The NT10 relay is suitable for two windings MV, LV power transformers.
The adjustment of amplitude and phase current differential protection can be achieved through internal compen-
sation (sw) or through the use of external adapters.
NT10
74CT 37 46 49 50/51
- Protective & control functions
BF
52
37 Phase undercurrent
74TCS 46 Negative-sequence overcurrent
49 Thermal image
50/51 Phase overcurrent
50N.1/51N.1 87NHIZ 64REF 50N/51N
50N/51N Residual overcurrent
64REF Biased restricted differential ground fault
side H I2/I1 Phase interruption under low-load condition
87T
side L 87NHIZ High impedance restricted ground fault
87T Double slope biased differential for two
windings transformers
50N.2/51N.2 87NHIZ 64REF 50N/51N
BF Breaker Failure
74CT CTs monitoring
74TCS Trip circuit supervision
74TCS BF
74CT 37 46 49 50/51
Id
Id1=(K2/100) ∙ IS -Q
Id>>
TRIP Id1=(K1/100) ∙ IS
NO TRIP
Id>
α1 α2
0 Is
-Q
74CT 37 46 49 50/51
74TCS BF
side H
side H or side L
50N.1/51N.1
64REF 50N/51N
87NHIZ.1
side H
87T
side H or side L side L
50N.2/51N.2
64REF 50N/51N
87NHIZ.2
74TCS BF side L
74CT 37 46 49 50/51
Control functions
COMMUNICATION
- RS232
METERING - Modbus RS485
- I L1H...I L3H,I L1L...I L3L,... - Modbus TCP/IP
- Oscillography - IEC 870-5-103/DNP3
- Events & Faults log - IEC 61850
NT10
74CT 37 46 49 50/51
74TCS BF
side H
side H or side L
50N.1/51N.1
64REF 50N/51N
87NHIZ.1
side H
87T
side H or side L side L
50N.2/51N.2
64REF 50N/51N
87NHIZ.2
side L
74TCS BF
74CT 37 46 49 50/51
Control functions
COMMUNICATION
- RS232
METERING - Modbus RS485
- I L1H...I L3H,I L1L...I L3L,... - Modbus TCP/IP
- Oscillography - IEC 870-5-103/DNP3
- Events & Faults log - IEC 61850
L1 L2 L3 NT10
P2 C9
S2 A3
C10 IL1H K1
S1 A4
P1 C11 A5
C12 IL2H K2 A6
SIDE H
A7
C13
A8
OUTPUT RELAYS
C14 IL3H
K3 A9
K4 A10
P2 C15
S1 A11
IE1
S2 C16
P1 K5 A12
K6 A13
A14
CURRENT INPUTS
F1
F2
F3
RS485
B- F4
C7 Supervision
A+ F5
IE2
unit
P1 C8
S1
S2
P2
ETHERNET
SIDE L
C1
D1
HUB
C2 IL1L
P1
S1 C3
S2
P2 C4 IL2L
C5 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28
THYBUS
E1
IL3L
C6
OUTPUT INPUT
RUN
BUS
ON
1
2
3
4
5
BLOUT- 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
A17 A15
A18 BLOUT+
A16
BINARY INPUTS
A19
IN1
A20 FRONT PANEL
A21
IN2
RS232
A22
A1 ≅
UAUX
A2
NOTE
- Incoming currents to the protected transformer must match to the the reference current inputs of the relay, with current direction leaving the
protected transformer must match current output from the current inputs of the relay.
- Incoming currents in the reference terminals of of the relay current inputs are considered positive, the outgoing negative.
- This convention applies to indicate the P1 CTs polarity toward the protected transformer.
Transformer protection - differential (87) and LV side restricted earth fault protection (64REF)
P2 C9
S2 SIDE H
IL1H BF
S1 C10
P1 C11
SIDE H
C13
50N/51N
C14 IL3H
P2 C15
S1
IE1 50N.1/51N.1
S2 C16
P1
CB position
87T
CURRENT INPUTS
C7
IE2 50N.2/51N.2
C8
G SIDE L
50/51 50N/51N
C1
P2 C4 IL2L
C5
IL3L
C6
P1
S1 BF
BINARY INPUTS
S2
P2
CB position
NOTE
- Incoming currents to the protected transformer must match to the the reference current inputs of the relay, with current direction leaving the
protected transformer must match current output from the current inputs of the relay.
- Incoming currents in the reference terminals of of the relay current inputs are considered positive, the outgoing negative.
- This convention applies to indicate the P1 CTs polarity toward the protected transformer.
D1 D1
C C
A1 A1
1 1
A2 A2
9 9
ø 4.5 A3
A4
A5
2
3
10 RX
F1
F2
A3
A4
A5
2
3
10 RX
F1
F2
F3 F3
A6 11 F4 A6 11 F4
TX TX
A7 4 F5 A7 4 F5
A8 12 A8 12
5 5
A9 13 B1 A9 13 B1
A10 6 B2 A10 6 B2
171
149
200
168
177
A11 14 B3 A11 14 B3
A12 7 B4 A12 7 B4
ON 1 2 3 4 5 START ON 1 2 3 4 5 START A13 15 B5 A13 15 B5
A14 8 B6 A14 8 B6
80
TRIP TRIP
A15 16 B7 A15 16 B7
A16 B8 A16 B8
A17 A17
A18 A18
A19 A19
A20 A20
A21 A21
A22 A22
31
E1 E1
20
FLUSH MOUNTING PROJECTING MOUNTING FLUSH MOUNTING PROJECTING MOUNTING
(Separate operator panel)
SIDE VIEW
212.5 275
25 15
205 30 5 30 ø 4.5
170
161
101.6
154
Headquarter: 20139 Milano - Piazza Mistral, 7 - Tel. +39 02 574 957 01 ra - Fax +39 02 574 037 63
Factory: 35127 Padova - Z.I. Sud - Via dell’Artigianato, 48 - Tel. +39 049 894 770 1 ra - Fax +39 049 870 139 0