ABOUTAUTODESK FORMIT
* For large, complex models, Windows App performs better than Web / iPad
https://www.youtube.com/watch?v=VD2GE8B6vJE
+ For Programming
Energyoptimization madeeasy:
High-
Performance
Building Design
Curriculum
Autodesk-sponsored
AIA+2030 Online
Education Series
ormit - nsight
Formit – Insight Workflow
Conceptual Design
Abstract
This document explores digital workflows in the
conceptual stages of design, including program
validation using FormIt Pro & performance analytics
using Autodesk Insight,
ormit - nsight
Exercise 1
Explore FormIt Pro
How to Access Formit Software 2 Ways
1. Open via web : https://app.formit.autodesk. com/
2. Install Formit Apps on Windows
ormit - nsight
Exercise 1
Explore FormIt Pro
ormit - nsight
Exercise 1
Explore FormIt Pro
ormit - nsight
Exercise 2
Program Validation Using FormIt Pro
In this section, you will learn how to track gross area calculations in a
conceptual model created in FormIt.
ormit - nsight
Exercise 2
Program Validation Using FormIt Pro
2. Create a Group to organize your conceptual design geometry and
aggregate the calculation of areas with Levels. Open a window selection
and enclose all the mass geometry in the model. With the cursor over a
form, group the geometry using the rightclick context menu.
Note: Alternatively, you can find the Create > Group command
under the Create tab or use the Shortcut Ctrl+G.
ormit - nsight
Exercise 2
Program Validation Using FormIt Pro
3. To aid in the organization of your conceptual model, name the Groups you
create. Select the Group, open the Properties panel, and change its Name
value to “Massing Model”.
ormit - nsight
Exercise 2
Program Validation Using FormIt Pro
4. To calculate areas in FormIt, Levels must be created and applied to the
model geometry. When Levels are applied, they will be translated as Revit
Levels upon import. Open the Levels panel on the right-hand side of
FormIt. Create a new Level by clicking the “+” button. You can rename a
Level by double-clicking on its name, and you can adjust a Level’s
elevation by double-clicking on its elevation value.
ormit - nsight
Exercise 2
Program Validation Using FormIt Pro
5. Levels are an object or group property. Select the Group of all the mass
geometry, and in the Properties Panel, enable the “Use Levels”
checkbox. The geometry will display the intersection with the selected
Levels defined in the project.
Once Levels are applied, the group Properties will report the area per
level, the total aggregate gross area, and the total volume.
ormit - nsight
Exercise 2
Program Validation Using FormIt Pro
6. The Sketch Properties dialog reports the total Gross Area, the Target
Area, the Floor Area Ratio, and the Site Area. You can compare this
value against your proposed target area value to validate the building
program at a conceptual level.
7. Save the sketch file as LTU- Massing-Areas.axm.
ormit - nsight
Exercise 3
Program Analysis In FormIt Pro
In this exercise, you will learn to run energy simulations and performance
analytics using Autodesk Insight. Insight provides a dashboard of energy
performance scenarios that can be updated as your model updates.
1. Open the LTU-Massing-Analysis.axm file in FormIt Pro. To successfully
generate an energy simulation using Insight, check the following
requirements:
ormit - nsight
Exercise 3
Program Analysis In FormIt Pro
2. Study the impact of direct sun insolation on your conceptual
model. Click the Solar Analysis button under the Sun menu.
ormit - nsight
Exercise 3
Program Analysis In FormIt Pro
3. Pick the model geometry you want to analyze and click the
Analyze button in the Solar Analysis toolbar.
ormit - nsight
Exercise 3
Program Analysis In FormIt Pro
4. The Month Peak setting shows the peak values (in Wh/m2) for the
specified month and is intended for shading studies. You can
change the month setting, and the graphics update instantly.
Hover your cursor over an analyzed surface to get a specific
value.
ormit - nsight
Exercise 3
Program Analysis In FormIt Pro
5. The Year Cumulative setting shows the cumulative energy for the
entire year (in kWh/m2), and it is intended for PV potential
studies.
ormit - nsight
Exercise 3
Program Analysis In FormIt Pro
6. Click the checkmark in the Solar Analysis toolbar to exit the study,
and save the sketch
ormit - nsight
Exercise 3
Program Analysis In FormIt Pro
7. Click the Generate Insight button under the Insight menu. The
analysis will run in the cloud, and you can continue modeling
during the computation
ormit - nsight
Exercise 3
Program Analysis In FormIt Pro
8. Once the analysis is complete, click the View Insight button to see
your Energy model and Performance Factors. Optionally, you can
log into the Autodesk Insight web page for more features at
http://insight.autodesk.com.
ormit - nsight
Exercise 3
Program Analysis In FormIt Pro
9. On the Insight dashboard, you can set a value (or value range) for
each Performance Factor widget by clicking the factor and
dragging the blue dots. The range is helpful if you don't know the
specific system(s) your building will use yet. With each change to a
Factor, the overall Energy Cost Range (measured in USD/m2/yr)
updates. You can compare your design's performance against
benchmarks like ASHRAE 90.1 and the Architecture 2030
Challenge.