Hazardous > Armoured > Double Compression > OS-E1UF

OSCG EXPLOSION PROOF CABLE GLAND

Certificates

OS-E1UF Classifications

Design Specification BS 6121, IEC 62444, EN 50262

Application Compliance Standard


ATEX Certification
IEC/EN 60079-0, 1, 7, 31
Presafe 17 ATEX 11456X
: Any Type of Armoured Cable IECEx Certification IECEx PRE 17.0063X
KCs Certification 18-KA2BO-0212~9X, 18-KA2BO-0236~9X
TR CU Certification RU C- KR.AA87.B.01105
For use with any type of armoured cable
PESO Certification P465223
Outdoor & Indoor use
CCC Certification 2020332313000759
Flameproof & Increased Safety
INMETRO Certification DNV 21.0149X
EMC cable gland. (360˚ contact) - EMC tested
Code of Protection II2G Ex db IIC Gb, Ex eb IIC Gb, II2D Ex tb IIIC Db
Reduce the effect of coldflow characteristics
Operating Temperature -60˚C ~ 110˚C
Double compression
Zone 1,2 & 21,22, Gas Group IIA, IIB, IIC,
Regulation Dust Group IIIA, IIIB, IIIC

Ingress Protection (Metric) IP 66 / 68 (request in advance if IP68 required)


(NPT) NPT tapered hole : IP66
IP68(apply non-hardensing grease)
Clearance hole : IP66/68(using IP Washer)
Applicable Cable Specification All types of armoured cable
Nickel plated brass(standard),
Gland Material
Brass(only), Stainless steel(316L), Aluminum
Gasket (washer) Nylon(Standard), PTFE-Teflon(Option)
Packing Silicone

Accessories (optional) Lock nut, Sealing washer, Earth tag, Shroud,


Serrated washer

Order Example BS 6121 Type of Gland


(The suffix for each type of protection)
Part No. Thread Material Accessories
Single wire armoured W
Lock nut, Sealing washer, Earth tag, Wire amoured Braid amoured
OS-E1UF 20 M20 Nickel plated brass
Serrated washer, Shroud Wire braided X Position Position

To Entry
Optional Thread Length : ≥15mm ( Standard : M16 ~ M63 Length 15mm, M75 Length 20mm, Aluminium strip armoured Y
M90 ~ M115 Length 25mm)
Material for accessories is required Double steel tape armoured Z
Other than IECEx, ATEX and KCs marking, the marking requirement must be informed
when ordered.
(* in mm)
Thread Length(ℓ)
Part No. Entry Thread Size(M) Cable Dia Armour Size
- Min Hexagon Weight Length
(Gland Size) Dimensions (g) (L)
Metric NPT Option Metric NPT Option Inner 'A' Outer 'B' Wire Braid

OS-E1UF 16 M16 1/2" M20 15 15 15 5 ~ 11.5 9 ~ 15.5 0.9 ~ 1.25 0.05 ~ 0.8 H25 x P27 137 56

OS-E1UF 20 M20 1/2" 3/4" 15 15 16 7.5 ~ 15.2 13.2~20.5 0.9 ~ 1.25 0.05 ~ 0.8 H31 x P34 212 63

OS-E1UF 25 M25 3/4" 1" 15 16 18 13 ~ 19.6 17 ~ 26 1.25 ~ 1.6 0.05 ~ 0.8 H37 x P40 325 68

OS-E1UF 32 M32 1" 1-1/4" 15 18 19 16.5 ~ 26.2 24 ~ 33.5 1.6 ~ 2.0 0.05 ~ 1.2 H47 x P50 570 75

OS-E1UF 40 M40 1-1/4" 1-1/2" 15 19 21 23 ~ 32.3 30 ~ 41.5 1.6 ~ 2.0 0.05 ~ 1.2 H56 x P60 876 83

OS-E1UF 50 M50 1-1/2" 2" 15 21 24 29 ~ 41.5 38 ~ 50 1.8 ~ 2.5 0.05 ~ 1.2 H70 x P75 1445 89

OS-E1UF 63 M63 2" 15 24 39 ~ 50 45 ~ 60 1.8 ~ 2.5 0.05 ~ 1.2 H77 x P82 1740 98

OS-E1UF 63X M63 2-1/2" 15 27 46 ~ 55 55 ~ 66 1.8 ~ 2.5 0.05 ~ 1.2 H82 x P88 1907 98

OS-E1UF 75 M75 2-1/2" 20 27 52 ~ 61 58 ~ 72 1.8 ~ 2.5 0.05 ~ 1.2 H92 x P100 3270 109

OS-E1UF 75X M75 3" 20 30 59 ~ 67 66.1 ~ 79 1.8 ~ 2.5 0.05 ~ 1.2 H98 x P106 2912 109

OS-E1UF 90 M90 3" 3-1/2" 25 30 32 66 ~ 80 72 ~ 90 1.8 ~ 3.0 0.05 ~ 1.6 H110 x P120 4600 111

OS-E1UF 100 M100 3-1/2" 4" 25 32 32 76 ~ 90.5 84 ~ 101.5 1.8 ~ 3.0 0.05 ~ 1.6 H125 x P135 5500 123

OS-E1UF 115 M115 4" 25 32 88 ~ 102 100 ~ 116 1.8 ~ 3.0 0.05 ~ 1.6 H135 x P143 5500 123

※ The entry holes need not greater than 0.7mm ※ Up to M75, 1.5 pitch is standard and from M90, 2.0 pitch is standard 19