Analyzer 586 51 Lab Total Sulfur
Analyzer 586 51 Lab Total Sulfur
Analyzer 586 51 Lab Total Sulfur
Product Features
• ASTM method references
Applications
• Naphtha • Dirty/clean Water • Diesel • Fuel Oil • Drilling Fluid • Condensate • Quality control • Fuel Terminals
• Corrosion control • Transportation safety • Loading/unloading of trucks, railcars, pipelines • Laboratories
Product Description
The petrochemical, gas processing, & gas pipeline industry has for many years required an accurate,
dependable, low maintenance, and cost effective sulfur analyzer for quality and laboratory purposes.
With over twenty years of experience in developing and manufacturing sulfur analyzers and associated
parts and supplies, Analytical Systems International has met these requirements with a unique & proven
microprocessor based analyzer, which provides analysis based on the only absolutely specific lead ace-
tate principal of operation. The Model 856-150 system measures H2S & total sulfur by hydrogenation,
similar to that as described in ASTM Method D3031, D4084-82, D4468-85, & 4045-81. The sulfur sample
is precisely metered into a continuous flowing stream of hydrogen gas. The sample and hydrogen are
heated in the furnace resulting in thermal cracking of the sulfur which are reduced to short chain hydro-
carbons. These reactions result in the formation of H2S. After complete humidification of the sample the
H2S comes in direct contact with the lead acetate tape which produces a darkening of lead sulfide
immediately measured by the photodiode/LED optics & rate-of-reaction digital electronics to provide
an accurate and reproducible total sulfur and H2S analysis with PPB or PPM. The LCD display provides
the current reading, any alarm condition, procedure prompts (such as calibration procedure), and failure
indicators (is offered). Quality materials are selected for their compatibility and are utilized throughout
fabrication. Special attention is given to wetted parts that come in contact with the process
stream and are selected to be non-reactive with H2S/Sulfur.
www.LiquidGasAnalyzers.com
Typical Specifications
DISPLAY WEIGHT
- Alpha Numeric LCD - ~100 lbs.
- 128 x 64 pixel
- Back-lit display DIMENSIONS
- 20” x 22” x 10”
TEMPERATURE RANGES
- 1°C to 50°C (operating) UTILITIES/SETTINGS
- 0°C to 70°C (storage) - 110VAC or 220VAC
- 50 Watts normal, 350 Watts max.
ANALOG - Carrier Air/Gas: 180 ml/min (15 psig max)
- 4-20mA Isolated or none with optional Carrier Air Pump System
ENCLOSURE
- Bench top
- High grade aluminum
- Industrial powder coating
Analytical Systems Keco provides design and application engineering assistance for the User’s
analyzer requirements. For a quotation, please complete Analyzer Quote Request Form at
www.LiquidGasAnalyzers.com/quote
Analytical Systems Keco reserves the right to make revisions and or changes without notice. Analytical Systems shall not be liable for any
errors or omissions made or any damages resulting from the use of the analyzer, information, or the manual. © 2015 Printed in the USA.