Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Tec-5500 05

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Defibrillation with AED

High performance to satisfy your needs


In 1966, Nihon Kohden manufactured Japans first direct current defibrillator. From our long experience in this field, we provide reliable solutions for all defibrillator needs.

Major options
For full list of options and consumables, see theTechnical Data separately available

Defibrillator
TEC-5521K TEC-5531K

Compact & High performance


Biphasic, AED & SpO2/CO2 monitoring

ActiBiphasic
TEC-5500K series provides low energy biphasic waveform defibrillation. Biphasic waveform defibrillation requires lower energy than conventional monophasic defibrillation and causes less damage to myocardium. Biphasic technology demonstrates superior results to save the patient from sudden cardiac arrest. Nihon Kohdens unique ActiBiphasic* technology provides an improvement over most conventional biphasic circuits by employing an original T-circuit. In conventional biphasic circuits, when impedance is high, the pulse width becomes wider which reduces the efficiency of defibrillation. Nihon Kohdens T-circuit actively controls the shape of the second phase waveform to maintain *Patent pending constant pulse width.

DSI interface unit, QI-552V, for SpO2 and CO2 (photo) DSI/AUX out interface unit, QI-553V, for SpO2 or CO2 and AUX

SpO2 adapter, Y090 JL-951T3 Reusable SpO2 probe BluPRO, P225F TL-201T

Defibrillator analyzer, AX-103VK

Cart, KD-028A Tray for cart, DI-001A

CO2 sensor kit, P906 TG-901T3 Airway adapter, R801 YG-101T Disposable SpO2 probe BluPRO, P203A TL-271T, P203B TL-272T, P203C TL-273T, P203D TL-274T

Battery charger, SB-551V

AED with voice prompt


AED (Automated External Defibrillation) is available with disposable pad adaptor cable (option) and disposable pads. When shockable rhythm is detected, TEC-5500K automatically starts charging for hands-free defibrillation. CPR timing sound is also provided. Voice prompt is available as standard provision for less frequent users.
Internal paddle electrode ND-762V/763V/764V/765V/766V/ 767V Available in six sizes (25, 35, 45, 55, 65, 75 mm dia) CO2 sensor kit, P908 TG-921T3 Disposable naso-oral adapter, for non-intubated, V922 YG-121T V923 YG-122T Airway adapter for P908, for intubated R804 YG-111T

Rechargeable battery, X065 NKB-301V

Gel holder kit, YZ-025H0

SD card , QM-064D Y154 Defibrillation report viewer software, QP-551VK

SpO2/ CO2 monitoring (option)


You can easily add measuring parameters of SpO2 and CO2 with an optional unit. 2 waveforms can be displayed simultaneously on a crisp TFT color LCD screen.

Disposable pads Adult H315 P-510 Child H316 P-512 Disposable pad adaptor cable JC-765V

Pediatric electrode assy, ND-612V, 44 mm dia

This brochure may be revised or replaced by Nihon Kohden at any time without notice.

TEC-5531K (shown with options)

5226

CAT.No.55-053B 07.06. SZ. AO.

Printed in Japan on Recycled Paper

Fast and Reliable Defibrillation with ActiBiphasic technology


No waiting time for defibrillation
Fast charging 3 seconds for 200J, 5 seconds for 270J charging in AC operation or fully charged new battery. Quick recovery 3 seconds ECG recovery shows the defibrillation result quickly.

Compact and lightweight


Easy to carry in an emergency

User-oriented unique designs


Inclined design
The paddle holder is slightly inclined for easier placing and removing of the paddles. Screen and operation panels are also inclined for easier viewing from a standing position.

Reliable and stable operation


Protection from sudden capacitor failure The high voltage capacitor is divided into thousands of individual cells to prevent sudden, total failure of the capacitor. If any part fails, the remaining cells can still provide shock. The high-voltage capacitor is automatically tested by a capacitor test program which measures the capacitance by charging and discharging. Reliable battery operation

Review and reporting


Saved data can be transferred to a PC using an optional SD memory card , and reviewed on the PC with optional Defibrillation Report Viewer software, QP-765VK/551VK. Recorded voice can be replayed on the PC with QP-551VK.

Practical external paddles


The paddles include child electrodes underneath the adult electrodes. Electrode-skin contact quality is indicated by easy to see colorcoded indicators. TEC-5521K (with optional unit)

Powerful battery operation


High capacity
A fully charged new battery provides at least 70 discharges at 270J or 150 minutes continuous monitoring.*
(*see Technical Data for specific conditions)

Voice recorder
Voice and ECG waveform at the defibrillation can be saved in the optional SD memory card. You can replay on PC or TEC-5500K series defibrillator what happened and what was done.

Convenient paddle rest


Convenient paddle rests for temporary storage of prepped external paddles.

Easy paddle change


You can change paddles easily with one connector.

Short charging time


Approx. 2 hours (maximum 3 hours) to fully charge with AC cord connected and power off.

An optional NiMH (nickel metal hydride) rechargeable battery provides reliable battery operation. A new real load testing method indicates the actual remaining charge so you can know approximately how many defibrillations are available. Battery performance test is done by simulating actual charging and discharging to accurately test the quality of the rechargeable battery.

Easy routine checking You can easily check the instrument at any time.

Airway management with CO2 mainstream method on capONE (option)


cap-ONE, the worlds first mainstream CO2 sensor, can measure EtCO2 of non-intubated patients. It can also measure intubated patients just by changing the airway adapter. No complicated setting or warm-up time is required so you can obtain CO2 quickly and accurately. A CO2 sensor kit, TG-901T3, is also available for intubated patients.

Built-in recorder
2-channel built in thermal array recorder records various defibrillation information. Defibrillation report

Noninvasive pacing (TEC-5531K)


External pacing capabilities are built-in. Pacing is very effective for recovery from bradycardia after defibrillation.

Trend report

You might also like