the parameters have to be
checked on the installed unit.
80

2
0.2

40

0 400 800 1200 1600


1 cfm
Pfs

qv 500 1000 1500 2000 2500 3000 m³/h

Measured values
Wired U f n Pe I qV pfs qV pfs
V Hz min-1 W A m3/h Pa cfm in. wg
1 Y 400 50 2580 210 0.36 3135 0 1845 0.00
2 Y 400 50 2540 228 0.36 2805 50 1650 0.20
3 Y 400 50 2490 244 0.39 2445 100 1440 0.40
4 Y 400 50 2385 281 0.44 1690 160 995 0.64
Wired = Wiring · U = Power supply · f = Frequency · n = Speed (rpm) · Pe = Power consumption · I = Current draw · qV = Air flow · pfs = Pressure increase

Item no. 10365-5-9980 · ENU · Change 96928 · Approved 2017-10-26 · Page 5 / 6

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
A2D300-AP02-02 AC axial fan
sickle-shaped blades (S series)

Curves: Air performance 60 Hz


in wg
Pa

4 ρ = 1.15 kg/m³ ± 2 %
0.5

120
Measurement: LU-62733-1

Air performance measured according to ISO


5801 installation category A. For detailed
information on the measurement setup,
0.4

contact ebm-papst. Intake sound level:


Sound power level according to ISO 13347 /
sound pressure level measured at 1 m
distance from fan axis. The values given are
valid under the specified measuring
80 3 conditions and may vary due to conditions of
installation. For deviations from the standard
0.3

configuration, the parameters have to be


checked on the installed unit.
0.2

40 2
0.1

0 400 800 1200 1600


1cfm
Pfs

qv 500 1000 1500 2000 2500 3000 m³/h

Measured values
U f n Pe I qV pfs qV pfs
V Hz min-1 W A m3/h Pa cfm in. wg
1 400 60 2750 300 0.48 3350 0 1970 0.00
2 400 60 2685 316 0.48 3060 40 1800 0.16
3 400 60 2625 331 0.50 2765 80 1625 0.32
4 400 60 2540 349 0.53 2345 125 1380 0.50
U = Power supply · f = Frequency · n = Speed (rpm) · Pe = Power consumption · I = Current draw · qV = Air flow · pfs = Pressure increase

Item no. 10365-5-9980 · ENU · Change 96928 · Approved 2017-10-26 · Page 6 / 6

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com