Annex to declaration of accreditation (scope of accreditation)

Normative document: EN ISO/IEC 17025:2017


Registration number: L 020

of KEMA B.V.
High Power Laboratory and High Voltage Laboratory

This annex is valid from: 01-02-2023 to 01-04-2026 Replaces annex dated: 23-06-2022

Location(s) where activities are performed under accreditation

Head Office

Klingelbeekseweg 195
6812 DE
Arnhem
The Netherlands

Location Abbreviation/ location code


Klingelbeekseweg 195 ARN
6812 DE Arnhem
The Netherlands

No. Material or product Type of activity1 Internal reference Location


number

Dielectric test
Power-frequency voltage test (AC)
1. Electrical equipment ISI-GSA-1227 ARN
(≤ 900 kV, 45-500 Hz)
DC voltage test
2.
(≤ 800 kV)
Lightning impulse voltage test (LI)
3.
(≤ 2,4 MV)
Switching impulse voltage test (SI)
4.
(≤ 2,0 MV)
5. Electrical equipment Test under wet conditions (AC / DC / LI / SI) ISI-GSA-1227 ARN
Partial discharge measurement
6.
(all above noise level)
Radio interference voltage measurement
7.
(all above noise level)

This annex has been approved by the Board of the


Dutch Accreditation Council, on its behalf,

J.A.W.M. de Haas

1
If there is a referral to a code starting with NAW, NAP, EA or IAF, this concerns a scheme mentioned on the RvA-BR010-lijst.
If no date or version number is mentioned for a normative document, the accreditation concerns the most current version of the document or scheme.
Dutch Accreditation Council RvA Page 1 of 6
Annex to declaration of accreditation (scope of accreditation)
Normative document: EN ISO/IEC 17025:2017
Registration number: L 020

of KEMA B.V.
High Power Laboratory and High Voltage Laboratory

This annex is valid from: 01-02-2023 to 01-04-2026 Replaces annex dated: 23-06-2022

No. Material or product Type of activity1 Internal reference Location


number

8. Tan δ and capacitance measurement


Impulse puncture test / Steep front-of-wave
9.
flashover test
(≤ 400 kV)
Corona measurement
10.
(any visible corona)
Short-circuit test
Short-time withstand current and peak
11. Electrical equipment ISI-GSA-1227 ARN
withstand current test
(≤ 1200 kApeak)
Ability to withstand short circuit / Short-circuit
12.
current tests / Short-time current tests
(≤ 1200 kV and ≤ 400kA)
Short-circuit making and breaking tests /
13.
Interruption tests / Terminal fault test
(≤ 1200 kV and ≤ 400kA)
Breaking tests / Interruption tests / Time
14.
current tests on fuses
(≤ 245 kV and ≤ 400kA)
Inrush current withstand test / Discharge
15.
current test
(≤ 600kV and ≤ 200kA)
Short-line fault tests
16.
(≤ 1200 kV and ≤ 400kA)
Out-of-phase making and breaking tests
17.
(≤ 1200 kV and ≤ 400kA)
By-pass making and insertion tests
18.
(≤ 1200 kV and ≤ 400kA)
Time current tests on autorecloser
19.
(≤ 400kA)
Internal arc fault tests / Internal fault test
20.
(≤ 1200 kV and ≤ 400kA)
Power arc test on insulators
21.
(≤ 400kA)
Short-circuit tests on arrester
22.
(≤ 400kA)

Dutch Accreditation Council RvA Page 2 of 6


Annex to declaration of accreditation (scope of accreditation)
Normative document: EN ISO/IEC 17025:2017
Registration number: L 020

of KEMA B.V.
High Power Laboratory and High Voltage Laboratory

This annex is valid from: 01-02-2023 to 01-04-2026 Replaces annex dated: 23-06-2022

No. Material or product Type of activity1 Internal reference Location


number

Switching test
Switching making and breaking test
23. Electrical equipment ISI-GSA-1227 ARN
≤ 1200 kV
Capacitive current switching tests
24.
≤ 1200 kV
Bus-transfer current switching tests
25.
≤ 1200 kV
Induced current switching tests
26.
≤ 1200 kV
Bus-charging current switching tests
27.
≤ 1200 kV
Inductive load switching tests
28.
≤ 1200 kV
Verification of coordination with short-circuit
29.
protection device
≤ 1200 kV
30. Minimum tripping current test

Accuracy test

31. Electrical equipment Tests for accuracy of instrument transformers ISI-GSA-1227 ARN
(incl. LPIT’s)
(CT: continuous current ≤ 60 kA, 50-60 Hz)
(CT: transient current ≤ 400 kA)
(VT: ≤ 500 kV, 50-60 Hz)

32. Measurement of voltage ratio and check of


phase displacement on power transformers
and reactors

Environmental- and temperature test


Climatic and environmental tests, ageing test,
33. Electrical equipment ISI-GSA-1227 ARN
(-40 ˚C to +60 ˚C, 50-99% rel. humidity)

34. Condensation test / Salt fog test / Tracking


and erosion test
Pollution test
35.
(≤ 350 kV)

36. Temperature cycle test / Thermal shock test /


Immersion test

Dutch Accreditation Council RvA Page 3 of 6


Annex to declaration of accreditation (scope of accreditation)
Normative document: EN ISO/IEC 17025:2017
Registration number: L 020

of KEMA B.V.
High Power Laboratory and High Voltage Laboratory

This annex is valid from: 01-02-2023 to 01-04-2026 Replaces annex dated: 23-06-2022

No. Material or product Type of activity1 Internal reference Location


number

37. Electrical equipment Heating cycle test / Heating cycle voltage test ISI-GSA-1227 ARN
/ Long term stability test / Long duration test
Temperature-rise test / Continuous current
38.
test /
thermal stability test
(≤ 25 kA, three-phase)
(≤ 50 kA, single-phase)

Material test

39. Electrical equipment Porosity test porcelain on insulators ISI-GSA-1227 ARN

40. Water absorption test on insulators


Water penetration test on cables
41.
(≤ 3 bar)

42. Galvanizing test

Mechanical test
Pressure withstand test for gas-filled
43. Electrical equipment ISI-GSA-1227 ARN
compartments
(≤ 20 bar)
Tensile test / mechanical test /
44.
(electro-)mechanical failing load test /
verification of the locking system
(≤ 500 kN)
45. Impact test
(Insulators: ≤ 10 Nm)
(Cable accessories)
Mechanical endurance/operation tests at
46.
ambient temperature / Low- and High-
temperature tests
(-40˚C to +60˚C)
Operation during the application of rated
47.
static mechanical terminal loads
(≤ 1000 kN)
Thermal-mechanical performance test on
48.
insulators
(≤ 300 kN; -50˚C to +70˚C)
49. Test to verify the proper functioning of the
position-indicating device

50. Mechanical shock tests on fuses

Dutch Accreditation Council RvA Page 4 of 6


Annex to declaration of accreditation (scope of accreditation)
Normative document: EN ISO/IEC 17025:2017
Registration number: L 020

of KEMA B.V.
High Power Laboratory and High Voltage Laboratory

This annex is valid from: 01-02-2023 to 01-04-2026 Replaces annex dated: 23-06-2022

No. Material or product Type of activity1 Internal reference Location


number

51. Electrical equipment Striker operation tests on fuses ISI-GSA-1227 ARN

52. Cantilever load- and internal pressure test on


insulators

53. Mechanical test on instrument transformers

54. Bending tests on cables

Resistance and impedance measurement

55. Electrical equipment Resistance measurement ISI-GSA-1227 ARN

56. Impedance measurement

57. Measurement of blocking impedance

Verification of degree of protection


Verification of the IP coding
58. Electrical equipment ISI-GSA-1227 ARN
(≤ IP56)
59. Mechanical impact test
(IK07-IK10)

Tightness and leakage test

60. Electrical equipment Tightness tests / Gas Tightness test / Leak ISI-GSA-1227 ARN
test of tightness test / Enclosure tightness
test

Sound level measurement

61. Electrical equipment Sound level measurement ISI-GSA-1227 ARN

Power measurement

62. Electrical equipment Power measurement ISI-GSA-1227 ARN

SFRA measurement

63. Electrical equipment SFRA measurement ISI-GSA-1227 ARN

Examination

64. Electrical equipment Determination of dimensions / Gauging ISI-GSA-1227 ARN

Dutch Accreditation Council RvA Page 5 of 6


Annex to declaration of accreditation (scope of accreditation)
Normative document: EN ISO/IEC 17025:2017
Registration number: L 020

of KEMA B.V.
High Power Laboratory and High Voltage Laboratory

This annex is valid from: 01-02-2023 to 01-04-2026 Replaces annex dated: 23-06-2022

No. Material or product Type of activity1 Internal reference Location


number

65. Electrical equipment Verification of displacements on insulators ISI-GSA-1227 ARN

Material Testing Laboratory


ISI-GSA-1227
66. Electrical equipment Solar radiation ARN

67. Glow wire test ISI-GSA-1227 ARN

68. Determination of temperature of deflection ISI-GSA-1227 ARN


under load
temperature of 135 °C
pressure of 1,8 MPa

Dutch Accreditation Council RvA Page 6 of 6