Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

RCC Slab Design

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 4

Design of Slab

Panel Size : Lx = 1.000 m Grade of Concrete ( fck) = 30 N/mm2


Ly = 1.200 m Grade of Steel ( fy) = 500 N/mm2
Weight of Concrete = 25 kN/m3
Slab thickness = 250 mm

Dead Load
Weight of Slab = 6.3 kN/m2
Wt of floor finish = 0.92 kN/m2
7.17 kN/m2

Live Load
Floor Live Load = 80.00 kN/m2

Loading Intensity : DL = 7.2 kN/m2


LL = 80.0 kN/m2
Total Load (w) = 87.17 kN/m2

Ly / Lx = 1.200 So it is to be designed as a two-way slab

From Table 26 of IS 456 : 2000, (Two Adjacent edges discontinuous)


short span co-efficient ax = -0.06
0.045
long span co-efficient ay = -0.047
0.035

Shorter Direction
Maxm hogging moment = 5.2 kNm/m
Maxm sagging moment = 3.9 kNm/m

Longer Direction
Maxm hogging moment = 4.1 kNm/m
Maxm sagging moment = 3.1 kNm/m

Load Factor = 1.5 , Mu (-) = 8 kNm/m


6 kNm/m
Mu (+) = 6 kNm/m
5 kNm/m
Shorter direction
Reinforcement at top

Overall depth (D) = 250 mm


Clear cover = 25 mm
Dia of bar = 8 mm
Effective depth (d) = 213 mm
Mu/bd2 = 0.17
Grade of concrete = M 30
Grade of reinforcement = Fe 500
pt = 0.040 %
Ast required = 85 mm2
Spacing required = 589 mm
Spacing provided = 150 mm

Reinforcement at bottom

Overall depth (D) = 250 mm


Clear cover = 25 mm
Dia of bar = 8 mm
Effective depth (d) = 213 mm
Mu/bd2 = 0.13
Grade of concrete = M 30
Grade of reinforcement = Fe 500
pt = 0.030 %
Ast required = 64 mm2
Spacing required = 788 mm
Spacing provided = 150 mm

Longer direction
Reinforcement at top

Overall depth (D) = 250 mm


Clear cover = 25 mm
Dia of bar = 10 mm
Effective depth (d) = 210 mm
Mu/bd2 = 0.14
Grade of concrete = M 30
Grade of reinforcement = Fe 500
pt = 0.120 %
Ast required = 252 mm2
Spacing required = 312 mm
Spacing provided = 150 mm
Reinforcement at bottom

Overall depth (D) = 250 mm


Clear cover = 25 mm
Dia of bar = 10 mm
Effective depth (d) = 210 mm
Mu/bd2 = 0.10
Grade of concrete = M 30
Grade of reinforcement = Fe 500
pt = 0.120 %
Ast required = 300 mm2
Spacing required = 262 mm
Spacing provided = 150 mm

Check For Shear

Shear stress = (15.92 X 1000 X 1000) X 1.5 X 0.6

1000 X 1000X 152


( As per Table 13 of IS:456-2000, the shear co-efficient is 0.6
for support next to end support which is maximum)
= 0.31 N/mm2

Maximum percentage of reinforcement provided (pt) = (100 X 1000 X 122 X π)


(4 X 150 X 1000 X 152)
= 0.36 %

Shear strength of concrete (τc) = 0.5 N/mm2 (As per Table-19 of


IS:456-2000)

As per Cl. 40.2.2.1 of IS:456-2000,

k = 1.2 (For overall slab depth of 250mm)

Therefore, Design shear strength for concrete = τc X k


= 0.6 N/mm2 > 0.16 N/mm2

(Hence, OK)

Check For Deflection

Span = 1.000 m

Span by Depth Ratio = 20


Steel stress of service (fs)= 0.58*fy* Area of cross-section of steel required
Area of cross-section of steel provided

= 35.35 N/mm2

Percentage of tension reinforcement= 0.36 %

Modification factor for tension reinforcement (k t)= 2 (Ref. Fig 4 of IS:456-2000)

Percentage of compression reinforcement= 0.36 %

Modification factor for compression reinforcement (k c)= 1.15 (Ref. Fig 5 of IS:456-2000)

(L/d)theo = (L/d)required*kt*kc*kf
= (20 X 2 X 1.095 X 1)
= 46

(L/d)provided= (L/d)act = ( 3090 / 152)


= 4.69 < 46 OK

Hence Ok for Deflection Check

Output Data

Slab Thickness 250mm

T 12@ 150
B 12@ 150

T12 @150
T 12 @150

You might also like