TOTAL SULFUR LABORATORY ANALYZER

Model 856-51| For liquid and gas samples

Product Features
• ASTM method references

• Specific to sulfurs only. No false positives, ever

• No routine calibrations required

• Quantitative measurement in PPB, PPM & higher

• Direct read LCD display

• Fault Diagnostics option

• Single LED light source & detector

• Requires only 4-6 tape rolls per year

Applications
• Naphtha • Dirty/clean Water • Diesel • Fuel Oil • Drilling Fluid • Condensate • Quality control • Fuel Terminals
• Corrosion control • Transportation safety • Loading/unloading of trucks, railcars, pipelines • Laboratories

Product Description
The petrochemical, gas processing, & gas pipeline industry has for many years required an accurate,
dependable, low maintenance, and cost effective sulfur analyzer for quality and laboratory purposes.
With over twenty years of experience in developing and manufacturing sulfur analyzers and associated
parts and supplies, Analytical Systems International has met these requirements with a unique & proven
microprocessor based analyzer, which provides analysis based on the only absolutely specific lead ace-
tate principal of operation. The Model 856-150 system measures H2S & total sulfur by hydrogenation,
similar to that as described in ASTM Method D3031, D4084-82, D4468-85, & 4045-81. The sulfur sample
is precisely metered into a continuous flowing stream of hydrogen gas. The sample and hydrogen are
heated in the furnace resulting in thermal cracking of the sulfur which are reduced to short chain hydro-
carbons. These reactions result in the formation of H2S. After complete humidification of the sample the
H2S comes in direct contact with the lead acetate tape which produces a darkening of lead sulfide
immediately measured by the photodiode/LED optics & rate-of-reaction digital electronics to provide
an accurate and reproducible total sulfur and H2S analysis with PPB or PPM. The LCD display provides
the current reading, any alarm condition, procedure prompts (such as calibration procedure), and failure
indicators (is offered). Quality materials are selected for their compatibility and are utilized throughout
fabrication. Special attention is given to wetted parts that come in contact with the process
stream and are selected to be non-reactive with H2S/Sulfur.

Phone (281) 516-3950 or (281) 664-2890


Sales@asikeco.com | service@asikeco.com

www.LiquidGasAnalyzers.com
Typical Specifications
DISPLAY WEIGHT
- Alpha Numeric LCD - ~100 lbs.
- 128 x 64 pixel
- Back-lit display DIMENSIONS
- 20” x 22” x 10”
TEMPERATURE RANGES
- 1°C to 50°C (operating) UTILITIES/SETTINGS
- 0°C to 70°C (storage) - 110VAC or 220VAC
- 50 Watts normal, 350 Watts max.
ANALOG - Carrier Air/Gas: 180 ml/min (15 psig max)
- 4-20mA Isolated or none with optional Carrier Air Pump System

ANALYTICAL PERFORMANCE AREA CLASSIFICATIONS


- Resolution: 1 ppb - General purpose for non-hazardous areas
- Accuracy: ±2% - Laboratory environments
- Repeatability: ±2%
- Linearity:±1% AVAILABLE OPTIONS
- Drift: Nil - Diagnostic/fault relay alarms
- Temp. Coefficient: 0.01% / °C - RS-232/485 Modbus
- Analysis time: 0.75 Second - Data Logger for data download to PC
- Modem communications
DETECTION RANGES
- Customer specified (contact factory) TECHNOLOGIES
including low ppb, ppm and percent ranges - Rateometric-Colorimetric Tape technology

ENCLOSURE
- Bench top
- High grade aluminum
- Industrial powder coating

Analytical Systems Keco provides design and application engineering assistance for the User’s
analyzer requirements. For a quotation, please complete Analyzer Quote Request Form at
www.LiquidGasAnalyzers.com/quote
Analytical Systems Keco reserves the right to make revisions and or changes without notice. Analytical Systems shall not be liable for any
errors or omissions made or any damages resulting from the use of the analyzer, information, or the manual. © 2015 Printed in the USA.

You might also like