Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
0% found this document useful (0 votes)
37 views12 pages

1 Anchor Design: Hilti PROFIS Engineering 3.0.94

Download as pdf or txt
Download as pdf or txt
Download as pdf or txt
You are on page 1/ 12

Hilti PROFIS Engineering 3.0.

94

www.hilti.de
Company: Page: 1
Address: Specifier:
Phone I Fax: | E-Mail:
Design: D2 Date: 25.04.2024
Fastening point:

Specifier's comments:

1 Anchor Design
1.1 Input data

Anchor type and diameter: HIT-HY 200-A V3 + HAS-U 8.8 M12


Return period (service life in years): 50
Item number: 2237085 HAS-U 8.8 M12x160 (element) / 2378171
HIT-HY 200-A V3 (adhesive)
Insert item # alternative: 2390233 HAS 8.8 M12x160
Effective embedment depth: hef,opti = 70.0 mm (hef,limit = 220.0 mm)
Material: 8.8
Evaluation Service Report: ETA 19/0601
Issued I Valid: 29.01.2024 | -
Proof: SOFA based on EN 1992-4, Chemical
Stand-off installation: eb = 0.0 mm (no stand-off); t = 30.0 mm

Anchor plate
CBFEM
: lx x ly x t = 200.0 mm x 200.0 mm x 30.0 mm;

Profile: Square hollow, 80 x 80 x 4,0; (L x W x T) = 80.0 mm x 80.0 mm x 4.0 mm


Base material: 2
cracked concrete, C25/30, fc,cyl = 25.00 N/mm ; h =250.0 mm, Temp. short/long: 40/24 °C,
User-defined partial material safety factor gc = 1.500
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: no reinforcement or reinforcement spacing >= 150 mm (any Ø) or >= 100 mm (Ø <= 10 mm)
no longitudinal edge reinforcement
Reinforcement to control splitting acc. to EN 1992-4, 7.2.1.7 (2) b) 2) present

CBFEM
- The anchor calculation is based on a component-based Finite Element Method (CBFEM)

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

1
Hilti PROFIS Engineering 3.0.94

www.hilti.de
Company: Page: 2
Address: Specifier:
Phone I Fax: | E-Mail:
Design: D2 Date: 25.04.2024
Fastening point:

1.1.1 Load combination


Case Description Forces [kN] / Moments [kNm] Seismic Fire Max. Util. Anchor [%]
1 Combination 1 N = -15.800; Vx = 15.800; Vy = 0.000; no no 22
Mx = 0.000; My = 0.000; Mz = 0.000;
Nsus = 0.000; Mx,sus = 0.000; My,sus = 0.000;

2 Combination 2 N = -21.300; Vx = 0.000; Vy = 11.600; no no 16


Mx = 0.000; My = 0.000; Mz = 0.000;
Nsus = 0.000; Mx,sus = 0.000; My,sus = 0.000;

3 Combination 3 N = 21.200; Vx = 13.700; Vy = 0.000; no no 58


Mx = 0.000; My = 0.000; Mz = 0.000;
Nsus = 0.000; Mx,sus = 0.000; My,sus = 0.000;

1.2 Load case/Resulting anchor forces y


Controlling load case: 3 Combination 3
3 4

Anchor reactions [kN]


Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y
x
1 5.271 3.426 3.426 0.007
2 5.329 3.424 3.424 -0.002 Tension
3 5.272 3.426 3.426 -0.007
4 5.328 3.424 3.424 0.002
1 2

resulting tension force in (x/y)=(0.3/-0.0): 21.200 [kN]


resulting compression force in (x/y)=(-/-): 0.000 [kN]

Anchor forces are calculated based on a component-based Finite Element Method (CBFEM)

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

2
Hilti PROFIS Engineering 3.0.94

www.hilti.de
Company: Page: 3
Address: Specifier:
Phone I Fax: | E-Mail:
Design: D2 Date: 25.04.2024
Fastening point:

1.3 Tension load EN 1992-4, Section 7.2.1

Load [kN] Capacity [kN] Utilization bN [%] Status


Steel Strength* 5.329 44.960 12 OK
Combined pullout-concrete cone failure** 21.200 42.073 51 OK
Concrete Breakout Failure** 21.200 37.006 58 OK
Splitting failure** N/A N/A N/A N/A

* highest loaded anchor **anchor group (anchors in tension)

1.3.1 Steel Strength

N
NEd £ NRd,s = Rk,s EN 1992-4, Table 7.1
gM,s

NRk,s [kN] gM,s NRd,s [kN] NEd [kN]


67.440 1.500 44.960 5.329

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

3
Hilti PROFIS Engineering 3.0.94

www.hilti.de
Company: Page: 4
Address: Specifier:
Phone I Fax: | E-Mail:
Design: D2 Date: 25.04.2024
Fastening point:

1.3.2 Combined pullout-concrete cone failure

N
NEd £ NRd,p = Rk,p EN 1992-4, Table 7.1
gM,p
0 Ap,N
NRk,p = NRk,p · 0
· y g,Np · y s,Np · y re,Np · y ec1,Np · y ec2,Np EN 1992-4, Eq. (7.13)
Ap,N
0
NRk,p = y sus · t Rk · p · d · hef EN 1992-4, Eq. (7.14)
y sus =1 EN 1992-4, Eq. (7.14a)

scr,Np = 7.3 · d · √y sus · t Rk £ 3 · hef EN 1992-4, Eq. (7.15)


0,5
y g,Np
0
= y g,Np -
s
s
( ) · (y g,Np - 1) ³ 1.00
cr,Np
0
EN 1992-4, Eq. (7.17)
1,5
0
y g,Np = √n - (√n - 1) · (tt )
Rk

Rk,c
³ 1.00 EN 1992-4, Eq. (7.18)
k3
t Rk,c = · √hef · fck EN 1992-4, Eq. (7.19)
p·d
c
y s,Np = 0.7 + 0.3 · 1.00 EN 1992-4, Eq. (7.20)
ccr,Np £
1
y ec1,Np = 1.00 EN 1992-4, Eq. (7.21)
2 · ec1,N £
1+ (
scr,Np )
1
y ec2,Np = 1.00 EN 1992-4, Eq. (7.21)
2 · ec2,N £
1+ (
scr,Np )
2 0 2 2 2
Ap,N [mm ] Ap,N [mm ] t Rk,ucr,20 [N/mm ] scr,Np [mm] ccr,Np [mm] cmin [mm] fc,cyl [N/mm ]
108,900 44,100 18.00 210.0 105.0 ∞ 25.00
0
yc t Rk,cr [N/mm ]
2
k3 t Rk,c [N/mm ]
2
y g,Np y g,Np
1.023 9.71 7.700 8.54 1.000 1.000

ec1,N [mm] y ec1,Np ec2,N [mm] y ec2,Np y s,Np y re,Np


0.3 0.997 0.0 1.000 1.000 1.000
0
y sus asus y sus
0.800 0.000 1.000
0
NRk,p [kN] NRk,p [kN] gM,p NRd,p [kN] NEd [kN]
25.636 63.110 1.500 42.073 21.200

Group anchor ID
1-4

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

4
Hilti PROFIS Engineering 3.0.94

www.hilti.de
Company: Page: 5
Address: Specifier:
Phone I Fax: | E-Mail:
Design: D2 Date: 25.04.2024
Fastening point:

1.3.3 Concrete Breakout Failure

N
NEd £ NRd,c = Rk,c EN 1992-4, Table 7.1
gM,c
0 Ac,N
NRk,c = NRk,c · 0
· y s,N · y re,N · y ec1,N · y ec2,N · y M,N EN 1992-4, Eq. (7.1)
Ac,N
0 1,5
NRk,c = k1 · √fck · hef EN 1992-4, Eq. (7.2)
0
Ac,N = scr,N · scr,N EN 1992-4, Eq. (7.3)
c
y s,N = 0.7 + 0.3 · 1.00 EN 1992-4, Eq. (7.4)
ccr,N £
1
y ec1,N = £ 1.00 EN 1992-4, Eq. (7.6)
1+ ( 2 · eN,1
scr,N )
1
y ec2,N = £ 1.00 EN 1992-4, Eq. (7.6)
1+ ( 2 · eN,2
scr,N )
y M,N =1 EN 1992-4, Eq. (7.7)

2 0 2 2
Ac,N [mm ] Ac,N [mm ] ccr,N [mm] scr,N [mm] fc,cyl [N/mm ]
108,900 44,100 105.0 210.0 25.00

ec1,N [mm] y ec1,N ec2,N [mm] y ec2,N y s,N y re,N


0.3 0.997 0.0 1.000 1.000 1.000
0
z [mm] y M,N k1 NRk,c [kN] gM,c NRd,c [kN] NEd [kN]
0.0 1.000 7.700 22.548 1.500 37.006 21.200

Group anchor ID
1-4

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

5
Hilti PROFIS Engineering 3.0.94

www.hilti.de
Company: Page: 6
Address: Specifier:
Phone I Fax: | E-Mail:
Design: D2 Date: 25.04.2024
Fastening point:

1.4 Shear load EN 1992-4, Section 7.2.2

Load [kN] Capacity [kN] Utilization bV [%] Status


Steel Strength (without lever arm)* 3.426 26.976 13 OK
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout Strength** 13.700 74.240 19 OK
Concrete edge failure in direction ** N/A N/A N/A N/A

* highest loaded anchor **anchor group (relevant anchors)

1.4.1 Steel Strength (without lever arm)

V
VEd £ VRd,s = Rk,s EN 1992-4, Table 7.2
gM,s
0
VRk,s = k7 · VRk,s EN 1992-4, Eq. (7.35)

0
VRk,s [kN] k7 VRk,s [kN] gM,s VRd,s [kN] VEd [kN]
33.720 1.000 33.720 1.250 26.976 3.426

1.4.2 Pryout Strength (Concrete Breakout Strength controls)

V
VEd £ VRd,cp = Rk,cp EN 1992-4, Table 7.2
gM,c,p
VRk,cp = k8 · min {NRk,c; NRk,p} EN 1992-4, Eq. (7.39c)
0 A
NRk,c = NRk,c · 0c,N · y s,N · y re,N · y ec1,N · y ec2,N · y M,N EN 1992-4, Eq. (7.1)
Ac,N
0 1,5
NRk,c = k1 · √fck · hef EN 1992-4, Eq. (7.2)
0
Ac,N = scr,N · scr,N EN 1992-4, Eq. (7.3)
c
y s,N = 0.7 + 0.3 · 1.00 EN 1992-4, Eq. (7.4)
ccr,N £
1
y ec1,N = £ 1.00 EN 1992-4, Eq. (7.6)
1+ ( 2 · eV,1
scr,N )
1
y ec2,N = £ 1.00 EN 1992-4, Eq. (7.6)
1+ ( 2 · eV,2
scr,N )
y M,N =1 EN 1992-4, Eq. (7.7)

2 0 2 2
Ac,N [mm ] Ac,N [mm ] ccr,N [mm] scr,N [mm] k8 fc,cyl [N/mm ]
108,900 44,100 105.0 210.0 2.000 25.00

ec1,V [mm] y ec1,N ec2,V [mm] y ec2,N y s,N y re,N y M,N


0.0 1.000 0.0 1.000 1.000 1.000 1.000
0
k1 NRk,c [kN] gM,c,p VRd,cp [kN] VEd [kN]
7.700 22.548 1.500 74.240 13.700

Group anchor ID
1-4

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

6
Hilti PROFIS Engineering 3.0.94

www.hilti.de
Company: Page: 7
Address: Specifier:
Phone I Fax: | E-Mail:
Design: D2 Date: 25.04.2024
Fastening point:

1.5 Combined tension and shear loads (EN 1992-4, Section 7.2.3)
Steel failure

bN bV a Utilization bN,V [%] Status


0.119 0.127 2.000 4 OK

a a
bN + bV £ 1.0

Concrete failure

bN bV a Utilization bN,V [%] Status


0.573 0.185 1.500 52 OK

a a
bN + bV £ 1.0

1.6 Warnings
• The anchor design methods in PROFIS Engineering require rigid anchor plates as per current regulations (ETAG 001/Annex C, EOTA
TR029, etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor
plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates
the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above.
The proof if the rigid base plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for
agreement with the existing conditions and for plausibility!
• Checking the transfer of loads into the base material is required in accordance with EN 1992-4, Annex A!
• The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 6.1 of EN 1992-4! For larger diameters
of the clearance hole see section 6.2.2 of EN 1992-4!
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
• For the determination of the y re,v (concrete edge failure) the minimum concrete cover defined in the design settings is used as the concrete
cover of the edge reinforcement.
• Bore hole cleaning must be performed according to instructions for use (blow twice with oil-free compressed air (min. 6 bar), brush twice,
blow twice with oil-free compressed air (min. 6 bar)).
• Characteristic bond resistances depend on short- and long-term temperatures.
• Edge reinforcement is not required to avoid splitting failure
• Load transfer from supplementary reinforcement to the structural member shall be verified by the responsible structural engineer.
• With supplementary reinforcement and post-installed anchors, please ensure that in the jobsite the rebars are not drilled through.
• The anchor design methods in PROFIS Engineering require rigid anchor plates, as per current regulations (AS 5216:2021, ETAG 001/Annex
C, EOTA TR029 etc.). This means that the anchor plate should be sufficiently rigid to prevent load re-distribution to the anchors due to
elastic/plastic displacements. The user accepts that the anchor plate is considered close to rigid by engineering judgment."
• The characteristic bond resistances depend on the return period (service life in years): 50

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

7
Hilti PROFIS Engineering 3.0.94

www.hilti.de
Company: Page: 8
Address: Specifier:
Phone I Fax: | E-Mail:
Design: D2 Date: 25.04.2024
Fastening point:

1.7 Installation data


2
Anchor plate, steel: S 355; E = 210,000.00 N/mm ; fyk = 355.00 N/mm
2 Anchor type and diameter: HIT-HY 200-A V3 + HAS-U 8.8
M12
Profile: Square hollow, 80 x 80 x 4,0; (L x W x T) = 80.0 mm x 80.0 mm x 4.0 Item number: 2237085 HAS-U 8.8 M12x160 (element) /
mm 2378171 HIT-HY 200-A V3 (adhesive)
Hole diameter in the fixture: df = 14.0 mm Insert item # alternative: 2390233 HAS 8.8 M12x160
Plate thickness (input): 30.0 mm Maximum installation torque: 40 Nm
Hole diameter in the base material: 14.0 mm
Drilling method: Hammer drilled Hole depth in the base material: 70.0 mm
Cleaning: Compressed air cleaning of the drilled hole according to instructions Minimum thickness of the base material: 100.0 mm
for use is required

Hilti HAS-U or HAS threaded rod with HIT-HY 200-A V3 injection mortar with 70 mm embedment h_ef, M12, Steel galvanized, Hammer drilled
installation per ETA 19/0601

1.7.1 Recommended accessories

Drilling Cleaning Setting


• Suitable Rotary Hammer • Compressed air with required • Dispenser including cassette and mixer
• Properly sized drill bit accessories to blow from the bottom of • For deep installations, a piston plug is
the hole necessary
• Proper diameter wire brush • Torque wrench

y
100.0 100.0
40.0

3 4
100.0
120.0

x
100.0

1 2
40.0

40.0 120.0 40.0

Coordinates Anchor [mm]


Anchor x y c-x c+x c-y c+y
1 -60.0 -60.0 - - - -
2 60.0 -60.0 - - - -
3 -60.0 60.0 - - - -
4 60.0 60.0 - - - -

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

8
Hilti PROFIS Engineering 3.0.94

www.hilti.de
Company: Page: 9
Address: Specifier:
Phone I Fax: | E-Mail:
Design: D2 Date: 25.04.2024
Fastening point:

2 Anchor plate rigidity check

2.1 Input data


Anchor plate: Shape: Rectangular
lx x ly x t = 200.0 mm x 200.0 mm x 30.0 mm
Calculation: Anchor Plate Rigidity Check
Material: S 355; Fy = 355.00 N/mm²; εlim = 5.00%
Anchor type and size: HIT-HY 200-A V3 + HAS-U 8.8 M12, hef = 70.0 mm
Anchor stiffness: The anchor is modeled considering stiffness values determined from load displacement curves tested in an
independent laboratory. Please note that no simple replacement of the anchor is possible as the anchor
stiffness has a major impact on the load distribution results.
Design method: EN-based design using component-based FEM
Stand-off installation: eb = 0.0 mm (No stand-off); t = 30.0 mm
Profile: 80 x 80 x 4,0; (L x W x T x FT) = 80.0 mm x 80.0 mm x 4.0 mm x -
Material: S 355; Fy = 355.00 N/mm²; εlim = 5.00%
Eccentricity x: 0.0 mm
Eccentricity y: 0.0 mm
Base material: Cracked concrete; C25/30; fc,cyl = 25.00 N/mm²; h = 250.0 mm; E = 31,000.00 N/mm²; G = 12,916.67
N/mm²; v = 0.20
Welds (profile to anchor plate): Type of redistribution: Plastic
Material: S 235
Mesh size: Number of elements on edge: 8
Min. size of element: 10.0 mm
Max. size of element: 50.0 mm

2.2 Anchor plate classification


Results below are displayed for the decisive load combinations: Combination 3
Anchor tension forces Equivalent rigid anchor plate (CBFEM) Component-based Finite Element Method
(CBFEM) anchor plate design
Anchor 1 5.271 kN 5.271 kN
Anchor 2 5.329 kN 5.329 kN
Anchor 3 5.271 kN 5.272 kN
Anchor 4 5.329 kN 5.328 kN

User accepted to consider the selected anchor plate as rigid by his/her engineering judgement. This means the anchor design guidelines can
be applied.

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

9
Hilti PROFIS Engineering 3.0.94

www.hilti.de
Company: Page: 10
Address: Specifier:
Phone I Fax: | E-Mail:
Design: D2 Date: 25.04.2024
Fastening point:

2.3 Warnings
● By using the CBFEM calculation functionality of PROFIS Engineering you may act outside the applicable design codes and your specified
anchor plate may not behave rigid. Please, validate the results with a professional designer and/or structural engineer to ensure suitability
and adequacy for your specific jurisdiction and project requirements.
● The anchor is modeled considering stiffness values determined from load displacement curves tested in an independent laboratory.
Please note that no simple replacement of the anchor is possible as the anchor stiffness has a major impact on the load distribution
results.

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

10
Hilti PROFIS Engineering 3.0.94

www.hilti.de
Company: Page: 11
Address: Specifier:
Phone I Fax: | E-Mail:
Design: D2 Date: 25.04.2024
Fastening point:

3 Summary of results
Load combination Max. utilization Status
Anchors Combination 3 58% OK

Fastening meets the design criteria!

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

11
Hilti PROFIS Engineering 3.0.94

www.hilti.de
Company: Page: 12
Address: Specifier:
Phone I Fax: | E-Mail:
Design: D2 Date: 25.04.2024
Fastening point:

4 Remarks; Your Cooperation Duties


● Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles,
formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc.,
that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be
conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based
essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the
relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and
cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility.
The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and
the relevance of the results or suitability for a specific application.
● You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for
the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you
do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the
Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery
of lost or damaged data or programs, arising from a culpable breach of duty by you.

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan