ASIN Aqua Home Manual
ASIN Aqua Home Manual
ASIN Aqua Home Manual
INTEGRATED
VS PUMP
CONTROL
www.asekopool.com
General safety information
This user manual contain basic information that should be observed during assembly, start-up,
operation, and maintenance. Therefore, this user manual must be read by installers and operators
prior to assembly and start/up, and must be accessible to every user of this unit. Additionally, all
further safety information in this document must be observed. Read and follow all instructions. In
order to minimize the danger of injury, do not allow children to use this product. Non-compliance
with safety information can result in hazards to persons, the environment and the equipment.
Non-compliance with safety information will result in a forfeit of any potential right to damage
compensation.
• The system operator must ensure compliance with the required qualification level.
• Any and all work may only be performed by correspondingly qualified personnel.
• Access to the system must be prevented for insufficiently qualified persons, e.g. via access codes
and passwords.
• Design your installation such that uncontrolled dosage is not possible in the event of a probe failure
or other errors, and/or such that uncontrolled dosage is recognized and halted before damage is
incurred.
• Uncontrolled overdose of chemicals can cause harm to health and property. Even though the device
contains a number of security elements can not be ruled out that in case of failure of the measuring
probes, or the whole device may result in overdose of chemical agents. Install the equipment so
that uncontrolled overdose of chemicals was not possible and that uncontrolled overdose has been
detected in time before causing any harm. It is necessary to use chemicals in such quantities that an
overdose will not cause dangerous concentration of chemical agents. Do not use chemicals in too
large packages or with too high concentration.
2 EN
Use of new functions
Because of the continued development, a ASIN Aqua® unit may contain functions, which are not
completely described in this version of the user manual. The use of such new or extended functions
without a profound and secure understanding by the operator may result in malfunctions and severe
problems. Potential consequence: Injury, heavy material damage.
• Make use of the integrated help function of the ASIN Aqua® to get
detailed information on functions and their parameter settings.
W A R N I N G : Never mix the pH agent with the chlorine agent. When carrying out maintenance on
the clear plastic tubes or valves always rinse with clean water to prevent mixing of the pH and chlorine
agents.
EN 3
What is in the box
Suction tube weight 4 pcs Wrench socket for probes Dowels PE Tube 1/4” (6.35 mm)
#12023 #13046 and screws transparent 15m #12008
4 EN
Available optional accessories
Inserting DN50 plug Pressure-type level sensor External touch display
1/4” threaded #12134 #12086 #12048
Volume 10 kg Bottle 1 kg
BALANCER #13039 MAGNESIUM #13039 SUPER CHLOR #13120
EN 5
ASIN AQUA Home
ASIN AQUA Home is an advanced system for pool water treatment and
pool technology management. The pool water treatment with chlorine or
chlorine-free disinfection, precise pH management, boosted by dosing of
Algaecide and Flocculating aid assure the crystal-clear water of your pool by
use of the lowest necessary amount of chemical aids. The Pool Technology
Management functions automate the operations of your pool and minimize
the requirements for manual maintenance. The touchscreen display shows
all information about water quality and allows easy setup of the entire
system. With internet connectivity, you can monitor your pool parameters
through a mobile or web application.
OXY Pure
Active oxygen for chlorine-free technology ASIN AQUA HOME OXY. Active
oxygen in the combination with precise pH management, dosing of algicide
and FLOC+C maintains clean and crystal-clear water without the use of
chlorine.
ALGICIDE dosing
The effective polymeric biocide protects water against algae, fungi, moulds
and bacteria.
FLOC+C dosing
FLOC+C contains flocculation and coagulation components. Its continual
dosing improves filtration capability of removing even the smallest impurities.
To increase the effectivness of FLOC+C use coagulation mixer.
6 EN
Pool technology Switching BOTTOM / OVERFLOW
management At the set times of the TIMER, water flows through the
OVERFLOW (the relay is activated).
Outside the set times of the TIMER, water flows through
Filtration Time Control the bottom drain (relay deactivated).
Daily, automatic start of the filtration system in individual- The pool cover does not affect the BOTTOM / OVER-
ly preset periods. FLOW switching.
During filter backwashing, water flows through the BOT-
Water Level - Refilling TOM DRAIN.
In case of an alarm LEVEL TOO HIGH the flow will be
System can be programmed to control four different
switched to OVERFLOW until the alarm level expires.
water levels at your pool and switch the water refilling
or automatically use the excessive water for filter This function requires optional 3-way Besgo valve.
backwash. Requires optional level sensor.
Pool cover position (relay closed)
Filter Backwashing If the pool cover is closed during the set TIMER times,
the speed of the VS pump will automatically change to 1
The system can control the filter backwash and set
(LOW).
specific time periods to perform the filter backwash
automatically. This function requires an optional 5-way
Besgo valve. Control by External touch display
ASIN AQUA can be monitored and controled by external
Smart Heating Control touch display (this function requires an optional External
touch display #12048).
The system is equipped by intelligent control of preset
water temperature. It can switch and control the heating
(solar heating, electrical heating, gas heating, Programmabel relay
heat exchanger) by logic of integrated smart heating ASIN AQUA has one integrated programmable relay to
functions. control an extra accessory.
EN 7
ASIN AQUA Home Installation
The ASIN AQUA must be operated in indoor environment with a temperature
range of +5 to +40 °C, and the relative humidity must not exceed 70%. Direct
sunlight, high humidity, and dust may damage the ASIN AQUA.
• Before installing, ensure that pool water is chemically clean and without
40 °C
max.
CHLORINE pH ALGICID FLOCC
dirt.
5 °C
min.
Install the mounting rail and attach the ASIN AQUA to the wall. Choose a lo-
cation with a free space of at least 40 cm in all directions, and a height above
the floor must not be higher than 150 cm.
• The vertical distance between ASIN AQUA and the bottom of containers
must not exceed 2m.
40 cm • The maximum distance from injection valves to peristaltic pumps must
not exceed 8m.
18,5 cm 18,5 cm
max 8 m
max 2 m
8 EN
Installing the Probes
1. Carefully insert the pH, CLF or REDOX probe into the housing.
After probes have been inserted, slightly tightened and connectors have
been connected, ASIN AQUA Home is ready for connection to the water
system of your pool.
WARNING: Only hand tighten the probes or use the plastic wrench socket
for probes. Do not use pliers or steel wrench.
pH probe
housing #12013
CLF or Redox
probe housing
#12013
EN 9
FROM BOTTOM OUTPUT
FROM SKIMMER
INLET
3-WAY BESGO SAMPLING POINT
FLOWMETER
1
SUPPLY
WATER
MEASURED
3
OUTPUT 4
INLET
PUMP VS
COAGULATION MIXER
CHLORINE
WASTE
pH
ALGICID
5-WAY BESGO
FLOCC
FILTRATION
4-WAY BESGO
TO SOLAR
FROM SOLAR
2
DRAINAGE
WATER
MEASURED
HEATING
TO POOL
Pool Water Connection Measuring Water
valve #12005
Screw the measuring water valve in the glue head D50 with thread G1 / 4
“#12134, glued to the T-piece. Tighten the measuring water valve into
the head by hands only. Do not use pliers or other tools. Glue head
D50 with
thread 1/4“
#12134
1 Connect the MEASURED WATER SUPPLY to the pipe behind the pump,
and before the filter and before the coagulation mixer.
Connect the MEASURED WATER DRAINAGE to the pipe behind the filter
2
and behind the heating or into the overflow tank or skimmer. T-joint
To connect the measured water to the ASIN AQUA use PE tube 1/4 “(6.35
mm) #12008, which is part of the packaging.
90°
WARNING
Cut the PE tube at an angle of 90 ° to ensure tight joints. The cut must be clean.
Use special pliers #13325 to cut plastic tubes. Do not use common scissors or
knives!
The measured water is easily connected to ASIN AQUA using the Speedfit
push-in fitting.
Water valve
CONNECTION Push the connecting pipe into the Speedfit fitting fitting CONNECTION
and pull out the hose to secure.
DISCONNECTION
Once connected, ASIN AQUA is ready to measure disinfectant content and
pH value in your pool.
CS 11
FROM BOTTOM
12
FROM SKIMMER
CS
Max 2 m
3-WAY BESGO SAMPLING POINT
3
FLOWMETER
PUMP VS
COAGULATION MIXER
Max 8 m
CHLORINE
1
pH
WASTE
ALGICID
5-WAY BESGO
FLOCC
FLOC+C
4
FILTRATION
Max 8 m
4-WAY BESGO
TO SOLAR
ALGICID
pH MINUS
FROM SOLAR CHLOR PURE
OXYPURE
HEATING
2
TO POOL
Pool Chemicals
Connection
Plug with
Screw the injection valve in the glue head D50 with thread G1 / 4 “ #12134, D = 50 with
glued to the T-piece. Tighten the injection valve into the head by hands thread 1/4“
only. Do not use pliers or other tools.
Connect the FLOC+C INJECTION VALVE to the pipe before the coag-
1 T-joint
ulation mixer and before the filter and after the MEASURED WATER
SUPPLY.
To connect reagents from cans to the ASIN AQUA and from the ASIN AQUA
to the injection valves use PE Tube 1/4 “(6.35 mm) #12008, which is part of
the packaging.
WARNING
Ø 6,35 mm
Ø 1 mm
Cut the PE tube at an angle of 90 ° to ensure tight joints. The cut must be clean.
3
Use special pliers #13325 to cut plastic tubes. Do not use common scissors or
knives!
4 PUMP CONNECTION Connect the can with the left (suction) connector of
the pump using a PE tube from the can.
WARNING
NEVER CONNECT pH minus reagent to disinfection pump or disinfectant
to pH pump! In the case of a cross-connection, after ten doses ASIN AQUA
displays an error message. Repair the piping installation and then you can
continue to operate your ASIN AQUA.
CS 13
Accessories Connection
POWER SUPPLY
ZDROJ NAPÁJENÍ
230 V ~ 50 Hz
230 V ~ 50 Hz
L N L N
36 37 38 39 40
230 V ~ 50 Hz
1
2
3
Solenoid valve
Solenoid relé
dopuštění
filling max 1A
(+)
Bottom B.wash
Besgo
Besgo 5 valve
W 5W
Filter
Praníbackwash
filtru
Besgo 3
Besgo W 3W
valve
Dnová
OFF výpust
Bottom (+)
ON Overflow
L
Heating
26 27 28 29
Topení relay
Heating
L
Bezpotencionální RELAY
POTENTIAL-FREE
relé
Max 1 A, Max 230 V
Timer
Solar / Timer
Bez funkce
21 22 23 24 25
Speed
Speed 33 HIGH
HIGH
3
Speed
Speed 22 MEDIUM
MEDIUM
2
Řízení
VS pump
Speed
Speed 11 LOWLOW VS PUMP CONTROL
variabilního
1
Speed
čerpadla
Speed 00 STOP
STOP
0
COM COM
COM
T800mA
ROLLER
Roleta SHUTTER
POSITION
9 10
Cover
Roller shutter
Bazénová roleta
position
POTENTIAL-FREE
Sepnuto – zavřená RELAY!
8
Level
Water level
Hladinoměr Rozepnuto – otevřená
sensor Connected – cover close
7
Air
Teploměr vzduch
thermometer
5
T water
11 12 13 14
RS 485 Display
Water
Teploměr voda
thermometer
3
SENSOR INPUT 4 – 20 mA
Vstupy
2
Flow
Průtokoměr
Flow detector
1
External display
Externí display
13 14 11 12
External
B
Display
GND +12V
14 EN
VS pump connection
WARNING
Always check the connection according to the current user manual of your pump
manufacturer.
Speed
TYP A TYP B TYP C
COM S1 S2 S3 STOP COM S1 S2 S3 S4 COM S1 S2 S3 STOP
n1 ON OFF OFF OFF n1 ON OFF OFF OFF n1 ON OFF OFF OFF
n2 OFF ON OFF OFF n2 OFF ON OFF OFF n2 OFF ON OFF OFF
n3 OFF OFF ON OFF n3 OFF OFF ON OFF n3 OFF OFF ON OFF
S OFF OFF OFF ON S OFF OFF OFF ON S ON ON ON OFF
Relay status
HAYWARD (older type) TYP C
TYP A DI4
21 22 23 24 25
Speed 3
3
DI3
Speed 2
2
VS pump
SPECK TYP A UWE EO PM Speed 1
DI2
TYP A
1
N3 DI1 CONNECTED
NOT
Speed 3
0
30
21 22 23 24 25
Speed 3 Speed
3
N2 C
SPEED 3
COM COM 2
21 22 23 24
Speed 2 Speed
2
2
VS pump
VS pump
N1 SPEED 2
Speed 1 Speed 1
1
STOP SPEED 1
Speed 0 Speed 0
0
GND GND
COM COM COM COM
21 22 23 24 25
Speed 3 Speed 3
3
N2 DI2
Speed 2 Speed 2
2
2
VS pump
VS pump
N1 DI1
Speed 1 Speed 1
1
STOP DI4
Speed 0 Speed 0
0
GND C
COM COM COM COM
TYP B
PENTAIR TYP B DAB E.SWIM - E.PRO TYP B
OVERDRIVE 11
21 22 23 24 25
21 22 23 24 25
Speed 3 Speed 3
3
N3 8
Speed 2 Speed 2
2
2
VS pump
VS pump
N2 7
Speed 1 Speed 1
1
N1 6
Speed 0 Speed 0
0
+5V 3
COM COM COM COM
TYP C
HAYWARD (older type) TYP C
DI4
21 22 23 24 25
Speed 3
3
DI3
Speed 2
2
VS pump
DI2
Speed 1
1
DI1
Speed 0
0
C
COM COM
EN 15
Power Supply
Connection to the mains:
2. Connect filtering device to the ASIN AQUA Home switched socket outlet
Installation must be
(filtration power supply - max. 1.4 kW / 230 VAC).
protected by a residual
current device (RCD). 3. Connect the 230 V / 50 Hz mains cable to ASIN AQUA Home (on the right
side). The mains socket outlet must be protected by a residual current
device (RCD).
Residual After Device has been switched on, the display will come on and the ASIN
CHLORINE pH ALGICID FLOCC
current
Proudový AQUA Home starting screen will appear.
RCD device,
chránič
30 mA
30 mA Disconnection from the mains:
230
230 VV / 50
/ 50 Hz Hz
1. Change the mains switch over to the OFF position.
Max.
Max 1,41,4
kW kW
2. Disconnect the ASIN AQUA Home mains cable from the 230 V / 50 Hz
230 v~
230 V~ socket outlet.
3. Disconnect the filtering unit mains cable from ASIN AQUA Home.
16 EN
Installation Test
WARNING: Any obstacles, bubbles or leaks in the connecting tube will
prevent ASIN AQUA Home from correct operating. The clear plastic tube
allows you to monitor flow of liquid to the injecting valves.
Test
In the “Relay Test” menu, start pumps one by one and while they are
running, check tightness of all the PE tube connections. Check the injecting
valves for blockage and air bubbles in the PE tube.
DON’T FORGET! After you complete the test, stop all accessories in
the menu. Do not dose in this step!
2.
If bubbles occur here, the
1. pump sucked air. Repair the
Monitor level in the connection - disconnect the
transparent plastic tube. tube, cut the end carefully at
a 90° angle, and plug it back.
3.
Check tightness of all the
connections.
EN 17
Touch screen description
Home Screen
The home screen displays measured values, required values and status
information.
E.g. click on the Chlorine to enter the setting of the required chlorine value.
Required Value.
Measured Value.
ON indicates the current status of ON - filtration runs according to Enter the settings.
filtration. The Timer allows to set the preset periods.
filtration periods. NONSTOP 24 h – filtration runs
continuously for 24 hours.
18 EN
Settings
OFF - function is
switched off
Value Settings
Decrease the value. Increase the value. Save the set value
EN 19
Configuration
Pool Volume
To ensure the correct function of ASIN AQUA, enter the correct volume of
your pool. Calculate your pool volume in m3:
Length (L) times width (W) times depth (D) is volume (V) - (L × W × D = V).
WARNING: The pool volume has effect on the maximum safe dose, enter
the value correctly.
Filtration Timer
Filtration timer can be set to NONSTOP 24 hours operation, or to one or two
filtration periods.
When the relay switches ON, the BESGO valve switches to the required
position with the pressure of water or air and performs the Filter backwash.
See the BESGO manual.
20 EN
Smart Heating
EN 21
Winter mode
Activating this function set the device into the special Winter mode. This
mode prevents the pool water from freezing and keeps the water clean with
dosing of algaecide.
Outside of the filtration timer the filtration pump remains OFF (VS pump
SPEED 0) but is automatically activated for the period of 15 minutes when
WARNING: DO NOT the outdoor temperature drops below 0°C.
USE HEAT PUMP IN THE
• If, after the period of 15 minutes, the water temperature is under the set
WINTER MODE!
temperature of 2°C, the filtration pump stays ON, and the heating is acti-
Winter mode does not vated until the water temperature exceeds the set temperature.
protect the heat pump from
• If, after the period of 15 minutes, the water temperature is higher than
freezing.
set 2°C, the circulation pump is turned OFF.
Disconnect the heat pump
If the outdoor temperature stays below 0°C this cycle is repeated every
and winterize it separately.
6 hours.
Follow the heat pump
manufacturer‘s manual. When using the Winter mode without the outdoor air thermometer, the
system acts as it always detects 0°C outdoor temperateru.
Warning: Winter mode must not be used with the heat pump. The entire
system is programmed that it does not protect the heat pump against
freezing in the event of severe frosts. The winter mode can only be used in
fully inground (thermally isolated) pools with filtration technology located in a
in a non-freezing environment. The winter mode cannot be used for above-
ground pools
22 EN
Hoch – Alarm
Nachfüllen – OFF
Aktuell
Niveau Nachfüllen – ON
Niedrig – Alarm
Level sensor - Level Monitoring and Automatic
Refilling
The water level is monitored using a pressure-type level sensor, which is
easy installed by inserting the probe into the buffer tank or the blind nozzle
of skimmer pools. ASIN AQUA monitors four different levels, which can be
set in centimeters in the water level meter menu.
Setting:
High level ALARM - too much water in buffer tank
After this level is reached, following actions may start:
1. If the automatic filter backwash is enabled, one backwash cycle starts
Hoch level
High – Alarm
– Alarm and drains the waste water.
2. If the automatic filter backwash is not enabled, the relay 19 switches
Nachfüllen
Filling – OFF
– OFF
Actual
Aktuell on (filter backwash) for the period of time until level is OK. The second
Level
Niveau Nachfüllen
Filling – ON– ON
circulating pump or automatic drain valve can be connected to this relay.
Niedrig
Low – Alarm
level – Alarm Refilling OFF - required level
Niveau00cm
Level cm Refilling stops
Refilling ON - level at which refilling starts
Refilling starts after if the water level stay permanently at least for
10 seconds below this value (in order to prevent oscillating)
Low level ALARM
Circulation (filtration) pump shuts off
Flow detection
The flow detector detects flow of measured water. Dosing of chemicals will
take action only if the water flow to probes is detected.
Delay
Delay time after dose is time for which ASIN AQUA does not dose and wait
for the response of probes. The average response time is 4 to 10 min, at SPA
1 to 10 min.
Delay time after start of the filtration pump (upon timer switching on) is
time after start for which ASIN AQUA does not take any action and waits for
stabilization of a signal from probes.
Concentration pH –
If you use the original ASEKO Pool & SPA chemicals keep the preset value.
In case of use of non-original chemicals adjust concentration according to
data on the label of a chemical used.
EN 23
VS variable speed pump control
In the settings, select the type of your variable speed pump.
ASIN AQUA allows you to use 4 speeds of your VS pump.
Speed 0 (OFF)
Speed 1 (LOW) for economical filtration outside the TIMER.
Speed 2 (MEDIUM) for filtration during TIMER periods.
Speed 3 (HIGH) during filter backwash.
Individual speeds are set directly on the pump according to the pump
manufacturer’s manual.
Programmable relay
Solar heating
When using both solar heating and the heat pump simultaneously, SMART
HEATING gives the option to automatically disable the heat pump, utilizing
only solar absorbers to optimize electrical consumption.
• In the HEATING CONTROL menu go to the Heating at Outdoor Tem-
perature (above or below) and check the HEAT BELOW option. Set the
temperature between 30 to 40 °C.
WARNING: With use of solar collector set the filtration timer through all the
hours of sunshine to prevent overheating of the solar collector.
Timer
24 EN
Other automatic functions
BESGO 3-way
Switch of pool water flow - Besgo 3w
#83140 OVERFLOW / BOTTOM DRAIN
During set filtration timer periods, water flows through the OVERFLOW (relay
is activated).
Outside the set filtration timer periods, water flows through the BOTTOM
DRAIN (relay deactivated).
During filter backwash, water flows through the BOTTOM DRAIN.
An alarm WATER LEVEL TOO HIGH switches the water flow to the OVERFLOW
until the alarm expires.
The pool cover has no effect on the BOTTOM / OVERFLOW switching.
The three-way BESGO should be connected in a way that when the
solenoid valve is not powered, water flows through the BOTTOM.
EN 25
Choosing the type of probe or
the type of time dosing
1. CLF free chlorine probe for ASIN AQUA HOME CLF
Free chlorine measurement, CHLOR PURE dosing
Commissioning procedure
The water in the pool must be clean without any additives.
Ideally fill the pool with fresh water from the water main.
• If you have the CLF probe, set the disinfection to 0.0 mg/l.
If you have the REDOX probe, set the disinfection to 000 mV.
If you have the Time dosing set the required value of OXY Pure to 0 ml/m³/day.
N CLOSE
CLOSE
Close the water supply to the probes
ASIN AQUA displays no flow to the probes.
26 EN
Before opening the water supply to the probes
Wait 24 hours.
OPEN
OPEN Open the water supply to the probes
CLOSE
Warning No flow to probes turns off automatically.
pH Setting
Considering that the ASIN AQUA Home water treatment system is efficient in
the broad pH range, it is recommended to enter the required pH value equal
to pH value of water you refill or slightly lower.
Required pH value = refilled water pH value (in the range from 6.8 to
7.5)
pH may change during operation but if it is in the range from 6.8 to 7.5 you
do not have to change this setting.
ALGICIDE Setting
A sufficiently effective dose for most pools is 10 ml/m3 per day. If green
algae appear in the pool, you can increase the dose. After algae have
disappeared, the dose can be returned to 10 ml.
FLOC+C Setting
The FLOC + C dose is calculated from the amount of circulating water, which
flows through the filtration.
Based on your circulating pump power (in m³ per hour), adjust the FLOC + C
dose value. E.g. with the circulation pump with power of 10 m³/h set the
FLOC + C dose to 10ml/h.This value ranges from 10 to 40 ml per hour for
most private pools.
EN 27
If you use the CLF probe
For the correct functionality of the CLF probe you must observe the
following conditions:
WARNING
Befor proceeding to setting of the required values, keep the probe connected
to the water for at least 1 hour, ideal 24 hours, to stabilize its measurement.
Repeat the measurement after the water in the pool is mixed thoroughly
and the value shown on the ASIN AQUA is stable.
Repeat the process until the chlorine concentration in pool water
matches your required value then set the correct required value
according to the table. Additionally, you can perform the calibration of
the CLF probe (see the chapter CLF Probe Calibration).
• HIGHER than the required value shown on the ASIN AQUA Home
display - you can calibrate the CLF probe (see the chapter CLF Probe
Calibration).
NOTIFICATION:
Fix the low chlorine value in pool water by increasing required disinfec-
tion value on the display of the unit.
28 EN
If you use the Redox probe
For the correct functionality of the REDOX probe, you must observe
the following conditions:
WARNING
Befor proceeding to setting of the required values, keep the probe connected
to the water for at least 1 hour, ideal 24 hours, to stabilize its measurement.
Use the tester to check if the chlorine content in pool water is within the
range of 0.5 - 1.2 mg/l.
Fine-tuning
Use the colorimeter or Pool Tester to measure the chlorine value of the pool
water. If the manually measured chlorine value in pool water is:
EXAMPLE:
The chlorine value in the pool water is 0.3 mg/l - the displayed value is
650 mV. If you want to increase the chlorine value to 0.5 mg/l. You have to
increase the preset value of the redox by 20 mV to 670 mV.
NOTE:
The relationship of Redox potential and chlorine value in pool water cannot
be determined by the exact table. The correct value of the Redox must be
observed by several check measurements.
EN 29
Safety Functions
Operation
In standard automatic mode, only these 3 screens are displayed.
Home screen
30 EN
In Operation Measurement and
Calibration
pH Probe Calibration
Calibration is not possible
When pH is being measured in operation, there may be a difference between
when the new value differs
the value measured by ASIN AQUA and the actual pH value in water. Proceed
by more than 1 from the
to the calibration.
non-calibrated value.
1. With a buffer
• Close the water supply to the probes.
• Remove the probe from ASIN AQUA Home :
rinse the probe with clean water and wipe it.
• The probe must remain connected to the device via the cable. Dip the
probe in the calibration buffer and after the value displayed on ASIN
AQUA is stable, enter the buffer value into the pH Probe Calibration
Photometr menu.
#13076
EN 31
CLF Probe calibration
Do not calibrate the probe until the water in the pool is thoroughly mixed
and the value displayed on the ASIN AQUA is stable.
Perform calibration of the CLF probe when the manually measured value
of free chlorine is equal to or higher than the value you are calibrating to.
Photometr
#13076
0,4
0,4 0,7
Calibration restrictions
The CLF probe cannot be calibrated if the output signal is less than 20 mV.
The CLF probe can only be calibrated in the CL range from 0.3 to 5.0 mg / l.
32 EN
#12177 OX tester Adjustment of OXYPURE Active Oxygen Dose
When using chlorine-free technology ASIN AQUA HOME OXY the optimum
OXYPURE concentration value is from 50 to 100 mg.
From time to time check this value by measuring with the OX tester and
adjust the dose in the menu, if required.
Stabilizer in water
The water in the pool must be clean without any additives.
Ideally fill the pool with fresh water from the water main.
BALANCER #13039
Alkalinity
Alkalinity volume in the water should range from 80 to 120 ppm. Alkalinity
stabilizes the pH and reduces its consumption. To increase the Alkalinity in
the water, use Pool & SPA BALANCER (#13039).
Cyanuric Acid
The value of Cyanuric acid must be 0 ppm. Cyanuric acid greatly diminish
the effectiveness of chlorine, making it difficult to accurately measure and
control its concentration. If the presence of cyanuric acid is detected, fill the
pool with fresh water.
EN 33
Maintenance
#12073 Replacement hose
for the pump PP 60 To ensure the optimum efficiency, perform visual checks and maintenance
of ASIN AQUA on a regular basis.
• Turn the pump cover cassette anticlockwise and take it out of ASIN
AQUA Home.
• Place the cover cassette back on ASIN AQUA Home and turn it clockwise
to lock it.
• Use new nuts, which are part of the replacement tube set, for connection
of the PE tube.
In case of private pools, replace injection valve rubber bands #13087 every 2
years. In case of public pools, replace #12005 every year.
34 EN
Fuse Replacement
Fuse T 125 mA #13078
Fuse T 800 mA #13096
Fuse T 6,3 A #13099 T125 A Fuse
Fuse protecting the inner electronics. In case of its burnout, check the inner
electronics.
T800 mA Fuse
Fuse protecting external sensors. In case of burnout of this fuse, check the
level sensor, flow detector, and external display.
T6,3 A Fuse
Fuse protecting the device, including the BESGO valves and circulation
pump.
pH Probe Testing
pH - Buffer 7,00 #12065
Take the probe out of ASIN AQUA housing and clean it from impurities.
Check for visible mechanical damage on the probe.
Measure the pH value and ensure it falls within the tolerance range of +/-
1.0. For example, if the water pH is 7.2 and the probe measures 7.9, it is in
tolerance, the probe is considered okay.
Conduct a test with clean water without chlorine (standing for 24 hours)
and ensure the signal is lower than 20 mV. Otherwise, send the probe for
inspection.
Redox Buffer 475 mV #12063
REDOX Probe Testing
Take the probe out of ASIN AQUA housing and clean it from impurities.
Check for visible mechanical damage on the probe.
Ensure that the redox probe’s sensitivity does not exceed -12% and that it
measures above 420 mV at the buffer value of 475 mV.
EN 35
Winterizing - storage during
winter
If you want to operate ASIN AQUA in Winter mode, go to the chapter Con-
figuration - Winter mode. If you do not want to operate the device in Winter
mode, it is necessary to winterize the device and all its components (store
them when not in use).
2. Disconnect the filter unit’s mains cable from the ASIN AQUA and store
the filtration pump according to manufacturers manual.
3. Disconnect all accessories from the ASIN AQUA motherboard and store
them according to manufacturers manual.
36 EN
Winterizing of probes
#12154 Probe storing sump
Winterizing of pH and Redox probe
Remove the probe from the housing, dry it with a paper towel and place it in
a storage sump filled with a special storage liquid. See probes manual at the
website manuals.asekopool.com.
Remove the probe from the housing, unscrew the membrane and empty the
electrolyte from it. Do not put the membrane back on the probe and store
them separately in a dust-free place where the temperature is between +5
- +40 °C and the humidity does not exceed 70% throughout the winter. See
probes manual at the website manuals.asekopool.com.
40 °C
max.
5 °C
min.
40 cm
40cm 40 cm
40 cm
150 cm
EN 37
Internet connection
The LAN connector is to be connected to the domestic router.
Data are sent in the intervals of 10 seconds to the address
pool.aseko.com, the route must not be blocked by the firewall.
If you are not able to setup the connection by your own ask your IT specialist
for help.
Home network
Connect the ASIN AQUA Home to your router via LAL cable.
Mobile network
In case you have no direct internet access you can use the data transmis-
sion over the mobile network. Connect the ASIN AQUA Home to your mobile
network router via LAN cable.
Wifi connection
If you install the ASIN AQUA Home in place where is no access to your pri-
vate network by wired connection but your Wifi has enough signal, you can
connect the ASIN AQUA Home to your Wifi by use of Wifi extender.
38 EN
LAN
INTERNET
Home network
3G / LTE INTERNET
WIFI EXTENDER
Wifi extender
INTERNET
Powerline
via 230 V
socket outlet 230 V
INTERNET
EN 39
Aseko web services
Pool live
The internet connection allows you to use the Pool Live mobile application
and monitor your pool on mobile devices wherever the internet connection is
available.
After you connect the ASIN AQUA to the internet download the Pool Live
application to your smartphone. Application is available for iOS and Android
operation systems.
App’s main screen, after opening, will ask for typing your ASIN AQUA serial
number.You can add more units to the Pool live app.
40 EN
https://pool.aseko.com
The web application for detailed monitoring of the pool water quality by
means of well-arranged graphs. It shows all the measured parameters as
well as ASIN AQUA Home actions up to 30 days back.
This application is giving you the detailed information of the pool status and
detailed review of all events, taken actions and act levels of monitored items
up to 30 days back.
Transparent graphic environment of chart lines is giving fast report and you
can easily see interconnection of monitored values.
EN 41
Error messages
running. If so, check the hose inside the pump for • Check condition of the extraction valve and the
damage or breakage and replace it, if required. closing valve and their seals, for being clogged and
their closed position.
Injection valve clogged
• Impassable spray valve. Probe out of service
Check the valve for being clogged with impurities or • Measure pH using the hand tester. If the pH value is
deposits or the rubber seal for being damaged. too low, a respective agent was overdosed due to an
• Failure of dosing pump. Check whether pump is incorrect probe function (provided that other reasons
If so, check the hose inside the pump for damage or • Take the probe out and check it for mechanical
breakage and replace it, if required. damage.
42 EN
Too rapid pH change
Too rapid change of pH is usually caused by refilling water directly to
the skimmer. If such rapid change of pH occur, ASIN AQUA Home stops
controlling pH for two hours.
After pH has been stabilized or two hours have elapsed, ASIN AQUA Home
changes over to the normal mode.
EN 43
Bottom
31
30 31
Besgo 3 W
Dnová výpust
30
(+)
L
Externes touchscreen display
Heating
26 27 28 29
Topení
L
Bezpotencionální
relé
Timer
Bez funkce
The external display shows
1. P
ool
3 water
HIGH parameters:
21 22 23 24 25
Speed
3
Temperature,
Speed 2 MEDIUM pH value, redox potential or chlorine concentration.
2
Řízení
VS pump
Speed 1 LOW variabilního
1
2. Parameters of the air in the pool area:
čerpadla
Speed 0 STOP
0
relative humidity and temperature.
COM COM
The setpoints can be set on the ASIN AQUA device and a probe calibration
Salinity
19 20
T800mA
10
9 10
Cover
Bazénová roleta
9
11 12 13 14 15 16 17 18
8
8
Level
Hladinoměr Inputs
RS 485
7
7
6
6
T out
Teploměr vzduch
5
5
T water
RS 485 Display
4
4
Teploměr voda
3
3
2
2
Flow
Průtokoměr
External display
1
1
RS 485
Externí display RS 485
13 14 11 12
A
B
GND +12V
44 EN
Enhancement of filtering efficiency
- - - -- - + - - + - -
- - - + + +- ++ + +
- - -- - + + -
- -- -
- - -
- -
-
+ + +
- - - + + -- -- +
- - - - -
+ +
- - -- - - ++ - - + - -
- - - - - + - - + - - - + ++ +- +
- -- - - - - - - -+
- - - +
+ + + +
- - - - ZPM + +
+
-
- - - -- - - + -
+
-
FROM POOL
TO POOL
(Zeta Potential +
- -- Mixer) + - - +- - -+
+
- - +- +
+
EN 45
46 EN
EN 47
USER MANUAL