Design of Two Way Slab by Limit State Method
Design of Two Way Slab by Limit State Method
Design of Two Way Slab by Limit State Method
1 Data
Longer span of slab, ly 6m
Shorter span of slab, lx 4.175 m
Materials used
Concrete M20 20 N/mm2
Steel Fe500 500 N/mm2
2 Effective span
Longer span of slab, ly 5.825 m
Shorter span of slab, lx 4m
ly/lx 1.45625
type of slab <2 two way slab
Support Condition :
Interior Pannels
3 Calculation of loads
i) Dead load
i Slab thickness 125 mm
Self weight of concrete 25 KN/m3
Dead load of slab = 25 * 0.125 3.125 KN/m2
ii Screeding thickness 30 mm
Self weight of screeding 20.4 KN/m3
Dead load of screeding = 20.4 * 0.03 0.612 KN/m2
iii marble flooring thickness 19 mm
Self weight of marble 27 KN/m3
Dead load of marble = 27 * 0.019 0.513 KN/m2
iv Cement plaster thickness 12.5 mm
Self weight of plaster 20.4 KN/m3
Dead load of plaster = 20.4 * 0.0125 0.255 KN/m2
Total dead load on slab 4.505 KN/m2
4 Calculation of moments
As per code, Shorter Direction Longer Direction
-ve moment at support Support, αx1 0.052125 Support, αy1 0.032
+ve moment at mid mid, αx2 0.040125 mid, αy2 0.024
Along shorter span,
Mx = αx1*wu*lx 12.992 KNm
My = αy1*wu*lx 7.976 KNm
Along longer span,
Mx = αx2*wu*lx 10.001 KNm
My = αy2*wu*lx 5.982 KNm
5 Depth Calculation
Minimum depth of slab is calculated considering maximum bending moment
Maxm bending moment 12.992
Depth required,
d=sqrt(Mu/(0.36*xumax/d)*(1-0.42*xumax/d)*b*fck)
6 Reinforcement Calculation
provide the reinforcement of dia 10 mm
S. Shorter Direction Longer Direction
N Description
o. Support mid Support mid
1 αx & αy 0.052 0.040 0.032 0.024
2 BM 12.99 10.00 7.98 5.98
3 Ast required 290.71 220.00 173.52 128.78
4 Ast min 150.00 150.00 150.00 150.00
5 Spacing reqd 270.27 357.14 452.80 523.81
6 Spacing prov. 150.00 150.00 150.00 150.00
7 Ast provided 523.81 523.81 523.81 523.81
8 % of steel provided 0.42 0.42 0.42 0.42
7 Check
7 Minimum reinforcement
Min Ast = 0.12% bD 150 mm2 < Ast provided in all
sections
7 Check for deflection
From deflection control criteria
lx/d < (l/d)basic*αβγ where
lx/d 36.3636363636364
α = modification factor for tension reinforcement fig 4
β = modification factor for compression reinforcement 1 fig 5
γ = reduction factor for ratios of span to effective depth in flanged 1 fig 6
beam
(l/d)basic = 26 IS 456
For α,
fs = 0.58*fy*(Ast required/Ast provided) 121.800 N/mm2
% of tensional reinforcement 0.419
α 2
now, (l/d)basic*αβγ 52 OK Safe
Since, lx/d < (l/d)basic*αβγ SAFE
8 Results
Overall depth of slab = 125 mm
Main bar along short span at support 10 mm φ @ 150mm c/c
Main bar along short span at mid 10 mm φ @ 150mm c/c
Main bar along long span at support 10 mm φ @ 150mm c/c
Main bar along long span at mid 10 mm φ @ 150mm c/c