Wall Type 3

Timber frame wall with 102.5mm Brickwork Outer Leaf


U-Value achieved 0.16 W/m²K
1. Exposed Bricks leaf - reclaim London Stock
2. 50mm clear cavity
3. 50mm Kingspan Kooltherm K112 Framing Board
4. Breathable membrane
5. 12mm OSB Panel
6. 100mm Structural Timber Frame - Refer to
S.Engineer Details
7. 50mm Kingspan Kooltherm K112 Framing Board
8. Vapour Control Layer
9. 12.5mm Gyproc wallboard with nom 2.5mm skim
finish or 12mm plywood and 15mm MDF
decoration board. TBC

Flush Lead detail overlapping Roof Boundary Line


Glaze to provide weather tightness.
Ex. FF Level
(+15.826)
Abutment Glaze roof detail as per manufacture
specification. L Bracket fixed to precast
100x500mm concrete
Neighbor flush lead level
Double Glazed Roof panel with self cleaning surface to manufacture
company specs. Glazing Vision or IQ Glass supplier or similar
approved

Glazed Roof Level


(+15.560)
ToS
(+15.500)

Exposed powder coated steel


beam
Junction detail between roof glaze
and vertical glaze panel to have
aluminum or similar approved
covering section. Colour TBC

Fixed Vertical Double Glaze


Panel to specialist Manufacture
specs. Glazing Vision or IQ
Glass Colour Frame TBC
Neighbor Aluminum side
extension panel. Not affected by
works

Neighbor mechanism for glaze


roof opening. Not affected by
works

Proprietary Cavity closer

Lead dressed from underside


Wall Type 1*
copping to existing neighbor
External cladding lead copping stone
18 WBP Plywood
100mm Timber Stud
50mm clear cavity
60mm Kingspan Kooltherm K8 Cavity Board
Inner Blockwork Leaf Concealed Gutter. Gu01
Lead dressed and overlapping
to form continuity from under
side glass frame to
gutter upstand

Lead to from copping upstand


100 90

Kitchen Unit worktop Top of wall


(+13.980)
Neighbor flush panel.
125
2140

Not affected by works


Kitchen upstand worktop bars
Gu02 Level
(+13.858)
480 206 50 950

Wall Type 1
Existing Wall
Delta Membrane Drainage
50mm clear cavity
60mm Kingspan Kooltherm K8 Cavity Board
Inner Blockwork Leaf
Proposed open shelves to
behind kitchen untis.
Materials TBC

Flat metal bar handrail


1260

Proposed open shelves to


stair side

Exposed powder coated steel


beam
Intersection Detail 01
Stair Step
scale 1:5

Solid portion of floor framing


Glazed portion of Floor

Rev Date Info NOTES:


CBO ARCHITECTS FOR TENDER
Permission is granted to scale from this drawing for
www.cboarchitects.com client Mr Michael Sabbah drawing Intersection Detail 01
A 16.XII.19 Exposed Bricks removed
Local Authority Planning Approval purposes only. +44(0)741106166
Refer to title block for original printed paper size.
salvatore@cboarchitects.com project 14 Britten Street
SW3 3TU London
info@cboarchitects.com

drawn check date 12.09.19 scale 1:5@A1 no. 025.300 rev. A