Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

ASIN Aqua Home Manual

Download as pdf or txt
Download as pdf or txt
You are on page 1of 48

USER MANUAL

ASIN AQUA Home


®
EN

CLF, REDOX, OXY

CUTTING EDGE TECHNOLOGY


FOR CRYSTAL CLEAR AND HEALTHY POOL WATER

INTEGRATED
VS PUMP
CONTROL

www.asekopool.com
General safety information
This user manual contain basic information that should be observed during assembly, start-up,
operation, and maintenance. Therefore, this user manual must be read by installers and operators
prior to assembly and start/up, and must be accessible to every user of this unit. Additionally, all
further safety information in this document must be observed. Read and follow all instructions. In
order to minimize the danger of injury, do not allow children to use this product. Non-compliance
with safety information can result in hazards to persons, the environment and the equipment.
Non-compliance with safety information will result in a forfeit of any potential right to damage
compensation.

Insufficient personnel qualification


Hazards in the event of insufficiently qualified personnel, potential consequence: Injury, heavy material
damage.

• The system operator must ensure compliance with the required qualification level.
• Any and all work may only be performed by correspondingly qualified personnel.
• Access to the system must be prevented for insufficiently qualified persons, e.g. via access codes
and passwords.

Potential overdosing of chemical agents


Despite ASIN Aqua® comprehensive safety functions, it is possible that a probe failure and other errors
could lead to an overdosing of chemical agents. Potential consequence: Injury, heavy material damage.

• Design your installation such that uncontrolled dosage is not possible in the event of a probe failure
or other errors, and/or such that uncontrolled dosage is recognized and halted before damage is
incurred.
• Uncontrolled overdose of chemicals can cause harm to health and property. Even though the device
contains a number of security elements can not be ruled out that in case of failure of the measuring
probes, or the whole device may result in overdose of chemical agents. Install the equipment so
that uncontrolled overdose of chemicals was not possible and that uncontrolled overdose has been
detected in time before causing any harm. It is necessary to use chemicals in such quantities that an
overdose will not cause dangerous concentration of chemical agents. Do not use chemicals in too
large packages or with too high concentration.

Gaseous chlorine produced from dosing in standing water if dosing


outputs are not closed via the filter pump
If the flow switch is stuck or experiences another error, there is a risk of dosing into standing water.
Poisonous chlorine gas can be yielded when sodium hypochlorite and pH minus come together.

Non compliance with informational text


Not observing informational text may lead to hazards. Potential consequence: gravest degree of injury,
heavy material damage.

• Read all informational text carefully.


• Cancel the process if you are unable to exclude all potential hazards.

2 EN
Use of new functions
Because of the continued development, a ASIN Aqua® unit may contain functions, which are not
completely described in this version of the user manual. The use of such new or extended functions
without a profound and secure understanding by the operator may result in malfunctions and severe
problems. Potential consequence: Injury, heavy material damage.

• Make sure to get a profound and secure understanding of a function


and relevant boundary conditions, before you start to use it.

• Check for an updated version of the user manual or additional


documentation available for the relevant functions.

• Make use of the integrated help function of the ASIN Aqua® to get
detailed information on functions and their parameter settings.

• In case it is not be possible to get a profound and secure understanding of a


function based on the available documentation, do not use this function.

Overdosing if pH value is wrong


If disinfection is enabled before the pH value is stable in the ideal range of 7.0 to 7.4, then it may lead
to heavy overdosing of chlorine or bromine. Potential consequence: Injury, heavy material damage.

• Do not start disinfection with chlorine until the pH value is


stable in the ideal range between 7.0 and 7.4.

Conditions before using


Make sure you have a newest and updated version of the user manual and other documentation for
all functions of the unit. Use and read the integrated help features. In case of not understanding the
information about certain features of the unit, do not use these features.

Handling chemicals for pool water treatment


The chemicals used with the ASIN Aqua must be handled in a safe manner to prevent damage or personal
harm. Aseko recommends you always use personal protective safety equipment when handling the pH
and chlorine agents. Refer to the Materials Safety Data Sheet (MSDS).

W A R N I N G : Never mix the pH agent with the chlorine agent. When carrying out maintenance on
the clear plastic tubes or valves always rinse with clean water to prevent mixing of the pH and chlorine
agents.

EN 3
What is in the box

Water thermometer with


housing #13192
Device
ASIN AQUA Home

Probe housing 2 pcs


#13013 Peristaltic pumps #12093

Flow detector with filter


#12106-1

CLF probe or Redox probe Long Life


pH probe Long Life
#12052 #12016
#12012
(only for ASIN AQUA HOME CLF) (only for ASIN AQUA HOME Redox)

Coagulation mixer Water valves 2 pcs Injection valve 4 pcs


#30001 #12006 #12005
(only for ASIN AQUA HOME OXY)

Suction tube weight 4 pcs Wrench socket for probes Dowels PE Tube 1/4” (6.35 mm)
#12023 #13046 and screws transparent 15m #12008

4 EN
Available optional accessories
Inserting DN50 plug Pressure-type level sensor External touch display
1/4” threaded #12134 #12086 #12048

Photometer pH 7.00 Buffer #12065 Redox Air thermometer


#13076 Buffer #12063 #13192

BESGO 5-way BESGO 3-way BESGO 4-way


#83103 #83130 #83150

ASEKO original chemical solution


20 l or 5 l volume
CHLORPURE #12075 OXY PURE #13038 pH MINUS #12130 pH PLUS #12120 ALGICID #12156 FLOC+C #12139
(only for CLF and Redox) (only for OXY)

Volume 10 kg Bottle 1 kg
BALANCER #13039 MAGNESIUM #13039 SUPER CHLOR #13120

EN 5
ASIN AQUA Home
ASIN AQUA Home is an advanced system for pool water treatment and
pool technology management. The pool water treatment with chlorine or
chlorine-free disinfection, precise pH management, boosted by dosing of
Algaecide and Flocculating aid assure the crystal-clear water of your pool by
use of the lowest necessary amount of chemical aids. The Pool Technology
Management functions automate the operations of your pool and minimize
the requirements for manual maintenance. The touchscreen display shows
all information about water quality and allows easy setup of the entire
system. With internet connectivity, you can monitor your pool parameters
through a mobile or web application.

MAX POOL VOLUME


250 m3

Pool water treatment


Balanced combination of treatment aids provide crystal
clear pool water

Chlorine control and dosing


Highly effective disinfection to use with the chlorine technology ASIN
AQUA HOME CLF and ASIN AQUA HOME Redox. Accurate measurement
in combination with the dosing algorithm maintain the required values of
disinfection while using the lowest necessary amount.

OXY Pure
Active oxygen for chlorine-free technology ASIN AQUA HOME OXY. Active
oxygen in the combination with precise pH management, dosing of algicide
and FLOC+C maintains clean and crystal-clear water without the use of
chlorine.

pH control and dosing


Acurate measuring by pH probe long-life in combination with the dosing
algorithm assures the required water quality. Dosing of pH MINUS or pH PLUS.

ALGICIDE dosing
The effective polymeric biocide protects water against algae, fungi, moulds
and bacteria.

FLOC+C dosing
FLOC+C contains flocculation and coagulation components. Its continual
dosing improves filtration capability of removing even the smallest impurities.
To increase the effectivness of FLOC+C use coagulation mixer.

6 EN
Pool technology Switching BOTTOM / OVERFLOW

management At the set times of the TIMER, water flows through the
OVERFLOW (the relay is activated).
Outside the set times of the TIMER, water flows through
Filtration Time Control the bottom drain (relay deactivated).
Daily, automatic start of the filtration system in individual- The pool cover does not affect the BOTTOM / OVER-
ly preset periods. FLOW switching.
During filter backwashing, water flows through the BOT-
Water Level - Refilling TOM DRAIN.
In case of an alarm LEVEL TOO HIGH the flow will be
System can be programmed to control four different
switched to OVERFLOW until the alarm level expires.
water levels at your pool and switch the water refilling
or automatically use the excessive water for filter This function requires optional 3-way Besgo valve.
backwash. Requires optional level sensor.
Pool cover position (relay closed)

Filter Backwashing If the pool cover is closed during the set TIMER times,
the speed of the VS pump will automatically change to 1
The system can control the filter backwash and set
(LOW).
specific time periods to perform the filter backwash
automatically. This function requires an optional 5-way
Besgo valve. Control by External touch display
ASIN AQUA can be monitored and controled by external
Smart Heating Control touch display (this function requires an optional External
touch display #12048).
The system is equipped by intelligent control of preset
water temperature. It can switch and control the heating
(solar heating, electrical heating, gas heating, Programmabel relay
heat exchanger) by logic of integrated smart heating ASIN AQUA has one integrated programmable relay to
functions. control an extra accessory.

Winter mode Solar heating control


The Winter mode ensures the pool remains at a safe ASIN AQUA monitors the temperature of solar panels.
temperature during cold weather conditions. When solar panels reach a set threshold, the water is
automatically redirected to the solar panels. This function
Variable speed pump control (VS pump)
requires an optional 4-way Besgo valve.
In the settings, select the type of your variable speed
pump. ASIN Aqua allows to use 4 speeds:
Speed ​​0 (OFF)
Speed ​​1 (LOW) for economical filtration outside the
filtration TIMER.
Speed ​​2 (MEDIUM) during filtration TIMER.
Speed ​​3 (HIGH) during filter backwash.

EN 7
ASIN AQUA Home Installation
The ASIN AQUA must be operated in indoor environment with a temperature
range of +5 to +40 °C, and the relative humidity must not exceed 70%. Direct
sunlight, high humidity, and dust may damage the ASIN AQUA.

• Before installing, ensure that pool water is chemically clean and without
40 °C
max.
CHLORINE pH ALGICID FLOCC
dirt.

5 °C
min.
Install the mounting rail and attach the ASIN AQUA to the wall. Choose a lo-
cation with a free space of at least 40 cm in all directions, and a height above
the floor must not be higher than 150 cm.

• The vertical distance between ASIN AQUA and the bottom of containers
must not exceed 2m.
40 cm • The maximum distance from injection valves to peristaltic pumps must
not exceed 8m.

RECOMMENDATION: Install the ASIN AQUA so that even in case of leak-


CHLORINE pH ALGICID FLOCC
age of chemicals from the pumps or pipes, there is no damage to other
equipment or spillage on the floor. Use drip trays.
40cm 40 cm Do not install any other devices under ASIN AQUA.
40 cm
WARNING: High relative humidity reduces the lifespan of electronic
150 cm components, particularly displays. If the ASIN AQUA is in an environment
with high relative humidity and low temperature (such as the installation
shaft, or garden house), keep the device permanently ON. The temperature
in the device will be higher than the ambient temperature, resulting in a
significant reduction of relative humidity within the device.
Wall bracket
This also applies when storing the unit during the winter.

18,5 cm 18,5 cm

CHLORINE pH ALGICID FLOCC

max 8 m
max 2 m

8 EN
Installing the Probes
1. Carefully insert the pH, CLF or REDOX probe into the housing.

2. Hand tighten or use the plastic wrench socket for probes.

3. To connect the probe tighten the connector on the probe connection


cable.

After probes have been inserted, slightly tightened and connectors have
been connected, ASIN AQUA Home is ready for connection to the water
system of your pool.

WARNING: Only hand tighten the probes or use the plastic wrench socket
for probes. Do not use pliers or steel wrench.

Step 1: Installation of pH probe pH Long Life probe


#12012

pH probe
housing #12013

Step 2: Installation of CLF or Redox probe


(only for ASIN AQUA Home CLF and Redox)

CLF probe Redox probe


#12052 Long Life Wrench socket for
#12016 probes #13046

CLF or Redox
probe housing
#12013

EN 9
FROM BOTTOM OUTPUT

FROM SKIMMER

INLET
3-WAY BESGO SAMPLING POINT

FLOWMETER

1
SUPPLY
WATER
MEASURED
3
OUTPUT 4

INLET

PUMP VS
COAGULATION MIXER
CHLORINE

WASTE
pH
ALGICID

5-WAY BESGO
FLOCC

FILTRATION

4-WAY BESGO
TO SOLAR

FROM SOLAR

2
DRAINAGE
WATER
MEASURED
HEATING

TO POOL
Pool Water Connection Measuring Water
valve #12005

Screw the measuring water valve in the glue head D50 with thread G1 / 4
“#12134, glued to the T-piece. Tighten the measuring water valve into
the head by hands only. Do not use pliers or other tools. Glue head
D50 with
thread 1/4“
#12134

1 Connect the MEASURED WATER SUPPLY to the pipe behind the pump,
and before the filter and before the coagulation mixer.

Connect the MEASURED WATER DRAINAGE to the pipe behind the filter
2
and behind the heating or into the overflow tank or skimmer. T-joint

To connect the measured water to the ASIN AQUA use PE tube 1/4 “(6.35
mm) #12008, which is part of the packaging.

90°

PE tube 1/4 “(6.35 mm)

WARNING
Cut the PE tube at an angle of 90 ° to ensure tight joints. The cut must be clean.
Use special pliers #13325 to cut plastic tubes. Do not use common scissors or
knives!

The measured water is easily connected to ASIN AQUA using the Speedfit
push-in fitting.
Water valve
CONNECTION Push the connecting pipe into the Speedfit fitting fitting CONNECTION
and pull out the hose to secure.

DISCONNECT push and hold the Speedfit round collet


and pull out the connecting pipe.
G1/4” thread PE tube 1/4 “(6.35 mm)

INLET of the measured water to the ASIN AQUA LOCKING


3
Connect the tube to the bottom Speedfit of the measured water filter.

OUTPUT of the measured water from ASIN AQUA


4 Pull out
Connect the tube to the side Speedfit on the probe housing.

DISCONNECTION
Once connected, ASIN AQUA is ready to measure disinfectant content and
pH value in your pool.

CS 11
FROM BOTTOM

12
FROM SKIMMER

CS
Max 2 m
3-WAY BESGO SAMPLING POINT

3
FLOWMETER

PUMP VS
COAGULATION MIXER
Max 8 m
CHLORINE

1
pH

WASTE
ALGICID

5-WAY BESGO
FLOCC

FLOC+C
4

FILTRATION
Max 8 m

4-WAY BESGO
TO SOLAR

ALGICID
pH MINUS
FROM SOLAR CHLOR PURE

OXYPURE
HEATING
2

TO POOL
Pool Chemicals
Connection
Plug with
Screw the injection valve in the glue head D50 with thread G1 / 4 “ #12134, D = 50 with
glued to the T-piece. Tighten the injection valve into the head by hands thread 1/4“
only. Do not use pliers or other tools.

Connect the FLOC+C INJECTION VALVE to the pipe before the coag-
1 T-joint
ulation mixer and before the filter and after the MEASURED WATER
SUPPLY.

2 Connect the ALGICIDE, pH, and CHLORPURE or OXYPURE INJEC-


TION VALVE to the pipe behind the filter and behind the MEASURED
WATER DRAINAGE. Connect injection valves in this order to prevent forma-
tion of lime scale.
4

To connect reagents from cans to the ASIN AQUA and from the ASIN AQUA
to the injection valves use PE Tube 1/4 “(6.35 mm) #12008, which is part of
the packaging.

WARNING

Ø 6,35 mm

Ø 1 mm
Cut the PE tube at an angle of 90 ° to ensure tight joints. The cut must be clean.
3
Use special pliers #13325 to cut plastic tubes. Do not use common scissors or
knives!

3 CANISTER CONNECTION Drill 6.35 mm and 1 mm diameter holes in the


can’s cap. Pass the tube through the hole in the cap so that it reaches the
bottom of the can. Place the suction tube weight at the end of the tube.

4 PUMP CONNECTION Connect the can with the left (suction) connector of
the pump using a PE tube from the can.

5 INJECTION VALVE CONNECTION Pass the tube through the injection


5
valve nut, connect the tube onto the injection valve and tighten the nut firmly
by hand. Connect the tube from injection valve with the right (discharge)
connector of the pump.

WARNING
NEVER CONNECT pH minus reagent to disinfection pump or disinfectant
to pH pump! In the case of a cross-connection, after ten doses ASIN AQUA
displays an error message. Repair the piping installation and then you can
continue to operate your ASIN AQUA.

CS 13
Accessories Connection
POWER SUPPLY
ZDROJ NAPÁJENÍ
230 V ~ 50 Hz
230 V ~ 50 Hz

L N L N

36 37 38 39 40
230 V ~ 50 Hz

1
2
3

RELAY 230 V, MAX 1 A


230 V
30 31 32 33 34 35
Filling

Solenoid valve
Solenoid relé
dopuštění
filling max 1A
(+)
Bottom B.wash

Besgo
Besgo 5 valve
W 5W
Filter
Praníbackwash
filtru

Besgo 3
Besgo W 3W
valve
Dnová
OFF výpust
Bottom (+)

ON Overflow

L
Heating
26 27 28 29

Topení relay
Heating
L
Bezpotencionální RELAY
POTENTIAL-FREE
relé
Max 1 A, Max 230 V
Timer

Solar / Timer
Bez funkce
21 22 23 24 25

Speed
Speed 33 HIGH
HIGH
3

Speed
Speed 22 MEDIUM
MEDIUM
2

Řízení
VS pump

Speed
Speed 11 LOWLOW VS PUMP CONTROL
variabilního
1

Speed
čerpadla
Speed 00 STOP
STOP
0

COM COM
COM
T800mA
ROLLER
Roleta SHUTTER
POSITION
9 10
Cover

Roller shutter
Bazénová roleta
position

POTENTIAL-FREE
Sepnuto – zavřená RELAY!
8
Level

Water level
Hladinoměr Rozepnuto – otevřená
sensor Connected – cover close
7

Disconnected – cover open


6
T out

Air
Teploměr vzduch
thermometer
5
T water
11 12 13 14
RS 485 Display

Water
Teploměr voda
thermometer
3

SENSOR INPUT 4 – 20 mA
Vstupy
2
Flow

Průtokoměr
Flow detector
1

External display
Externí display
13 14 11 12

External
B

Display
GND +12V

14 EN
VS pump connection

WARNING
Always check the connection according to the current user manual of your pump
manufacturer.

Speed
TYP A TYP B TYP C
COM S1 S2 S3 STOP COM S1 S2 S3 S4 COM S1 S2 S3 STOP
n1 ON OFF OFF OFF n1 ON OFF OFF OFF n1 ON OFF OFF OFF
n2 OFF ON OFF OFF n2 OFF ON OFF OFF n2 OFF ON OFF OFF
n3 OFF OFF ON OFF n3 OFF OFF ON OFF n3 OFF OFF ON OFF
S OFF OFF OFF ON S OFF OFF OFF ON S ON ON ON OFF

Relay status
HAYWARD (older type) TYP C
TYP A DI4

21 22 23 24 25
Speed 3

3
DI3
Speed 2

2
VS pump
SPECK TYP A UWE EO PM Speed 1
DI2
TYP A

1
N3 DI1 CONNECTED
NOT
Speed 3
0

30
21 22 23 24 25

Speed 3 Speed
3

N2 C
SPEED 3
COM COM 2
21 22 23 24
Speed 2 Speed
2

2
VS pump

VS pump
N1 SPEED 2
Speed 1 Speed 1
1

STOP SPEED 1
Speed 0 Speed 0
0

GND GND
COM COM COM COM

INVERTER POOL PUMP TYP A HAYWARD KS Evo VS TYP A


N3 DI3
21 22 23 24 25

21 22 23 24 25

Speed 3 Speed 3
3

N2 DI2
Speed 2 Speed 2
2

2
VS pump

VS pump

N1 DI1
Speed 1 Speed 1
1

STOP DI4
Speed 0 Speed 0
0

GND C
COM COM COM COM

TYP B
PENTAIR TYP B DAB E.SWIM - E.PRO TYP B
OVERDRIVE 11
21 22 23 24 25

21 22 23 24 25

Speed 3 Speed 3
3

N3 8
Speed 2 Speed 2
2

2
VS pump

VS pump

N2 7
Speed 1 Speed 1
1

N1 6
Speed 0 Speed 0
0

+5V 3
COM COM COM COM

TYP C
HAYWARD (older type) TYP C
DI4
21 22 23 24 25

Speed 3
3

DI3
Speed 2
2
VS pump

DI2
Speed 1
1

DI1
Speed 0
0

C
COM COM

EN 15
Power Supply
Connection to the mains:

1. Leave the mains switch in the OFF position.

2. Connect filtering device to the ASIN AQUA Home switched socket outlet
Installation must be
(filtration power supply - max. 1.4 kW / 230 VAC).
protected by a residual
current device (RCD). 3. Connect the 230 V / 50 Hz mains cable to ASIN AQUA Home (on the right
side). The mains socket outlet must be protected by a residual current
device (RCD).

4. Change the mains switch over to the ON position.

Residual After Device has been switched on, the display will come on and the ASIN
CHLORINE pH ALGICID FLOCC
current
Proudový AQUA Home starting screen will appear.
RCD device,
chránič
30 mA
30 mA Disconnection from the mains:

230
230 VV / 50
/ 50 Hz Hz
1. Change the mains switch over to the OFF position.

Max.
Max 1,41,4
kW kW
2. Disconnect the ASIN AQUA Home mains cable from the 230 V / 50 Hz
230 v~
230 V~ socket outlet.

3. Disconnect the filtering unit mains cable from ASIN AQUA Home.

WARNING: If Device is used in the manner different from that specified by


the manufacturer, protection provided by Device may get damaged.

Power supply 230 V / 50 Hz


Power consumption 24 VA
Power consumption (including filter pump) 1449 VA
Maximum input power of connected 1.4 kW / 230 VAC
filtration
Fuse T800 mA; T125 mA; T6,3 A
Over-voltage category II
Ingress protection IP30
Operating temperature +5 to +40°C
Weight 6.7 kg
Installation wall mounted
Relay output contacts 230 V / 1,4 kW
Discharge of dosing pumps 60 ml / min / max. 1bar
Measured water pressure max. 1 bar
(must not be vacuum)
Dimensions 430 x 330 x 160 mm

16 EN
Installation Test
WARNING: Any obstacles, bubbles or leaks in the connecting tube will
prevent ASIN AQUA Home from correct operating. The clear plastic tube
allows you to monitor flow of liquid to the injecting valves.

Before commencing the operation, test ASIN AQUA Home installation.


Most problems result from incorrect installation.

Test
In the “Relay Test” menu, start pumps one by one and while they are
running, check tightness of all the PE tube connections. Check the injecting
valves for blockage and air bubbles in the PE tube.

Press to TURN ON (GREEN) and press again to TURN OFF.

DON’T FORGET! After you complete the test, stop all accessories in
the menu. Do not dose in this step!

CHLORINE pH ALGICID FLOCC

2.
If bubbles occur here, the
1. pump sucked air. Repair the
Monitor level in the connection - disconnect the
transparent plastic tube. tube, cut the end carefully at
a 90° angle, and plug it back.

3.
Check tightness of all the
connections.

Liquid must reach injection valve


and the pipe.

EN 17
Touch screen description
Home Screen
The home screen displays measured values, required values and status
information.

E.g. click on the Chlorine to enter the setting of the required chlorine value.

Required Value.
Measured Value.

The chlorine pump status – ON.

ON indicates the current status of ON - filtration runs according to Enter the settings.
filtration. The Timer allows to set the preset periods.
filtration periods. NONSTOP 24 h – filtration runs
continuously for 24 hours.

Manual control allows to:


switch filtration on/off
independently to preset filtration
periods.
start filter washing independently
to preset backwash periods.

18 EN
Settings

Back to the home More information for Back to the previous


screen. currect screen. screen.

Movement through Menu

Movement in menu to the previous page. ON - function is


switched on
Indicator of the current page and the total
number of pages.
Movement in menu to the next page.

OFF - function is
switched off

Value Settings

Decrease the value. Increase the value. Save the set value

EN 19
Configuration

Date and Time


To ensure the correct function of timers, set the current date and time.

Pool Volume
To ensure the correct function of ASIN AQUA, enter the correct volume of
your pool. Calculate your pool volume in m3:

Length (L) times width (W) times depth (D) is volume (V) - (L × W × D = V).

Enter the value using + and - buttons.

WARNING: The pool volume has effect on the maximum safe dose, enter
the value correctly.

Filtration Timer
Filtration timer can be set to NONSTOP 24 hours operation, or to one or two
filtration periods.

Between periods (requires VS pump)


ASIN AQUA allows you to control the variable speed circulation pumps. The
variable speed pump runs at speed 2 during filtration periods. Outside of
filtration periods, when the standard circulation pump is off, the variable
speed pump can run at speed 1 or be OFF (depending on its setting).

Automatic Filter Washing


The ASIN AQUA technology is in particular based on the high efficiency of
filtering and removing even the finest impurities, it is necessary to wash the
filter on a regular basis. The automatic filter backwashing function ensures
the filter washing on a regular basis in the preselected intervals.

To enable this function, it is necessary to use the automatic 5-way


BESGO valve. The ASIN AQUA controlls the BESGO valve with rellay output.

When the relay switches ON, the BESGO valve switches to the required
position with the pressure of water or air and performs the Filter backwash.
See the BESGO manual.

20 EN
Smart Heating

Water Temperature Measurement and Heating Control


The water thermometer should be installed in the inlet pipe coming from
the pool. Never install it behind the heat exchanger. When the temperature
drops below the required value, the relay switches ON your heat source
(heat pump, electric heating, gas boiler circulating pump).

Heating Control Function Takes Priority over Filtration Control


If you select the option heating control is parent to filtration control, then
the water temperature takes priority over the filtration timer. The heating as
well as the circulating pump will be running even outside of the set filtration
periods. The pump and the heating stop only when the required temperature
is reached.

Heating Time settings


This function allows to set a time for which the heating will be in operation.
This is particularly useful for switching on the heat pumps which have
a higher efficiency during the day when outdoor temperature is higher.
Eventually, turn off the heat pump during a specific time to reduce the noise
from the heat pump.

Heating at Outdoor Temperature (above or below)


This feature allows you to set the outdoor air temperature, at which or below
which ASIN AQUA starts heating. To use this feature, an outdoor air ther-
mometer must be installed. This function is used to optimize the effective-
ness of air heat pumps, which have higher efficiency at higher temperatures.

EN 21
Winter mode
Activating this function set the device into the special Winter mode. This
mode prevents the pool water from freezing and keeps the water clean with
dosing of algaecide.

In the Winter mode following function are deactivated: chlorine dosing,


pH dosing, flocculant dosing, water filling, filter backwash. Water flow is
set to the bottom drain.

Every day the filtration pump runs in preset filtration timer.

Outside of the filtration timer the filtration pump remains OFF (VS pump
SPEED 0) but is automatically activated for the period of 15 minutes when
WARNING: DO NOT the outdoor temperature drops below 0°C.
USE HEAT PUMP IN THE
• If, after the period of 15 minutes, the water temperature is under the set
WINTER MODE!
temperature of 2°C, the filtration pump stays ON, and the heating is acti-
Winter mode does not vated until the water temperature exceeds the set temperature.
protect the heat pump from
• If, after the period of 15 minutes, the water temperature is higher than
freezing.
set 2°C, the circulation pump is turned OFF.
Disconnect the heat pump
If the outdoor temperature stays below 0°C this cycle is repeated every
and winterize it separately.
6 hours.
Follow the heat pump
manufacturer‘s manual. When using the Winter mode without the outdoor air thermometer, the
system acts as it always detects 0°C outdoor temperateru.

Warning: Winter mode must not be used with the heat pump. The entire
system is programmed that it does not protect the heat pump against
freezing in the event of severe frosts. The winter mode can only be used in
fully inground (thermally isolated) pools with filtration technology located in a
in a non-freezing environment. The winter mode cannot be used for above-
ground pools

22 EN
Hoch – Alarm
Nachfüllen – OFF
Aktuell
Niveau Nachfüllen – ON
Niedrig – Alarm
Level sensor - Level Monitoring and Automatic
Refilling
The water level is monitored using a pressure-type level sensor, which is
easy installed by inserting the probe into the buffer tank or the blind nozzle
of skimmer pools. ASIN AQUA monitors four different levels, which can be
set in centimeters in the water level meter menu.

Setting:
High level ALARM - too much water in buffer tank
After this level is reached, following actions may start:
1. If the automatic filter backwash is enabled, one backwash cycle starts
Hoch level
High – Alarm
– Alarm and drains the waste water.
2. If the automatic filter backwash is not enabled, the relay 19 switches
Nachfüllen
Filling – OFF
– OFF
Actual
Aktuell on (filter backwash) for the period of time until level is OK. The second
Level
Niveau Nachfüllen
Filling – ON– ON
circulating pump or automatic drain valve can be connected to this relay.
Niedrig
Low – Alarm
level – Alarm Refilling OFF - required level
Niveau00cm
Level cm Refilling stops
Refilling ON - level at which refilling starts
Refilling starts after if the water level stay permanently at least for
10 seconds below this value (in order to prevent oscillating)
Low level ALARM
Circulation (filtration) pump shuts off

Flow detection
The flow detector detects flow of measured water. Dosing of chemicals will
take action only if the water flow to probes is detected.

Warning: Only switch off the flow detector in case of a failure.

Delay
Delay time after dose is time for which ASIN AQUA does not dose and wait
for the response of probes. The average response time is 4 to 10 min, at SPA
1 to 10 min.

Delay time after start of the filtration pump (upon timer switching on) is
time after start for which ASIN AQUA does not take any action and waits for
stabilization of a signal from probes.

Concentration pH –
If you use the original ASEKO Pool & SPA chemicals keep the preset value.
In case of use of non-original chemicals adjust concentration according to
data on the label of a chemical used.

Warning: Higher concentrations of chemicals can result in shorter lifetime


of ASIN AQUA components and may cause injury and health damage.

EN 23
VS variable speed pump control
In the settings, select the type of your variable speed pump.
ASIN AQUA allows you to use 4 speeds of your VS pump.
Speed ​​0 (OFF)
Speed ​​1 (LOW) for economical filtration outside the TIMER.
Speed ​​2 (MEDIUM) for filtration during TIMER periods.
Speed ​​3 (HIGH) during filter backwash.

By default, the variable speed pump runs at speed 2 during filtration


timer periods. Outside of the filtration timer periods, when the standard
circulation pump is off, the variable speed pump can run at speed 1 or
be OFF (depending on its setting). During filter backwash, the pump is
automatically set to speed 3.

Individual speeds are set directly on the pump according to the pump
manufacturer’s manual.

Programmable relay

Solar heating

To use this function, in the menu PROGRAMMABLE RELAY choose the


option SOLAR. Connect the air thermometer to the solar absorber
and to the POTENTIAL-FREE relay TIMER / HEATING connect what is to be
controlled by the relay.

Once the temperature of the solar absorber is 5 °C higher than the


temperature of the water, ASIN AQUA activates the relay which starts the
circulation of the water to the solar absorber. When the temperature of
the solar absorber is not 2 °C higher than water temperature the relay is
deactivated.

When using both solar heating and the heat pump simultaneously, SMART
HEATING gives the option to automatically disable the heat pump, utilizing
only solar absorbers to optimize electrical consumption.
• In the HEATING CONTROL menu go to the Heating at Outdoor Tem-
perature (above or below) and check the HEAT BELOW option. Set the
temperature between 30 to 40 °C.

WARNING: With use of solar collector set the filtration timer through all the
hours of sunshine to prevent overheating of the solar collector.

WARNING: In order to activate this function, heating control must be


switched ON.

WARNING: Air thermometer must be connected to the solar absorber.

Timer

To use this function, in the menu PROGRAMMABLE RELAY choose the


option TIMER. One or two intervals can be set for the activation of the relay.
Connect what is to be controlled by the TIMER to the POTENTIAL-FREE
relay Timer / Heating.

24 EN
Other automatic functions

BESGO 3-way
Switch of pool water flow - Besgo 3w
#83140 OVERFLOW / BOTTOM DRAIN
During set filtration timer periods, water flows through the OVERFLOW (relay
is activated).
Outside the set filtration timer periods, water flows through the BOTTOM
DRAIN (relay deactivated).
During filter backwash, water flows through the BOTTOM DRAIN.
An alarm WATER LEVEL TOO HIGH switches the water flow to the OVERFLOW
until the alarm expires.
The pool cover has no effect on the BOTTOM / OVERFLOW switching.
The three-way BESGO should be connected in a way that when the
solenoid valve is not powered, water flows through the BOTTOM.

Pool cover position


If the pool cover is closed during the filtration time set by the timer, the VS
pump will change the speed to the Speed 1 (LOW).

EN 25
Choosing the type of probe or
the type of time dosing
1. CLF free chlorine probe for ASIN AQUA HOME CLF
Free chlorine measurement, CHLOR PURE dosing

2. Redox probe for ASIN AQUA HOME Redox


Measurement of redox potential, CHLOR PURE dosing

3. Time dosing without probe for ASIN AQUA HOME OXY


Timebased dosing of OXY PURE

Commissioning procedure and


required value setting

Commissioning procedure
The water in the pool must be clean without any additives.
Ideally fill the pool with fresh water from the water main.

• Set the Filtration timer to NONSTOP 24 hours

• If you have the CLF probe, set the disinfection to 0.0 mg/l.
If you have the REDOX probe, set the disinfection to 000 mV.
If you have the Time dosing set the required value of OXY Pure to 0 ml/m³/day.

N CLOSE
CLOSE
Close the water supply to the probes
ASIN AQUA displays no flow to the probes.

Perform shock chlorination


SuperCHLOR
#13120 Perform shock chlorination of pool water with Super CHLOR (inorganic
active chlorine without stabilizers).
Follow the instructions on the packaging (1 kg = 80 m3).

26 EN
Before opening the water supply to the probes

1. ASIN AQUA HOME CLF or Redox


The water must be clean and the chlorine concentration measured by the
digital tester must be between 0.3 and 1.2 mg/l. If the concentration is
lower, repeat shock chlorination. If the concentration is higher, wait till the
chlorine concentration in the water drop down.

2. ASIN AQUA HOME OXY

Wait 24 hours.

OPEN
OPEN Open the water supply to the probes
CLOSE
Warning No flow to probes turns off automatically.

pH Setting
Considering that the ASIN AQUA Home water treatment system is efficient in
the broad pH range, it is recommended to enter the required pH value equal
to pH value of water you refill or slightly lower.

Required pH value = refilled water pH value (in the range from 6.8 to
7.5)

pH may change during operation but if it is in the range from 6.8 to 7.5 you
do not have to change this setting.

ALGICIDE Setting
A sufficiently effective dose for most pools is 10 ml/m3 per day. If green
algae appear in the pool, you can increase the dose. After algae have
disappeared, the dose can be returned to 10 ml.

FLOC+C Setting
The FLOC + C dose is calculated from the amount of circulating water, which
flows through the filtration.
Based on your circulating pump power (in m³ per hour), adjust the FLOC + C
dose value. E.g. with the circulation pump with power of 10 m³/h set the
FLOC + C dose to 10ml/h.This value ranges from 10 to 40 ml per hour for
most private pools.

EN 27
If you use the CLF probe
For the correct functionality of the CLF probe you must observe the
following conditions:

pH of the pool water


The pH value should be between 6.8 and 7.5.
The pH of the pool water must be stable.
If the pH value fluctuates, the value of the chlorine changes accordingly.

Chlorine Water Determination of the required chlorine value in pool


content mg/l temperature water
0.3 to 0.5 24 to 26 °C The required concentration of chlorine in pool water varies with the tem-
0.5 to 0.8 26 to 32 °C perature of the pool water. However it should never be less than 0.3 mg/l.
0.8 to 1 Over 32 °C Determine the required value using the table on the left.

WARNING
Befor proceeding to setting of the required values, keep the probe connected
to the water for at least 1 hour, ideal 24 hours, to stabilize its measurement.

How to set the required chlorine value


Use a colorimeter or digital Pool Tester to measure the chlorine value in pool
water sample.

If the chlorine concentration (measured with a colorimeter or digital


Pool Tester) is:

• ADEQUATE to the value shown on the ASIN AQUA Home, your


device is ready to maintain the required concentration of chlorine in pool
water.

• BELOW the required value shown on the ASIN AQUA Home,


increase the required value by 0.1 (by 0.2 mg/l max) (regardless of
the required value according to the table).

Repeat the measurement after the water in the pool is mixed thoroughly
and the value shown on the ASIN AQUA is stable.
Repeat the process until the chlorine concentration in pool water
matches your required value then set the correct required value
according to the table. Additionally, you can perform the calibration of
the CLF probe (see the chapter CLF Probe Calibration).

• HIGHER than the required value shown on the ASIN AQUA Home
display - you can calibrate the CLF probe (see the chapter CLF Probe
Calibration).

NOTIFICATION:
Fix the low chlorine value in pool water by increasing required disinfec-
tion value on the display of the unit.

RECOMMENDATION: Check the chlorine value in the pool once a week


using the colorimeter or digital pool tester.

28 EN
If you use the Redox probe
For the correct functionality of the REDOX probe, you must observe
the following conditions:

pH of the pool water


The pH value should be between 6.8 and 7.5.
The pH of the pool water must be stabilized.
If the pH value fluctuates, the value of the Redox changes accordingly.

Chlorine Water Determination of the required chlorine value in pool


content mg/l temperature water
0.3 to 0.5 24 to 26 °C The required concentration of chlorine in pool water varies with the tem-
0.5 to 0.8 26 to 32 °C perature of the pool water. However it should never be less than 0.3 mg/l.
0.8 to 1 Over 32 °C Determine the required value using the table located on the left.

WARNING
Befor proceeding to setting of the required values, keep the probe connected
to the water for at least 1 hour, ideal 24 hours, to stabilize its measurement.

How to set the required Redox value


Set the required REDOX value to 650 mV

Use the tester to check if the chlorine content in pool water is within the
range of 0.5 - 1.2 mg/l.

Fine-tuning
Use the colorimeter or Pool Tester to measure the chlorine value of the pool
water. If the manually measured chlorine value in pool water is:

• ADEQUATE, your ASIN AQUA Home is ready to maintain the required


concentration of chlorine in pool water.

• LOW, increase the required REDOX mV value in the menu.


• HIGH, reduce the REDOX mV value in the menu.

Every 10 mV corresponds approximately to 0.1 mg/l of chlorine in the


pool water.

EXAMPLE:
The chlorine value in the pool water is 0.3 mg/l - the displayed value is
650 mV. If you want to increase the chlorine value to 0.5 mg/l. You have to
increase the preset value of the redox by 20 mV to 670 mV.

NOTE:
The relationship of Redox potential and chlorine value in pool water cannot
be determined by the exact table. The correct value of the Redox must be
observed by several check measurements.

EN 29
Safety Functions

Safety disinfection dosage - without Probe


Response
If the measured disinfection value does not increase after preset maximum
safety disinfection dose (according to the settings), ASIN AQUA stops
disinfection dosing and an error message appears on the display.
The other ASIN AQUA functions are not limited.
The error message must be canceled manually.

Maximum Number of pH Doses - without Probe


Response
If the measured pH value does not decrease even after preset maximum
number of doses (according to the settings), ASIN AQUA stops pH dosing
and an error message appears on the display.
The other ASIN AQUA functions are not limited.
The error message must be canceled manually.

Maximum Refilling Time


Maximum time to reach the required water level. If the water level is not
reached within the preset maximum refilling time an error message appears.

Operation
In standard automatic mode, only these 3 screens are displayed.

Home screen

Delay after start


ASIN AQUA does not dose and waits for the probes to stabilize and the pool
water to mix.

Filtration is turned off by the timer

30 EN
In Operation Measurement and
Calibration

pH Probe Calibration
Calibration is not possible
When pH is being measured in operation, there may be a difference between
when the new value differs
the value measured by ASIN AQUA and the actual pH value in water. Proceed
by more than 1 from the
to the calibration.
non-calibrated value.

The pH probe can only be


calibrated in the pH range of
6.2 to 7.8.

The pH probe cannot be


calibrated when the LOW or
HIGH warning is displayed.

pH Probe Calibration menu


Non-calibrated value

The pH probe calibration menu always displays the original non-calibrated


value. Calibration of the pH probe is not possible when the new value differs
by more than 1 from the non-calibrated value. If the difference from the
non-calibrated value exceeds 1, the probe should be sent for inspection or
replaced with a new one.

pH Probe Calibration process

Calibration can be done in two ways:


pH 7.00 Buffer #12065

1. With a buffer
• Close the water supply to the probes.
• Remove the probe from ASIN AQUA Home :
rinse the probe with clean water and wipe it.
• The probe must remain connected to the device via the cable. Dip the
probe in the calibration buffer and after the value displayed on ASIN
AQUA is stable, enter the buffer value into the pH Probe Calibration
Photometr menu.
#13076

2. With a colorimeter or Pool Tester


• The water supply to the probes must be open
• Measure the pH value directly in pool water using a colorimeter or Pool
Tester.
• Then enter this value into the pH Probe Calibration manu. Calibration can
be performed in the range of 6.4-7.8.

EN 31
CLF Probe calibration

Do not calibrate the probe until the water in the pool is thoroughly mixed
and the value displayed on the ASIN AQUA is stable.

This may take several hours.

Perform calibration of the CLF probe when the manually measured value
of free chlorine is equal to or higher than the value you are calibrating to.

Calibration is performed by entering the manually measured value of chlo-


rine concentration (using a photometer) in the CLF Probe Calibration menu.

Photometr
#13076

Calibration is not necessary if the difference between the photometer mea-


sured value and the value shown on the display is less than 0.2 mg / liter.
0,5
CHLORINE pH ALGICID FLOCC

0,4

Calibration is best performed with chlorine concentrations in the pool water


0,3 in the range of 0.3 - 1.2 mg / l.

0,4 0,7

0,3 – 1,2 mg/l

Calibration restrictions
The CLF probe cannot be calibrated if the output signal is less than 20 mV.

The CLF probe can only be calibrated in the CL range from 0.3 to 5.0 mg / l.

32 EN
#12177 OX tester Adjustment of OXYPURE Active Oxygen Dose
When using chlorine-free technology ASIN AQUA HOME OXY the optimum
OXYPURE concentration value is from 50 to 100 mg.
From time to time check this value by measuring with the OX tester and
adjust the dose in the menu, if required.

Water Thermometer Calibration


If the temperature of water in the pool is different from the temperature
shown on ASIN AQUA, calibrate the water thermometer in the water
thermometer calibration menu.

Air Thermometer Calibration


If the temperature of air is different from the temperature shown
on ASIN AQUA, calibrate the air thermometer in the air thermometer
calibration menu.

Stabilizer in water
The water in the pool must be clean without any additives.
Ideally fill the pool with fresh water from the water main.

BALANCER #13039
Alkalinity
Alkalinity volume in the water should range from 80 to 120 ppm. Alkalinity
stabilizes the pH and reduces its consumption. To increase the Alkalinity in
the water, use Pool & SPA BALANCER (#13039).

Cyanuric Acid
The value of Cyanuric acid must be 0 ppm. Cyanuric acid greatly diminish
the effectiveness of chlorine, making it difficult to accurately measure and
control its concentration. If the presence of cyanuric acid is detected, fill the
pool with fresh water.

EN 33
Maintenance
#12073 Replacement hose
for the pump PP 60 To ensure the optimum efficiency, perform visual checks and maintenance
of ASIN AQUA on a regular basis.

Pump tube replacement


To prevent the pump from failing, it is recommended to replace the tube
#12073 every 24 months.

In doing so, proceed as follows:

• Switch off ASIN AQUA Home.

• Turn the pump cover cassette anticlockwise and take it out of ASIN
AQUA Home.

• Release both tube ends and take it out of the cassette.

• Lubricate the new tube with the supplied special grease.


CHLORINE pH ALGICID FLOCC

• Insert the lubricated hose into the cassette.

• Place the cover cassette back on ASIN AQUA Home and turn it clockwise
to lock it.

• Use new nuts, which are part of the replacement tube set, for connection
of the PE tube.

#12005 Injection valve Injection valve maintenance


On a regular basis, check throughput of the injection valves, rubber band
integrity, remove scale.

In case of private pools, replace injection valve rubber bands #13087 every 2
years. In case of public pools, replace #12005 every year.

#13087 Replacement rubber band


for injection valve

 Flow detector #12106


Flow detector with filter
Rinse the filter of the flow detector regularly.

34 EN
Fuse Replacement
Fuse T 125 mA #13078
Fuse T 800 mA #13096
Fuse T 6,3 A #13099 T125 A Fuse
Fuse protecting the inner electronics. In case of its burnout, check the inner
electronics.

T800 mA Fuse
Fuse protecting external sensors. In case of burnout of this fuse, check the
level sensor, flow detector, and external display.

T6,3 A Fuse

Fuse protecting the device, including the BESGO valves and circulation
pump.

pH Probe Testing
pH - Buffer 7,00 #12065
Take the probe out of ASIN AQUA housing and clean it from impurities.
Check for visible mechanical damage on the probe.

Measure the pH value and ensure it falls within the tolerance range of +/-
1.0. For example, if the water pH is 7.2 and the probe measures 7.9, it is in
tolerance, the probe is considered okay.

Test the probe’s response to positive or negative changes in water or buffer


by immersing it in a 7.0 pH buffer and observing the response after one min-
ute. The response should be at least 90%.

Follow the instructions in the user’s manual for the probe.

CLF Probe Testing


The free chlorine probe should output a signal higher than 20 mV at a free
chlorine concentration of 0.8 mg/liter.

If the signal is lower, send the probe for inspection.

Conduct a test with clean water without chlorine (standing for 24 hours)
and ensure the signal is lower than 20 mV. Otherwise, send the probe for
inspection.
Redox Buffer 475 mV #12063
REDOX Probe Testing
Take the probe out of ASIN AQUA housing and clean it from impurities.
Check for visible mechanical damage on the probe.

Ensure that the redox probe’s sensitivity does not exceed -12% and that it
measures above 420 mV at the buffer value of 475 mV.

Test the probe’s response to positive or negative changes in water


with 0 chlorine concentration.

There is no manufacturer of pH and REDOX probes that cover its


products with warranty. ASEKO has decided to cover supplied probes
to its clients by two year warranty period that cover free repair of
supplied probe that will have higher tolerance than above described.

EN 35
Winterizing - storage during
winter
If you want to operate ASIN AQUA in Winter mode, go to the chapter Con-
figuration - Winter mode. If you do not want to operate the device in Winter
mode, it is necessary to winterize the device and all its components (store
them when not in use).

Winterization of the unit and its accessories


If you do not want to have the ASIN AQUA device in operation in winter, the
device and all accessories must be dismantled, winterized and moved to a
suitable location. To disassemble and winterize the ASIN AQUA, follow the
instructions below.

Storing of pool chemicals, connecting PE tube and dosing


pumps
• If the chemicals are left in a place where the temperature does not drop
below 0°C, turn OFF the ASIN AQUA. Disconnect the dosing pumps from
the ASIN AQUA and remove the inner tube from the pump. Leave the
tube connected to the connecting PE tube. Put the pump cartridges
without the inner tubes back onto the ASIN AQUA. Store the chemical
barrels and connecting PE tube in a place where the temperature is
between +0 - +40 °C.

• If chemicals remain in a location where the temperature drops below


0°C, SWITCH OFF ASIN AQUA. Remove the connecting PE tubes from
the chemical barrels and place them in a container with water. Turn on

CHLORINE pH ALGICID FLOCC


ASIN AQUA. Go to the RELAY TEST menu and press Chlor/Oxypure, pH,
Algicide and Floc. When the connecting PE tube is completely filled with
water, turn OFF the relay test. Remove the water container and perform
the RELAY TEST again to completely fill the connecting PE tube with air.
When the connecting PE tube is completely filled with air, stop the relay
test and turn OFF the ASIN AQUA. Disconnect the connecting PE tubes
from the dosing pumps and from the injection valves. Store the chemical
barrels in a place where the temperature is between +0 - +40 °C.

Disconnect of the ASIN AQUA and its accessories


1. Disconnect the ASIN AQUA Home mains cable from the 230 V / 50 Hz
socket.

2. Disconnect the filter unit’s mains cable from the ASIN AQUA and store
the filtration pump according to manufacturers manual.

3. Disconnect all accessories from the ASIN AQUA motherboard and store
them according to manufacturers manual.

36 EN
Winterizing of probes
#12154 Probe storing sump
Winterizing of pH and Redox probe

Remove the probe from the housing, dry it with a paper towel and place it in
a storage sump filled with a special storage liquid. See probes manual at the
website manuals.asekopool.com.

#12082 Probe storing liquid

Winterizing of CLF probe

Remove the probe from the housing, unscrew the membrane and empty the
electrolyte from it. Do not put the membrane back on the probe and store
them separately in a dust-free place where the temperature is between +5
- +40 °C and the humidity does not exceed 70% throughout the winter. See
probes manual at the website manuals.asekopool.com.

Storing of the unit


Move the ASIN AQUA unit in a place where the temperature is between +5 -
+40 °C and the humidity does not exceed 70%.

40 °C
max.

CHLORINE pH ALGICID FLOCC

5 °C
min.

40 cm

CHLORINE pH ALGICID FLOCC

40cm 40 cm
40 cm

150 cm

EN 37
Internet connection
The LAN connector is to be connected to the domestic router.
Data are sent in the intervals of 10 seconds to the address
pool.aseko.com, the route must not be blocked by the firewall.

If you are not able to setup the connection by your own ask your IT specialist
for help.

Possible connection methods

Home network
Connect the ASIN AQUA Home to your router via LAL cable.

Mobile network
In case you have no direct internet access you can use the data transmis-
sion over the mobile network. Connect the ASIN AQUA Home to your mobile
network router via LAN cable.

Wifi connection
If you install the ASIN AQUA Home in place where is no access to your pri-
vate network by wired connection but your Wifi has enough signal, you can
connect the ASIN AQUA Home to your Wifi by use of Wifi extender.

Powerline via 230V/DC


If you have no wired access to your LAN network but your ASIN AQUA Home
is in the at the same electric network you can connect the LAN network via
230 V power line socket adapter.

If you have connection problems:


Please switch off ASIN AQUA.
Restart the router and switch on the ASIN AQUA again.

The home network must be open to communication on both sides


for URL: pool.aseko.com

38 EN
LAN

INTERNET
Home network

3G / LTE INTERNET

WIFI EXTENDER

Wifi extender

INTERNET

Powerline
via 230 V
socket outlet 230 V

INTERNET

EN 39
Aseko web services

Pool live
The internet connection allows you to use the Pool Live mobile application
and monitor your pool on mobile devices wherever the internet connection is
available.

After you connect the ASIN AQUA to the internet download the Pool Live
application to your smartphone. Application is available for iOS and Android
operation systems.

App’s main screen, after opening, will ask for typing your ASIN AQUA serial
number.You can add more units to the Pool live app.

Pool LIVE Pool LIVE


for iOS for Android

40 EN
https://pool.aseko.com
The web application for detailed monitoring of the pool water quality by
means of well-arranged graphs. It shows all the measured parameters as
well as ASIN AQUA Home actions up to 30 days back.

This application is giving you the detailed information of the pool status and
detailed review of all events, taken actions and act levels of monitored items
up to 30 days back.

Transparent graphic environment of chart lines is giving fast report and you
can easily see interconnection of monitored values.

This application is useful at public pool installations where you need to


observe the history and monitor the pool water quality and maintenance.
In case of any discrepancy in water quality you can find all actions, provided
in that moment and in relation to other values you can diagnose the reason
of such discrepancy.

EN 41
Error messages

This error message This error message


appears after appears after 15/30
15/30/60 doses doses of pH without
of chlorine without probe reaction.
probe response.

This error message


appears when
the set maximum
chlorine dose is
exceeded.

Those error messages appear when:

Agent run out No water flow to probe


• Check liquid levels on a regular basis, refill in time. • Check the measured water filter and clean it, if
required.
Dosing pump does not dose • Check condition of connecting tubes from the
• Leakage in connection of PE tubes or they are extraction valve to the measured water inlet to probes
damaged. and furthermore, from the water outlet from probes

• Failure of dosing pump. Check whether pump is to the closing valve.

running. If so, check the hose inside the pump for • Check condition of the extraction valve and the
damage or breakage and replace it, if required. closing valve and their seals, for being clogged and
their closed position.
Injection valve clogged
• Impassable spray valve. Probe out of service
Check the valve for being clogged with impurities or • Measure pH using the hand tester. If the pH value is
deposits or the rubber seal for being damaged. too low, a respective agent was overdosed due to an

• Failure of dosing pump. Check whether pump is incorrect probe function (provided that other reasons

running. given in the previous points have been excluded).

If so, check the hose inside the pump for damage or • Take the probe out and check it for mechanical
breakage and replace it, if required. damage.

• Clean the probe following the above procedure.

• It is recommended to replace the probes with the new


probes
every two years.

42 EN
Too rapid pH change
Too rapid change of pH is usually caused by refilling water directly to
the skimmer. If such rapid change of pH occur, ASIN AQUA Home stops
controlling pH for two hours.

This limitation can be manually disabled.

After pH has been stabilized or two hours have elapsed, ASIN AQUA Home
changes over to the normal mode.

There is no flow to the probes


No flow to the probes was detected.

The probe shows a pH> 10


Check the pool water and probe.

The probe shows pH <4


Check the pool water and probe.

EN 43
Bottom
31
30 31
Besgo 3 W
Dnová výpust

30
(+)

L
Externes touchscreen display

Heating
26 27 28 29
Topení
L
Bezpotencionální
relé

Timer
Bez funkce
The external display shows

1. P
 ool
3 water
HIGH parameters:

21 22 23 24 25
Speed

3
Temperature,
Speed 2 MEDIUM pH value, redox potential or chlorine concentration.

2
Řízení

VS pump
Speed 1 LOW variabilního

1
2. Parameters of the air in the pool area:
čerpadla
Speed 0 STOP

0
relative humidity and temperature.
COM COM

The setpoints can be set on the ASIN AQUA device and a probe calibration
Salinity
19 20

can be carried out via the external display.


Salinita
External
Touchscreen Display
#12048 Sepnuto – zavřená
Rozepnuto – otevřená

T800mA
10
9 10
Cover

Bazénová roleta
9
11 12 13 14 15 16 17 18

8
8
Level

Hladinoměr Inputs
RS 485

7
7
6
6
T out

Teploměr vzduch
5
5
T water
RS 485 Display

4
4

Teploměr voda
3
3
2
2
Flow

Průtokoměr
External display
1
1

RS 485
Externí display RS 485
13 14 11 12

A
B
GND +12V

44 EN
Enhancement of filtering efficiency

AFM® activated filter media


AFM is direct substitute for filter sand. It doubles efficiency of the existing
filtration system. AFM® is resistant to biological pollution and formation of
so-called bio-film.

ZPM® coagulation mixer


ZPM increases effects of coagulation and flocculation for transition of
smaller dissolved solids (turbidity) to larger particles that can be removed by
filtering.

ASEKO Pool & Spa Floc + c


A unique mixture of coagulant and flocculant for increasing the efficiency of
the filter. The coagulant neutralizes the zeta potential, which keeps impurities
dispersed into a fine turbidity. The flocculant produces flakes that are better
captured by the filter.

Coagulation Flocculation Filtration


Inorganic coagulant and (inorganic coagulant) (polymeric flocculant) (AFM - Activated
polymeric flocculant < 1 second approx. 3 minutes Filter Media)
+ + +
+
- +
- - - +
- - - + -- -- +
+

- - - -- - + - - + - -
- - - + + +- ++ + +
- - -- - + + -
- -- -
- - -
- -
-
+ + +
- - - + + -- -- +
- - - - -
+ +
- - -- - - ++ - - + - -
- - - - - + - - + - - - + ++ +- +
- -- - - - - - - -+
- - - +
+ + + +
- - - - ZPM + +
+
-
- - - -- - - + -
+
-
FROM POOL

TO POOL

(Zeta Potential +
- -- Mixer) + - - +- - -+
+
- - +- +
+

Turbid water A zeta charge of Polymeric flocculant Solid floccules are


(colloidal suspension) suspended particles is causes that neutral easily caught by
neutralised in ZPM. particles join together filter media.
The zeta potential keeps
to create solid
fine particles dispersed
floccules.
in water.

EN 45
46 EN
EN 47
USER MANUAL

ASIN AQUA Home


EN

www.asekopool.com