Continuous One Way Slab
Continuous One Way Slab
Continuous One Way Slab
4 Thickness of Supports
End supports 0.3 m
Interior Supports 0.24 m
8 Design Factors
xumax/d 0.48 N.A. factor 𝑋𝑢𝑚𝑎𝑥/𝑑=700/(1100+0.87∗𝑓𝑦)
Qlim 2.76 M.R. factor
ptlim 0.96 % R/F
9 Effective Length
For end span Lx 3.31 m
Ly 6.8 m
For interior span Lx 3.59 m
Ly 6.8 m
10 Approximation of depth
MF 1.5 "Assuming Pt = 0.35%, from Figure 4, Page 38, IS 456(2000)"
dassumed 100 mm
φ 10 mm
Dassumed 130 mm
11 Total Factored load calculation(w)
S.Wt. 3.25 kN/m2
F.F. 1.5 kN/m2
L.L. 2 kN/m2
Load type
Location
1 2 Sum (Mu) 𝑀𝑢=𝐶𝑜𝑒𝑓𝑓𝑖𝑐𝑖𝑒𝑛𝑡𝑠∗𝑊𝑑∗ 〖𝑙 _𝑒𝑓𝑓 〗 ^2
A 5.854 2.958 8.81 kNm
C -7.025 -3.287 -10.31 kNm
B 5.300 2.976 8.28 kNm
D -7.067 -3.968 -11.03 kNm
For calculation of required effective depth, maximum design B.M. is to be considered without considering sign.
dprovided Err:508 mm
Dprovided Err:508 mm
Ast Spacing Spacing Spacing Ast Ast min 𝐴_𝑠𝑡=(0.5∗𝑓_𝑐𝑘∗𝑏𝑑)/𝑓_𝑦 ×{1− √([1−(4.6∗𝑀_𝑢∗10^6
Location 3d(mm)
Sum (Mu) required Dia of bars req(mm) (mm) provided provided (0.12%)
A 8.812 258.001 8 194.827 300 194.827 190 264.555 156.000
B 8.276 241.428 8 208.200 300 208.200 200 251.327 156.000
Spacing required
s 257.7717 mm c/c
5d 500 mm c/c
450 mm c/c
S.F. Coefficients
For Members of the uniform cross section which supports uniformly distributed load over 3 or mor
which do not refer by more than 15% of the longest, B.M. and S.F. used in design may be obtained
coefficients from these tables.
Support Moments
At other Interior At end
support support
D O
-0.083 0
-0.111 0
At all other
Interior
supports
H
0.5
0.6