EPRC ST10 Controller
EPRC ST10 Controller
Use with 12V or 24V batteries only Use with 12V or 24V systems only
4. Connect the BATTERY first. Use care that bare wires do not touch the metal case of the controller. 5. Connect the SOLAR(PV array) next. The green LED indicator will light if sunlight is present. 6. Connect the LIGHT last. If the red LED indicator lights, the battery capacity is low and should be charged before completing the system installation 7. Press the BUTTON as 16 or 17 to verify the system connecting.
LED INDICATOR
Green ON when solar is charging battery Green blink when the system over voltage . .. . Green ON when battery level in the right range Green slowly flashing when battery level full Yellow ON when battery level low Red ON when loads cut off ... Red ON when the output is on. Red slowly flashing when its over load (the load amps is 1.25 times of rated current for 60 seconds, or the load amps is 1.5 times of rated current for 5 seconds) Red blink when the load is short-circuit. ... Please note: the output will cut off once there is over load or short circuit. Disconnect all the equipment and reconnect, and press the button, the controller will resume to work after 10 seconds, or wait for it to work the next day.
TROUBLESHOOTING
1. Charging LED indicator is off when it is daytime a. The green Charging LED should be on if its day time. b. Check that the proper battery type has been selected. c. Check that all wire connections in the system are correct and tight. Check the polarity(+ and -) of the connections d. Measure the PV array open-circuit voltage and confirm it is within normal limits. If the voltage is low or zero, check the connections at the PV array itself. Disconnect the PV from the controller when working on the PV array. e. Measure the PV voltage and the battery voltage at the controller terminals. If the voltage at the terminals is the same(within a few tenths of volts) the PV array is charging the battery. If the PV voltage is close to the open circuit voltage of the panels and the battery voltage is low, the controller is not charging the batteries and may be damaged. 2. Charging LED indicator is blinking a. First check the operating conditions to confirm that the voltage is higher than specifications. Consider the temperature compensation of the controller PWM setpoint. s For example, at 0 the controller will regulate at about 15.0 volts b. Check that all wire connections in the system are correct and tight. 3. Load LED indicator is blinking, or flashing or on red(load not operating properly) a. Check that the load is turned on. Check that no system fuses are defective. b. Check connections to the load, and other controller and battery connections. Make sure voltage drops in the system wires are not too high. c. If the LED indicator is blinking and no output, check if the load is short-circuit. Disconnect the load, and press the switch button, the controller will return to work after 30 seconds.
d. If the LED indicator is flashing and no output, check if the load is over the rated power. Reduce the load, and press the switch button, the controller will return to work after 30 seconds.
MECHANICAL