SLC ADAPT Modular On-line double conversion UPS 10-900 kVA

SLC ADAPT: Flexibility, availability and reliability in superior electrical protection


Salicru’s SLC ADAPT series consists of modular On-line double conversion uninterruptible power supply (UPS) solutions with DSP
control and three-level IGBT inverter technology.

Flexibility: It enables solutions to be configured from 10 kVA to 900 kVA, thanks to the wide range of modules available (10, 15, 20, 25
and 30 kVA), different configurable systems (3, 6 or 10 modules) and the parallel/redundant option of up to three 300 kVA systems. It
also provides increased protection as needs grow - pay as you grow - thereby improving total cost of ownership (TCO).

Availability: Its hot-swap modules can be added or replaced during operation, thereby improving mean time to repair (MTTR) and
reducing maintenance costs. In addition, the system’s remote management, which can be integrated into any platform, also facilitates
operation. And the extensive back-up options available, along with intelligent battery charging, ensure continuous operation of the
protected critical loads.

Reliability: Its DSP control, based on three-level PWM technology, improves response effectiveness and, along with shared load
redundancy, significantly extends the mean time between failures (MTBF). Moreover, both the control display and the bypass module
can be replaced without affecting the operation of the device.

Performances
· On-line double conversion technology with modular architecture.
· 10, 15, 20, 25 and 30 kVA modules with DSP control and three-level PWM technology.
· 3, 6 or 10-module systems (up to 300 kVA per system).
· Possibility of parallel/redundant operation up to 900 kVA.
· Hot-pluggable and swappable plug & play modules.
· Input power factor >0.99.
· Input current distortion (THDi) <3%.
· Three-phase input / output voltages. (1)
· Output power factor = 0.9.
· Control and management by means of LCD display, LEDs and keypad.
· Efficiency in On-line mode >95%.
· 99% performance in Eco-mode operation.
· RS-232, RS-485, relays and USB (2) communication channels.
· Smart slots for extended relays (2) and SNMP.
· Smart-efficiency mode to optimize system performance. (2)
· Improved return on investment (ROI).
· Compact design to save space in server rooms.
· SLC Greenergy solution.
(1) Possibility of single-phase input/output up to 20 kVA. And three-phase input and single-phase output up to 40 kVA. SLC ADAPT
(2) Only in systems with 25 and 30 kVA modules.

Applications: Redundant protection for critical applications


Data centres with all capacities, IT infrastructures, modular and virtualised data centres and applications for critical processes are
some of the services that require high-level electrical protection to ensure reliable, continuous and high-quality operation, such as
that provided by Salicru’s SLC ADAPT series systems.
REF. JM912A01 CODE 401AB000770 ED. AUGUST 2015 UNINTERRUPTIBLE POWER SUPPLIES (UPS)

Modularity
SLC ADAPT
Modular On-line double conversion UPS 10-900 kVA
TECHNICAL SPECIFICATIONS
MODEL SLC ADAPT
Module power 10 / 15 / 20 kVA 25 / 30 kVA
TECHNOLOGY On-line double conversion, three-level PWM, DSP control
INPUT Nominal voltage 3 x 380 / 3 x 400 / 3 x 415 V (3Ph + N)
Voltage range -40% +25%(1) -43% +20%(1)
Frequency 50 / 60 Hz
Total harmonic distortion (THDi) ≤3%
Power factor >0.99
OUTPUT Nominal voltage 3 x 380 / 3 x 400 / 3 x 415 V (3Ph + N)
Accuracy ±1% (static mode) / ±1.5% (dynamic mode)
Frequency 50/60 Hz ±2 Hz (2) 50/60 Hz ±3 Hz (2)
Total harmonic distortion (THDv) ≤1.5% for linear loads / <1% for linear loads
≤5% for non linear loads <6% for non linear loads
(EN-IEC 62040-3) (EN-IEC 62040-3)
Power factor 0.9
Crest factor 3:1
Total efficiency in On-line mode >95%
Total efficiency in battery mode >95%
Total efficiency in Eco mode 99%
Admissible overload 125% for 10 mins / 150% for 1 min
STATIC BYPASS Type Static thyristor
Voltage 3 x 380 / 3 x 400 / 3 x 415 V (3FPh+ N)
Voltage range ±20% (adjustable) -20% +15% (adjustable)
1. Manual bypass.
MANUAL BYPASS Type Uninterrupted
2. Battery start-up. BATTERIES Type Lead-acid, sealed, maintenance-free
3. LCD display. Voltage load regulation Batt-watch
4. Bypass module. Precision float charger ±1%
5. Dry contacts. Charger maximum power 20% of total system power

6. Extended relays and SNMP slot. COMMUNICATION Display Touchscreen, 5.7”, LEDs and keypad Touchscreen, 10.4”, LEDs and keypad
Ports RS-232, RS-485 and relays RS-232, RS-485, relays and USB
7. RS-232, RS-485 and USB interfaces. Free slots 1 x SNMP 1 x SNMP / 1 x extended relays
8. Power modules. GENERAL Operating temperature 0º C ÷ +40º C
Relative humidity Up to 95%, non-condensing
Display

Data may change without previous notice.


Operating altitude 2,400 masl (3)
Acoustic noise at 1 metre <55 dB(A) <65 dB(A)
SYSTEMS Maximum no. modules per system 3, 6 or 10 10
Maximum power per system (kVA) 60, 120, 200 300
Maximum no. parallel systems 2 3
Maximum power parallel systems (kVA) 120, 240, 400 900
STANDARDS Safety EN-IEC 62040-1
Electromagnetic compatibility (EMC) EN-IEC 62040-2
Operation VFI-SS-111 as per EN-IEC 62040-3
Quality and environmental management ISO 9001 and ISO 14001
(1) Depending on load percentage. (2) Selectable range. (3) 1% derating power every 100 m over 1000 m.
Display consisting of operation keys, status
LEDs and touch screen detailing all functions, RANGE
measurements and alarms.
MODULES
(1) Para un módulo a plena carga POWER (kVA / kW) DIMENSIONS (D x W x H mm.) WEIGHT (Kg)
Options SLC ADAPT 10 10 / 9 590 x 440 x 134 20
SLC ADAPT 15 15 / 13.5 590 x 440 x 134 21
· Extended relays and SNMP adapter.
(1)
SLC ADAPT 20 20 / 18 590 x 440 x 134 22
· Extended back-up times. SLC ADAPT 25 25 / 22.5 790 x 460 x 134 34
· Dust filter. SLC ADAPT 30 30 / 27 790 x 460 x 134 34
· Kit for parallel systems.
· Frequency converter operation. SYSTEMS NO. MODULES MOD. POWER MAX. POWER DIMENSIONS(1) WEIGHT
(#) (kVA / kW) (kVA / kW) (D x W x H mm.) (Kg)
(1) Only for 25 and 30 kVA module systems.
SLC-#/10-ADAPT 30 1 to 3 10 / 9 30 / 27 900 x 600 x 1000 120 ÷ 180

Technical support and service SLC-#/15-ADAPT 45


SLC-#/20-ADAPT 60
1 to 3
1 to 3
15 / 13.5
20 / 18
45 / 40.5
60 / 54
900 x 600 x 1000
900 x 600 x 1000
120 ÷ 183
120 ÷ 186
. Pre-sales and after-sales advice. SLC-#/10-ADAPT 60 1 to 6 10 / 9 60 / 54 900 x 600 x 1600 187 ÷ 270
. Start-up. (1) SLC-#/15-ADAPT 90 1 to 6 15 / 13.5 90 / 81 900 x 600 x 1600 187 ÷ 276
. Technical support by telephone. SLC-#/20-ADAPT 120 1 to 6 20 / 18 120 / 108 900 x 600 x 1600 187 ÷ 282
SLC-#/10-ADAPT 100 1 to 10 10 / 9 100 / 90 900 x 600 x 2000 214 ÷ 380
. Preventive/corrective services.
SLC-#/15-ADAPT 150 1 to 10 15 / 13.5 150 / 135 900 x 600 x 2000 214 ÷ 390
. Maintenance contracts. (1) SLC-#/20-ADAPT 200 1 to 10 20 / 18 200 / 180 900 x 600 x 2000 214 ÷ 400
. Training courses. SLC-#/25-ADAPT 250 1 to 10 25 / 22.5 250 / 225 1100 x 600 x 2000 200 ÷ 560
(1) Ask for local conditions SLC-#/30-ADAPT 300 1 to 10 30 / 27 300 / 270 1100 x 600 x 2000 200 ÷ 560
(1) Batteries located in additional cabinets.
@salicru_SA www.linkedin.com/company/salicru Nomenclature, dimensions and weights for devices with input voltage 3 x 400 V, output voltage 3 x 400 V.

+34 93 848 24 00 WWW.SALICRU.COM


AVDA. DE LA SERRA 100 · 08460 PALAUTORDERA (SPAIN) · FAX +34 93 848 11 51 · salicru@salicru.com

You might also like