ATS22C41Q Schneider Electric
ATS22C41Q Schneider Electric
ATS22C41Q Schneider Electric
Main
Range of product Altistart 22
Product or component Soft starter
type
Product destination Asynchronous motors
Product specific appli- Severe and standard applications
cation
Component name ATS22
Network number of 3 phases
phases
Power supply voltage 230...440 V (- 15...10 %)
Motor power kW 220 kW at 440 V
220 kW at 400 V
110 kW at 230 V
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Factory setting current 388 A
Power dissipation in W 177 W for standard applications
Utilisation category AC-53A
Type of start Start with torque control (current limited to 3.5 In)
Icl nominal current 410 A (connection in the motor supply line) for stan-
dard applications
IP degree of protection IP00
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Complementary
Assembly style With heat sink
Function available Internal bypass
Power supply voltage limits 195...484 V
Power supply frequency 50...60 Hz (- 10...10 %)
Network frequency 45...66 Hz
Device connection In the motor supply line
To the motor delta terminals
Control circuit voltage 220...230 V -15...10 % at 50/60 Hz
Control circuit consumption 20 W
Discrete output number 2
Discrete output type (R2)Relay outputs 230 V running, alarm, trip, stopped, not stopped, starting,
ready, C/O
(R1)Relay outputs 230 V running, alarm, trip, stopped, not stopped, starting,
ready, C/O
Minimum switching current Relay outputs 100 mA at 12 V, DC
Maximum switching current Relay outputs 2 A at 30 V, DC inductive load, L/R = 7 ms
Relay outputs 2 A at 250 V, AC inductive load, cos phi = 0.4, L/R = 20 ms
Relay outputs 5 A at 30 V, DC resistive load, cos phi = 1
Relay outputs 5 A at 250 V, AC resistive load, cos phi = 1
Discrete input number 3
Discrete input type (LI1, LI2, LI3)logic 5 mA 4.3 kOhm
Discrete input voltage 24 V (<= 30 V)
Discrete input logic (LI1, LI2, LI3)positive logic state 0 < 5 V and < 2 mA state 1 > 11 V and > 5 mA
Output current 0.4...1 Icl adjustable
PTC probe input 750 Ohm
Communication port protocol Modbus
Connector type 1 RJ45
Communication data link Serial
Physical interface RS485 multidrop
Mar 9, 2013
1
Transmission rate 4800, 9600 or 19200 bps
Max nodes number 31
Protection type Thermal protection on starter
Thermal protection on motor
Phase failure on line
Marking CE
Type of cooling Forced convection
Operating position Vertical +/- 10 degree
Height 425 mm
Width 206 mm
Depth 299 mm
Product weight 33 kg
Environment
Electromagnetic compatibility Voltage/Current impulse conforming to IEC 61000-4-5 level 3
Immunity to radiated radio-electrical interference conforming to IEC 61000-4-3
level 3
Immunity to electrical transients conforming to IEC 61000-4-4 level 4
Electrostatic discharge conforming to IEC 61000-4-2 level 3
Damped oscillating waves conforming to IEC 61000-4-12 level 3
Conducted and radiated emissions conforming to IEC 60947-4-2 level A
Standards EN/IEC 60947-4-2
Product certifications CCC
CSA
C-Tick
GOST
UL
Vibration resistance 1.5 mm (f = 2...13 Hz) conforming to EN/IEC 60068-2-6
1 gn (f = 13...200 Hz) conforming to EN/IEC 60068-2-6
Shock resistance 15 gn for 11 ms conforming to EN/IEC 60068-2-27
Noise level 56 dB
Pollution degree Level 2 conforming to IEC 60664-1
Relative humidity <= 95 % without condensation or dripping water conforming to EN/IEC 60068-2-3
Ambient air temperature for operation > 40...< 60 °C with current derating 2.2 % per °C
-10...40 °C without derating
Ambient air temperature for storage -25...70 °C
Operating altitude > 1000...< 2000 m with current derating of 2.2 % per additional 100 m
<= 1000 m without derating
Offer Sustainability
Sustainable offer status Not Green Premium product
RoHS
Compliant - since 0939 - Schneider Electric declaration of conformity download
declaration of conformity
Product environmental profile Available Download Product Environmental
Product end of life instruction Available Download End Of Life Manual
2
Product data sheet ATS22C41Q
Dimensions Drawings
Frame Size E
Dimensions
3
Product data sheet ATS22C41Q
Mounting and Clearance
Precautions
Standards
The Altistart 22 soft starter is compliant with pollution Degree 2 as defined in NEMA ICS1-1 or IEC 60664-1.
For environment pollution degree 3, install the Altistart 22 soft starter inside a cabinet type 12 or IP54.
DANGER
Air Circulation
Leave sufficient free space to help the air required for cooling purposes to circulate from the bottom to the top of the unit.
Overheating
To avoid the soft starter to overheat, respect the following recommendations:
● Mount the Altistart 22 Soft Starter within ± 10° of vertical.
● Do not locate the Altistart 22 Soft Starter near heat radiating elements.
● Electrical current through the Altistart 22 Soft Starter will result in heat losses that must be dissipated into the ambient air immediately
surrounding the soft starter. To help prevent a thermal fault, provide sufficient enclosure cooling and/or ventilation to limit the ambient
temperature around the soft starter.
● If several soft starters are installed in a control panel, arrange them in a row. Do not stack soft starters. Heat generated from the
bottom soft starter can adversely affect the ambient temperature around the top soft starter.
Introduction
To help proper air circulation in the soft starter, grilles and forced ventilation can be installed.
4
Ventilation Grilles
5
Product data sheet ATS22C41Q
Connections and Schema
Power Terminal
Bar Style
a 5 mm (0.2 in)
498.75 lb.in
230 Vac control, logic Inputs (LI) 24 Vdc, 2-wire control,freewheel stop
6
Connection in the motor delta winding in series with each winding
Wiring
ATS22 soft starters connected to motors with the delta connections can be inserted in series in the motor windings.
The following wiring requieres particular attention. It is documented in the Altistart 22 Soft start - soft stop unit user manual. Please contact
Schneider Electric commercial organisation for further informations.
Example
A 400 V - 110 kW motor with a line current of 195 A (nominal current for the delta connection). The current in each winding is equal to
195/1.5 or 130 A. The rating is determined by selecting the soft starter with a permanent nominal current (ICL) just above this current.
7
Product data sheet ATS22C41Q
Performance Curves
Curves
A Class 10
B Class 20
C Class 30
32 s
63 s
95 s
8
Motor Thermal Protection - Warm Curves
Curves
A Class 10
B Class 20
C Class 30
16 s
32 s
48 s