Construction Documentation Bill of Quantities for Concrete Works

COSTING FOR PROPOSED CONCRETE WORKS OF PUBLIC BUILDING


FOR ST. JOHNS COALESCE COMMUNITY CENTER AT
SITE 4 HIGH STREET
ST. JOHNS
ANTIGUA AND BARBUDA

ITEM DESCRIPTION QTY UNIT RATE AMOUNT $


GROUND FLOOR

BILL #1
SUPER-STRUCTURE
F CONCRETE WORK
F10 In-situ Concrete

Reinforced Concrete (1:2:4) mix, 21 Mpa in the following:

A Beams and Lintels 17 m3 28,000.00 476,000.00

B Stiffeners 9 m3 28,000.00 252,000.00

3
C Round Columns 4 m 28,000.00 112,000.00

3
D Arch 7 m 28,000.00 196,000.00

Carried to collections 1,036,000.00


B1/P1

Prepared By George Watson 1701370


Construction Documentation Bill of Quantities for Concrete Works

COSTING FOR PROPOSED CONCRETE WORKS OF PUBLIC BUILDING


FOR ST. JOHNS COALESCE COMMUNITY CENTER AT
SITE 4 HIGH STREET
ST. JOHNS
ANTIGUA AND BARBUDA

ITEM DESCRIPTION QTY UNIT RATE AMOUNT $


GROUND FLOOR CONTINUED

BILL #2
SUPER-STRUCTURE CONTINUED
F CONCRETE WORK CONTINUED
F20 Bar Reinforcement

Mild Steel bar reinforcement, fixed in place including cutting to


lengths, bending and tying as required with binding wire in the
following:

A 12mm diameter nominal size general bars in lintels. 211 kg 210.00 44,310.00

B 12mm diameter nominal size general bars in arch lintels. 98 kg 210.00 20,580.00

C 16mm diameter nominal size general bars in lintels. 167 kg 210.00 35,070.00

D 10mm diameter nominal size used as links in lintels. 122 kg 210.00 25,620.00

E 10mm diameter nominal size used as links in arch lintels. 99 kg 210.00 20,790.00

F 12mm diameter nominal size general bars in beams. 244 kg 210.00 51,240.00

G 10mm diameter nominal size used as links in beams. 74 kg 220.00 16,280.00

H 12mm diameter nominal size general bars in stiffeners. 163 kg 210.00 34,230.00

J 10mm diameter nominal size used as stirrups in stiffeners. 89 kg 220.00 19,580.00

K 12mm diameter nominal size general bars in columns. 77 kg 210.00 16,170.00

L 10mm diameter nominal size used as stirrups in columns. 51 kg 220.00 11,220.00

Carried to collections 295,090.00


B2/P1

Prepared By George Watson 1701370


Construction Documentation Bill of Quantities for Concrete Works

COSTING FOR PROPOSED CONCRETE WORKS OF PUBLIC BUILDING


FOR ST. JOHNS COALESCE COMMUNITY CENTER AT
SITE 4 HIGH STREET
ST. JOHNS
ANTIGUA AND BARBUDA

ITEM DESCRIPTION QTY UNIT RATE AMOUNT $


GROUND FLOOR CONTINUED

BILL #3
SUPER-STRUCTURE CONTINUED
F CONCRETE WORK CONTINUED
F30 Formwork

A Belt beams sides and soffits regular shaped 37 m2 3,100.00 114,700.00

B Lintels sides regular shaped 59 m2 3,100.00 182,900.00

C Columns round shaped 22 m2 3,100.00 68,200.00

D Stiffeners sides regular shape 27 m2 3,100.00 83,700.00

E Arch sides and soffits 54 m2 3,100.00 167,400.00

Carried to collections 616,900.00


B3/P1

Prepared By George Watson 1701370


Construction Documentation Bill of Quantities for Concrete Works

COSTING FOR PROPOSED CONCRETE WORKS OF PUBLIC BUILDING


FOR ST. JOHNS COALESCE COMMUNITY CENTER AT
SITE 4 HIGH STREET
ST. JOHNS
ANTIGUA AND BARBUDA
ITEM DESCRIPTION QTY UNIT RATE AMOUNT $

CONCRETE WORKS

SUMMARY

COLLECTIONS

Carried from In-site Concrete 1,036,000.00

Carried from Bar Reinforcements 295,090.00

Carried from Formwaork 616,900.00

Sub-Total 1,947,990.00

Carried to Summary 1,947,990.00

Prepared By George Watson 1701370