Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

EPC CLT RHU W STR 01an1

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

N

PROPOSED HEALTH
UNIT BUILDING

F
KEY PLAN
E
D

Rev Description DRN CHD. VER. DATE


B DESIGN CONSULTANTS
RSB ARCH PROJECT CONSULTANTS PVT. LT.
No:1,First Floor ,Maskur Building,
Krishnamma Road,Nungambakkam,
Chennai - 600034

EPC AGENCY
RPDPL - YFC (JV)
No : 33/2B1 Rank paradise,
Mullai Nagar ,Suramangalam,
Salem - 636005,
Tamilnadu.

A
AUTHORITY ENGINEER

1 2 3 4 5 6 7 8 AUTHORITY
Southern Railway,
Kozhikode (Calicut) Railway Station,
Kozhikode - 673001, Kerala.

DOCUMENT REVIEW
This document has been reviewed for compiance with
the intent of design documentation and is
A No Objection. Proceed with the Works

Objection. Proceed with the Works Subjected


B to incorporation of Comments as Noted

C Rejected.Resubmit.
NOTES:
Received for Information/More Information
1. ALL DIMENSIONS ARE IN MILLIMETER, UNLESS OTHERWISE SPECIFIED. D required.Not Reviewed
Y 2. DRAWING SHOULD NOT BE SCALED, FOLLOW FIGURED DIMENSIONS.
3. ANY DISCREPANCY IN DRAWING SHALL BE BRING TO NOTICE OF STRUCTURAL THIS REVIEW DOES NOT RELIEVE OR DIMINISH THE CONTRACTOR'S RESPONSIBILITY TO
CONSULTANT BEFORE EXECUTION OF WORK. COMPLETE THE WORKS IN FULL ACCORDANCE WITH THE CONTRACT
4. THIS DRAWING SHOULD BE READ ALONG WITH THE RELEVANT
ARCHITECTURAL DRAWING. AUTHORITY
5. IF THERE IS ANY REVISION IN DRAWING, FURTHER CONSTRUCTION SHALL BE CHIEF ENGINEER DEPUTY CHIEF ENGINEER AXEN
EXECUTED AS PER THE LATEST REVISED DRAWING, ON THE ISSUE OF LATEST
REVISION.
6. GRADE OF CONCRETE SHALL BE M30.GRADE OF STEEL SHALL BE Fe500D
7. CHAIR SHALL BE PROVIDED TO SUPPORT TOP BAR
8. FIXING AND BENDING OF REINFORCEMENT SHALL BE AS PER IS 2502
9. USE CONCRETE VIBRATOR FOR ALL RCC WORKS
SSE
10. USE COVER BLOCK IF CM 1:1
11. CUBE TEST ARE TO BE DONE.THERE SHALL BE ONE SET OF THREE CUBES PER
EVERY 20m3 CEMENT CONCRETE OR PART THERE OF USED AT SITE AND SHALL
BE TESTED ON 7TH/28TH DAYS
12. CLEAR COVER FOR
PILE CAP : 75mm
PILE
COLUMN
: 50mm
: 40mm
EPC
BEAM : 30mm PROJECT ARCHITECT PROJECT DESIGN DIRECTOR LEAD DESIGNER EPC AGENCY:
SLAB : 25mm
13. DEVELOPMENT FOR ALL THE ZONES
FOR 500D GRADE OF STEEL Ld : 46 Ø (COMPRESSION)
RADHAKRISH NEELIATH
SUGAVAN VINOTHKUMAR
Ld : 46 Ø + 10 db (TENSION)
14. DESIGNED FOR SEISMIC LOAD AS PER IS 1893(part I) 2016
NAN SURESH KANNOTH
AN R SHANMUGAVEL
15. CONSIDERED DEAD & LIVE AS PER IS 875-1987(part II) MANEE
Digitally signed by Digitally signed by
X WIND LOAD AS PER IS 875-2015(part III) Digitally signed by Digitally signed by VINOTHKUMAR
RADHAKRISHNAN
16. THE BUILDING IS DESIGNED FOR GROUND+1 ONLY NEELIATH KANNOTH MANEE SUGAVANAN R SHANMUGAVEL
SURESH Date: 2024.02.17 19:08:36
Date: 2024.02.27 12:07:36
Date: 2024.02.17 10:53:09 +05'30' Date: 2024.02.17
+05'30'
+05'30' 09:55:41 +05'30'
LEGENDS:
Ld
TYP
- DEVELOPMENT LENGTH
- TYPICAL
PROPOSED HEALTH UNIT BUILDING
NOTES: C/C
FFL
- CENTER TO CENTER
- FLOOR FINISH LEVEL
1.AS PER IS 2911:1.1:2010 CLAUSE 7.3.3,THE MINIMUM CEMENT FRL - FORMED ROAD LEVEL
P - PILE PILE FOUNDATION LAYOUT & DETAILS
CONTENT SHALL BE 400Kg/m³.HOWEVER ,WITH PROPER MIX DESIGN PC - PILE CAP
AND USE OF PROPER ADMIXTURES THE CEMENT MAY BE REDUCED PROOF CONSULTANTS: DATE 16/02/24 SCALE DWG NO:
BUT IN NO CASE THE CEMENT CONTENT SHALL BE LESS THAN
350Kg/m³. Digitally signed by DRAWN SK PROJ. NO. 000 EPC-CLT-RHU-W-STR-01
2. N VALUE >50 AND BORING METHODOLOGY TO ENSURE AT SITE AS PER IS 2911
RAJARAM RAJARAM SATISH KUMAR THESE DRAWINGS ARE UNDER COPYRIGHT AND ARE THE PROPERTY OF RSB ARCH PROJECT CONSULTANTS.NONE OF THE DRAWING

SATISH KUMAR
AND RELATED DOCUMENTS CAN BE REPRODUCED,COPIED IN WHOLE OR IN PART WITHOUT PRIOR EXPRESSED WRITTEN CONSENT OF
Date: 2024.02.16 19:28:12 RSB ARCH PROJECT CONSULTANTS. THESE DRAWINGS CANNOT BE HANDED OVER TO A THIRD PARTY OR USED FOR ANY
+05'30' PURPOSE,OTHER THAN FOR WHICH IT HAS BEEN LOANED.AFTER FULFILLED THE PURPOSE OF ISSUE THE DRAWINGS SHALL BE
RETURNED TO RSB ARCH PROJECT CONSULTANTS.

You might also like