Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

2020 Brochure ecom-J2KNpro

Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

INTELLIGENT MESSEN!

MEASURE WITH INTELLIGENCE!

pro
J2KN
Flue Gas Analysis

ADDRESS

AM GROSSEN TEICH 2
D-58640 ISERLOHN

TEL.: +49 (0) 2371 | 945 - 5


FAX: +49 (0) 2371 | 40305
info@ecom.de
www.ecom.de

ecom GMBH
ecom PRODUCTS OFFER YOU MANY BENEFITS...

EXTREMELY EFFICIENT. EXTREMELY ACCURATE. EXTREMELY COMPLETE. EXTREMELY COOL.

The high output level (up to 2.6 liters/ The reading accuracy of gas ecom analyzers are sold and de- The drier, the better: The gas to be
minute) not only enables ecom analy- sensors (CO, NO, SO2) is signed as an entity (device, probe, measured is continually cooled to
zers to provide a fast reading: It also determined and adjusted at 5, probe hose, case). In addition: 5°C using a gas cooler. This way,
makes it possible to bridge long dis- 20 and 40°C in the climatic test Printer paper and filter, a solid the drying processis controlled.
tances during sampling, or negative chamber using standarized test shoulder strap, PC software and Collected condensate can be
pressure in the application. gases. High-quality sensors Apps. easily emptied in some cases this
Manometers also provide provide a perfect reading for occurs in automatic mode.
readings in record time. pressure measurements.

EXTREMELY FAR-REACHING. EXTREMELY ROBUST. EXTREMELY SAFE. EXTREMELY LOSS-FREE.

ecom analyzers communicate Hard on the outside - even harder The condensation control protects To measure the full concentration
wirelessly: Via Bluetooth as well on the inside! Almost all ecom from moisture. An automatic of extremly water soluble gases
as radio (highest range with the measuring devices are housed in an CO shut-off (flushing of the CO an inner PTFE coated hose or
most stable connection). This way ultra-light aluminium casing. Its sensor) without interruption of the a heated sampling system are
instruments can be remote- durability pays off in its daily use - measuring process ensures the available. This guarantees the fast
controlled via e.g smartphones or especially in rougher conditions. long lifespan of the CO sensor. and condensate free flue gas
ecom remote control unit. Each ecom instrument has its own transport.
„safety equipment.“

ecom GmbH | Am Grossen Teich 2 | D-58640 Iserlohn | www.ecom.de | Stand Jun. 20


...BY EVERY
APPLICATION.

HEATING
Combustion gas analysers, pressure meters, leak detectors and more
for the HVAC handicraft, chimney-sweep and heating after-sales service.
For control and adjustment works in order to reduce emissions and to
optimize the efficiency of heating plants.

ENGINES
For control and adjustment works among all by commissioning of gas
engines, thermal power blocks, etc. as well for the perfect measurement
of water-soluble gases like nitrogen oxide – especially recommended for
the NOx measurement.

COMBUSTION
Combustion gas analysers, pressure meters, leak detectors and more
for control and adjustment works at burners and large-scale firing plants
in order to reduce emissions, to arrange for a more efficient combustion
process and to optimize the thermal process.

INDUSTRY
Combustion gas analysers, pressure meters, leak detectors and more
for the perfect preparation of water-soluble gases (i.a. NO2 and SO2) by
industrial applications (like e.g. aluminium process, coke oven plants,
cement processing, power plants, refineries, waste incineration…).

ecom GmbH | Am Grossen Teich 2 | D-58640 Iserlohn | www.ecom.de | Stand Jun. 20


Overview of technical data
√ Standard • Option x Not possible

J2KNpro
Flue gas analyser model J2KNpro
Industry
max. 6
Gas Components Resolution Accuracy max. 6
+ NDIR*

O2 O2 (0 - 21 vol.%) - electrochemical 0,01 vol.% ± 0,3 vol.% √ √

CO CO (H2-komp. 0 -10.000 ppm) - electrochemical 1 ppm ± 20 ppm or 5 % of reading** √ √

CO (n. H2-komp. 0 -20.000 ppm) - electrochemical 1 ppm ± 40 ppm or 10 % of reading** • •

CO% (0 -63.000 ppm) - electrochemical 5 ppm ± 100 ppm or 10 % of reading** • •

CO% (0 -63.000 ppm) - NDIR* bank 10 ppm ± 200 ppm or 3 % of reading** x •

CO2 CO2 (0 - 20 vol.%) - NDIR* sensor 0,01 vol.% ± 0,5 vol.% or 5 % of reading** x
Optional:
IR bank

NOX NO (0 - 5.000 ppm) - electrochemical 1 ppm ± 5 ppm or 5% of reading** • •

NOLow (0 - 300 ppm) - electrochemical 0,1 ppm ± 2 ppm or 5 % of reading** • •

NO2 (0 - 1.000 ppm) - electrochemical 1 ppm ± 5 ppm or 5 %of reading** • •

NO2 Low (0 - 100 ppm) - electrochemical 0,1 ppm ± 5 ppm or 5 % of reading** • •

via via
NOx - measuring - electrocemical
NO/NO2 NO/NO2

SO2 SO2 (0 - 5.000 ppm) - electrochemical 1 ppm ± 10 ppm or 5 % of reading** • •


SO2 (0 - 5.000 ppm) - electrochemical Low CO 1 ppm ± 10 ppm or 5 % of reading** • •

H2 H2 (0 - 2.000 ppm) - electrochemical 1 ppm ± 10 ppm or 5 % of reading** • •

H2 (0 - 20.000 ppm) - electrochemical 1 ppm ± 100 ppm or 5 % of reading** • •

H2S H2S (0 - 1.000 ppm) - electrochemical 1 ppm ± 10 ppm or 5 % of reading** • •

H2S (0 - 5.000 ppm) - electrochemical 1 ppm ± 50 ppm or 5 % of reading** • x

CxHy CxHy (0 - 4 vol.%) - catalytic 0,01 vol.% • •

CH4 (0 - 100 vol.%) - NDIR* sensor 0,1 vol.% up to ± 5 % measur range endvalue • •

CxHy (CH4 0 - 3 vol.%) - NDIR* bank 0,001 vol.% ± 0,005 vol.% or 3 % of reading** x •


CxHy (C3H8 0 - 2.000 ppm) - NDIR* bank 1 ppm ± 4 ppm or 3 % of reading** x

Additional Measurements | Display Options Resolution Accuracy


T-Gas 0 - 500 °C 1 °C ± 2 °C or 1,5 % of the reading** √ √

0 - 1.100 °C 1 °C ± 2 °C or 1,5 % of the reading** • •

T-Air 0 - 99 °C 1 °C ± 1 °C √ √

Pressure | ΔP ± 100 hPa 0,01 hPa ± 0,5 hPa or 1 % of the reading** √ √

Calculated values
CO2 - 0 - CO2 max √ √
Combustion efficiency (ETA) √ √
Excess air (Lambda) - > 1 √ √
Losses qA - 0 - 100 % √ √
Dew point - x °C √ √
mg/m³ - x mg/m³ √ √
mg/KWh - x mg/KWh √ √
O2 - reference- x % O2 √ √

* NDIR = non dispersive infrared technology


** the higher value prevails

ecom GmbH | Am Grossen Teich 2 | D-58640 Iserlohn | www.ecom.de | Stand Jun. 20


√ Standard • Option x Not possible

J2KNpro
Flue gas analyser model J2KNpro
Industry

Gas processing

Electronic condensation monitoring √ √


Automatic condensation evacuation √ √
Electronic gas cooler • √

Operation safety
Temperature trend indication for core stream search √ √
CO switch-off √ √
Fresh air purge by CO exceeding √ √
Fresh air purge after operation √ √
Flow meter for pump performance control √ √

Sampling system
Heated probe, type SB √ •
Unheated probe, type SU • •
Heated probe with integrated PTFE filter and thermocouple (for heated sampling system) x •

Gas transportation (tubing hose)


Multi-chamber silicone tubing √ •
NOx / SOx special tubing with PTFE inner coating • •
Heated tubing (in combination with heated sampling system) x •

Printer
Thermal quick-printer, integral √ √
Dot matrix printer • •

Data processing
Serial interface for data transfer √ √
USB interface for data transfer √ √
Wireless data interface (e.g. for connection to a smartphone or tablet) √ √
Data recording on mulimedia card • •
Reception possibility for diagnosis data from ecom-AK √ √

Remote control
via backlit keypad √ √
via radio remote √ √
via smartphone/tablet (free iOS + Android app) √ √

Transport
Aluminum-framed transport case √ √

Under case • •

* NDIR = non dispersive infrared technology


** the higher value prevails

ecom GmbH | Am Grossen Teich 2 | D-58640 Iserlohn | www.ecom.de | Stand Jun. 20


pro
J2KN
FLUE GAS ANALYSIS

ecom-J2KNpro EASY
POWERFUL FLUE GAS ANALYZER RADIO REMOTE CONTROL
WITH RADIO REMOTE CONTROLLER (INCLUDED IN DELIVERY)

- O2 / CO (H2-comp.) Longlife sensors ­- Wide coverage for bridging distances between the measuring
- Up to 6 electrochemical sensors possible point and adjustment point
- Durable aluminum housing fitted in aluminum framed case - Includes thermocouple, mini-USB connection
- Brushless high-performance pump (data transfer to laptop / PC), SD card slot
- Powerful Lithium-Ion battery - Foil keypad with high-quality TFT color display
- CO sensor overload protection without interruption - Display, printing and storage of measurement data
of the measurement - Full instrument operation (including manual CO shut off,
- Multi-level sample gas filtering starting and terminating measurements, data processing, ...)
- Electronic condensate monitoring - Reliable data transfer via radio (best-possible prevention of
- Heated sampling probe (300 mm), cone and 3-chamber interferences, bypassing of metal or concrete obstacles,
sampling tubing (3 m) automatic connection establishment, no abrupt disruption of
- Integrated soot measurement connection with maintenance of all measuring data, as well
- Integrated thermal fast printer as automatic connection and re-establishment of a radio
- Instrument internal heating connection)
- Status display
- Calibration certificate
- Wireless data interface (e.g. for connection to a smartphone
or tablet)

Measureable Gases

Dimensions (W x H x D) app. 450 x 315 x 250 mm


or. 510 x 330 x 250 mm (depending on version)
Weight app. 12 kg (in transport case) = Base; = Optional EC; = Optional NDIR; = Optional Pellistor

ACCURATE ROBUST EFFICIENT SAFE

ecom GmbH | Am Grossen Teich 2 | D-58640 Iserlohn | www.ecom.de | Stand Jun. 20


Testing according to DIN EN 50379-2
and 1st. BImSchV.

ecom-J2KNpro EXPERT ecom-J2KNpro ENGINE


FOR PERFECT NOX /SO2- MEASUREMENTS FOR MEASUREMENTS AT CHPS AND ENGINES

- NOx version (equipment with O2 / CO / NO / NOx sensors) - NOx version (equipped with O2 / CO / NO / NO2 sensors)
- Up to 6 electrochemical sensors possible - Up to a total of 6 gas sensors (including SO2 or IR CO2
- Low-NOx version also possible or CH4sensors)
- Sample gas cooler including electronic condensate monitoring - Electronically monitored sample gas cooler
and automatic condensate drain - Preset for NOx measurements, as well as mg/m3 at 5% O2
- With heated sampling probe (300 mm), cone and NOx tubing (3,5 m) reference (freely adjustable)
- With sampling probe (360 mm) including miniature heat shield on
the probe cone, cone and 2-chamber NOx-tubing (3.5 m)
ADDITIONAL OPTIONS

- Additional sensor options (SO2, H2S, H2, CO%)


- Higher resolution and accuracy in the NO-Low (0-300 ppm) or
NO2-Low (0-100 ppm) range
- Measurement of flow velocity in flue gas
- Probe tubing available in different lengths
- Exchangeable probe tips in different lengths
(high-temperature and flexible versions)

Measureable Gases Measureable Gases

= Base; = Optional EC; = Optional NDIR; = Optional Pellistor = Base; = Optional EC; = Optional NDIR;

FAR-REACHING COMPLETE COOL LOSS-FREE

ecom GmbH | Am Grossen Teich 2 | D-58640 Iserlohn | www.ecom.de | Stand Jun. 20


ecom-J2KNpro INDUSTRY
EMISSION ANALYZER FOR INDUSTRIAL RADIO REMOTE CONTROL
(PROCESS) MEASUREMENTS (INCLUDED IN DELIVERY)

- O2 / CO (H2-comp.) Longlife sensors ­- Wide coverage for bridging distances between the measuring
- More than 8 gas components (Longlife + NDIR) point and adjustment point
- Up to 6 electrochemical sensors possible - Includes thermocouple, mini-USB connection
- Possibility of additional infrared measurement of up (data transfer to laptop / PC), SD card slot
to 3 gas components - Foil keypad with high-quality TFT color display
- Durable aluminum housing fitted in aluminum framed case - Display, printing and storage of measurement data
- Brushless high-performance pump - Full instrument operation (including manual CO shut off,
- Powerful Lithium-Ion battery starting and terminating measurements, data processing, ...)
- CO sensor overload protection without interruption of the - Reliable data transfer via radio (best-possible prevention of
measurement interferences, bypassing of metal or concrete obstacles,
- Multi-level sample gas filtering automatic connection establishment, no abrupt disruption of
- Electronic condensate monitoring connection with maintenance of all measuring data, as well
- Connection for heated sampling system as automatic connection and re-establishment of a radio
- TFT colour display and keyboard - illuminated connection)
- Integrated thermal quick printer
- Instrument internal heating
- Foldable antenna
- Calibration certificate
- Wireless data interface (e.g. for connection to smartphone
or tablet)

Dimensions (W x H x D) approx 510 x 330 x 250 mm


Weight approx 14 kg (in transport case)

ACCURATE ROBUST EFFICIENT SAFE

ecom GmbH | Am Grossen Teich 2 | D-58640 Iserlohn | www.ecom.de | Stand Jun. 20


Testing according to DIN EN 50379-2
and 1st. BImSchV.

FOR CONTINIOUS MEASUREMENTS ADDITIONAL OPTIONS


(UP TO 48 HOURS)

- Equipped for continuous measurements in plants - NOx calculation via NO sensor or NOx measurement
(up to 48 hours) with programmable measurement intervals (NO + NO2 sensor) available
- Connection for heated sampling system (accessory) - Additional sensor options (SO2, H2S, H2, CO%)
- Status display showing basic features, settings and alerts - Higher resolution and accuracy in the NO-Low (0-300 ppm) or
- Large NOx filter for protection of the CO sensor NO2 -Low (0-100 ppm) range
- T-Room sensor/ T-Room stick (on request or depending - Infrared measurement (NDIR) of CO2 (direct measurement),
on equipment package) CO-high as well as CxHy (calibrated to CH4 methane or
- Integrated soot measurement (included in standard delivery C3H8 propane)
depending on probe equipment) - CxHy measurement via catalytic measuring method (Pellistor)
- Stainless steel sample gas cooler for loss-free sample gas
treatment for water soluble gases
- Measurement of flow velocity in flue gas

Measureable Gases

= Base; = Optional EC; = Optional NDIR; = Optional Pellistor

FAR-REACHING COMPLETE COOL LOSS-FREE

ecom GmbH | Am Grossen Teich 2 | D-58640 Iserlohn | www.ecom.de | Stand Jun. 20


USEFUL

ecom-AK
READOUT UNIT FOR DIGITAL AUTOMATIC
BURNER CONTROLLERS

- Automatic identification of
automatic burner controller type
- Readout feature for errors and operating conditions
- Built-in display
- Data transfer via cable to PC or ecom-EN3 analyzer
- Data transfer via radio to the ecom-J2KNpro
control panel (display + printing via flue gas analyzer)

Displayed data:
- Display of recent and past failures
- Display of burner operating conditions
- Measurement of the flame signal/comparison with ecom-AK will show the following display messages:
minimum value
Identification of burner controller (Honeywell-Satronic DKG, DKO, DKW,
- Checks of delayed flame development DMO, DMG, DLG, DVI, DIO, SH, SG incl. N versions as well as Sie-
- Detection of the number of burner starts mens-Landis & Staefa LMG, LMO).
- Display of all relevant operating times (safety time, etc.)
Indication of burner operating mode.

Dimensions (W x H x D) approx. 88 x 41 x 32 mm
Measurement of flame signal and comparison with minimal value.
Weight approx. 322 g - incl. belt pouch

Check if flame occurs immediately or with delays.

Indication of current disturbance source as well as


of 5 past disturbances.

ROBUST COMPLETE EFFICIENT


Determination of burner starts.

ecom-UNO ecom-LSG
FOR THE ADJUSTMENT OF GAS BURNERS /GAS HEATINGS DETECTION OF FLAMMABLE GASES

- Device connection pressure (flow pressure) - Three sensitivity levels adjustable


- Nozzle pressure (flow pressure) - Accoustic signal on/off at choice
- Gas operating pressure (system pressure) - Display range up to 0.5% vol. CH4, Response time: < 2 seconds
- Static pressure - Backlit bargraph
- Switchable units: hPa / mbar, mmH2O, psi, mmHg - Display approx. 20 x 7 mm
- Measurement range: ± 200 hPa, ± 2038 mmH2O, - 1-14 bars (10 bars = approx. 1000 ppm CH4)
± 2.9 psi, ± 150 mmHg - Warm-up time: approx. 3 minutes
- Resolution: 0.01 hPa / 0.01 mmH2O / 0.01 psi / 0.01 mmHg - Sensor temperature compensation (-5°C to 40°C)
- Accuracy: approx. 1%
- Overload: 300 hPa / 3060 mmH2O / 4.35 psi / 225 mmHg

Dimensions (W x H x D) approx. 106 x 64 x 28 mm Dimensions housing (W x H x D) approx. 155 x 35 x 22 mm


Weight approx. 150 g Swan-neck: approx. 355 mm
Weight: approx. 200 g

ecom GmbH | Am Grossen Teich 2 | D-58640 Iserlohn | www.ecom.de | Stand Jun. 20


ACCESSORIES

Filter plate Probe prefilter Probe extension


Multi-level processing: water separation in Metal filter with the smallest filter pores; ideal For probe type Ø 8 mm, with flexible tube
condensate trap; pre filtering via fine particulte for preventing that solid exhaust gas compo- center piece. Is placed on the probe seats
filter; silica gel drying; removal of sensor-da- nents enter into the probe/the flue gas tract. for measurements at difficult to reach, angled
maging, organic compounds in the measuring openings.
hydrocarbon filter.

CO multi-hole probe Ring slot multi-hole probe Contact sensor


For the CO measurement of the CO For measurement on concentric exhaust Forerun and backrun temperature
concentration according to KÜO (sweeping systems. Continuously extendable measurement.
and monitoring system) (80 to 280 mm) - with three easily replaceable
extendable from 80 to 280 mm. sealing plugs for measuring openings from
Ø 5 to 25 mm.

T-Room-probe (PT 2000) Soot pump set Under case


For measuring the room or intake air Consisting of soot pump, soot comparison For the storage of accessories, tools,
temperature - for example for concentric scale, piston lubricant oil, socket wrench and and small devices.
flue gas systems. 200 soot test strips.

Other accessories on demand.

ecom GmbH | Am Grossen Teich 2 | D-58640 Iserlohn | www.ecom.de | Stand Jun. 20


HEADQUARTER

ecom GmbH
Am Grossen Teich 2
58640 Iserlohn
GERMANY

www.ecom.de

ecom (Beijing) Co., Ltd.


Unit 05 room 301
ECOM AMERICA Ltd. Ecom SAS 3rd floor building 2
1628 Oakbrook Drive 5, rue de Lisbonne courtyard 9 Jiuxianqiao East Road
30507 Gainesville, Georgia 67300 Schiltigheim Chaoyang District, Beijing
USA FRANCE CHINA

www.ecomusa.com www.ecom.fr www.ecomchina.com.cn

Partner Find your international partner on


www.ecom.de/en/kontakt/

ecom GmbH | Am Grossen Teich 2 | D-58640 Iserlohn | www.ecom.de | Stand Jun. 20

You might also like