DESIGN CALCULATION

Name of work:- Construction of Storage Structures across the Nallahs of Sal river for ground water
recharge and water harvesting in Salcete Taluka (10 nos.).

(i) CALCULATION OF MAXIMUM FLOOD DISCHARGE :

High flood discharge level observed is upto 2.50 mts above bed level.
Cross-sectional area of river = 105.00m2
Wetted perimeter of river = 12.80mts
Bed slope of river = 1: 200
Catchment area A = 5.187 Sq.Km
By Inglis Formula:

Q= 123 x A = 123 x 5.187 = 161.93 m3/sec


√ (A + 10.4) √ (5.187 + 10.4)

Where , A = Catchment area (sq. km) = 5.187


Q = Discharge in maximum flood

DESIGN OF APRON:

Storage height = 2.50m


Bligh’s Coeffient (C) = 12

Total Creep length provided = 2x2+2x1.40+2x1+2x0.40+0.30+7.50+2x5+2.5+3.50 =33.40m

Total creep length = 33.40m

L1 = Length of D/S apron


L2 = Length of U/S apron
b = Width of bandhara

Length of D/s Apron L1 = 2.21 X C x √H/10


= 2.21 x 12x √2.50/10
= 13.26m
Provide length L1 = 13.50m

Length of U/S Apron = L2 = L – L1 = ( b +2d1+2d2+2d3)


= 33.40 -13.50 - ( 2.50 + 2x2 + 2x2+2 )
L2= 7.40m

Provide length = 7.50m

Length thickness of U/S Apron as 0.60m

Residual pressure @ A = 2.50 – 2.50 x (2+1.40+7.50+1.00) = 1.61


33.40

Thickness required = 1.33 x 1.61 = 1.53m


1.40

Provide thickness as 1.60m

Residual pressure @ ‘B’ = 2.50 – 2.50 x (13.15 +1.40+2x1+1.25) = 1.24


33.40

Thickness required = 1.33 x 1.24 = 1.178m


1.40

Provide thickness as 1.20m

Residual head @ ‘C’ = 2.50 - 2.50 x (16.80+0.40+5.00) = 0.84


33.40

Thickness required = 1.33 x 0.84 = 0.798m


1.40

Provide thickness as 0.80m

Residual head @ ‘ D’ = 2.50 – 2.50 x (22.20+0.30+5.00) = 0.45m


33.40

Thickness required = 1.33 x 0.45 = 0.42m


1.40

Provide thickness as 0.60m

Junior Engineer Assistant Engineer Executive Engineer


DESIGN CALCULATION OF ABUTMENT:

1. Height of Backfill (in mts.) = 2.80m


2. Width of Wall at Base (B in mts.) = 1.70m
3. Bearing Capacity of Soil (S.B.C) (in t/m2) = 20t/m2
4. Unit weight of Concrete (in t/m3) = 2.40t/m3
5. Unit weight of Backfill (in t/m3) = 18t/m3
6. Angle of Repose (in degree) = 300
7. Coefficient of Internal Friction (µ) = 0.60

Coefficient of Active Earth Pressure (Ka) = (1- sinØ)/ ( 1+ sinØ)


= (1- sinØ)/ ( 1+ sinØ)
= 0.333
Axtive Earth Pressure (Pa) = 0.50 x Ka x Y x H x H
= 0.50 x 0.333 x1800 x 2.80 x 2.80
= 2349.65Kg.m
Overturning Moment (Mo) = Pa x H/3
= 2349.65 X 2.80/3
= 2193.01Kg/m
Sr.no Weight (Kg/m) Lever Arm Resisting Moment
about “A” (MR) kg.m
1. W1 1.00 0.80 2.80 2400 5376.00 0.40 2150.40
2. W2 0.50 0.90 2.80 2400 3024.00 1.10 3326.40
3. W3 0.50 0.90 2.80 1800 2268.00 1.40 3175.20
∑w = 10668.00 8652.00 kg.m
Kg.m

Check against OVERTURINING: Factor of Safety (F.S.) = (Mr/Mo) = (8652.00/2193.01)


= 3.94 > 1.50 ……Hence Safe.

Check against SLIDING: Factor of safety (F.S.) = ( µ x∑ W )/ Pa = (0.60 x10668.00 )/2349.65


= 2.72 > 1.50…….Hence Safe.

Check against ECCENTRICITY: Centre of Gravity (X) = (Mr – Mo)/ ∑W

=(8652.00- 2,193.01)/10668.00 = 0.60

B/6 = 1.70/6 = 0.28


Eccentricity (e) = B/2 –(x) = 1.70/2 -0.62
= 0.23 < B/6 ……..Hence Safe .

PRESSURE DISTRIBUTION : P(maximum) = (∑W/B) x [1+(6xe/B)]


= (10668.00/1.70) x [1+ (6x0.23 /1.70)]
= 11358.28 Kg/m2
= 11.35t/m2 < 20t/m2

< S.B.C of soil …….Hence Safe.

P(minimum) = (∑W/B) x [1- (6xe/B)]


= (10668.00/1.70) x [1- (6x0.23/1.70 )]
= 1192.31Kg/m
= 1.19 t/m2< 20t/m2
< S.B.C of soil …….Hence Safe.

Junior Engineer Assistant Engineer Executive Engineer


DESIGN CALCULATION OF RETAINING WALL:

1. Height of Backfill (in mts.) = 2.80m


2. Width of Wall at Base (B in mts.) = 1.70m
3. Bearing Capacity of Soil (S.B.C) (in t/m2) = 20t/m2
4. Unit weight of Concrete (in t/m3) = 2.40t/m3
5. Unit weight of Backfill (in t/m3) = 18t/m3
6. Angle of Repose (in degree) = 300
7. Coefficient of Internal Friction (µ) = 0.60

Coefficient of Active Earth Pressure (Ka) = (1- sinØ)/ ( 1+ sinØ)


= (1- sinØ)/ ( 1+ sinØ)
= 0.333
Axtive Earth Pressure (Pa) = 0.50 x Ka x Y x H x H
= 0.50 x 0.333 x1800 x 2.80 x2.80
= 2349.65Kg.m
Overturning Moment (Mo) = Pa x H/3
= 2349.65 X 2.80/3
= 2193.01Kg/m
Sr.no Weight (Kg/m) Lever Arm Resisting Moment
about “A” (MR) kg.m
1. W1 1.00 0.40 2.80 2400 2688.00 0.20 537.60
2. W2 0.50 1.30 2.80 2400 4368.00 0.83 3625.44
3. W3 0.50 1.30 2.80 1800 3276.00 1.27 4160.52
∑w= 10332.00Kg.m 8323.56kg.m

Check against OVERTURINING: Factor of Safety (F.S.) = (Mr/Mo) = (8323.56/2193.01)


= 3.80 > 1.50 ……Hence Safe

Check against SLIDING: Factor of safety (F.S.) = ( µ x∑ W )/ Pa = (0.60 x10332.00)/2349.65


= 2.64 > 1.50…….Hence Safe

Check against ECCENTRICITY: Centre of Gravity (X) = (Mr – Mo)/ ∑W

= ( 8323.56 - 2193.01)/10332.00 = 0.59

B/6 = 1.70/6 = 0.28


Eccentricity (e) = B/2 – (x) = 1.70/2 - 0.59
= 0.26 < B/6 ……..Hence Safe .

PRESSURE DISTRIBUTION : P(maximum) =(∑W/B) x [1+(6 x e/B)]


= (10330.00/1.70) x [1+ ( 6 x 0.26/1.70)]
=11606.06 Kg/m2
=11.60t/m2 < 20t/m2

< S.B.C of soil …….Hence Safe.

P(minimum) =(∑W/B) x [1- (6 x e/B)]


= (10330.00/1.70)x[1- (6x 0.26/1.70 )]
= 546.88Kg/m
= 0.55 t/m2< 20t/m2
< S.B.C of soil …….Hence Safe.

Junior Engineer Assistant Engineer Executive Engineer