Salicru SLC ADAPT Datasheet
Salicru SLC ADAPT Datasheet
Salicru SLC ADAPT Datasheet
SUPPLIES (UPS)
LIGTHING FLOW DIMMER-
STABILISERS
DC POWER SYSTEMS
STATIC INVERTERS
PHOTOVOLTAIC INVERTERS
VOLTAGE STABILISERS
TECHNICAL SUPPORT & SERVICE
Flexibility: It enables solutions to be configured from 10 kVA to 900 kVA, thanks to the wide range of modules available (10, 15, 20, 25
and 30 kVA), different configurable systems (3, 6 or 10 modules) and the parallel/redundant option of up to three 300 kVA systems. It
also provides increased protection as needs grow - pay as you grow - thereby improving total cost of ownership (TCO).
Availability: Its hot-swap modules can be added or replaced during operation, thereby improving mean time to repair (MTTR) and
reducing maintenance costs. In addition, the system’s remote management, which can be integrated into any platform, also facilitates
operation. And the extensive back-up options available, along with intelligent battery charging, ensure continuous operation of the
protected critical loads.
Reliability: Its DSP control, based on three-level PWM technology, improves response effectiveness and, along with shared load
redundancy, significantly extends the mean time between failures (MTBF). Moreover, both the control display and the bypass module
can be replaced without affecting the operation of the device.
Performances
· On-line double conversion technology with modular architecture.
· 10, 15, 20, 25 and 30 kVA modules with DSP control and three-level PWM technology.
· 3, 6 or 10-module systems (up to 300 kVA per system).
· Possibility of parallel/redundant operation up to 900 kVA.
· Hot-pluggable and swappable plug & play modules.
· Input power factor >0.99.
· Input current distortion (THDi) <3%.
· Three-phase input / output voltages. (1)
· Output power factor = 0.9.
· Control and management by means of LCD display, LEDs and keypad.
· Efficiency in On-line mode >95%.
· 99% performance in Eco-mode operation.
· RS-232, RS-485, relays and USB (2) communication channels.
· Smart slots for extended relays (2) and SNMP.
· Smart-efficiency mode to optimize system performance. (2)
· Improved return on investment (ROI).
· Compact design to save space in server rooms.
· SLC Greenergy solution.
(1) Possibility of single-phase input/output up to 20 kVA. And three-phase input and single-phase output up to 40 kVA. SLC ADAPT
(2) Only in systems with 25 and 30 kVA modules.
Modularity
SLC ADAPT
Modular On-line double conversion UPS 10-900 kVA
TECHNICAL SPECIFICATIONS
MODEL SLC ADAPT
Module power 10 / 15 / 20 kVA 25 / 30 kVA
TECHNOLOGY On-line double conversion, three-level PWM, DSP control
INPUT Nominal voltage 3 x 380 / 3 x 400 / 3 x 415 V (3Ph + N)
Voltage range -40% +25%(1) -43% +20%(1)
Frequency 50 / 60 Hz
Total harmonic distortion (THDi) ≤3%
Power factor >0.99
OUTPUT Nominal voltage 3 x 380 / 3 x 400 / 3 x 415 V (3Ph + N)
Accuracy ±1% (static mode) / ±1.5% (dynamic mode)
Frequency 50/60 Hz ±2 Hz (2) 50/60 Hz ±3 Hz (2)
Total harmonic distortion (THDv) ≤1.5% for linear loads / <1% for linear loads
≤5% for non linear loads <6% for non linear loads
(EN-IEC 62040-3) (EN-IEC 62040-3)
Power factor 0.9
Crest factor 3:1
Total efficiency in On-line mode >95%
Total efficiency in battery mode >95%
Total efficiency in Eco mode 99%
Admissible overload 125% for 10 mins / 150% for 1 min
STATIC BYPASS Type Static thyristor
Voltage 3 x 380 / 3 x 400 / 3 x 415 V (3FPh+ N)
Voltage range ±20% (adjustable) -20% +15% (adjustable)
1. Manual bypass.
MANUAL BYPASS Type Uninterrupted
2. Battery start-up. BATTERIES Type Lead-acid, sealed, maintenance-free
3. LCD display. Voltage load regulation Batt-watch
4. Bypass module. Precision float charger ±1%
5. Dry contacts. Charger maximum power 20% of total system power
6. Extended relays and SNMP slot. COMMUNICATION Display Touchscreen, 5.7”, LEDs and keypad Touchscreen, 10.4”, LEDs and keypad
Ports RS-232, RS-485 and relays RS-232, RS-485, relays and USB
7. RS-232, RS-485 and USB interfaces. Free slots 1 x SNMP 1 x SNMP / 1 x extended relays
8. Power modules. GENERAL Operating temperature 0º C ÷ +40º C
Relative humidity Up to 95%, non-condensing
Display