You are on page 1/ 40

UBA-RC™ Series

Banknote Recycler
Integration Guide
Revision A, October 18, 2010

P/N 960-100928R_Rev. A {EDP #192691}

Issue #4088-IGE-01-00
© 2010, Japan CashMachine Co, Limited
UBA-RC™ Series Banknote Recycler Integration Guide

Issue #4088-IGE-01-00

REVISION HISTORY

Rev №. Date Reason for Update Comment

A 10/18/10 Initial Document

International Compliance
• RoHS Directives or or or or

• UL & c-UL Marks

• CE Mark

• CB Scheme
Above listed compliance are currently working toward having approval or certificate.

Copyright © 2010 By Japan CashMachine Co, Limited


This product document (hereinafter referred to as “Manual”) is fully coveredby legal Copyrights owned by the Japan
Cash Machine, Co., Ltd., (hereinafter referred to as “JCM”) under Japanese laws and foreign countries. This Manual
contains many copyrighted, patented or properly registered equipment items manufactured by JCM, that are prohibited
and illegal to duplicate, replicate or copy in whole, or in part, without the express
authorization by JCM with the following exceptions:
1. When an authorized JCM agency or distributor duplicates the Manual for sales promotion and/or service
maintenance of the product, or technical service personnel education as required; and
2. When an end user duplicates the Manual to maintain operation of the product or operate the product in general.
JCM retains all rights to amend, alter, change or delete any portion of this Manual in whole, or in part, or add items
thereto without notice regarding the product or its related products.
JCM is a registered trademark of Japan CashMachine Co, Limited. All other product names mentioned herein may be
registered trademarks or trademarks of their respective companies. Furthermore, ™, ® and © are not always mentioned
in each case throughout this publication.
UBA-RC™ Series
Integration Guide
Table of Contents
Page
TOC
1 GENERAL INFORMATION......................................................................................1
Description .......................................................................................................................... 1
UBA-RC Unit Assembly ...................................................................................................... 1
Model Number Specifications ............................................................................................. 2
Model Descriptions ......................................................................................................................... 2
Type Descriptions ........................................................................................................................... 2
Software Descriptions ......................................................................................................... 2
Precautions ......................................................................................................................... 2
User Cautions ................................................................................................................................. 2
Installation Cautions ..................................................................................................................... 2
Mounting, Dismounting & Transportation...................................................................................... 3
Preventive Maintenance ..................................................................................................... 3
Banknote Fitness Requirements ..................................................................................................... 3
Primary Features ................................................................................................................ 3
Component Names ............................................................................................................. 4
2 SPECIFICATIONS....................................................................................................5
Technical Specifications .................................................................................................................. 5
Environmental Specifications .......................................................................................................... 6
Electrical Specifications .................................................................................................................. 6
Structural Specifications.................................................................................................................. 6
3 INSTALLATION .......................................................................................................6
Installation Process............................................................................................................. 6
Cable Interconnection ......................................................................................................... 7
DIP Switch Configurations .................................................................................................. 7
Jumper Configurations........................................................................................................ 8
4 CONNECTOR PIN ASSIGNMENTS ........................................................................9
Connector Pin Assignments (Continued 1) ................................................................................... 10
Connector Pin Assignments (Continued 2) ................................................................................... 11
5 PREVENTIVE MAINTENANCE .............................................................................11
Restoring Banknotes..........................................................................................................11
Restoring Banknotes using the UBA Transport Unit ..................................................................... 11
Restoring Banknotes Directly into the Recycler Unit .................................................................... 11
Retrieving Banknotes.........................................................................................................11
Sending Retrieved Banknotes to the Cash Box............................................................................ 11
Retrieving Banknotes from the Cash Box................................................................................... 11
Retrieving Banknotes Directly....................................................................................................... 11
Dispense Settings ............................................................................................................. 12
Clearing a Banknote JAM ................................................................................................. 12
Cleaning Procedure ...................................................................................................................... 12
Sensor Cleaning Procedure........................................................................................................ 12
6 UBA-RC SENSOR LOCATIONS ...........................................................................14
7 STANDARD INTERFACE CIRCUIT SCHEMATICS..............................................15
8 OPERATIONAL FLOWCHARTS ...........................................................................16
Operation Flowcharts (Continued 1) ............................................................................................. 17
Operation Flowcharts (Continued 2) ............................................................................................. 18
Operation Flowcharts (Continued 3) ............................................................................................. 19
Operation Flowcharts (Continued 4) ............................................................................................. 20
Operation Flowcharts (Continued 5) ............................................................................................. 21
Operation Flowcharts (Continued 6) ............................................................................................. 22

P/N 960-100928R_Rev. A {EDP #192691} i © 2010, Japan CashMachine Co, Limited


UBA-RC™ Series Integration Guide

Table of Contents
Continued Page
9 VARIOUS UNIT DIMENSIONS.............................................................................. 23
UBA-RC Entire Unit Outside Dimensions......................................................................................23
10 LED DIAGNOSTIC CODES................................................................................... 25
Introduction ........................................................................................................................25
Troubleshooting Overview.............................................................................................................25
Malfunction LED Error Codes........................................................................................................25
LED Indication Conditions .............................................................................................................25
11 INTERNATIONAL COMPLIANCE......................................................................... 27
12 TECHNICAL CONTACT INFORMATION ............................................................. 28
Americas & Oceania......................................................................................................................28
JCM Global .................................................................................................................................28
Europe, Africa, Russia & Middle East ...........................................................................................28
JCM Europe GmbH .....................................................................................................................28
UK & Ireland ..................................................................................................................................28
JCM Europe (UK Office)..............................................................................................................28
Asia ...............................................................................................................................................28
JCM Gold (HK) Ltd. .....................................................................................................................28
Japan Cash Machine Co, Limited (HQ).......................................................................................28
13 INDEX .................................................................................................................... 29

P/N 960-100928R_Rev. A {EDP #192691} ii © 2010, Japan CashMachine Co, Limited


UBA-RC™ Series
Integration Guide
List of Figures
Page
LOF
Figure 1 UBA-RC Unit Assembly ................................................................................1
Figure 2 Precautionary Symbols .................................................................................2
Figure 3 Unacceptable Banknotes ..............................................................................3
Figure 4 UBA-RC Component Names ........................................................................4
Figure 5 M4 Screws Locations (Right/Left) .................................................................6
Figure 6 M4 Screws Locations (Rear & Bottom).........................................................7
Figure 7 Cable Interconnection ...................................................................................7
Figure 8 3.3V DC UBA CPU Board Bottom View........................................................8
Figure 9 Banknote Restoration Methods...................................................................11
Figure 10 Retrieving Recycler Banknotes...................................................................12
Figure 11 Clearing a Banknote JAM 1 ........................................................................12
Figure 12 Clearing a Banknote JAM 2 ........................................................................12
Figure 13 UBA-RC Sensor Cleaning Locations ..........................................................14
Figure 14 UBA-RC Photo-Coupler Circuit Interface Schematic Diagram ...................15
Figure 15 UBA-RC RS232C Circuit Interface Schematic Diagram .............................15
Figure 16 UBA-RC Bezel Circuit Interface Schematic Diagram..................................15
Figure 17 UBA-RC Operational Flowchart (Initialize)..................................................16
Figure 18 UBA-RC Operational Flowchart (Validation)...............................................17
Figure 19 UBA-RC Operational Flowchart (Validation Retry) .....................................18
Figure 20 UBA-RC Operational Flowchart (Stacking/Recycle Unit)............................19
Figure 21 UBA-RC Operational Flowchart (Stacking/Cash Box) ................................20
Figure 22 UBA-RC Operational Flowchart (Dispensing).............................................21
Figure 23 UBA-RC Operational Flowchart (Abnormal Banknote Detection)...............22
Figure 24 UBA-RC Operational Flowchart (Retrieving) ..............................................22
Figure 25 UBA-RC Banknote Acceptor Unit Outside Dimensions ..............................23
Figure 26 UBA-RC Banknote Acceptor Cash Box Outside Dimensions .....................24

P/N 960-100928R_Rev. A {EDP #192691} iii © 2010, Japan CashMachine Co, Limited
UBA-RC™ Series Integration Guide List of Figures

THIS PAGE INTENTIONALLY LEFT BLANK

P/N 960-100928R_Rev. A {EDP #192691} iv © 2010, Japan CashMachine Co, Limited


UBA-RC™ Series
Integration Guide
List of Tables
Page
LOT
Table 1 UBA-RC Model Number Specifications..........................................................2
Table 2 UBA-RC Type Specifications .........................................................................2
Table 3 UBA-RC Software Number Specifications .....................................................2
Table 4 UBA-RC Technical Specification....................................................................5
Table 5 UBA-RC Environmental Specification ............................................................6
Table 6 UBA-RC Electrical Specification.....................................................................6
Table 7 UBA-RC Structural Specification....................................................................6
Table 8 UBA Transport Unit DIP Switch Settings........................................................7
Table 9 Recycler Unit DIP Switch Settings .................................................................8
Table 10 Photo-Coupler Interface Connection Pin Assignments ..................................9
Table 11 RS232C Interface Connection Pin Assignments..........................................10
Table 12 Power Supply Interface Connection Pin Assignments .................................10
Table 13 Front Panel Bezel Interface Connection Pin Assignments...........................11
Table 14 UBA-RC Sensor Type Cleaning Methods ....................................................14
Table 15 UBA Unit LED Code Condition.....................................................................25
Table 16 Recycle Unit LED Color Type Error Code Conditions ..................................25
Table 17 Recycler Unit LED Code Conditions ............................................................26
Table 18 Recycler Unit LED Flashing Error Code Conditions.....................................26

P/N 960-100928R_Rev. A {EDP #192691} v © 2010, Japan CashMachine Co, Limited


UBA-RC™ Series Integration Guide List of Tables

THIS PAGE INTENTIONALLY LEFT BLANK

P/N 960-100928R_Rev. A {EDP #192691} vi © 2010, Japan CashMachine Co, Limited


UBA-RC™ Series
Banknote Recycler
Integration Guide
Revision A
1 GENERAL INFORMATION
Description
This section provides a general overview of the • Technical Contact Information.
UBA® Series BankNote Recycler (UBA-10/11-SH- In order to make operation of this device easier and
RC; UBA-RC) Unit Assembly pictured in Figure 1. make navigation within this manual simpler, the
This first section is designed to help you navigate following illustrations were used within the text:
through this guide with ease and provides the • Safety Instructions, which need to be observed in
following information: order to protect the operators and equipment, have
• UBA-RC™ Unit been written in bold text and have been given the
• Model Description following pictographs:
• Precautions • Special Notes, which effect the use of the Banknote
• Primary Features Acceptor, have been written in italic text and have
• Component Names been given the pictograph:
• Specifications • Steps, requiring the operator to perform specific
• Unit Dimensions actions are given sequential numbers (1., 2., 3., etc).
• International Compliance

UBA-RC Unit Assembly


SENTRY-2 BEZEL
ASSEMBLY (OPTION) UBA VALIDATION
ASSEMBLY
(NOT INCLUDED)

UBA-RC RECYCLER
ASSEMBLY
UBA-RC
FRAME UNIT

UBA-RC CASH BOX


ASSEMBLY

Figure 1 UBA-RC Unit Assembly

P/N 960-100928R_Rev. A {EDP #192691} 1 © 2010, Japan CashMachine Co, Limited


UBA-RC™ Series Banknote Recycler Integration Guide

Model Number Specifications Table 2 UBA-RC Type Specifications (Continued)


MODEL DESCRIPTIONS Type: 4 * * - 0 0 - * * * * * * * * * (-*)
No
Table 1 lists the Product Model Number No (1,2,3) (4,5) (6,7,8,9,10,11,12,13,14,15)
Descriptions. RC2 Recycler Unit Banknote Length Guide
Table 1 UBA-RC Model Number Specifications (14) 0 = None
1 = 120mm
4 = 140mm
5 = 147mm
2 = 127mm 6 = 158mm
Model: UBA - 1 * * - * SH2 * - RC 3 = 133mm
No Optional Cash Box Fastener
No (1) (2)(3) (4) (5) (6) (7) (15) 0 = None
1 = Thumb Twist Lock Fastener for the Cash Box
(1) Product Series Name *. Only Optional Bezel 1, Optional Bezel 2 and Optional Bezel A can be
adapted to the Unit when using the Bezel Option Extension.
CPU Board
(2) 0 = Flash ROM (8Mbit)
2 = Flash ROM (16Mbit) Software Descriptions
(3) Transport Unit Type
none = Standard
Table 3 lists the Software Number Descrip-
(4) Option Unit (Input Section) tions.
none = Standard
Table 3 UBA-RC Software Number Specifications
(5) Stacker Type
SH2 = Horizontal Down (82mm Specification)
Software: UBA-10(*)-(*)SH2(*)-RC * * * - 0 * * - V * .**
(6) Box Access No
None = Front Access (Standard) No (A) (B) (C) (D)
(7) Recycle Function
RC = Recyclable (A) Software Model Name
TYPE DESCRIPTIONS (B) Denomination (Country)*
Table 2 lists the Product Type Number (C) Interface Protocol Name
Descriptions. (D) Software Version
Table 2 UBA-RC Type Specifications *. The Country Code is indicated by three (3) Alphabetical Characters
following the JIS Standard.
Type: 4 * * - 0 0 - * * * * * * * * * (-*)
No
No (1,2,3) (4,5) (6,7,8,9,10,11,12,13,14,15)
Precautions
(1) Cash Box Capacity
4 = 400 notes

(2) Cash Box Type


0 = Standard

(3) Cash Box Handle


0 = Standard Type 1 Type 2 Type 3
Transport Section
(4) 0 = Standard (Earlier Type) Figure 2 Precautionary Symbols
1 = 3.3v Flash ROM CPU Board
The Figure 2 symbols are defined as follows:
(5) Transport Cover
0 = Standard (Blue) 1. (Type 1) Do not insert a torn, folded, or wet
Bezel (Option) Banknotes into the Unit, as this action may cause
0 = None
1 = Black/Green LED (UBA Standard Bezel 85) a Banknote jam inside the Unit.
(6) 2 = Blue/Blue LED (UBA Standard Bezel 85)
8 = Black/Green LED (UBA Euro Bezel 82) 2. (Type 2) Do not expose the Recycler Unit to
9 = Smoke Blue/Blue LED (UBA Euro Bezel 82)
A = Blue/Blue (2-Line) (UBA Standard Bezel 85)
water. The Unit contains several precision elec-
tronic devices which can be damaged if water or
Bezel Extension (Option)
(7) 0 = No any liquid of any kind is sprayed or spilled into
1 = Yes* the Unit.
(8) Optional Power Board
1 = Standard (Power Board Featured)
3. (Type 3) Do not install the Unit into a dusty
environment. Dust may affect and degrade the
Input/Output Signal Recycler’s performance.
(9) P = Photo-Coupler Isolation
R = RS232C
USER CAUTIONS
External Harness
(10) 0 = None Careful measures are taken in this product to ensure
1 = Standard
RC1 Recycler Unit Banknote Width Guide
its quality; however, the following cautions should
(11) 0 = None 3 = 72mm be read and understood by all users in order to con-
1 = 62mm 4 = 77mm
2 = 67mm firm safe operation.
RC2 Recycler Unit Banknote Width Guide Installation Cautions
(12) 0 = None
1 = 62mm
3 = 72mm
4 = 77mm The installation Cautions are defined as follows:
2 = 67mm
RC1 Recycler Unit Banknote Length Guide 1. Do not allow the Unit to endure or operate at a
0 = None 4 = 140mm high temperature, in high humidity and/or in a
(13) 1 = 120mm 5 = 147mm dusty environment.
2 = 127mm 6 = 158mm
3 = 133mm 2. Do not install the Unit into an area where exces-
sive vibration or shock are present.

P/N 960-100928R_Rev. A {EDP #192691} D2 2 © 2010, Japan CashMachine Co, Limited


UBA-RC™ Series Banknote Recycler Integration Guide

3. This equipment is not fully warranted for outdoor


use. Be sure that the Host Machine contains Caution: DO NOT use any Alcohol,
enough protection to avoid wet or dusty condi- solvents, scouring agents or Citrus
tions when installing it in both open-air and an based cleaners that can damage
indoor space.
the Plastic surface of the device
4. Avoid exposing the Unit to direct Sunlight and/or
Incandescent Lamp illumination having a when cleaning it.
Gradient Angle of 15 Degree or more, and an
illumination index of 3000 Lux or less. BANKNOTE FITNESS REQUIREMENTS
5. Insure that the Host Machine is designed for daily The following Banknote types may not validate
operational access such as maintenance and/or for correctly, or can cause a Banknote jam and/or dam-
clearing a Banknote jam.
age to the Unit’s Transport path. Banknotes exhibit-
6. When installing the equipment, connect the
Frame Housing to the Frame Ground of the Host ing the conditions listed below and illustrated in
Machine. Figure 3 should be avoided:
7. Because this equipment is a component product, • Torn
close the Host Machine’s door before using it. • Having excessive folds
8. Do not operate the UBA-RC Unit while the Cash • Dirty
Box and/or the Recycler Unit’s door is open.
Personal injury may occurs. • Wet
Mounting, Dismounting & Transportation • Having excessive wrinkles
Methods for Mounting, Dismounting & Transport- • Adhering foreign objects and/or oil.
ing the Unit are as follows:
1. Be sure to turn the Power OFF to the UBA® Unit
before mounting or removing the Recycler Unit
from its permanent location. Attaching or unplug- Damaged Banknotes
ging Connector Plugs from their Receptacles
while the Power is ON may damage the Unit.
2. When reassembling a Unit’s Section, ensure that
each part is replaced in its correct location. Wrinkled Banknotes
3. Be sure to carry the Unit by both hands when
transporting it. Holding the Unit by one hand may
cause personal injury if the Unit accidently
becomes disassembled and falls away from the Curled Banknotes
Frame housing.
4. Be careful not to use excessive outside pressure
on the Recycler Unit, or subject it to excessive
vibration during transportation.
5. Check that the UBA® Transport Section does not Folded or Partial Banknotes
drop off the Unit Frame while pulling the Recy- Figure 3 Unacceptable Banknotes
cler forward from the Frame.
Preventive Maintenance Primary Features
The Preventive Maintenance requirements are The UBA® Series UBA-RC contains the
defined as follows: following primary features:
1. Be sure to turn the Power OFF before beginning a • Features a high capacity, compact size, Recycling
maintenance procedure. The equipment produces Unit available for two (2) different denominations
improper operating signals while in maintenance • The Friction Roller System eases operation and
mode that may cause personal injury. maintenance of the Recycler Unit
2. When closing the Recycler Unit, ensure all ser- • The automatic Centering Mechanism allows the
vice door locks click into place. Unit to read Banknotes ranging from 62mm to
3. If the UBA® Validator Section is dirty due to dust, 82mm in width: a maximum of 158mm in length,
foreign objects or other such debris adhering to it, and it will center Banknotes inserted obliquely to
the Banknote acceptance rate will degrade. help improve its acceptance rate
Clean the Transport Unit once a month to keep its • A Security Recycler Box containing a Key Lock is
performance stable. composed of durable, impact-resistant Plastic
4. Use a soft, lint-free cloth, cotton swab or a com- construction to assure safe and secure cash handling
pressed air spray to clean dust and debris from the
Banknote path and inside areas of the Recycler. • The JCM patented Anti-Pullback Mechanism
provides powerful protection against Banknote
5. Do not redesign or disassemble the Recycler Unit.
Unauthorized use by inadequately trained stringing operations.
personnel, or use outside the original manufac-
turer’s intent for operation voids the warranty.

P/N 960-100928R_Rev. A {EDP #192691} D2 3 © 2010, Japan CashMachine Co, Limited


UBA-RC™ Series Banknote Recycler Integration Guide

Component Names
Figure 4 illustrates the UBA-RC™ Component Names and Locations.

A N
Front Side M

B
O

Recycler Unit
L
Q

D
E
F
G
Rear Side
H
C
I S

K
T
R

C: Front Panel Access Door


1 2 3
4

H
5

A.UBA Transport Unit (User Supplied) H.Recycler Unit Lock


B.Upper Guide Access Lever I. Recycler Unit
C.Front Panel Access Door J.Cash Box Lock Holes (User supplied Options)
1. USB Type-B Male Receptacle (for performing K.Cash Box
Software downloads and adjustments)
L.Bezel Accessory (One of 3 Options available)
2. 8 Position DIP Switch Block
3. UBA Transport Unit LEDs (Green & Red) M.Bezel Spacer (Option)
4. Front Bezel Receptacle (for the Bezel Assembly N.Centering Guide Release Port
Plug) O.Interface Connector (Connects to the Host Machine)
5. Transport Unit Release Lever P.Housing Frame
D.RC Unit DIP Switch Block Q.RC1 Assembly Space
E.RC Unit LEDs (Green, Red & Yellow) R.RC2 Assembly Space
F.Recycler Unit Release Pushbutton Switches S.Banknote Width Guide
G.Restore Pushbutton Switch (for restoring T.Banknote Length Guide
Banknotes from the Recycler Unit to the Cash Box)

Figure 4 UBA-RC Component Names

P/N 960-100928R_Rev. A {EDP #192691} D2 4 © 2010, Japan CashMachine Co, Limited


UBA-RC™ Series Banknote Recycler Integration Guide

2 SPECIFICATIONS
TECHNICAL SPECIFICATIONS
Table 4 UBA-RC Technical Specification
98% or greater
Note: The following Banknote types are excluded:
a) Banknotes with excess or poor magnetism or unclear graphics
Acceptance Rate: b) Double (dual) Banknotes
c) Worn, dirty, wet, stained, torn or excessively wrinkled Banknotes
d) Banknotes having folded corners or edges
e) Banknotes having the wrong cut dimensions or a printing displacement.
Acceptable Denomination: Refer to the specific Country’s “Software Specification”
Recycler Unit
• Length: 120-158mm (4.72-6.22 in.)
• Width: 62-82mm (2.44-3.22 in.)
Banknote Types Accepted*:
Cash Box
• Length: 120-170mm (4.72-6.69 in.)
• Width: 62-82mm (2.44-3.22 in.)
Standard Specification
a) Interleaved Barcode Read: 2 of 5
b) Narrow Bar Width: 0.5mm-0.6mm (0.019-0.023 in.)
Barcode Coupon†: c) Wide Bar to Narrow Bar ratio = 3:1
d) Characters: 18 Characters
e) Print Position: Middle (Divides a Coupon equally to the left, right, top and
bottom of the Coupon’s center line)
f) Print Width: Wider than 10mm (0.39 in.)
Banknote: Refer to the specific Country’s “Software Specification”
Insertion Direction:
Barcode Coupon: Two-way (with Barcode Surface Facing Upward)
From Banknote insertion to Vend signal output:
• Approximately 3 seconds
From Banknote insertion to stacking operation completion:
• Approximately 7 seconds (to Recycler Unit)
Processing Speed‡: • Approximately 8 seconds (to Cash Box)
From dispense beginning, to dispensing operation completion:
• Approximately 4 seconds
From retrieve beginning to retrieving operation completion:
• Approximately 7 seconds
Escrow: 1 Note
Transport Unit: Two LEDs (Red/Green)
Diagnostic Indicators: Recycler Unit: Two, Tri-Color LEDs (Red/Green/Yellow)
Centering Home Position Indicator LED (Red)
Cash Box: Steel, Secure Type (WBA-SH2 Cash Box Design)**
Cash Box Capacity: Approximately 400 notes (Street Grade Notes)
Recycler Unit: Key Lockable, 2 Denomination Integral Recycler (Friction Roller System)
Recycler Unit Capacity: 100 Notes (New Banknotes Only)
Stores Banknotes from the Acceptor (Recommended)
Recycle Unit Storage Method:
Stores Banknotes directly
Interfaces: Photo-Coupler Isolation, TTL, RS232C
*. Banknote sizes are limited by the Guides inserted.
†. Refer to specific “Barcode Coupon Specification” for more details.
‡. Excludes the Host Communication time lag (Power Supply: +12V DC, Temperature: 25º C ±5º C).
**.Lock(s) and Key(s) provided by User (2 Key Hole Caps are fitted in place to cover existing holes when shipped).

P/N 960-100928R_Rev. A {EDP #192691} 5 © 2010, Japan CashMachine Co, Limited


UBA-RC™ Series Banknote Recycler Integration Guide

ENVIRONMENTAL SPECIFICATIONS
Table 5 UBA-RC Environmental Specification

Operating Temperature: 5ºC to +50ºC (41ºF to 122ºF)


Storage Temperature: -20ºC to +60ºC (-4ºF to 140ºF)
Relative Operating Humidity: 30% to 85% RH (non-condensed)
Relative Storage Humidity: 30% to 85% RH (non-condensed)
Visible Light Sensitivity: Avoid contact with direct Sunlight
Installation: Indoors Only

Hydrothermal Condition Table


[RH%]
35°C/85%

Allowable Operating
50°C/40%
Temperature and
Humidity Range

[°C]

ELECTRICAL SPECIFICATIONS
Table 6 UBA-RC Electrical Specification

Supply Voltage: 24V DC (±5%) (Greater than 3.5A Recommended)


Standby: 200mA
Current Consumption: Operation: 1.5A
Peak: 2.5A
STRUCTURAL SPECIFICATIONS
Table 7 UBA-RC Structural Specification

Weight Empty: Approximately 10kg (22.05lbs)


Mounting: Horizontal
Refer to “UBA-RC Banknote Acceptor Unit Outside Dimensions” on
Outside Dimensions:
page 23 of this Guide

3 INSTALLATION
This section provides installation and operating Screws from both outsides of the Frame
instructions for the Universal Banknote Acceptor (See Figure 5).
UBA® Series Recycler Unit. The information
within contains the following features:
• Installation Process
• DIP Switch Configurations
• Jumper Configurations
• Connector Pin Assignments
• Preventive Maintenance
• Clearing Banknote Jam
• Cleaning
• Interface Schematic
• Operational Flowchart.
Installation Process
Holes are provided in each Frame Unit to mount the
UBA-RC™ during installation. Select and perform
the following steps to install the UBA-RC™ Unit:
1. When a side mounting configuration is preferred,
bolt the left or right side of the UBA-RC™ Frame
into its intended location using each six (6) M4
Figure 5 M4 Screws Locations (Right/Left)

P/N 960-100928R_Rev. A {EDP #192691} 6 © 2010, Japan CashMachine Co, Limited


UBA-RC™ Series Banknote Recycler Integration Guide

2. When a rear mounting configuration is preferred, Cable Interconnection


bolt the inside back of the UBA-RC™ Frame into
its intended location using four (4) M4 Phillips Figure 7 illustrates the Cable interconnection
Head Screws (See Figure 6 a1 through a4). requirements between the UBA-RC™ and a Host
3. When a bottom mounting configuration is pre- Machine.
ferred, bolt the inside or outside of the UBA-RC
Frame into its intended location using four (4) M4 b
Phillips Head Screws. To bolt the Frame down
from the inside, place the screws in the four un-
threaded holes located in the inside of the Frame c
(See Figure 6 b1 through b4); or bolt the Frame
down from the outside using the four threaded
Stud Insert holes from the outside of the Frame
(See Figure 6 c1 through c4).

a) UBA-RC Unit
b) Interface Connector
c) Interconnecting Harness
d) Host Machine (Game Machine, Kiosk, etc.)
a1
Figure 7 Cable Interconnection
a3 a4
b1 DIP Switch Configurations
a2 This portion provides the denomination DIP Switch
Block settings for the UBA-RC™ Unit.
b3 b4 Table 8 UBA Transport Unit DIP Switch Settings
UBA Transport Unit DIP Switches

b2

Switch Switch ON Switch OFF


No.
1 VEND 1 INHIBIT VEND 1 ACCEPT
2 VEND 2 INHIBIT VEND 2 ACCEPT
c1 3 VEND 3 INHIBIT VEND 3 ACCEPT
4 VEND 4 INHIBIT VEND 4 ACCEPT
c4 5 VEND 5 INHIBIT VEND 5 ACCEPT
c2
6 VEND 6 INHIBIT VEND 6 ACCEPT
7 VEND 7 INHIBIT VEND 7 ACCEPT
c3
8 OFF OFF
Figure 6 M4 Screws Locations (Rear & Bottom)
NOTE: Choose two (2) of the five (5)
installation configuration sides shown, and
bolt the correct number of M4 Screws firmly
in place. When bolting the Screws from the
outside, the maximum length of each M4
Screw should be less than 7mm long.

P/N 960-100928R_Rev. A {EDP #192691} 7 © 2010, Japan CashMachine Co, Limited


UBA-RC™ Series Banknote Recycler Integration Guide

Table 9 Recycler Unit DIP Switch Settings


Recycler Unit DIP Switches

Switch Switch ON Switch OFF


No.
1 Reserved Reserved
2 Reserved Reserved
3 Reserved Reserved
4 Reserved Reserved
5 Reserved Reserved
6 Reserved Reserved
7 Reserved Reserved
8 Reserved Reserved

Jumper Configurations
The UBA CPU Board contains three 3.3 Volt DC
(3) Jumper Plugs that are adjacent to one another.
Photo-coupler Isolation and/or RS232C Protocol
selection is configured by these Jumpers. All three
(3) Jumpers must be configured to represent the
same setting when changed (See Figure 8).

3 Jumpers

Photo-Coupler
Isolation

RS232C
=

Shorted

Figure 8 3.3V DC UBA CPU Board Bottom View

P/N 960-100928R_Rev. A {EDP #192691} 8 © 2010, Japan CashMachine Co, Limited


UBA-RC™ Series Banknote Recycler Integration Guide

4 CONNECTOR PIN ASSIGNMENTS


Table 10 lists the Photo-Coupler Interface Connector Pin Assignments.
Table 10 Photo-Coupler Interface Connection Pin Assignments

Socket (Transport Unit Side): DRA-20PC-FO (JAE)


Contact (Transport Unit Side): D02-22-26P-10000 (JAE)
Socket (Frame Side): DRA-20SC-FO (JAE)
Contact (Frame Side): D02-22-26S-10000 (JAE)/D02-22-22S-10000 (JAE) (Terminal# 3, 13)
Recommended Wires: Slit Wire UL1061 AWG #26

Pin No. Signal Name I/O* Function

1 -- - Reserved (For the UBA Side)


2 -- - Reserved (For the UBA Side)
3 M.RES IN Acceptor Hard Reset Signal Line
4 TXD OUT Output Signal Line from Acceptor to Host
5 -- - Reserved (For the UBA Side)
6 RXD IN Input Signal Line from Host to Acceptor
7 GND (I/F) - Interface Power Supply
8 -- - Reserved (For the UBA Side)
9 -- - Reserved (For the UBA Side)
10 NC - No Connection
11 -- - Reserved (For the UBA Side)
12 NC - No Connection
13 NC - No Connection
14 LED (Power) - LED Indicator Power Supply Line (Anode)
15 -- - Reserved (For the UBA Side)
16 NC - No Connection
17 NC - No Connection
18 LED - LED Indicator Control Line (Cathode)
19 NC - No Connection
20 NC - No Connection
*. I/O (Input/Output) terminal as viewed from outside the back of the Banknote Acceptor.

P/N 960-100928R_Rev. A {EDP #192691} D2 9 © 2010, Japan CashMachine Co, Limited


UBA-RC™ Series Banknote Recycler Integration Guide

CONNECTOR PIN ASSIGNMENTS (CONTINUED 1)


Table 11 lists the RS232C Interface Connector Pin Assignments.
Table 11 RS232C Interface Connection Pin Assignments

Socket (Transport Unit Side): DRA-20PC-FO (JAE)


Contact (Transport Unit Side): D02-22-26P-10000 (JAE)
Socket (Frame Side): DRA-20SC-FO (JAE)
Contact (Frame Side): D02-22-26S-10000 (JAE)/D02-22-22S-10000 (JAE) (Terminal# 3, 13)
Recommended Wires: Slit Wire UL1061 AWG #26

Pin No. Signal Name I/O* Function

1 -- - Reserved (For the UBA Side)


2 -- - Reserved (For the UBA Side)
3 M.RES IN Acceptor Hard Reset Signal Line
4 TXD OUT Output Signal Line from Acceptor to Host
5 -- - Reserved (For the UBA Side)
6 RXD IN Input Signal Line from Host to Acceptor
7 NC - No Connection
8 -- - Reserved (For the UBA Side)
9 -- - Reserved (For the UBA Side)
10 NC - No Connection
11 -- - Reserved (For the UBA Side)
12 NC - No Connection
13 GND (I/F) - Interface Power Supply
14 LED (Power) - LED Indicator Power Supply Line (Anode)
15 -- - Reserved (For the UBA Side)
16 NC - No Connection
17 NC - No Connection
18 LED - LED Indicator Control Line (Cathode)
19 NC - No Connection
20 NC - No Connection
*. I/O (Input/Output) terminal as viewed from outside the back of the Banknote Acceptor.

Table 12 lists the UBA-RC Power Supply Pin Assignments.


Table 12 Power Supply Interface Connection Pin Assignments

Header Type: 53426-0410 (MOLEX)


Contact Type: 50351-8100 (MOLEX)
Housing: 51103-0400 (MOLEX)
Recommended Wires: Slit Wire UL1007 AWG #22-24

Pin No. Signal Name I/O* Function

1 +24V Power - +24V DC Power Supply


2 +24V Power - +24V DC Power Supply
3 GND (Power) - 0V DC Power
4 GND (Power) - 0V DC Power
*. I/O (Input/Output) terminal as viewed from outside the back of the Banknote Acceptor.

P/N 960-100928R_Rev. A {EDP #192691} D2 10 © 2010, Japan CashMachine Co, Limited


UBA-RC™ Series Banknote Recycler Integration Guide

CONNECTOR PIN ASSIGNMENTS (CONTINUED 2)


Table 13 lists the Front Panel Bezel Interface Connector Pin Assignments.
Table 13 Front Panel Bezel Interface Connection Pin Assignments

Header Type: RF-H08(07)2SD-1110 (JST)


Contact Type: RF-SC2210 (JST)
Housing: RF-08 (JST)
Recommended Wires: Slit Wire UL1007 AWG #24-26

Pin No. Signal Name I/O* Function

1 NC - No Connection
2 NC - No Connection
3 NC - No Connection
4 NC - No Connection
5 +13V (Power) - +13V DC Power (from UBA)
6 GND (Power) - 0V DC Power (from UBA)
7 LED Power - LED Drive Line (anode)
8 LED- - LED Drive Line (cathode)
*. I/O (Input/Output) terminal as viewed from outside the back of the Banknote Acceptor.

5 PREVENTIVE MAINTENANCE
Restoring Banknotes 4. Close the Recycler Unit’s Door and lock it using
the Key provided.
To restore Banknotes into the Recycle Unit, per- 5. Once the Banknote restoration is complete, the
form the following one (1) of two (2) procedures. data containing the number of restored Banknotes
RESTORING BANKNOTES USING THE UBA is sent from the Host Machine to the UBA-RC™.
TRANSPORT UNIT NOTE: When restoring Banknotes directly,
1. Insert Banknotes note-by-note in a single fashion make sure the denominations inserted are
into the UBA® Transport Unit Insertion Slot correct. Before restoring, flip-over and Fan-
(See Figure 9 a). Flip the Banknotes; make their edges
RESTORING BANKNOTES DIRECTLY INTO THE smooth and then set the Banknotes to the
RECYCLER UNIT back of the open space.
1. Turn the UBA-RC™ Power Supply OFF. Retrieving Banknotes
2. Unlock and open the Recycler Unit’s Door using To retrieve Banknotes from the Recycler Unit, per-
the Key provided.
form the following one (1) of two (2) procedures.
3. Smooth and restore the Banknotes edges being
fed into the Recycler Unit (See Figure 9 b). SENDING RETRIEVED BANKNOTES TO THE
CASH BOX
1. Press the “Retrieve” Switch on the Recycler Unit.
2. The Banknotes in the RC1 Space and RC2 Space
are retrieved note-by-note into the Cash Box.
3. Remove the Cash Box from the UBA-RC™ Unit
a and retrieve the Banknotes.
Retrieving Banknotes from the Cash Box
1. Using the appropriate user supplied Key to
unlock the Cash Box.
b 2. Open the Cash Box Door and retrieve the
Banknotes from within (See Figure 10 a).
RETRIEVING BANKNOTES DIRECTLY
1. Send a “Retrieving” Status Command to the
UBA-RC™ Unit from the Host Machine.
Figure 9 Banknote Restoration Methods 2. Turn the UBA-RC™ Power Supply OFF.

P/N 960-100928R_Rev. A {EDP #192691} D2 11 © 2010, Japan CashMachine Co, Limited


UBA-RC™ Series Banknote Recycler Integration Guide

3. Unlock and open the Recycle Unit Door using the remove the jammed Banknote from inside either
Key supplied. the RC1 Space or the RC2 Space of the Recycler
4. Retrieve the Banknotes from the RC1 Space and/ Unit Assembly (See Figure 12 c).
or the RC2 Space by hand (See Figure 10 b). 6. If the Banknote jam location is not evident, pull
5. Close the Recycler Unit Door and re-lock it using the Cash Box out of the Frame (See Figure 11 e)
the Key supplied. and remove the jammed Banknote from inside the
Frame Unit (See Figure 12 d).
7. Open the Cash Box Door using the appropriate
User Supplied Key (See Figure 11 e), and remove
the jammed Banknote from inside the Cash Box
(See Figure 12 e).

b
b
c
a Key
Locks
d

Figure 10 Retrieving Recycler Banknotes


Dispense Settings e
Dispensing Banknotes from the RC1 Space and/or
RC2 Space of the Recycler Unit is possible.
Figure 11 Clearing a Banknote JAM 1
Banknote denomination dispensing is pre-decided
for each RC Space setting.
When changing the dispensable Banknote denomi-
nations, replace the Recycler Unit with another a
Unit containing the different denomination settings.
NOTE: When setting the Recycler’s
denomination values; check the Banknote
sizes against the Recycler Unit’s size
limitation settings (e.g., 62-82mm width,
120-158mm length), and ensure that the b
correct Banknote Guide is replaced for
proper width and length. This operation
should be performed after appropriate
Operator training has been completed. c d
Clearing a Banknote JAM e
When a Banknote is jammed in the UBA-RC™,
proceed as follows to clear it:
Figure 12 Clearing a Banknote JAM 2
1. Open the Upper Guide of the UBA’s Transport
Unit (See Figure 11 a). CLEANING PROCEDURE
2. Remove the jammed Banknote from the Trans- It is important to keep the Banknote Path, Rollers,
port Path (See Figure 12 a).
3. If the Banknote jam location is not evident, press
and Belts clean. Adhering foreign objects or dirt on
the Recycler Unit’s “Release” Push Button the Validation Sensors may cause acceptance errors
(See Figure 11 b) and pull the Recycler Unit out or acceptance rate degradation. Use a soft lint-free
of the Frame Assembly (See Figure 11 c). cloth or a Cotton Swab to wipe dirt and stains from
4. Check the inside the Frame Unit and remove any the surfaces of the Optical Sensors, Rollers and
jammed Banknotes found there (See Figure 12 b). Belts. If necessary, blow the foreign objects or the
5. If the jammed Banknote is not evident, unlock dirt away using Compressed Air. The Sensor
and open the Recycler Unit Door using the appro- Lenses are transparent, and made of a Polymer
priate Key supplied (See Figure 11 d), and then
material; Handle them with care. Repeat the clean-

P/N 960-100928R_Rev. A {EDP #192691} D2 12 © 2010, Japan CashMachine Co, Limited


UBA-RC™ Series Banknote Recycler Integration Guide

ing process as needed until the Transport Path is


free of contaminants.
Sensor Cleaning Procedure
Perform the following steps to clean the UBA® and
UBA-RC™ Unit’s Sensors:
1. Turn the UBA-RC™ Unit and the Host
Machine’s Power OFF.
2. Open the UBA® Unit’s Transport’s Upper Guide.
3. Pull the Recycler Unit out of the Frame Housing.
4. Clean the Sensors, Lenses and Rollers within the
UBA® Transport Unit, the Recycler Unit and
those located on the Cash Box itself.

Caution: Do not use Alcohol, thinner or


Citrus based products for cleaning any
surfaces. The lenses become clouded
by chemical effect that may cause
acceptance errors.

NOTE: When closing the UBA’s Transport


Unit or the Recycler Unit’s Upper Guides,
ensure they firmly click into place when
closed. Also, when re-assembling the UBA-
RC™ Unit, ensure that it reseats correctly
into place when reassembly is complete.

P/N 960-100928R_Rev. A {EDP #192691} D2 13 © 2010, Japan CashMachine Co, Limited


UBA-RC™ Series Banknote Recycler Integration Guide

6 UBA-RC SENSOR LOCATIONS


Figure 13 illustrates the various UBA-RC Sensor cleaning locations, and Table 14 lists the UBA-RC
Sensor Type and related Cleaning Methods respectively.

c d
c b e
f
e a g

f h
i
j

NOTE: Remove the Recycler Box and k


clean the enclosed Blue Rectangular
enclosed location using
Compressed Air.

s l
m
p n
o

r q

Figure 13 UBA-RC Sensor Cleaning Locations


Table 14 UBA-RC Sensor Type Cleaning Methods
Sym. Sensor Type Sym. Sensor Type Cleaning Method
a RC2 End Sensor LED k RC1 Full Sensor LED
b RC1 End Sensor LED l Lifter Home Position Sensor LED
c Recycle Unit Sensor m Lifter Home Position Sensor PT
d RC1 Full Sensor PT n RC2 End Sensor PT
Wipe clean using
Double Notes Detection Sensor a lint free cloth or
e o RC2 Full Sensor PT
LED blow clean using
f Double Notes Detection Sensor PT p Transport Sensor 2 Prism Compressed Air
g RC1 End Sensor PT q Lifter Home Position Sensor Prism
h Transport Sensor 1 r Recycle Unit Sensor Prism
i RC1 Full Sensor LED s Transport Sensor 1 Prism
j Transport Sensor 2

P/N 960-100928R_Rev. A {EDP #192691} 14 © 2010, Japan CashMachine Co, Limited


UBA-RC™ Series Banknote Recycler Integration Guide

7 STANDARD INTERFACE CIRCUIT SCHEMATICS


Figure 14 illustrates the UBA-RC Photo-Coupler Circuit Interface Schematic Diagram.

Controller Side Validator Side

Figure 14 UBA-RC Photo-Coupler Circuit Interface Schematic Diagram


Figure 15 illustrates the UBA-RC RS232C Protocol Circuit Interface Schematic Diagram.

Controller Side Validator Side

Figure 15 UBA-RC RS232C Circuit Interface Schematic Diagram


Figure 16 illustrates the UBA-RC Bezel Circuit Interface Schematic Diagram.

Bezel Side Validator Side

Figure 16 UBA-RC Bezel Circuit Interface Schematic Diagram

P/N 960-100928R_Rev. A {EDP #192691} 15 © 2010, Japan CashMachine Co, Limited


UBA-RC™ Series Banknote Recycler Integration Guide

8 OPERATIONAL FLOWCHARTS
Figure 17 depicts part one of typical UBA-RC Banknote acceptance flow process (Initialize).

Apply Power to the Unit.

a) Initializing

A) Return from “h” or “d” in this Flow


b) Stand-by

c) Inhibit Acceptance?
d) External LED distinguish

e) External LED lights

f) Inserted the Banknote?


B1) To “Validation” Flow on page 17 of this Guide

g) Required dispensing the Banknote?


B2) To “Dispensing” Flow on page 21 of this Guide

h) Required collecting the Banknote?


B3) To “Retrieving” Flow on page 22 of this Guide

A) Return to “A” in this Flow

Figure 17 UBA-RC Operational Flowchart (Initialize)

P/N 960-100928R_Rev. A {EDP #192691} 16 © 2010, Japan CashMachine Co, Limited


UBA-RC™ Series Banknote Recycler Integration Guide

OPERATION FLOWCHARTS (CONTINUED 1)


Figure 18 depicts part two of typical UBA-RC Banknote acceptance flow process (Validation).

B1) Return from “Initialization” Flow on page 16 of


this Guide
D2) Return from “Validation Retry” Flow on page 18
of this Guide
a) Intake the Banknote

b) Centering the Banknote

c) Transporting the Banknote

d) Sampling the Banknote Data

e) Stop Transportation

f) Is the Banknote authentic?


D1) To “Validation Retry” Flow on page 18 of this
Guide

g) Acceptance Inhibit?

h) Sending VEND signal

i) Is the Banknote storing the Recycle Unit?


C1) To “Stacking/Recycle Unit” Flow on page 19 of
this Guide

j) Is the Banknote storing the Cash Box?


C2) To “Stacking/Cash Box” Flow on page 20 of this
Guide

k) Return the Banknote

Figure 18 UBA-RC Operational Flowchart (Validation)

P/N 960-100928R_Rev. A {EDP #192691} 17 © 2010, Japan CashMachine Co, Limited


UBA-RC™ Series Banknote Recycler Integration Guide

OPERATION FLOWCHARTS (CONTINUED 2)


Figure 19 depicts part three of typical UBA-RC Banknote acceptance flow process (Validation Retry).

D1) Return from “Validation” Flowchart on page 17


of this Guide

a) Was Validation retried twice? (*1)


b) Return the Banknote

c) Transporting the Banknote to return to the


“Validation” Flow on page 17 of this Guide

D2) Return to “Validation” Flow on page 17 of this


Guide
*1). When the first validation failed, the Banknote is returned to the beginning of the validation process and is re-validate a
second time.

Figure 19 UBA-RC Operational Flowchart (Validation Retry)

P/N 960-100928R_Rev. A {EDP #192691} 18 © 2010, Japan CashMachine Co, Limited


UBA-RC™ Series Banknote Recycler Integration Guide

OPERATION FLOWCHARTS (CONTINUED 3)


Figure 20 depicts part four of typical UBA-RC Banknote acceptance flow process (Stacking in Recycler
Unit).

C1) Return from “Validation” Flow on page 17 of this


Guide

a) Transporting the Banknote to the Recycle Unit

b) Is the Banknote transporting?


c) Retry transportation three time?

d) Rotating the PB Unit

e) Is abnormal error detected on the PB Unit?


f) Stop performance, and send abnormal signal (*2)

g) Sending Acceptance VEND signal

h) Stacking the Banknote

i) Is the Recycle Unit full?


j) Sending FULL signal (*3)

A) Return to the “Initialize” Flow on page 16 of this


Guide
*2). When an abnormal signal is received, re-supply Power to the UBA-RC after resolving the problem, or send a RESET
Command from the Host Machine.
*3). When either the RC1 or RC2 Space inside the Recycler Unit is full, the recyclable Banknotes are stacked into the Cash
Box until the “Full” detection is cleared. The UBA-RC responds via Status Request from the Host Machine while it is
performing when either the RC1 or RC2 Space is full.

Figure 20 UBA-RC Operational Flowchart (Stacking/Recycle Unit)

P/N 960-100928R_Rev. A {EDP #192691} 19 © 2010, Japan CashMachine Co, Limited


UBA-RC™ Series Banknote Recycler Integration Guide

OPERATION FLOWCHARTS (CONTINUED 4)


Figure 21 depicts part five of typical UBA-RC Banknote acceptance flow process (Stacking in Cash Box).

C2) Return from “Validation” Flow on page 16 of this


Guide

a) Sending the Banknote to the Recycle Unit

b) Is the Banknote sending to the Cash Box?


c) Retry transportation three time?

d) Rotating the PB Unit

e) Is abnormal error detected on the PB Unit?


f) Stop performance, and sending abnormal signal
(*2)

g) Sending Acceptance VEND signal

h) Stacking the Banknote

i) Is the Cash Box full?


j) Sending FULL signal (*4)

k) Did the Banknote exhibit an abnormal condition


during a dispensing function?
B2) To “Dispensing” Flow on page 21 of this Guide

j) Were the required number of Banknotes counted


during the collection function?
B3) To “Retrieving” Flow on page 22 of this Guide

A) Return to the “Initialize” Flow on page 16 of this


Guide
*4). When a “Cash Box Full” Signal is received, retrieve the Banknotes from the Cash Box and re-seat the Cash Box back to
the Unit. The UBA-RC will automatically perform its re-initialization movement operation.

Figure 21 UBA-RC Operational Flowchart (Stacking/Cash Box)

P/N 960-100928R_Rev. A {EDP #192691} 20 © 2010, Japan CashMachine Co, Limited


UBA-RC™ Series Banknote Recycler Integration Guide

OPERATION FLOWCHARTS (CONTINUED 5)


Figure 22 depicts part six of typical UBA-RC Banknote acceptance flow process (Dispensing).

C2) Return from “Initialize” Flow on page 16 of this


Guide

a) Transporting the Banknote

b) Collecting the Banknote data

c) Is the Banknote abnormal condition?


E) To “Banknote Abnormal Detection” Flow on
page 22 of this Guide

d) Is the Banknote transporting to the Exit Slot?


e) Retry transportation ten times?

f) Stop performance, and send DISPENSE signal

h) Is the Banknote removed?

g) Sending abnormal signal (*5)

i) Sending VEND signal

j) Is the required counts of the Banknote dispensed?

A) Return to the “Initialize” Flow on page 16 of this


Guide
*5). The specific Banknote position may be treated as Abnormal, and an “Abnormal Condition Error” state will occur instead of
the normal dispensing “VEND Signal” being sent.

Figure 22 UBA-RC Operational Flowchart (Dispensing)

P/N 960-100928R_Rev. A {EDP #192691} 21 © 2010, Japan CashMachine Co, Limited


UBA-RC™ Series Banknote Recycler Integration Guide

OPERATION FLOWCHARTS (CONTINUED 6)


Figure 23 depicts part seven of typical UBA-RC Banknote acceptance flow process (Abnormal Banknote
Detection).

E) Return from “Dispensing” Flowchart on page 21


of this Guide

a) Is the Banknote abnormal condition? (Try twice)


(*6)

b) Sending abnormal signal

c) Is the Banknote dispensing from the Recycle


Unit?

d) Stop transportation

C2) Return to “Stacking/Cash Box” Flow on page 20


of this Guide
*6). The specific Banknote position, or an abnormal Banknote may be treated as an “Abnormal Error” occurrence condition.

Figure 23 UBA-RC Operational Flowchart (Abnormal Banknote Detection)

Figure 24 depicts part eight of typical UBA-RC Banknote acceptance flow process.

B3) Return from “Initialize” Flowchart on page 16 of


this Guide

a) Transporting the Banknote

b) Is the Banknote dispensing from the Recycle


Unit?

c) Stop transportation

C2) Return to “Stacking/Cash Box” Flow on page 20


of this Guide

Figure 24 UBA-RC Operational Flowchart (Retrieving)

P/N 960-100928R_Rev. A {EDP #192691} 22 © 2010, Japan CashMachine Co, Limited


UBA-RC™ Series Banknote Recycler Integration Guide

9 VARIOUS UNIT DIMENSIONS


UBA-RC ENTIRE UNIT OUTSIDE DIMENSIONS
Figure 25 illustrates the UBA-RC Unit’s entire outside dimensions.

NOTE: All Dimension are in Millimeters


Figure 25 UBA-RC Banknote Acceptor Unit Outside Dimensions
Figure 26 illustrates the UBA-RC Cash Box outside dimensions.

NOTE: All Dimension


are in Millimeters

Figure 26 UBA-RC Banknote Acceptor Cash Box Outside Dimensions

P/N 960-100928R_Rev. A {EDP #192691} 23 © 2010, Japan CashMachine Co, Limited


UBA-RC™ Series Banknote Recycler Integration Guide

10 LED DIAGNOSTIC CODES


This section provides Troubleshooting instructions This product allows the Operator to perform fault
for the UBA® Series BankNote Recycler (UBA-10/ diagnosis by checking various fault Table listings
11-SH-RC) Unit. This following information is against the symptom, and survey the cause(s) of
contained in this section: any failure occurrences during the process.
• Introduction After determining the cause of the failure, execute a
• Troubleshooting Overview
Performance Test, perform a Sensor re-adjustment
• Fault Table Listings
• LED Indication Conditions.
and then repair the Unit by replacing any appropri-
ate parts deemed necessary.
Introduction
Most Banknote Recycler failures are due to minor MALFUNCTION LED ERROR CODES
causes. Before replacing any parts, make sure that The UBA-RC™ Assembly contains a UBA® Trans-
all Assembly and Circuit Board Connectors are port Unit and the Recycler Unit containing External
properly fitted and the Harness is properly con- LEDs to indicate various Error Codes when spe-
nected. cific errors occur (e.g., a Banknote Jam inside the
Poor performance by the Recycler is often caused Unit.) The Green and Red LEDs of the UBA®
when dust or foreign objects adheres to the Sensors Transport Unit, and the two (2) Multi-Color LEDs
or the Transport Belts. Clean the Banknote Inser- of the Recycler Unit, indicate Error, Status and
tion Section first, then observe the operating state Communication error conditions by their flash and
of the Recycler in detail when re-initializing Power. extinguish lighting sequences.
This observation is important in locating any failure LED INDICATION CONDITIONS
causes and the possible fault location.
Table 15 lists the Green and Red LED Status/Error
Perform all repairs by referring to Calibration and
Code indications for a UBA® Transport Unit por-
Testing in Section 6 and in Disassembly/Reassem-
tion of the UBA-RC™ Housing Assembly.
bly in Section 4 of the UBA-RC Service Manual.
Table 16 lists the Red , Green or Yellow LED
TROUBLESHOOTING OVERVIEW Recycle Unit Color Type Error Code Conditions.
Table 15 UBA Unit LED Code Condition

Green LED Red LED Error Causes


Communication Error between the UBA Transport Unit and the Recycler
Flashes 2 times Unit.
Flashes 3 times Abnormal movement occurred in the Recycler Unit.
Flashes 4 times The Recycler Unit is empty.
Dispensed double banknotes, or detected an Abnormal Sensor
Flashes 5 times Condition.
Extinguished (Out) Flashes 6 times Recycler Unit Flash ROM is malfunctioning.
Flashes 7 times The Recycler Unit is not properly seated.
Banknote Jam occurred when dispensing a Banknote from the Recycler
Flashes 8 times Unit.
Flashes 9 times Recycler Unit Software download failure.
Flashes 14 times Abnormal movement occurred in the UBA Transport Unit
Synchronized Flashing Sets of both Red
Downloading of Recycler Unit Software.
and Green LEDs

Table 16 Recycle Unit LED Color Type Error Code Conditions

Color Error Causes


Red Error occurred before sending a Vend/Pay Valid Signal.
Yellow Error occurred after sending a Vend/Pay Valid Signal.
Green Error occurred except during a storing/dispensing condition.

P/N 960-100928R_Rev. A {EDP #192691} 24 © 2010, Japan CashMachine Co, Limited


UBA-RC™ Series Banknote Recycler Integration Guide

Table 17 and Table 18 lists the two (2) tri-color LED Status/Error Code indications for the Recycler Unit
Assembly.
Table 17 Recycler Unit LED Code Conditions

Left LED Right LED Causes


While storing Banknotes, or during an error occurring when Banknotes
Flashes a Red, are being stored. Count the flashes of the specific Color to define the
Extinguished (Out) Green or Yellow error condition being indicated (see Appendix A of the Maintenance and
Color Service Manual for more detail).
While dispensing Banknotes, or during an error occurring when
Flashes a Red,
Extinguished (Out) dispensing Banknotes. Count the flashes of the specific Color to define
Green or Yellow the error condition being indicated (see Appendix A of the Maintenance
Color and Service Manual for more detail).
A Stand-by* Error occurred. Count the flashes of the specific Color to
Flashes (Green) Flashes (Green) define the error condition being indicated (see Appendix A of the
Maintenance and Service Manual for more detail).
Lit (Red) Lit (Red) A UBA-RC Software booting error occurred.
Lit (Yellow) Lit (Yellow) Downloading UBA-RC Software into the Unit.
Lit (Green) Lit (Green) A Reset was not performed after Power was Supplied.
*. This condition can exist when the UBA-RC is not performing Banknote storage, and an error occurred.

Table 18 Recycler Unit LED Flashing Error Code Conditions

LED Color LED Flashes Error Causes


TBD 1 UBA-RC Motor Speed Error.
TBD 2 Unit disabled to confirm that the RC1 Space Transport Motor is performing correctly.
TBD 3 Unit disabled to confirm that the RC2 Space Transport Motor is performing correctly.
TBD 4 Unit disabled to confirm that the RC1 Flapper is performing correctly.
TBD 5 Unit disabled to confirm that the RC2 Flapper is performing correctly.
TBD 6 Unit disabled to confirm that the Lifter is performing correctly.
Banknote Jam occurred in the Transport Path when storing a Banknote into the RC1
TBD 7 Space.
Banknote Jam occurred in the Cash Box when storing a Banknote into the RC1
TBD 8 Space.
Banknote Jam occurred in the Transport Path when storing a Banknote into the RC2
TBD 9 Space.
Banknote Jam occurred in the Cash Box when storing a Banknote into the RC2
TBD 10 Space.
Banknote Jam occurred in the Transport Path when storing a Banknote in the Cash
TBD 11 Box.
TBD 12 Banknote Jam occurred in the Cash Box when storing a Banknote to the Cash Box.
Banknote Jam occurred in the Transport Path when dispensing a Banknote from the
TBD 13 RC1 Space.
Banknote Jam occurred in the Cash Box when dispensing a Banknote from the RC1
TBD 14 Space.
Banknote Jam occurred in the Transport Path when dispensing a Banknote from the
TBD 15 RC2 Space.
Banknote Jam occurred in the Cash Box when dispensing a Banknote from the RC2
TBD 16 Space.
TBD 17 Unit disabled to access to the EE-PROM, or the Sensors are not calibrated.
TBD 18 Double Note Detection Sensor Magnification Error.

P/N 960-100928R_Rev. A {EDP #192691} 25 © 2010, Japan CashMachine Co, Limited


UBA-RC™ Series Banknote Recycler Integration Guide

11 INTERNATIONAL COMPLIANCE
• RoHS Directives or or or or

• UL & c-UL Marks

• CE Mark

• CB Scheme
NOTE: The above listed of compliance conditions are currently having their approval or certificate
verified.

P/N 960-100928R_Rev. A {EDP #192691} 26 © 2010, Japan CashMachine Co, Limited


UBA-RC™ Series Banknote Recycler Integration Guide

12 TECHNICAL CONTACT INFORMATION


AMERICAS & OCEANIA ASIA
JCM Global JCM Gold (HK) Ltd.
Phone: +1-702-651-0000 Phone: +852-2429-7187
Fax: +1-702-644-5512 Fax: +852-2929-7003
925 Pilot Road, Las Vegas, NV 89119 Unit 1-7, 3/F., Favor Industrial Centre
E-mail: customerservice@jcmglobal.com 2-6 Kin Hong Street, Kwai Chung,
EUROPE, AFRICA, RUSSIA & MIDDLE EAST N.T. Hong Kong
JCM Europe GmbH E-mail: asiapactechsupport@jcmglobal.com
Phone: +49-211-530-645-60 Japan Cash Machine Co, Limited (HQ)
Fax: +49-211-530-645-85 Phone: +81-6-6703-8400
Muendelheimer Weg 60 Fax: +81-6-6707-0348
D-40472 Duesseldorf Germany 2-3-15, Nishiwaki, Hirano-ku, Osaka 547-0035
E-mail: support@jcmglobal.eu JAPAN
UK & IRELAND E-mail: Shohin@jcm-hq.co.jp
JCM Europe (UK Office)
Phone: +44 (0) 1908-377-331 All of these Websites are available via:
Fax: +44 (0) 190-837-7834 http://www.jcmglobal.com
Unit B, Third Avenue
Denbigh West Business Park
Bletchley, Milton Keynes,
Buckinghamshire MK1 1DH, UK
E-mail: info@jcmglobal.eu

P/N 960-100928R_Rev. A {EDP #192691} 27 © 2010, Japan CashMachine Co, Limited


UBA-RC™ Series Banknote Recycler Integration Guide

THIS PAGE INTENTIONALLY LEFT BLANK

P/N 960-100928R_Rev. A {EDP #192691} 28 © 2010, Japan CashMachine Co, Limited


UBA-RC™ Series
Integration Guide
Index
13 INDEX T
C Technical Contact Information… Page 28
Cautions Troubleshooting
high temperature, high humidity or dusty areas Instructions for… Page 25
storage in… Page 2 U
Cleaning
methods of, and equipment required for… Page 12 UBA
Banknote Acceptor Unit
Contact Information acronym for… Page 1
Address and Telephone Numbers for… Page 28
F UBA-RC
Banknote Recycler Unit
acronym for… Page 1
Flowchart
Operational UBA-RC Unit

Page 16;
symbol language describing flow functions photo of a… Page 1
Page 17; Page 18; Page 19; Page 20; Page 21;
Page 22
N
Navigation
within manual
procedure for … Page 1
P
Pin Assignments
Table listing primary connector… Page 9; Page 10;
Page 11
Precautionary Symbols
types of… Page 2
Preventive Maintenance
cleaning material reqirements… Page 11
Primary Features
listing of… Page 3
S
Safety
pictographs indicating
1 to 3 symbols inside boxed area … Page 1
Special Notes
italic text highlights
finger points to… Page 1
Specifications
Electrical… Page 6
Environmental… Page 6
model number… Page 2
Structural… Page 6
Technical… Page 5
Steps
sequential numbering of… Page 1

P/N 960-100928R_Rev. A {EDP #192691} 29 © 2010, Japan CashMachine Co, Limited


UBA-RC™ Series Integration Guide Index

THIS PAGE INTENTIONALLY LEFT BLANK

P/N 960-100928R_Rev. A {EDP #192691} 30 © 2010, Japan CashMachine Co, Limited


UBA-RC™ Series Integration Guide Index

P/N 960-100928R_Rev. A {EDP #192691} © 2010, Japan CashMachine Co, Limited


UBA-RC™ Series Integration Guide

Issue #4088-IGE-01-00

P/N 960-100928R_Rev. A {EDP #192691} © 2010, Japan CashMachine Co, Limited

You might also like