RN series 008

The Best Solution for Power System


Uninterruptible
Power Supply

ICA

ICA

ICA

True On Line Sinewave Output


EMI /RFI Filter
With Power Factor Correction Circuit
50 Khz SMPS Design
Full Bridge IGBT Inverter
Electronic Output Short Circuit Protection
High Efficiency
High Reliability
Wide Input Voltage Range
Support Generator Input
Support Economic Operation Mode
Expandable Back Up Time
Audible and Visual Indicator
Communicate with Most LAN System and Stand Alone PC, Auto Save and Auto Shutdown
Auto Restart
Rack Mount 19”
Easy to Install
Technical Specication

MODEL RN1100C RN2100C RN3100C


Capacity (VA/Watts) 1000 / 900 2000 / 1800 3000 / 2700
INPUT
Phase Single phase & Ground
Rated voltage 200/208/220/230/240Vac
Voltage range 160 ~ 300Vac
Frequency range 40 ~ 70Hz (auto detect)
Power factor ≥0.99
Bypass high voltage point
230~264: setting the high voltage point in LCD from 230Vac to 264Vac (Default: 264Vac)
Bypass voltage range
Bypass low voltage point
170~220: setting the low voltage point in LCD from 170Vac to 220Vac (Default: 170Vac)
ECO range Same as bypass
Generator input Support
OUTPUT
Output voltage 200/208/220/230/240Vac
Power factor 0.9
Voltage regulation ±1%
Line Mode 47~53Hz (for 50Hz) or 57~63Hz (for 60Hz)
Frequency
Bat. Mode 50/60 (±0.01)Hz
Crest factor 3:1
≤3% with linear load
Harmonic distortion (THDv)
≤6% with non-linear load
Waveform Pure Sinewave
Efciency (AC mode full load) >88% >92%
BATTERY
Battery voltage 24Vdc 48Vdc 72Vdc
Typical recharge time 4 hours (to 90% of full capacity)
Backup time 10 minutes (depending on load)
Charge current 1A
SYSTEM FEATURES
Transfer time Utility to Battery: 0ms; Utility to Bypass: <4ms
105%~110%: UPS transfer to bypass after 10 minutes when the utility is normal
Ambient Temp. 110%~130%: UPS transfer to bypass after 1 minute when the utility is normal
<350C 130%~150%: UPS transfer to bypass after 5 seconds when the utility is normal
Overload >150%: UPS transfer to bypass immediately when the utility is normal
@350C
105%~110%: UPS transfer to bypass after 1 minute when the utility is normal
350C < Ambient
110%~130%: UPS transfer to bypass after 5 secondse when the utility is normal
Temp.
>130%: UPS transfer to bypass immediately when the utility is normal
Short circuit Hold Whole System
Overheat Line Mode: Switch to Bypass; Backup Mode: Shutdown UPS immediately
Battery low Alarm and Switch off
EPO (optional) Shutdown UPS immediately
Audible & visual alarm Line Failure; Battery Low, Overload, System Fault
Communication interface USB (or RS232), SNMP card/ relay card (optional)
ENVIRONMENTAL
Operating temperature 0 ~ 40 0C
Storage temperature -25 ~ 55 0C
Humidity range 20 ~ 90% (non-condensing)
Altitude <1500m
Noise level <50dB at 1 meter
PHYSICAL
Dimensions W x H x D (mm) 440 x 86.5 x 325 440 x 86.5 x 435 440 x 86.5 x 600
Net weight (kg) 11.5 19.6 26.7
Gross weight (kg) 14.1 22.4 29.9
STANDARDS
Safety IEC/EN62040-1, IEC/EN60950-1
IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC6100-4-5,
EMC
IEC61000-4-6, IEC61000-4-8
Specication are subject to change without prior notice.